Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.8 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹1.1 Cr+₹16.0 L (17.8%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | - | Rejected-Technical Documents found not having eligible category c(ii) |
| Sl No | Description | Qty | Unit | SHAIJAL T M L2 | M/S ADHIKARI CONSTRUCTION CO. L1 |
|---|---|---|---|---|---|
| 1.00 | LIFT AND CIVIL WORK:
Design, supply, installation, testing and commissioning of electrically operated Machine room less (MRL) Passengers lift of capacity 408 kg (06 Passenger) with a speed of 1.25 mtr/ sec to serve ground floor and 04 upper floors (G+4), with microprocessor based operation and with simplex collective, selective, control with or without lift attendant and with variable voltage, variable frequency system with two speed automatic control drive, with elevator sliding car door and landing door made of stainless steel, car cage made out of not less than 1.2 mm thick stainless steel (SS 316), vandal proof (Scratch free, Hairline finish) as well as cage roof covered with stainless steel sheets of suitable size cage floor made of granite floor minimum 10mm thick of approved colour, automatic car levelling micro stroke push button operation and floor indicators in car in all landings, fire man switch, emergency lamp, alarm push button etc with and including automatic rescue device (ARD) battery operated with and including maintenance free battery of suitable capacity and battery charger with optimum direction section in start operation requiring no human intervention, 3D infra red sensor in full length of doors and built in floor announcing system with 03Nos handset one each in car, Top floor near control panel and ground floor and over load indicator with suitable for three phase, 415 volts, 50 Hz AC supply for passenger lift and LT panel incl all accessories such as MCCB/Isolator/MCB and connected items with the recommendation of OEM and EIC including construction of lift building in permanent specification as per E-in-C specifications (excluding pile foundation and pile cap) & including connecting passage with steel structure & SS hand rail, poly carbonate sheet wall & roof (including foundation) and consultancy for structural design & estimate as per architectural drawing all as specified and directed. | 1 | Job | 56,22,400 ₹56,22,400 Lowest | 59,99,999 ₹59,99,999 |
| 1.10Description for lift:- (a) Quantity : 01 (One) unit (b) Assembled Product : Passenger Elevator (c) Capacity : 408 Kg (d) Speed : 1.00 m/s (e) Stops & Openings : 5 Stops, 5 Openings (f) Floor designations : G,1,2,3,4 (g) Machine type & location : Gearless machine located in the overhead of lift well (h) Control : Simplex collective selective control (j) Drive : ACVVVF (k) Power Supply : 3 Phase, 415V, 50 HZ (l) Hoist Way Dimensions : 1800mm wide x 1600mm deep (m) Car Travel : As per site requirement (n) Overhead : 4200mm (o) Pit depth : 1600mm (p) Car Dimensions : 1000mm wide x 1100 mm deep x 2200 mm high (q) Door Opening :2100 mm high centre opening/stainless steel Hairline finish (SS 316) (r) Car Design : Stainless steel Hairline finish (SS 316) (s) Car Flooring : Granite flooring 10mm (t) Handrail : Round handrail in stainless steel finish provided on rear wall of car (u) Landing operating panel : Individual landing operating panel for each floor in each elevator (v) Displays : LCD Displays in cabin operating panel and in all landings (w) Special Features : Automatic Rescue Devices with visual and audio indicator/3 way intercom/provision for camera cable (x) Special Features : laminated mirror of entire width of rear panel of half height | |||||
| 1.20Note for lift: 1 The load, design and GAD of the elevator and structure shall be submitted by the contractor duly recommended and vetted by the OEM and vetted by authorised structural engineer before commencement of work. 2. Any special items/accessories left out in the contract for successful completion of the work shall be provided by the contractor as per site requirement and the cost for the same deemed to be included in the unit cost. The tenderer and OEM should visit the site to check the feasibility and soil conditions/ alteration civil wks required at site before bidding the tender. 3. The necessary major components as per latest IS/BIS/OEM standards and sample approval of major components shall be taken by the contractor before starting the work. 4. Re-routing of unit power cables and pipelines..etc to be included in the quoted rate. 5. The lift pit shall be constructed in RCC with water proofing as recommended by the OEM of lift. 6. 01 Nos LED bulkhead fitting with surface mounted switch socket drawn through PVC conduit of 2.5 sqmm cable with MCB switch of 10 Amps. 7. The lift OEM should have a service center located in Kochi to attend complaints as and when required. | |||||
| 1.30Civil work for lift building Construction of RCC framed structure lift building in permanent specification all as per E-in-'C's specification excluding pile foundation & pile cap all as per architectual & structural approved drg. | |||||
| 1.40Civil work for connecting passage Construction of connecting passage with steel structure and SS hand rail & 6mm poly carbonate sheet for roof and vertical faces all as specified and as per architectual & structural approved drawing. Note for lift building & connecting passage : Architectural drawing provided with this is tentative. Any variation in size of room and structural members shall be finalised as per structural drg and as per manufacture's requirement for lift room and connecting passage. The rate quoted shall be inclusive of the same. | |||||
| 1.50Consultancy for structrural design & estimate of lift building in G+4 configuration near ATC building in permanent specifications (Appx area 43.20 Sqm) and steel structural for connecting passage from 1st floor to 4th floor (Appx area 24 Sqm) along with closed varandah at ground floor with foundation all as per architectural drgs and soil report provided, including vetting of structural drawings from NIT/ IIT/ Govt Engineering collage and submisson of final drawings with input data file, structural drgs in autocad (one original set in tracing along with 3 sets in A2 size incl. Foundation plan, floor level plan and roof plan. Note:- (a) The design of building & steel structure from first floor to fourth floor shall be considering all parameters as per relevant IS like, IS 456 .2000 (latest version), IS 800 : 2007, IS 11384 : 1985, IS 875, IS 1893, IS 4326, IS 13920 etc. Importance factor 1.0 shall be as per relevant IS with severe exposure condition,the drg has to be got approved from HQ CWE(NW) Kochi before vetting by NIT/NIIT/ Govt Engineering college. (b) Suitable design for connecting passage resting on existing building shall be part of design included in cost quoted. (c) Yard stick for building works shall be provided by contractor to take approval from accepting officer. | |||||
| 2.00 | Materials and labour for connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed.
Note; This item shall be measured for the quantity used at site after the length of strip 7.5 Mtr. | 50 | RM | 520 ₹26,000 | 199 ₹9,950 Lowest |
| 3.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core. | 100 | RM | 700 ₹70,000 | 299 ₹29,900 Lowest |
| 4.00 | PILE FOUNDATION
Excavation over area ,n. exc. 1.5m in deep and getting out in soft/loose soil complete all as specified and as directed. | 14 | Cum | 300 ₹4,200 Lowest | 499 ₹6,986 |
| 5.00 | Excavation over area exc. 1.5m in depth and upto 3m in depth and getting out in soft/loose soil complete all as specified and as directed. | 5 | Cum | 400 ₹2,000 Lowest | 699 ₹3,495 |
Tender Value
₹9.7 Cr
EMD Value
₹1.7 L
Closing Date
8 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri RK Singh IDSE CWE(NW) Kochi
CWE(NW) Kochi
PROVISION FOR DEFICIENT LIFT FOR ATC BUILDING NO P-4 INCLUDING 03 YEARS COMPREHENSIVE MAINTENANCE AT INS GARUDA NAVAL BASE KOCHI
2025_MES_724048_1
CWE(NW)KOCHI/81567
Open Tender
Civil Works
Item Rate
270 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹1,000
GE(NS) Kochi
₹1.7 L
Yes
17 Oct 2025
1 Aug 2025
11 Sept 2025
1 Aug 2025
8 Sept 2025
25 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
177291418.xls
BOQ Document • 0.36 MB
177291419.pdf
Tender Document • 0.62 MB
Tenderdocument.pdf
Tender Document • 2.17 MB
177291421.html
Tender Document • 0.06 MB
179135174.pdf
Tender Document • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .