| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.8 L+₹15,208.39 (0.32%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹48.9 L+₹1.2 L (2.53%)Rejected-AOC LANE NO 02 B BLOCK MANDAKINI VIHAR SAHASTRADHARA ROAD DEHRADUN UTTARAKHAND PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹49.0 L+₹1.3 L (2.76%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹49.6 L+₹2.0 L (4.09%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
23 Jul 2021, 6:00 pmClosed
GE 871 EWS
Joshimath 246443
PROVN OF HARD STANDING, SHED, POWER SUPPLY AND MEDICAL OXYGEN GAS PIPE LINE SYSTEM FOR THE INSTALLATION AND COMMISSIONING OF OXYGEN GENERATION PLANT AT JOSHIMATH
2021_MES_458579_1
8610/E8
Limited
Civil Works
Works
120 days
JOSHIMATH
As per tender
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹94,600
Yes
29 Jul 2021
9 Jul 2021
26 Jul 2021
9 Jul 2021
23 Jul 2021
16 Jul 2021
9 Jul 2021 - 15 Jul 2021
Amount
Rough excavation nexc 1.5 m deep and getting out in hard dense soil all as specified and directed
Rough excavation nexc 1.5 m deep and getting out in hard rock using mechanical means or chisel cutting all as specified and directed
Excavation over areas nexc.1.5m deep and getting out in hard dense soil all as specified and directed
Excavation over areas nexc.1.5m deep and getting out in hard rock using mechanical means or chisel cutting all as specified and directed
Excavation in trenches nexc 1.5m wide and nexc 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes, nexc 10 sqm on plan and getting out in hard dense soil all as specified and directed
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil all as specified and directed.
Excavation in trenches nexc 1.5 m wide and nexc 1.5 m in depth for laying of underground cable pipe and getting out in soft disintegrated rock and removing at a distance of 50 m from site all as specified and directed.
Excavation in trenches nexc 1.5m wide and nexc 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes, nexc 10 sqm on plan and getting out in hard rock using mechanical means or chisel cutting all as specified and directed
Excavating in post holes (or similar holes) each nexc 0.50 cum and getting out in hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers nexc 25cm in soil all as specified and directed.
Removing excavated material to a distance nexc. 50 m and depositing where directed at a level nexc. 1.5 m above the starting point all as specified and directed.
supply and lay local sand dry, filling in trenches around under ground cable all as specified and directed.
M&L for hand packing with broken stone or boulders (of any thickness) at back of walls over arches and raising (or lowering) to the required level all as specified and directed.
M&L hardcore of gauge nexc. 63mm (broken stone or boulders), deposited, spread and levelled in layers nexc. 15 cm thick, watered and rammed to a true surfaces all as specified and directed
M&L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for making good the disturbed surface by filling to match with existing surfaces all as specified and directed.
M&L PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40m graded crushed stone aggregate) as in foundations, filling and mass concrete all as specified and directed
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in bonders (for stone walling) set in CM 1:6 all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping including form work all as specified and directed.
M&L RCC M-25 grade design mix (using 20 mm graded crushed stone aggregate) in foundations, footings, plinth beams, bases for columns all as specified and directed.
M&L for walling of random rubble masonry uncoursed or brought upto courses, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and directed
M&L extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face 40 mm for stone all as specified and directed.
M&L precast cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate as in solid building blocks exc 10cm in width and setting in CM (1:6) all as specified and directed.
Supply and lay new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable all as specified and directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns and plinth beams, and similar work for rough finished surfaces of concrete all as specified and directed.
M&L mild steel TMT bars in reinforcement 10mm dia and over cut to length bent to shape required including cranking binding spirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L mild steel TMT bars in reinforcement 8mm dia and over up to 10mm dia in stirups cut to length bent to shape required including cranking binding spirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
S&F steel work in tubular trusses, purlin including special shaped washer, using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240all as specified and directed.
S&F MS tube as in post, columns complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade Yst-240 including fabrication, erection and fixing in position all as specified and as directed.
S&F plates (plain or chequered) channels, square, cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde- E- 250) quality- A all as specified and directed.
S&F mild steel bolts, purpose made, dia of bolt exc 12 mm but nexc 20 mm with hexagonal or square head, one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long all as specified and directed.
S&F mild steel bolts, purpose made, dia of bolt exc 11 but not exc 15 mm with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm long but not exc. 10 cm long all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection all as specified and directed.
M&L 100 mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in sub base finished even & smooth all as specifed and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finised surfaces even and smooth without using extra cement externally using water proofing powder all as specified and directed.
Supply only integral water proofing compound all as specified and directed.
M&L raised pointing to randam or polygonal rubble uncoursed or brought upto courses in cement mortar 1:4 all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint externally over a coat of primer all as specified and directed.
M&L 150mm thick PQC controlled (quality) cement concrete of minimum flexural strength 40 Kg per Sqcm in field at 28 days lower control limit (LCL) in pavement/hard standing, slabs using minimum 400 Kg of cement per cubic metre laid in bays to required gradient and camber including necessary form work all as specified and directed.
M&L for Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound 'B' complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description exc 10cm width or girth and applying two coats of 1st quality synthetic enamel paint over a coat of primer all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length fixed in walls and floors or trenches as an weep holes of retaining wall all as specified and directed.
M&L point wiring in PVC conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for One light/bell point controlled by one, one way switch
All as per item No 45 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 45 above but one socket outlet 5 pin 5/6 Amps on the same board with one, one way switch.
All as per item No 45 above but for socket out let, 15/16 Amps on independent board with 4 sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed. Make:Anchor/Havells/Legrand
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed. Make:Anchor/Havells/Legrand
S&F socket out let 5 pin 5/6 Amps all as specified and directed. Make:Anchor/Havells/Legrand
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed. Make:Anchor/Havells/Legrand
S&F ceiling rose 2/3 terminals 65x25 mm dia polycarbonate isolated all as specified & directed. Make:Anchor/Havells/Legrand
S&F LED tube light fitting bright 18 watt, slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells Cat Pt No LHEXBLP7PN1W018 or equivalent of Philips/Bajaj
S&F building security light fitting with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- Havells Cat Part No: ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent CG/ Bajaj/HPL
Supply and fix DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar with encosure blank plates for unused all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
Supply and fix MCB 6-32 amps, 10 KA, SP 240 volts 'C' series all as specified and directed Make:-Legrand/Schneider/ Havells
Supply and fix MCB 63 amps, 10 KA, DP 240 volts 'C' series all as specified and directed Make:-Legrand/Schneider/ Havells
M&L earthing complete with galvanised steel earth plate electrode of size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of the earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata met at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600mm x 600 mmx 6mm thick buried directly in ground, earth pit not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.50 m deep below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion. NOTE :- GI earth wire and protection pipe beyond 7.5 m will be measured and paid separately.
M&L for earthing complete with using copper earth plate (electrode) 600 mmx 600 mm x 3.15mm thick buried directly in ground, earth pit not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 20x3 mm copper earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, copper earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as watering pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion. NOTE :- GI earth wire and protection pipe beyond 7.5 m will be measured and paid separately.
M&L sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 20mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per the existing all as specified & directed. Make:- Single core copper conductor cable Havells/ FinoLex/PolyCab Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid as one unit length.
S&F bed head panels (with 3 outlets, switch & socket) (3 Feets) including all accessories such as rawl plug, hold fastner, nut, bolts & washers and complete electrical connection with making good surface wall all as specified and directed.
S&F bed head panels (with 6 outlets, switch & socket) (4 feets) including all accessories such as rawl plug, hold fastner, nut, bolts & washers and complete electrical connection with making good surface wall all as specified and directed.
S&F 22 mm dia copper pipeline of thickness 0.9mm, installing with complete accessories and laid on GI tray & supported with mild steel angle iron all as specified and directed.
S&F 12 mm dia copper pipeline of thickness 0.7mm, installing with complete accessories and laid on GI tray & supported with mild steel angle iron all as specified and directed.
S&F Flow meter with humidifier bottle for bed head panel all as specified and directed.
S&F Oxygen gas pressure alarm with analogue gauge all as specified and directed.
S&F sleaves foam type insulation upto 25mm dia oxygen gas pipe line including complete packing with insulation tape and mild steel clamps, nut, bolt and washer at a distance 1 metre centre to centre all as specified and directed.
S&F Manifold with presure gauge 10+10 all as specified and directed.
S&F fully automatic control panel with presure gauge, LED indication lamp, on/off switch all as specified and directed.
S&F IOX 14 regulator including complete accessories all as specified and directed.
S&F Gas valve box including complete accessories all as specified and directed.
Supply, installation, commissioning and testing servo motor control voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type (IP55 CPRI approval required) copper wound including first filling of oil of dyelectric strength not less than 40KV with suitable capacity of incoming MCCB & by pass system designed for input variation between 300 V to 415 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 volts per second and of capacity 50 KVA all as specified and directed. Make: Volina(vinetec)/AE/Aplab
M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
M&L perforated powder coated cable tray of size 25x100x25 mm, thickness 2mm for holding of oxygen gas pipe line all as specified and directed. Make: Daspar Cat Part No PPC025x0100x025G16 / Super Steel Industry / SV metals Pvt Ltd
Supply and fix light grade galvanised mild steel pipe 50mm bore with all fittings, laid under road crossing, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers all as specified and directed as for cable proction. Make :- Jindal/TATA/Prakash surya
Supply and fix GI tubes light grade, galvanised, 20mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air terminationall as specified and directed.
Supply and fixing/laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 70 sqmm 3.5 core all as specified & directed. Make : Havells/Polycab/Finolex/Universal
All as per Item No 79 here-in-before but of size 25 Sqmm 3.5 core Make : Havells/Polycab/Finolex/Universal/MEScab
All as per Item No 79 here-in-before but of size 10 Sqmm 2 core Make : Havells/Polycab/Finolex/Universal/MEScab
M&L aluminium strip 25x3.15mm with saddles and fixing screws, insulators rawal plugs for for roof conductor and fixed on wall upto test point all as specified and directed.
Supply and fix of wooden block heavy weight of size 15x15x15 cm with suitable size of insulator for fixing of air termination rod & aluminium strip of any size all as specified and directed.
Supply and fix of single pointed air termination Aluminium rod 12mm dia, 300 mm long all as specified and directed.
Supply and fix test point terminal block made of gun metal or phosphorous bronze 75x75x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90x90x90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed.
Supply and fix aluminium tubular lugs for fixing of cable end with LT pillar/panel box or with other equipment including crimping with crimping tools in the existing LT cable 3.5 core upto 50 Sqmm including necessary connection all as specified and directed. Make : Axis/Dowells/Indiana
All as per item No 87 above but aluminium lugs of size 70 Sq mm. Make : Axis/Dowells/Indiana
M&L 4 kg HCFC 123 clean Agent based Fire Extinguisher all as specified and directed. Make: Ceasefire Industries Pvt Ltd, Product Code (CF-000025) / Agni Safety India Pvt Ltd / Safex Fire Services Ltd
M&L 4.5Kg, CO2 Gas Type MS Fire Extinguisher, Trolley Mounted, Easy Weight Management, used/unused mechanism, squeeze Grip. Make: Ceasefire Industries Pvt Ltd, Product Code (CF-000063) / Agni Safety India Pvt Ltd / Safex Fire Services Ltd
M&L 6 litre stored pressure foam mist type SS body portable Fire Extinguisher. Make: Ceasefire Industries Pvt Ltd, Product Code (CF- 001122) / Agni Safety India Pvt Ltd / Safex Fire Services Ltd
M/S Electrotech Sales
M/s Ruchi Rabh associates
M.K Engineers
AKANSHA.ASSOCIATES
Sanjeev Construction Co
Ansh Enterprises
KAPOOR ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .