Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC 2ND FLOOR SC ROAD SANTA PLAZA TEZPUR DISTT SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.4 L+₹1.9 L (4.59%)Rejected-Finance | L2 | Rejected-Finance Becomes L2 | |
| 3 | L3₹43.9 L+₹3.4 L (8.47%)Rejected-Finance GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | L3 | Rejected-Finance Becomes L3 |
Tender Value
₹42.4 L
EMD Value
₹84,800
Closing Date
30 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Tezpur
GE South Tezpur, Mission Charlia
PROVISION OF CERTAIN SANCTION WORKS (PHASE-II) UNDER GE (SOUTH) TEZPUR
2023_MES_611617_1
8765
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹84,800
Yes
9 Sept 2023
1 Aug 2023
1 Sept 2023
1 Aug 2023
30 Aug 2023
16 Aug 2023
2 Aug 2023 - 15 Aug 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in loose/soft soil.Complete all as specified and as directed
Returning , filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick.
Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point Complete all as specified and as directed
M & L for PCC 1:4:8 type D2 using 40 mm graded aggregate as in foundation filling and mass concrete.Complete all as specified and as directed
Demolition of brick work/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and pre-cast concrete articles all as directed.
M&L Brickwork with subclass ‘B’ bricks burnt brick old size, straight or curved on plan exc 6m mean radius built in Cement morter 1:6. Complete all as specified and as directed
Supply and fix, steel windows with side hung shutter including box type hinges with steel handle and steel peg stay, complete with glazing bars, donetailed or welded.Complete all as specified and as directed
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded.Complete all as specified and as directed
S&F for Steel ventilators with top hung shutter including hinges, steel peg stay.Complete all as specified and as directed
Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors, ladder, framed balusters, railing, frame work for water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165.Complete all as specified and as directed
S&F for 01mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angle, etc as in required. Complete all as specified and as directed
S&F 100 mm butt hinges, heavy weight, cold rolled mild steel, and fixed.Complete all as specified and as directed
S&F 150 mm size, Cast iron or malleable cast iron handles, cast type, stove enamelled black.Complete all as specified and as directed
S&F for 150mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed.Complete all as specified and as directed
S&F for 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and directed by Engr-in-Charge.
S&F 3 mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane.Complete all as specified and as directed
S&F Sheet glass 5.5mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.Complete all as specified and as directed
M&L RCC M-25 Design Mix (20 mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.Complete all as specified and as directed
M&L RCC M-25 Design Mix (20 mm graded aggregate) in Columns, pillars, piers, posts and struts.Complete all as specified and as directed
M&L RCC M-25 Design Mix (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span and the like.Complete all as specified and as directed
M&L RCC M-25 Design Mix (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.Complete all as specified and as directed
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.Complete all as specified and as directed
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions.Complete all as specified and as directed
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping).Complete all as specified and as directed
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.Complete all as specified and as directed
M&L TMT bars 10 mm dia and over , cut to length, bent to shape required, including crancking, bending spirally for hooping for columns ,hooking ends & binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & as directed.
M&L TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.Complete all as specified and as directed
M&L TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.Complete all as specified and as directed
M&L rendering 15 mm thick cement plaster (10+5) in two layers of 10mm flows to 5 mm on brick wall or concert surface in CM 1:4 mixed with WPC @ 2% by weight of cement or as per manufacture instruction and finished even and smooth without using extra cement including chicken wire mess of size 10mm x 10mm at portion where brick wall & RCC surface jointed minimum 300mm wide complete all as specified and as directed. (Note : WPC will be measured and paid for separately)
M&L 10mm thick rendering in cm (1:6) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement including 10mm grouting and hunching at vertical and horizontal flash joint at RCC structural and brick work complete all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished even and smooth surface without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash as in ceiling complete all as specified and directed.
M&L Applying two coats of acrylic emulsion distemper by smart painting method to newly plastered/previously untreated wall over a coat of 1 mm layer wall care putty thick layer over a coat of primer including preparation of newly platsered wall all as specefied and directed.
M&L Applying two coats of acrylic emulsion distemper by smart painting method to wall over a coat of 1 mm thick layer wall care putty over a coat of primer including complete removal of existing treatment all as specefied and directed.
M&L preparation of new plaster surface or complete removal of old plaseter sufaces and appplying two coats of weather coat(Apex) over one coat of damp proof primer by smart painting method to wall/chajja of external surface as per manufacturer instruction and apllied by approved applicator.complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick1:6 screed bad laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement mortar 10 mm thick 1:4 screed bed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for 75mm thick pcc type C-2, 1:3:6 (using 40 mm graded aggregrate) as in sub base, flooring, plinth protection Finishing cement concrete surface even and smooth Without using extra cement.complete all as specified and directed.
M&L hardcore of broken stone or boulders gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick, watered & rammed to a true surface complete all as specified & as directed.
M&L Sand filling under floors or in foundations including watering and consolidation.complete all as specified and directed.
Damp proof course 40mm thick In cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork with using polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specified and directed.
M & L for PCC 1:3:6 type C1 using 20 mm graded aggregate as in copping, holdfast and the like including weathering, slightly rounded or chamfered angles and throating.complete all as specified & as directed.
M & L 15 mm thick in cement mortar (1:4) on existing roof surface true to level with WPC using as per manufacturer instruction of cement after applying cement slurry and applied coat of hot blown bitumen of graded 85/25 @1.2 Kg/Sqm.complete all as specified & as directed.
Supply and laying 3mm thick APP based Polymeric membrane of approved manufacture with weight not less than 3.60 Kg per Sqm reinforced with non-woven polyester fabric weight not less than 150gms per Sqm. After preparation of roof surface on apply bitumen primer @ 0.4ltr/sqm shall be applied. The overlap shall be not less than 100mm on transverse direction and 75mm on longitudinal direction and sealing overlaps and applying evenly one coat of aluminum paint @ 0.10 liter per square metre over the APP based polymeric membrane complete all as specified and as directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured).complete all as specified & as directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area.complete all as specified & as directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area.complete all as specified & as directed.
Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering.complete all as specified & as directed.
S&F 0.5mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour ,tensile strength of 550Mpa as in roof covering ,cladding to wall ,ridge,gutter etc fixed with self tapping screws.complete all as specified & as directed.
All as per item No.53 above but plain sheet for ridge ,gutter etc fixed with self tapping screws as specified.
Dismantling Structural steel work includings door, gates, etc and similar works complete all as directed
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.
M&L preparation of old painted steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint.complete all as specified & as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for Nitobond chemical applying for old concrete surface to bonding with new concrete complete all as specified and as directed.
M & L For Nitozinc chemical applying to old rusted reinforcement complete all as specified and as directed.
Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and directed.Make:-LG/Samsung/Hitachi/Voltas/Blue star/Haier/Carrier/Godrej NOTE : (i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology. (ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates. (iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.
Supply and install hi wall Inverter 5 Star split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 Ton all as directed. Make:- LG Cat No.RS-Q19ENZE.ANLG or equivelant make of Samsung/Hitachi/Voltas/Blue star/Haier/Carrier/Godrej
Supply, installation, testing and commissioning of Wall mounted split type Air conditioner electric driven 240 volt grade,50 Hzs single phase 5 star rated with ISEER > 4.6, with variable speed compressor, energy saving 2 Ton capacity cordless remote controll unit with built air ioniser and invertor tecnology for better indor air quality complete with all fixing factory made steel stand set for mounting to out door unit nut ,bolt , washer etc and insulating materiels ,making all electric connection as specified and directed by Engr-in-charge. Note: Quoted rate shall be included the rate of copper tube upto required length and factory made out door unit mounting bracket with fixing nut, bolt and other at site. Make:-LG/Samsung/Hitachi/Voltas/Blue star/Haier/Carrier/Godrej
All as per item No 60 but capacity of 1.5 Ton , 5 star with ISEER > 3.2, with variable speed compressor Complete all as specified and directed. Make:-LG/Samsung/Hitachi/Voltas/Blue star/Haier/Carrier/Godrej
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade suitable dia 25mm complete with fittings all as specified and as directed.Make: RR/Polycab/Havells/KEI
M&L for sub main wiring with two run of 2.5 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC casing caping and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.Make:- RR/Polycab/Havells/KEI
Supplied & fixed Single pole and neutral enclousure with a two pin and earth plug and socket complete with double pole MCB 20 Amps.Make : Havells/Legrand/ABB/C&S
Supply and fixing MCB 240 Volts C Curve SPN 6-32 Amps 10 KA.Complete all as specified and directed
Supply, install, testing & commissioning of copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 130 V to 300 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 4.0 KVA incl electric connection complete all as specified and directed.Make-Microtek/Aplab/AE/Voltamp/V-Guard/Servo
Supply and fixing and connecting of fully automatic single phase naturally air cooled indoor type wall mounting type digital voltage stabilizer voltage variation between 130 to 300 volts with output voltage stabilizer at 230 v with accuracy of +/- 2.5% of capacity 5KVA (suitable up to 2 Ton or 24000 Btu/Hr) W TDR all as specified and directed Make : V-Guard model VD 500 in equivelent make of Microtek/Aplab/AE/Voltamp/Servo.
M&L for point wiring with multistranded copper conductor cable, PVC insulated and unsheathed size 4 sqmm drawn in and incl PVC casing caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for 3/5 pins socket outlet 15 Amps independent/plug socket with pressed steel concealed terminal boxes covered with 3 mm thick laminated sheet incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 4 Sqmm for earth wire connected to common earth dolly all as specified and directed Make : Polycab/ Havells/ Finolex
Supply and fix water cooler electric driven (single phase), full stainless steel having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and as directed. Make:- Blue star, Voltas, Whirlpool Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
Chinmay Traders
M/S MOHANPASARI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .