| 1 | L1₹15.6 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC L1 bidder | |
| 2 | l2₹17.4 L+₹1.2 L (7.56%)Rejected-Finance | l2 | Rejected-Finance unsuccessful bidder | |
| 3 | L3₹17.8 L+₹1.6 L (9.87%)Rejected-Finance VISHNU NIVAS IRUMBA ARUVIKKARA PO TRIVANDRUM 695564 | THIRUVANANTHAPURAM | KERALA | 695564 | L3 | Rejected-Finance unsuccessful bidder | |
| 4 | L4₹18.9 L+₹2.8 L (17.0%)Rejected-Finance REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L4 | Rejected-Finance unsuccessful bidder | |
| 5 | L5₹19.5 L+₹3.3 L (20.6%)Rejected-Finance | L5 | Rejected-Finance unsuccessful bidder |
Tender Value
₹15.0 L
EMD Value
₹29,960
Closing Date
1 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
REPAIR REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INCLUDING PANEL BOARD STRUCTURES AND CERTAIN REPAIRS TO AIRFIELD LIGHTS AT CERTAIN UNITS AT SHANKHUMUKHAM MUKKUNNIMALA AND MUTTATHARA UNDER GE AF TRIVANDRUM
2023_MES_634806_1
8453
Open Tender
Electrical and Maintenance Works
Works
270 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹29,960
Yes
18 Mar 2024
29 Dec 2023
3 Feb 2024
29 Dec 2023
1 Feb 2024
12 Jan 2024
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out in hard dense soil complete all as specified.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable not exc 1.5m in depth and getting out in soft loose soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushioning of cable and refilling of trench with normal excavated soil all as specified and directed
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply and lay in trenches burnt clay building bricks sub-class ‘B’ size designation 75 for cable protection all as specified and as directed.
Laying only in trenches burnt clay building bricks sub-class ‘B’ size designation 75 obtained from item No for cable protection all as specified and as directed.
Supply and filling in repair Transformer oil of dielectric strength not less than 40 KV, conforming to IS-335 in Servo voltage stabilizer/Transformer all as directed.
Supply & filling in repair silica gel inside breather assembly of transformer all as directed.
Supply and fix in repair Cable jointing kit for 11 KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, Al conductor cables, earthed system of size 120 Sqmm all as specified and as directed
Material and labour for testing the dielectric strength of transformer oil of the transformer/servo voltage stabilizer installed at various sub stn at/on floor/pole before dehydration and dehydrating and filtering the transformer oil with dehydration machine to achive dielectric strength of the oil upto 50 KV at 2.5mm gap/ as as per IS standard, complete all as directed. Note : The transformer dehydration machine and dielectric strength testing machine shall be arranged/brought by the contractor at site and the rate for the same shall deemed to be included in the item rate.
Supply & fixing breather assembly suitable for outdoor type transformer with silica gel including taking down u/s from the transformer all as directed.
M&L for Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom,class 10 complete including dismantling the existing PCC/steel pole including taking out embedded portion and making good disturbed ground all as specified and directed.
M&L for painting on steel tubular poles of height 7.5 Mtr above gound level by applying two coats of Aluminium paint over one coat of red oxide primer on street light pole bracket /clamps terminal box etc including applying two coats of cement based paint over one coat of suitable primer for coping and writing pole number in black and white Paint complete all as specified and directed.
M&L for painting on PCC poles of height 7.5 Mtr above gound level by applying two coats of exterior weather coat paint over one coat of suiable primer on existing poles including copping and writing pole number in black and white Paint complete all as specified and directed.
M&L for preparation of old painted body surface of HT/LT indoor/out door panel / feeder piller box and spray painting with two coat of synthetic enamel paint as per existing colour over one coat of zinc chrome primer to inside and outside of the body of LT panel as directed by the Engr-in -Charge complete all as specified and directed.
Taking down old rusted monkey cage on street light pole made out of wire mesh and welding and strengthening with additional length of angle iron of suitablle size and wire mesh as required and refixing in position after painting with one coat of aluminium paint over one coat of suitable primer complete all as specified and directed by engr-in- charge
M&L for painting of monkey cage on steel pole with two coats of synthetic enamel paint of approved shade over one coat of zinc chrome primer including removing of rust/foreign materials from surface of monkey cage with wire brush complete all as specified directed.
Comprehensive maintenance of Reciprocating type High Pressure Air compressor capacity 7.5 HP . Make: ELGI including replacement of filter elements and complete servicing of lubricating oil strainer, suction filter and minor components, inter cooling and after cooling system for functional checking all as specified and directed.
Supply, install, test and commissioning CPRI approved outdoor type LT feeder pillar box KIOSK type, platform mounted, factroy made, totally enclosed, dust and vermin proof IP55 made of 3.15 mm CRCA sheet MS flat and angle support/frames, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and confirming to IS 5039 /IS 8623 and other relevent IS /IEC codes and CPRI type tested, duly powder coated both internally and externally suitable for 415 Volts 50 HZ 3 phase 4 wire system and comprising of the following features and accessories /components installed on existing PCC platform with nut bolts all as specified and as directed including taking down old LT Panel:-
BUSBAR:- 400 Amps rated copper busbar 03 Nos & 200 Amp 01 No TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite /DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance.
OUTGOING:- i) MCCB 4 pole 63 Amps capacity 25 kA braking capacity, 415 volts, 50 Hz, fixed thermal magnetic type -06 Nos ii) MCCB 4 pole 40 Amps capacity, 16KA braking capacity,415 volts, 50 Hz fixed thermal magnetic type -03 Nos (iii) 65A TP Contactor -01 No (iv) 24 Hours digital timer - 01No
Servicing/ maintenance of UPS capacity 30 KVA and replacement of following parts including testing after completion of work all as specified and directed. (i) Inverter card M080 - 01 No (ii) DC-DC Card M10D - 01 No (iii) IGBT Driver card M 27D - 01 No (iv) IGBT 100A - 02 Nos (v) AC Capacitor 100Mfd,440V - 01 No
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundations, filling and mass concrete for erection of poles complete all as specified.
M&L for Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in coping including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete all as specified and directed.
Taking out damaged butt hinges and locking arrangement from out door type LT Panel door and M&L for welding new hinges and locking arrnagement on the panel door inlcuding denting/adjusting the door for proper closing and Preparing surface smooth all as specified and directed.
Supply and lay in trenches/under roads/crossings or fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables including taking out old unserviceable pipes and remove from site :- Note : Payment for excavation and earth work shall be paid for separately under relevant items of this Schedule.
80 mm dia
50 mm dia
Taking out old defective under ground cable from trenches floor / road / wall / pipe/ pole of any size and description, for repairing complete all as specified and directed.
Labour only for re-laying the serviceable part of cables of any size taken out under item No 25 above after repairing defects / making joints etc in same trench or any other location, complete all as directed. Note : 1. The excacation, earth work, sand cushioning, protection cover, and cable joints etc will be measured and paid seperately under respective items of this Schedule.
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area including removing of old U/S cable all as specified and directed by the Engr-in-Charge :-
120 Sqmm 3.5 core
95 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
10 Sqmm 4 core
10 Sqmm 2 core
Earthing complete with Copper earth plate electrode 60cm x 60cm x 3 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting copper strip of size 20mm x 3mm from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of brass or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(7.5 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing on completion till to achieve desired ER value all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Earthing complete with Galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI strip of size 32mm x 6mm from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(7.5 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing on completion till to achieve desired ER value all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Earthing complete with Galvanised Iron earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI earth lead wire 4mm dia from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 20 mm bore GI light grade pipe for protection of earth lead from earth plate(7.5 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing on completion till to achieve desired ER value all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Attending, Repairing/restoring of electric power supply in the AF Stn 17 FBSU and its lodger Unit area, after identifying fault in HT 11 KV or LT 1100 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size. The work also include checking, identifying and rectifcation of LT/HT UG Cable faults at AF Area as and when directed. Note : (i) Major items required to be replaced/repaired will be measured under relevant items of schedule (ii) Excavation and earth work if required will be measured separately under relevant items of schedule. (iii) Complaints will be given in person or through telephone by AGE/JE E/M. The contractor shall attend the complaint immediately and shall report the Engr-in-Charge/JE E/M after completion with in 6 hrs
(iv) Penalty of Rs 1000.00 per Job shall be applicable to the contractor if the complaint is not attended within 6 hrs. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regards shall be final and binding. (v) In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC. (vi) Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon to collect routine/urgent works till completion of work. (vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.
Supply and replacement of cable jointing kit for 1100 volt (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10-50 sq mm after taking down old unserviceabl one
Supply and replacement of cable jointing kit for 1100 volt (Earthed) grade cable for End Termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70-150 sq mm after taking down old unserviceable one.
Supplying and laying in repairs synthetic Rubber insulated mats 2.5mm thick for voltage up to 11KV for electrical purpose as per IS 15652-2006 (Superseding IS 5424) suitable for electrical shock safety of size 2m x1m all as specified and directed.
Supply and fixing in repairs of digital type voltmeter 0-500 volt 96x96 mm square type all as directed and specified
Supply and fixing in repairs of digital type ammeter 0-400 Amp 96x96 mm square type all as directed and specified
Supply and fixing in repairs of digital type ammeter 0-200 Amp 96x96 mm square type all as directed and specified
Supply and fixing in repairs of digital type ammeter 0-100 Amp 96x96 mm square type all as directed and specified
Supply and fixing of CT 400/5 , copper wounded with suitable wiring for digital type ammeter for 3 phase connection after taking down old one.
Supply and fixing of CT 200/5 , copper wounded with suitable wiring for digital type ammeter for 3 phase connection after taking down old one.
Supply and fixing of CT 100/5 , copper wounded with suitable wiring for digital type ammeter for 3 phase connection after taking down old one.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 63A, 3 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 100A, 3 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 63A, 4 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 100A, 4 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 200A, 4 pole, breaking capacity 35KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 250A, 4 pole, breaking capacity 35KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair on load change over switch 100A, 4 Pole all as specified and directed.
M&L for replacement of street light bracket for PCC pole of 9 mtrs height made of 40 mm dia GI tubing light grade, 1.2 metre long, bent to shape fixed to pole with 50mm x 6mm Flat iron clamps with nuts and bolts including painting two coats of aluminium paint over a coat of zinc chrome primer all as directed.
Taking out unserviceable UG cables and Supply and laying only in trenches or passing through pipes/ poles etc LT XLPE cable heavy duty 1100 Volts grade 16 Sqmm 4 core with aluminium conductor of the following connections with provn of cable lugs and glands as required.
Taking down the existing conventional bollard fittings and S & F energy saving bollard luminaire 8 W capacity LED type prewired with IP 65 protection including provision of powder coated hollow pipe or bollard all as specified and as directed.
Taking down the existing Flood light fittings and S & F New High Power LED flood light fitting to ensure uniform distribution with die cast aluminium IP 66 flood light of capacity 150W LED fittings with suitable fixing accessories all as specified and as directed.
Supply and fixing Cable Junction box made out of polycarbonate material IP66 with metric knockouts for cable entry for 10-16 Sq mm cable size 155x210x92mm including 1 No MCB 10 Amps with DIN bar and 4 Nos FRP insulators and fixing the box to street light pole made of 25x 3mm flat iron with clamps, nuts and bolts complete as per all as specified and directed by Engineer-in-charge
S & F in repairs astronomical and digital time switch suitable for operation on 230 Volts AC complete all as specified and directed.
S&F in repairs PVC copper cable, 3 core, multi stranded of size 2.5 Sqmm in and including PVC rigid conduit of size 20mm medium grade with all accessories as per site requirement fixed on pole with GI plate of size 20x3mm and GI nut,bolt and washer etc, all as specified and directed.
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation with four foundation bolt embedded in the PCC for fixing of GI street light pole of 8 mtr height, with GI nut and washer of suitable size including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete all as specified.
Supply and installation by replacing the old rusted steel tubular pole with Polygonal/Octagonal GI pole, hot dip galvanised (thickness of galvanisation not less than 65 microns), thickness of sheet not less than 3mm, thickness of base plate not less than 16mm, pole bottom dia 130mm and top dia 70mm with four GI foundation bolts of suitable length and dia, GI bracket at top suitable to fix six numbers of 150watt flood light fittings with GI nut bolts and washers etc, length of pole 8 metres all as specified and directed. (Note :- Excavation,earth work & PCC etc shall be measured and paid seperately under relevent items of this schedule)
Shifting of existing polygonal GI pole from PCC foundation by loosening nuts from foundation bolt and fixing only on new location including supply and fixing GI bracket of size suitable to fix six LED flood lights of 150watt with GI nuts,bolts and washers etc all as specified and directed. (Note :- Excavation,earth work & PCC etc shall be measured and paid seperately under relevent items of this schedule))
GRAND COOL SOLUTIONS
VISHNU
DEFT GROUP ELECTROMECHANICAL
General Engineering and Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .