| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC KARIMPUR KHAIRUL ALAM KARIMPUR SCHOOLPARA BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L1 | Accepted-AOC AOC | |
| 2 | L2₹26.0 L+₹1.2 L (4.65%)Rejected-Finance SADARGHAT LALBAGH MURSHIDABAD 742149 | MURSHIDABAD | WEST BENGAL | 742149 | L2 | Rejected-Finance L2 | |
| 3 | L3₹31.0 L+₹6.2 L (24.9%)Rejected-Finance KARIMPUR NAIHATI BIRBHUM 731243 | BIRBHUM | WEST BENGAL | 731243 | L3 | Rejected-Finance L3 | |
| 4 | L3₹31.0 L+₹6.2 L (24.9%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 5 | Rejected-Technical 28 11 DHAVJI ROAD NEAR OUR LADY OF MOUNT MARY CHURCH ELLA OLD GOA 403402 | NORTH GOA | GOA | 403402 | - | Rejected-Technical Proper documents not submitted |
Tender Value
₹29.6 L
EMD Value
₹88,871
Closing Date
19 Feb 2025, 10:00 amClosed
The Superintending Archaeologist
Office of the Superintending Archaeologist, ASI, Raiganj Circle 2nd Floor, BSNL Admin Building, Karnajora, Raiganj, Uttar Dinajpur, West Bengal
AS PER NIT
2025_ASI_846726_1
02 / HDPM / 2024-25
Open Tender
Civil Works
Works
60 days
Hazarduari Palace Museum
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
SA ASI
₹88,871
Yes
13 Mar 2025
29 Jan 2025
20 Feb 2025
30 Jan 2025
19 Feb 2025
30 Jan 2025
Amount
Execution of work under following items
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer- in-charge at the Armoury gallery no. -1 &2 of the Murshidabad Hazarduari Palace Museum.
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (1.48kg /- sqm)
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge .
Providing and fixing incomer panel box (incomer 01 no.-box 63A, 4 P, MCB, outer - 25 A, TP,MCB,-2 nos, 6A to 25A ,SP.MCB-18 nos, 16 way VTPN MCB DB(DD) IP-54.- 01 no.
Providing and fixing 32A 4P MCB WITH ENCLOSURE BOX
Providing and fixing 25 sqmm x 4C AL, AR CABLE XLPE
Providing and fixing 63 sqmm x 4C AL, 21/2" AR CABLE END TERMINATIONS WITH DC TYPE GLANDS.
Wiring for light /power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 no. 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (Conduit Wiring of Primary & Secondary light points for Lighting using 2 X 1.5Cu for P & N + 1 X 1.5PE from Switch Board to Lights.)
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.( Conduit Wiring of Main Circuit for Lighting using 2 X 2.5Cu for P & N + 1 X 2.5PE from DB to Switch Board.)
Wiring for light / power plug with 2x4 sq. mm FRLS pvc insulated copper conductor single core cable in surface / recessed steel conduit along with 1 no. 4 sqm mm FRLS pvc insulated copper conductor single core cable for loop earthing as required .
Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed steel conduit as required
Dismantling of Electrical Room DB,Cable,Light fixture, fan, Conduit & etc.
Supplying and fixing 12 MODULAR (16 gauge) MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
Supplying and fixing 3 MODULAR (16 gauge) MOOULAR BASE & COVER PLATE on existing modular melal boxes etc as required .
Supplying and fixing 4 MODULAR MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
Supplying and fixing 6 MODULAR MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
Supplying and fixing 8 MODULAR rectangular (stainless steel metal box) MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
Supplying and fixing MOOULAR SWITCH: 6A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed .
Supplying and fixing MODULAR SWITCH : 16A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed
Supplying and fixing MODULAR SOCKET & PlN : 6/16 A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed
supplying and fixing MODULAR SOCKET 3-PlN : 6A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed
Supplying and lixing MODULAR blanking PLATE on existing modular plate & switch box including connections but excluding modular plate etc. as required
Providing and fixing MODULAR AC STARTER SWITCH including all complete as per directed
Providing and fixing 12W LED DOWN LIGHT FIXTURES INSTALLATION ONLY including all complete as per directed
Providing and fixing 36W LED 2' X 2' LIGHT FIXTURES INSTALLATION ONLY including all complete as per directed.
Providing and fixing 8 SWG GI WIRE FOR EARTHING CONTINUITY including all complete as per directed
Supply & installation of 25 mm dia PVC Flexible pipe including all complete as per directed
Supply & installation of 25 mm dia PVC MMS conduit pipe including all complete as per directed.
Temporary Construction Power and Lighting Arrangement with manpower for maintenance as required for the working site
Wall Cutting Charges including all complete as per directed
RADHA ENGINERINGWORK (BID ID -3172755)
ASHIS BISWAS (BID ID -3170868)
ABDUL SARTAZ (BID ID -3172576)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .