Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.1 LAccepted-AOC | ₹79.1 L | L1 | Accepted-AOC Techno-Commercially Accepted L1 Bidder |
| 2 | L2₹1.1 Cr+₹28.9 L (36.6%)Rejected-Finance | ₹1.1 Cr+₹28.9 L (36.6%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Submission of detailed scope of work as asked in technical bid and shortfall document |
| 4 | Rejected-Technical | - | - | Rejected-Technical 1)Not qualified as per PQC clause 5.1 (2)Submitted work experience document is not meeting criteria of similar nature of work as defined in tender document PQC clause 5.2 |
| 5 | Rejected-Technical ARGADA RAMGARH JHARKHAND 829101 | RAMGARH | JHARKHAND | 829101 | - | - | Rejected-Technical PQC 5.2 Not satisfied - Bidder did not submit 3 no of work orders above 34.4 lakhs / 2 no work orders above 43 lakhs / 1 no work order above 68.8 lakhs |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
13 Feb 2023, 4:00 pmClosed
Sr VP HURL Sindri
HURL Sindri, Old FCIL Complex, Sindri, Dhanbad-828122
Supply, Erection and Commissioning of new 11 kV Overhead line along with 4-pole Structure from Khalsa More to Settling Tank and Intake Well facilities
2023_HURL_736465_1
HURL/Sindri/CnM/22-23/2217
Open Tender
Electrical Works
Tender cum Auction
90 days
Sindri
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1 L
Yes
10 Jul 2023
21 Jan 2023
14 Feb 2023
21 Jan 2023
13 Feb 2023
21 Jan 2023
21 Jan 2023 - 13 Feb 2023
Amount
Supply, Installation ,Erection & Commissioning of the followig items
Rail Pole 60 kgs per mtr - 13 meter
ACSR Dog conductor (100 sq. mm.) Including 5% sag.
11kv Pole Top Bracket 50x8 mm flat [GALVANIZED]
11 KV Back Clamp for top bracket [GALVANIZED]
11 KV V cross arm (75x 40x 6 mm), 7.14 kg per mtr [GALVANIZED]
11 KV Back Clamp for "V" cross arm [GALVANIZED]
Support Clamp for 11 KV 'V' Cross Arm [GALVANIZED]
11 KV Cross bracing for D P Structure[GALVANIZED]
DP Channel Support clamp (50x6 mm - Galvanized)
11 KV Pin Insulator (Polymer) with Pin Including support for jumper
11 KV Disc. Insulator (Polymer) 45 KN with H/W
11kV 200A, HG Fuse Set
Structure for HG Fuse Set (Galvanized)
11 KV 3 pin type AB switch/Isolator 400 Amp
Structure for 33 & 11 KV Isolator [Galvanized]
11 KV Lightening Arrester (9KV,10KA, ClassII)
Stay set complete (1800x16 mm) with stay wire 7/10 SWG 8 kgs & Guy Insulator
11 KV Angle stay clamp (50 x 10 mm) [GALVANIZED]
P G clamp for 232/150 sq. mm. conductor
Aluminium binding wire 5 sq.mm
GI Wire No. 10 for earthing
11kV Earthing pipe 20 mm 2.5m long
GI Stay Wire No. 7/10
Stone Base Plate for 11KV
Anti-climbing Device(Barbed wire) s x 12 SWG
11 KV Back Clamp for line DP Channel [GALVANIZED]
11 KV D.P Channel support clamp (50x6 mm) (GALVANIZED)
11 KV D.P Channel (100x50x6 mm) 1.3 Meter long (GALVANIZED)
Danger Board 11KV
Providing P.C.C.M -150 in nominal mix(1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of EIC
Design, Supply, Installation, erection, testing and commissioning of 4 pole structure with two sets of incomer and one set of outgoing along with required bracing, cross arm etc for supporting the pin/strain type insulators (polymer), Guy wires as required, GOD, DO fuses (3No) with necessary 10kA lightning arresters, earth switch, Insulators, Jumpers, Anti climbing device, Danger board etc suitable for receiving power from Upstream SS as per enclosed specifications, SLD, CEA guidelines etc including excavation and grouting/coping of poles, painting with primer, paint, earthing as per IE rule, & IS 3043 etc this shall also includes installation of chain link fencing of 2.5 mtr height around HT Yard comprising of 100x50x6 mm MS channels at every 1.8 mtr centres, 65x65x6mm angles, 8 swg GI mesh of 50x50 mm opening, washers, nuts, bolts, locknuts etc & filling the HT yard with well graded crushed stone aggregate varying in size from 20mm to 50mm mixed with clean sand in the ratio 2.5 part of stone aggrgate to 1 part of clean sand having less than 75 micron size, compacting in 30 mm thick layers using vibratory rollers to achieve a unit weight of at least 2.2T/cu.m (IS 10028) as per enclosed specifications, SLD, CEA guidelines etc
Bidder Name
Amount in Words
M/s Surendra Singh
M J ENGINEERING
M J ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .