Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.4 LAccepted-AOC R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹32.0 L+₹1.6 L (5.09%)Rejected-AOC | L-2 | Rejected-AOC Other than Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
5 Nov 2022, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
PROVN OF 03X ELEVATED SENTRY POST AT UPLONA,PROVN OF MT VEH SHED AT MAZBUG, CONSTRUCTION OF 10X SOAK PITS AT KALOOSA AND SPL REPAIR TO RDS OF CNVY GRND AT PATTAN UNDER GE 969 EWS
2022_MES_556644_1
CANO 969/WS- /2022-23
Open Tender
Civil Works
Item Rate
180 days
Pattan
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE 969 EWS
₹60,000
Yes
7 Dec 2022
8 Oct 2022
7 Nov 2022
8 Oct 2022
5 Nov 2022
22 Oct 2022
Amount
M&L for Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm N exc 50mm deep complete all as specified.
Soling (or sub base) spread thickness 100mm with broken boulders or quarried stone,inter stices filled, surface formed and rolled and consolidation to required gradient and camber.
Rolling and Consolidation formation in cutting with power roller using 8 to 12 tonne complete all as specified and as directed.
M&L for Polythene film, black, 50micron laid in floors complete all as specified and as directed.
M&L for Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded stone aggregate) as in foundations, fillings and mass concrete etc complete all as specified and as directed.
M&L 25mm thick sand filling under floors or in foundations including watering and well consolidation complete all as specified and as directed.
M&L Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less.Complete all as specified and as directed.
Forming construction joint 150mm deep x 10mm wide filled with sealing compound.
M&L Hardcore of gauge broken bricks exc 63 mm but n. exc 100mm deposited, spread and levelled in layers n. exc 15 cm thick, watered surface complete all as specified.
M&L 100 mm Cement concrete type B-2,1:2:4 (40mm graded aggregate) mass concrete in flooring.Complete all as specified and as directed.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out from soft and loose soil complete all as specified.
Excavation in post holes (or similar holes) each n. exc 0.5 Cum, getting out from hard and dense soil returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone agg) as in foundations, filling and mass concrete complete all as specified and as directed.
Removing Excavated soils exceeding 500 M but not exceeding 1.5 KM and depositing where directing complete all as specified and as directed.
M&L for Cement concrete 1:2:4 type B using (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F Roof trusses (framed) trussed, Purlis, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee, angle channel or flat sections) includign distance pieces cleats etc conforming to IS.1161-1979 grade St.240. Complete all as specified.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes as in post confirming to Fe-410 W (Gde-E-250) quality-A complete all as specified.
M&L steel iron base plate plugs, bolt and screw of Fe-410W (Gde-E-250 quality-A) complete all as specified and directed.
Hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surtace.
100 mm thick Cement Concrete Type D-2 1:4:8 (using 40 mm graded aggregate) mass concrete in flooring. Complete all as specified and as directed.
M&L for 150 mm thick Cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in flooring /hardstanding and finishing cement concrete surface even and smooth complete all as specified.
M&L for 20mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings and finished even and smooth using with power floater (except metallic hardner) complete all as specified and as directed.
Supply only metallic floor hardner
Forming contraction dummy joint of 65mm deep x 10mm wide filled with sealing compound of grade 'A.
Forming 12 mm thick expansion joints on 150 mm thick concrete slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound grade 'A'
Preparation of new previously untreated steel surfaces of any despcription over 10 cm width or girth, otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Excavation in trenches in any type of soil, exc 1.50 M wide and exc 1.5 M deep for foundation, etc or for shafts, wells, manholes etc n.exc 10 sqm on plan and exc 1.5m in depth and getting out in any type of soil complete all as directed.
All as per above Serial Item No. 29 but exc 1.5m but not exc. 3m complete all as specified and as directed.
Returning filling in including spreading levelling, watering and well ramming in laver n.exc 25 cm complete all as specified and as directed.
M&L for Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in fioors complete all as specified and as directed.
M&L for RCC nominal mix with type B-1 1:2:4 (using 20mm graded crushed stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, balconies, landings canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC nominal mix with type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for form work to sides and soffits of floor or roof beam, haunchings, girders, bressumers, lintels, cantilvers etc,also splays between floor and beams. etc, in roug finished surface of concrete.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs. landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished Surtace complete all as specified and as directed.
Mild steel TMT bars 10 mm dia and over Cut to length bent to shape required including cranking. bending spirally for hooping for columns, hooking ends and binding with steel wire (annealed not less than 0.9 mm dia complete all as specified and as directed.
Mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire(annealed not less than 0 9 mm dia complete all as specified and as directed.
M&L Damp proofing course to horizontal surface including necessary formwork in cement mortar 1:2:4, type B-0, 40mm thick complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on brick work surfaces other than fair faces of brick work in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying three coat of white wash compiete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L 75 mm thick cement concrete type C-2, 1:3:6 (using 20 mm graded stone agg) as in plinth protection and similar works including finishing the surface of concrete topping even and fair, without using extra cement complete all as specified and as directed.
S&F 0.63mm galvanised, corrugated mild steel sheeting with two corrugations Side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 120 fixed with 'J' or 'L' hooks all as specified and directed.
S&F 0.80 mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters,drip and straight flashings (length and girth as fixed) with grade of zinc coating 120.Complete all as specified and as directed.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or,riverted, or forged into spikes; framed guard bars, barred iron doors; ladders framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F 2nd class soft wood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together With glue pinned at joints supplied and fixed complete all as specified and as directed.
S&F 30 mm thick 2nd class soft wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
S&F 100 mm long butt hinges, medium weight cold rolled, mild steel complete all as specified and as directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F 150mm long Aluminium handles, cast type, anodised complete all as specified and as directed.
M&L for preparation of new wooden surfaces and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Note:- Schedule of credit Rs 6,312.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
Javeed And Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .