Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.0 L+₹22,816 (13.0%)Rejected-Finance | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | POZITIVE POWER INDIA PVT LTD L1 | SUNIL P P L2 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | OD217641/2025-2026:Supply installation testing and commissioning of 11kV outdoor oil cooled CTPT unit suitable size 3 Nos Current transformer Rating 5/5A, Accuracy class 0.2S, burden 10VA IL 12/28/75 kV as per IS 2705 and PTs (, Rating 11kv/110 volt, Accuracy class 0.2, 20VA, IL 12/28/75 kV as per IS 2705(or suggested by KSEB) including giving necessary connections as per the direction of Engineer In charge. | 1 | each | 1,03,000 ₹1,03,000 Lowest | 1,48,300 ₹1,48,300 |
| 1.00 | OD217643/2025-2026:Conveying the CT&PT to nearby TMR Division for testing and taking back to site including loading and unloading charges necessary fees etc as required | 1 | each set | 27,900 ₹27,900 | 7,800 ₹7,800 Lowest |
| 1.00 | OD217649/2025-2026:Charges for dismantling the existing CTs and PT | 1 | each | 4,900 ₹4,900 | 2,070 ₹2,070 Lowest |
| 1.00 | OD218223/2025-2026:Supply & drawing of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing PVC/DWC pipe as required for connecting CT PT terminals to test terminal bo.12 core 2.5 sq mm | 10 | metre | 720 ₹7,200 Lowest | 923 ₹9,230 |
| 1.00 | 90.12.24.1:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm | 24 | each | 15 ₹360 Lowest | 22 ₹528 |
| 1.01 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm | 24 | each | 20 ₹480 Lowest | 26 ₹624 |
| 1.01 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm | 5 | metre | 300 ₹1,500 | 295 ₹1,475 Lowest |
| 1.01 | 1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm | 5 | metre | 225 ₹1,125 Lowest | 231 ₹1,155 |
| 1.01 | OD218437/2025-2026:Supply and providing PVC alphabetic /numerical fire proof ferrule (Up to 6 mm) for identifying the wires etc.as required. | 50 | each | 10 ₹500 | 8 ₹400 Lowest |
Tender Value
₹1.8 L
EMD Value
₹4,425
Closing Date
13 Mar 2026, 6:00 pmClosed
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
DEPOSIT-Govt. Residential Womens polytechnic College Payyanur- Replacing CT- PT unit for Upgradation of ToD to Smart meter-Urgent Replacement of CT PT Unit of 250kVA Outdoor Transformer at RWPTC Payyannu
2026_PWD_834648_3
PWD/BLDG/TR/21580/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹4,425
13 Aug 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
13 Mar 2026
6 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | OD217641/2025-2026:Supply installation testing and commissioning of 11kV outdoor oil cooled CTPT unit suitable size 3 Nos Current transformer Rating 5/5A, Accuracy class 0.2S, burden 10VA IL 12/28/75 kV as per IS 2705 and PTs (, Rating 11kv/110 volt, Accuracy class 0.2, 20VA, IL 12/28/75 kV as per IS 2705(or suggested by KSEB) including giving necessary connections as per the direction of Engineer In charge. | - | each | - | - |
| 1.002 | OD217643/2025-2026:Conveying the CT&PT to nearby TMR Division for testing and taking back to site including loading and unloading charges necessary fees etc as required | - | each set | - | - |
| 1.003 | OD217649/2025-2026:Charges for dismantling the existing CTs and PT | - | each | - | - |
| 1.004 | OD218223/2025-2026:Supply & drawing of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing PVC/DWC pipe as required for connecting CT PT terminals to test terminal bo.12 core 2.5 sq mm | - | metre | - | - |
| 1.005 | 90.12.24.1:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm | - | each | - | - |
| 1.006 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm | - | each | - | - |
| 1.007 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm | - | metre | - | - |
| 1.008 | 1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm | - | metre | - | - |
| 1.009 | OD218437/2025-2026:Supply and providing PVC alphabetic /numerical fire proof ferrule (Up to 6 mm) for identifying the wires etc.as required. | - | each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1425514.xls
BOQ • 0.30 MB
MOM.pdf
Tender Documents • 0.19 MB
viewsbd.pdf
Tender Documents • 1.63 MB
viewnit.pdf
Tender Documents • 0.02 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .