Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.2 L+₹6.6 L (62.1%)Rejected-AOC 1159 VILL POST LISARI MEERUT UP 250002 | MEERUT | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹17.5 L+₹6.8 L (64.3%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹17.8 L+₹7.2 L (67.7%)Rejected-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L4 | Rejected-AOC Not Lowest |
Tender Value
₹19.4 L
EMD Value
₹38,840
Closing Date
6 Feb 2024, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 249003
Spl Repair of 1.40 Lakh Gallon Semi Under Ground Water Storage Tank at Santoshi Mata Temple Water Supply Installation Under AGE (I) Lansdowne
2024_MES_636611_1
87178/LDN/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) Lansdowne
Class E cat a(i)
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Lansdowne
₹38,840
Yes
16 Mar 2024
10 Jan 2024
12 Feb 2024
10 Jan 2024
6 Feb 2024
25 Jan 2024
Amount
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for walling of random rubble stone masonry, un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
M & L for walling of random rubble stone masonry but except stones un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level).
M&L for 40 mm thick Plain Cement concrete Type - B-0 (1:2:4) (using 12.5 mm graded stone aggregate) in as in floors finished smooth complete all as specified and directed.
M & L for Chequered colored cement concrete tiles 30cm x 30cm x 25mm thick rubber finished, laid over and including screed bed or bedding layer of mortar 15 mm thick in CM( 1:4) as in floors set, jointed and pointed in neat cement slurry with grey cement and pigment including dismantling of old stone slab tiling/ tileing and removal of old materials from site to a distance not exceeding 100 meter complete all as specified and directed
M&L for Plain Cement concrete (1:4:8), Type, D-2 (using 40 mm graded stone aggregate as) in foundations, filling and mass concrete complete all as specified and directed
M&L for PCC (design mix) M-20 (using 20mm graded stone aggregates) as in foundations, base of floors and similar work complete all as specified and directed.
M & L for plain cement concrete (1:3:6), type C-2 (using 20 mm graded stone aggregate), cills, steps, parapets , copings, bond stone, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Extra over stone walling for hammer dressing to faces of stone and dressing of faced beds and joints as specified for RR walling uncoursed or brought upto courses hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40mm for lime or sand stone complete all as specified and directed.
M&L for raised pointing to RR or Polygon rubble uncoursed or brought upto course in cement mortar (1:4 ) complete all as specified and directed.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, as in weep holes complete all as specified and directed
M&L for Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 M mean radius built in CM (1:6) complete all as specified.
M & L for Injection Grouting at Construction Joints by crystalline mortar mixing in the ratio of 4.5 : 1 ( 4.5 parts crystalline mortar : 1 part water). For sealing cracks and faylty construction joints, by preparing the surface, making U-shape groove size of 25 X 25 mm and then priming the surface with integral crystalline slurry @ 0.05 kg per running meter and while the surface is tacky then filling the groove upto top edge with crystalline mortar @ 1.5 kg per running meter.Once crystalline mortar is touch dry then finally applying two coats of crystalline slurry @ 0.05 kg per running meter per coat on treated surfaces complete all as specified and directed.Make:- Asian paint/ Fosroc/ Pidilte equivalent. Note :-The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed..
M & L for rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick/stone or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note:- Water proofing liquid compound shall be measured and paid separately.
M & L for rendering 15 mm thick in CM (1:6) on stone masonry surfacses finished even & fair complete all as specified and directed.
M & L for rendering 5 mm thick CM (1:3) as in ceiling surface finished even & fair complete all as specified and directed.
Supply only liquid water proofing compound,.ISI marked complete all as specified and directed.
M&L for three coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.
M&L for applying integral crysalline slurry on vertical surface with two coats @ 0.70 Kg per sqm per coat of hydrophillic in nature for waterproffing treatment to the RCC structures like retaining walls of the basement,water tank,roof slabs, podium,reservior,sewage & water treatment Plant,tunnels/subway and bridge deck etc, prepared by mixing in the ratio of 5:2 ( 5 parts integral crystalline slurry : 2 parts water ) for vertical surface and 3 :1 ( 3 parts integral crystalline slurry : 1 parts water) for horizontal surfaces and applying the same from negative( Internal) side with the help of synthetic fibre brush. The material shall meet the requirement as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90 % compared with control concrete as DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Enginner-in-charge.The product performance shall carry guarantee for 10 Year against any Leakage.Make:- Asian paint/ Fosroc/Pidilte/equivalent .Note:-The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work.
Supply and mixing integral Crystalline Admixture to be added with the RCC work with a ratio of 1.0 % (minimum) to the weight of the cement content per cubic meter of concrete or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirement as specified in ACI-212-3R-20101 i.e by reducing permeability of concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure.The crystalline admixture shall be capable of shelf-healing of cracks up to a width of 0.50 mm.The work shall be carried out all complete all as specified and directed by the Engineer-in-charge.The product performance shall carry gurantee for 10 year against any leakage. Make:- Asian paint/ Fosroc/Pidilite/ equivalent. Note:-The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work.
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Note :-The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work.
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.
Dismantling post struts (wood, steel or RCC) any description incl taking out embeded portion & making good disturbed ground ,post embeded in concrete /masonery etc complete all as specified and directed
Dismantling fencing wire mesh any type complete all as specified and directed
S & F Joist, channel, angle, tee/flat or other sections, including cutting tops to shapes as directed drilling holes ,notching for wire etc and simillar work conforming to Fe 290 Gde-E-165 etc all as specified and directed
Fixing only Chain link fencing in patchs including line wires any mesh size and type to any type of standard rail ,staining bolts etc ncluding provn of binding wire complete all as specified and directed.
Supply only Chain link MS glavanised fencing any size or type as required at site complete all as specified and directed.
Supply only 8 to 10 mm dia mild steel round bar for line wire of Chain link fencing complete all as specified and directed.
S & F mild steel screw bolts (machine made) 5 to 10mm dia and length of bolt exceeding 5cm but n exc 10 cm long with hexagonal or square head at one end and other end screwed or both end screwed, each screwed end to be fitted with washers and one haxagonal or square nut complete all as specified and directed.
S & F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with complete fixing acessaries complete alll as specified and directed.
M & L for Plain Cement Concrete(1:3:6), type C-2, (using 40 mm graded stone agg) as in foundations, filling and mass concrete complete all as specified and directed.
M & L for prepration of new steel surface of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tin and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and directed.
M & L for prepration of new steel surfaces of any description and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and directed.
M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering , doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing only complete all as specified and directed.
Supplying and installing of 1.2mm thick SmartCare pre-applied HDPE membrane granulated having puncture resistance of 800N as per ASTM E 154), tensile strength of 21 Mpa, and hydrostatic head resistance not less than 70m water head as per ASTM D 5385 & elongation of 500% as per ASTM D 412, peel adhesion to concrete of 1200 N/m as per ASTM D 903, Lap peel adhesion > 450N/m as per ASTM D1876. The pre-applied, fully bonded HDPE sheet membrane shall be loosely laid on PCC and gets bonded to the underneath of the poured concrete of base/ raft slab and confined retaining wall. The fully bonded HDPE sheet membrane shall consist of a high performance PE film, self adhesive polymer layer and unique particulate layer with pressure sensitive adhesive, which bonds fully to the poured concrete of base slab/confined retaining wall. The membrane shall have minimum of 75mm side laps and end laps which shall be sealed with double sided adhehive tape.,etc complete as per manufactures specification and instructions complete all as specified and directed.Make-Asian paints/Fosroc/Pidilite/equivalent. Note:-The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work.
Disconnecting and Taking up or down existing unserviceable steel water tubing (GI Pipe) and connections and S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- Note :- 80mm and 100mm bore pipe will be jointed by welding as directed at site
GI pipe 150mm dia bore
GI pipe 100mm dia bore
GI pipe 80mm dia bore
Disconnecting and taking down the existing unserviceable sluice valves of size 150mm dia installed in positon and removed from site and Supply, Fixing, Testing & connecting cast irom sluice valve heavy duty double flanged, 150mm dia PN 1.6 conforming to IS 14846 : 2000 ISI marked with Stainless steel spindle and two Nos of MS flange of 16mm thick, 8 holes with nuts and bolts packing materials complete including cutting the existing watermain for fixing cast iron sluice valve and jointing, welding complete as required at site of water supply installations complete all as specified and directed.
All as per item No 42 here-in-before but 100 mm dia bore
All as per item No 42 here-in-before but 80 mm dia bore
M&L for valve chamber of size 900mm x 900mm x 860mm (internal dimentions) with brick masonty valve chamber, 100mm thich PCC (1:4:8) type D2 as in foundation, 230mm thick brick wall built in CM (1:6), 50mm thich coping of PCC (1:3:6) type C1, 15mm thick plastering in CM (1:4) to all internal and exposed surface including necessary excavation and earth work in soft/loose soil, MS sheet cover 6mm thickness along with angle iron frame of size 40 x 40 x 5mm with locking arrangement with necessary fixing materials like hinges, nut bolts etc (valve chamber cover shall be opened in two valves) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc with complete all as specified and directed.
chaprana enterprises
PIONEER REFRIGERATION AND ELECTRICALS
Panwar Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .