Loading…
Loading…
Tender ID
Tender Value
₹30 L
EMD Value
₹40,000
Closing Date
21 Feb 2026, 6:10 pmClosed
The E.E.(O&M), Sachin Division
Tenderization for ARC Work of Laying testing & commissioning of 11/22 KV UG XLPE CABLE with 11/22 KV Cable End Termination & ST joint Kits (to be Supplies by Agency) along with Erection of HT,LT & TC , Maintenance works under Sachin-1 Sdn and if required any other Sdn under jurisdiction of Sachin Division under ND and if Required Any other Scheme.
272919
SD/O&M/EXP/26/657 Date:03.02.2026
Open
Electrical Works
Works
Surat
6 documents required · 6 mandatory
₹1,180
Online Payment in DGVCL Sachin Division Account
₹40,000
4 Feb 2026
4 Feb 2026
4 Feb 2026
21 Feb 2026
4 Feb 2026
The statement showing items of works to be carried out for erection work of HT/LT lines , T/C ,Laying Testing
& Commissioning of XLPE UG CABLE & maintenance of feeders for various scheme for Various sub division
under the control of Sachin (O&M) Division.
HT,LT &TC Revised as per Letter No DGCS/1408/01/2025 Approved Date: 27-01-2025
Ammendment HT,LT &TC Revised as per Letter No DGCS/0693/02/2025 Approved Date: 12-02-2025
Maintenance Revised as per Letter No DGCS/1410/01/2025 Approved Date: 27-01-2025
UG Cable Revised as per Letter No DGCS/1411/01/2025 Approved Date: 27-01-2025
Name of Work :- Rate contract for erection of HT/LT line & T/C work for various scheme work for SDN office
under Sachin Division Office.
ITEM CODE Details of Works Qty Unit Amount
HT TAPPING FROM THE EXISTING POLE INCLUDING
FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC.
1 9926000001 COMPLETE AND PAINTING OF FABRICATED No. 481
MATERIALS AND NUMBERING COMPLETE WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH,
FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OFCROSS ARMS, TOP FITTING
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,
3 9926000003 INSULATORS ETC. COMPLETE AND PAINTING OF No. 1949
STEEL POLE, FABRICATED MATERIALS USED ON THE
POLEAND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR
RAILWAY CROSSING ON BG/MG/NG LINE FOR
0.400/11/22KV OVERHEAD LINES I.E INCLUDING
EXCAVATION OF PIT & REFILLING OF EARTH, FIXING
CROSS ARMS, TOP FITTING CLAMPS,ANTI-CLIMBING
4 9926000004 DEVICES DANGER BOARD, INSULATORS ETC. No. 2325
COMPLETE AND PAINTING OF STEEL POLES,
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO
METERS.STEEL POLE INCLUDING EXCAVATION OF
PITS & REFILLING OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING
DEVICES DANGER BOARDS, INSULATORS
ETC.COMPLETE & PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND NUMBERING
WITH COST OF PAINTSAS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH, HG FUSES OF 8 MTRS
KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS
SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
7 9926000007 DEVICES, DANGER BOARDS, INSULATORS,DOFUSES No. 3179
ETC. COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDINGOF ERECTION OF
GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES, 9 TO
METERS STEEL POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, FIXING OFCHANNEL,
SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
8 9926000008 DEVICES , DANGER BOARDS, INSULATORS, ETC. No. 4171
COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METERS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROMSTORES
TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS USEDON
THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL POLES
INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS FROM STORE
TO SITE, FIXINGOF CHANNELS SUPPORTING ANGLES,
BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING
DEVICES, DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTIONS OF GUY SETS AND
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
ERECTION OF GUY SET INCLUDING EXCAVATION OF
PITS & REFILLING OF EARTH AS PER STANDARD
SPECIFICATION WITH STAY CLAMPS, STAY WIRE,
ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY
INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING
12 9926000012 COST OF CEMENT SAND METAL (1:2:4) AND WATER CMT 8396
ETC. AS PER STANDARD SPECIFICATION.
ERECTION OF COIL TYPE EARTHING INCLUDING COST
OF COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE
AS PER STANDARD SPECIFICATION(20kg solt+20kg
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT
COST OF PIPE/GIPLATE GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE
WITH CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK
15 9926000015 WOOD BUSH,REFLECTORS FUSE, WIRING ETC. AS No. 359
PER STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
STRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT
DOG CONDUCTOR) FOR 11/22KV & LT LINES ONE COND
INCLUDING FIXING OF INSULATORS, BINDING PER KM
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING
PROVIDING SINGLE PHASE SERVICE CONNECTION
WITH PVC 4MM TWIN CORE CABLE FROM TERMINAL
POLE TO METERING POINT INCLUDING FIXING OF
METER WITH METER EARTHING COMPLETE WORK AS
PER STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2 FOUR CORE
CABLE FROM TERMINAL POLE TO METERING POINT
INCLUDING FIXING OF METER WITH METER EARTHING
COMPLETE WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD
ROCK AREA FOR ERECTION OF POLE/ GUY ETC. AS
PER STANDARD SPECIFICATION OVER & ABOVE
20 9926000020 NORMAL COST COVERED AGAINST EXCAVATION OF No. 359
PIT UNDER NORMAL SOIL FOR ERECTION OF
POLE,GUY, DOUBLE POLE STRUCTURE EARTHING
WITH THE APPROVAL OF SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL
PROVIDING GUARDING OF LT LINES ON ROAD/RAIL
23 9926000023 LT LINE TAPPING- SINGLE PHASE No. 51
24 9926000024 LT LINE TAPPING- THREE PHASE No. 93
LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE LINE No. 263
CROSSING ETC.(PER SPAN)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
ERECTION OF SINGLE POLE STRUCTURES WITH , HG
FUSES,TRANSFORMERS, LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC
POLE INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROM STORES TO SITE, FIXING OF CHANNELS,
26 9926000026 SUPPORTING ANGLES,BRACINGS CROSS ARMS No. 4537
CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLE AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH , HG
FUSES,TRANSFORMERS, LIGHTENINGARRESTOR,
DISTRIBUTION BOX. ON 9 to 11 METERS RSJ POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES
TO SITE, FIXING OF CHANNELS, SUPPORTING
27 9926000027 ANGLES,BRACINGS CROSS ARMS CLAMPS, No. 5305
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLE AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH,
FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 270 KG PSC POLES INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC
30 9926000030 CONDUCTOR FOR LT LINES INCLUDING FIXING 4861
OFINSULATORS, BINDING JUMPERING ETC.
STRINGING OF DOG CONDUCTOR FOR 11/22KV HT
31 9926000031 LINES INCLUDING FIXING OF INSULATORS, BINDING 4378
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 10 METERS 270 KGAND PSC
POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS
CLAMPS, ANTI-CLIMBING DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE & STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE & STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR
PSC POLE) (WITH TRANSFORMER) WITH CREDITING
35 9926000035 OF FABRICATION & TRANSFORMER AT STORE & No. 3975
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR
PSC POLE) (WITHOUT TRANSFORMER) WITH
36 9926000036 CREDITING OF FABRICATION AT STORE & STACKING No. 2701
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR
FIXING OF MESSENGER WIRE AND TO PROVIDE
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED
& DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE
38 9926000038 INSULATOR ETC. FOR FIXING OF MESSENGER WIRE KM 12330
AND TO PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLE POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLE POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+
35 SQ MM INCLUDING FITTING OF ALL ACESSARIES
I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP,
FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC.
41 9926000041 FOR FIXING OF MESSENGER WIRE AND TO PROVIDE KM 9863
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED
& DIRECTED BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND
CREDITING THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITHOUT TRANSFORMER)
43 9926000043 WITH CREDITING OF FABRICATION AT STORE AND No. 2828
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITH TRANSFORMER) WITH
44 9926000044 CREDITING OF FABRICATION AT STORE AND No. 5332
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ
45 9926000045 MM AND CREDITING FITTING OF ALL ACESSARIES KM 20515
AND FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ
46 9926000046 MM AND CREDITING FITTING OF ALL ACESSARIES KM 25643
AND FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ
MM AND CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT
DOG CONDUCTOR) FOR 11/22KV & LT LINES ONE COND
INCLUDING FIXING OF INSULATORS, BINDING PER KM
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT ONE COND
LINES INCLUDING , BINDING JUMPERING ETC. PER KM
LABOUR CHARGE FOR THE INSTALLATION OF NEW
DTR METER. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR
53 9926000053 METER AND OLD METER SHOULD BE CREDITED TO No. 531
SDN STORE. (METER WILL BE PROVIDED BY DGVCL)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR
54 9926000054 METER CONNECTION. (CT COIL WILL BE PROVIDED BY PER CT 85
LABOUR CHARGE FOR REPLACEMENT OF CT COIL
FOR DTR METER CONNECTION AND OLD CT SHOULD
BE CREDITED TO SDN STORE. (CT COIL WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR
METER (MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR METER
BOX. (METER WILL BE PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE
58 9926000058 COPPER CABLE 3.5 METER (CABLE TO BE PROVIDED No. 1840
LABOUR CHARGE FOR PROVIDING/RECONNECTION
59 9926000059 OF TERMINAL CONNECTION WITH PROPER SIZE OF 15
LUGS. (LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING OF DTR
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A
DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY
IN PRO-FORMA REPORT SHOULD BE SUBMITTED TO
60 9926000060 SDN OFFICE.(* ONLY IF ALL PARAMETER OF PER DTR 60
VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-
FORMA IS FILLED) AS PER THE INSTRUCTION OF
ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A
DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY
61 9926000061 IN PRO-FORMA REPORT SHOULD BE SUBMITTED TO PER DTR 30
SDN OFFICE. (DULY FILL PER-FORMA IN FAULT
CONDITION IN WHICH READING PARAMETER IS NOT
SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER
BOX, PROVIDING & FIXING OF 1.5SQ MM SINGLE
STRAND 10 CORE ARMOURED COPPER CABLE
(3.5METER), TERMINATION IN METER & COIL ETC.
(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER
BOX, TERMINATION IN METER & COIL ETC. (WITHOUT
10CORE COPPER CABLE) (METER, METER BOX,
C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not more
64 9926000064 than 0.75 mtr with 6 turns minimum on XLPE Cable with No
single strand binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV Resistance) with
using 95/120/150 sq.mm long barrel aluminum lug. (1Set =
Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of bare conductor
by HT ABC conductor (DO bottom side to transformer) after
removal of semi conductor by HT ABC (6 inch both side).
HT ABC to be supplied by DGVCL. (1Set = 3 Nos i.e. on R,
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
67 9926000088 Type, Earth Electrodes for HT Feeder Pole Having 2000 mm No
Electrode Length as per the Tender Specifications and
Drawing. (All Materials Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
68 9926000089 Type, Earth Electrodes for HT Feeder Pole Having 3000 mm No
Electrode Length as per the Tender Specifications And
Drawing. (All Materials Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip having hot dip-
galvanized-zinc coating of 80-100 microns without any joints
or welding. Both the end of the GI strip should be connected
with GI nut bolts and required fabrication work for giving
69 9926000090 separate earthing connections to(1) Neutral of the Meter
transformer(2) MS structures of the transformer center
(Approximately 25 meter GI strip per transformer centre- as
per requirement and instruction of Engineer in- charge) (All
Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of
1.25" diameter for covering GI strip with UV protected Cable
Ties of 550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for GI strip
covering per transformer centre -as per requirement and
instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conductor sleeve for Busbar
to Drop out Fuse and Drop
71 9926000093 out fuse to Transformer H.T. including Busbar (12 mm Per TC
sleeve) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar
to Drop out Fuse and Drop
72 9926000100 out fuse to Transformer H.T. without Busbar (12 mm sleeve) Per TC
as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar
to Drop out Fuse and Drop
73 9926000094 out fuse to Transformer H.T. including Busbar(15 mm Per TC
sleeve) as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar
to Drop out Fuse and Drop
74 9926000101 out fuse to Transformer H.T. without Busbar(15 mm sleeve) Per TC
as per technical
specification. (All Materials will be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-flammable)
material with Weather
resistant, Non-conductive bird guard OD=300 MM, ID=33
MM, Width =1.25 MM, one
side cut from ID to OD. (All Materials will be supplied by
Providing and fixing of LT Terminal protectors i.e. Re-
useable boot (LT Side 1.1 kV) including LT (1.1 kV)
insulating taps. All live part at LT side shall be covered with
fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated material
for fitting nylon net shall be provided by DGVCL)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
TOTAL ESTIMATED AMOUNT OF SCHEDULE B1
1 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree 57
Replacement of old jumpers & providing new double
jumpers with 8" binding & capsuling with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No. 633
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No. 18
Pin binding of conductor 11/22kv Pin insulator per pole in
5 9924000007 costle area with cleaning . No. 41
6 9924000008 Pin binding of conductor LT shakel insulator No. 14
7 9924000009 Replacement of one/both disc.insulator at strain pole No. 161
8 9924000010 Replacement of LT shackle insulator at cut point No. 31
9 9924000011 Refixing of V cross Arm No. 61
10 9924000012 Replacement of V cross Arm No. 210
11 9924000013 Refixing of Top fitting in proper position No. 41
12 9924000014 Replacement of Top fitting No. 51
13 9924000015 Replacement of LT cross Arm No. 105
Providing DO fuse on DP with carting & jumpuring(ONE DO
Numburing of pole with paint by preparing back ground of
15 9924000017 one colour and have lettering(height 3" * width 0.5") using No. 46
16 9924000018 Fixing of MMB(1PH.) at consumer end No. 86
17 9924000019 Fixing of MMB(3PH.) at consumer end No. 128
18 9924000020 Replacement of (1ph.) meter for Urban area No. 51
19 9924000021 Replacement of (1ph.) meter for Rural area No. 74
painting consumer no. on MMB (Urban) (with letter size
height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter size
height 40mm* width 8mm)
22 9924000024 Replacement of deteriorated Single phase Service line No. 93
Fixing of new dist. Box with complete wiring including
clamps,nut bolts etc.
Reparing of guarding involving reshaping of bearer wire
cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP structure
Painting of steel fabricated material of RSJ pole mounted
transformer double pole structure with paint
Painting of steel fabricated material of RSJ single pole with
painting of steel fabricated material of PSC Single pole (HT
line) with paint
painting of steel fabricated material of PSC DO DP double
pole with paint
painting of steel fabricated material of PSC double pole at
pole mounted transformer with paint
31 9924000033 Providing line seperater single phase No. 11
32 9924000034 Providing line seperater three phase No. 31
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
Replacement / Providing of stay insulator along with
adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist. Box with
new up to 100KVA capacity & crediting it to store.
Replacement of deteriorated /providing LT dist. Box with
new above 100KVA capacity & crediting it to store.
36 9924000038 Adjustment of tension in stay wire No. 158
37 9924000039 Refitting of LA No. 31
Converting pin point to Shackle point including dismentaling
& restringing etc.
replacement of 11KV Pin insulator with providing new
double pin binding
replacement of 22KV Pin insulator by new 11kv pin insulator
with spares & providing new double pin binding
Providing 11kv double disc insulators with binding &
Replacement of existing 11kv conductor (all size) with new
double pin binding
43 9924000046 Plumbing of PSC Pole with straightening at pin point No. 287
44 9924000047 Plumbing of PSC Pole with straightening at tension point No. 373
Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling
of stone Murrum etc.
Providing new 11kv AB /GO switch with fabrication and
insulated colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing new
insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line with using
PVC reel insulators etc
Labour charges for replacement /providing of MMB &
service with all accessories for three phase connection
Labour charges for replacement /providing of MMB &
service with all accessories for single phase connection
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE)
51 9924000055 25/63/100/200 KVA with all fabrication & creditig the old No. 5528
material to store
52 9924000056 Disconnection from LT pole 1 phase No. 46
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No. 66
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole &
crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole &
crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC cable (1
Reconnection of service line complete with PVC cable (3
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr
in length) with salt and coal 10kg each, including pvc rigid
60 9924000064 pipe 20mm dia( 1.5mtr length) to pass exposed part of G.I. No. 816
wire at consumer end with all materials, earth resistance
should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm single strand
copper insulated cable with cable nail clip for spiral type
earthing at consumer end. The end of G.I. no 8 is to be
connected by connector with copper cable of which other
61 9924000070 per meter 30
end shall be connected to the earth terminal of meter box.
This item shall be used in location where there is more
distance between earth terminal and earthing terminal of
meter. (All materials supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of
62 9924000065 dismantling charge of existing bare conductor and crediting KM 8922
in to store & dismentaling of service line from LT bare
conductor and to provide service connection on Aerial
Bunch Cable by insulated pierceing connectors through
service connection box complete as required & directed by
Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35
SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of
63 9924000066 dismantling charge of existing bare conductor and crediting KM 22303
in to store & dismentaling of service line from LT bare
conductor and to provide service connection on Aerial
Bunch Cable by insulated pierceing connectors through
service connection box complete as required & directed by
Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to
64 9924000067 pin insulator,preparing shackle point,jumpers etc. and KM 44608
inclusive of dismantling charge of existing bare conductor
and crediting in to store complete as required & directed by
Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to
65 9924000068 pin insulator,preparing shackle point,jumpers etc. and KM 55019
inclusive of dismantling charge of existing bare conductor
and crediting in to store complete as required & directed by
Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ
MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and crediting
66 9924000069 in to store & dismentaling of service line from LT bare KM 15613
conductor and to provide service connection on Aerial
Bunch Cable by insulated pierceing connectors through
service connection box complete as required & directed by
Engineer in Charge.
TOTAL ESTIMATED AMOUNT OF SCHEDULE B2
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0023/02/2026 Approved Date: 04-02-2026
1. DGVCL will provide key material like M.S. materials,ABC/Bare
conductors,PSC/RSJ Poles,Insulators,Fabricated materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved drawing and by
welding rods confirming to the relevent ISI specification and as directed by
Engineer in charge.
3.Necessary electricity connection for fabrictated items shall be provided by
DGVCL on payment of required charge for connection & electricity bill of the
same shall be paid by the agency. Deputy Engineer (Tech)
4.All the rates are inclusive of PF and Exclusive of GST applicable time to time. DGVCL
5.All steel material are to be painted as below: Sachin Division
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ
poles & steel fabricated materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted
for the RSJ poles & steel fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent
quality silver paint) is to be properly painted on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
Minimum 500000.00 Lacs work carried out by contractor.
Total of Schedule B1 + B2 + B3 + B4 is Rs. TOTAL
File No: DGVCLSDUR/MSC/e-file/4523/2026/0172/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NOTICE INVITING TENDER.pdf
2. Bid Document ok (1).pdf
3. Detail Technical Specification ok.pdf
Erection Work Schedule B1 and B2.pdf
UG Cable Schedule B3 and B4.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .