Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.4 L+₹3.0 L (9.71%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹33.5 L+₹3.0 L (9.95%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.6 L+₹3.1 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
21 Jan 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIR TO MT POOL, POL STORE, CAFETERIA, RAMP / WASHING AND TOILET AT NAE UNDER GE NAVY PORBANDAR
2021_MES_497354_1
9108/PBR/E8
Open Tender
Civil Works
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹60,000
Yes
16 Mar 2022
24 Dec 2021
24 Jan 2022
24 Dec 2021
21 Jan 2022
8 Jan 2022
25 Dec 2021 - 7 Jan 2022
Amount
Taking down old roof treatment of any description including plaster, cement concrete etc. and removing old material outside MD land exc 1Km and not exceeding 5 Km completely all as specified and directed by Engineer - in - Charge.
10 mm thick (average) bedding layer on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, mixed with WPC, finishing even and smooth without using extra cement complete all as specified and as directed. Note: WPC measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed.
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane cover including testing on completion complete all as specified and directed.
Bird proofing net of 100% virgin nylon mono filament net made of around +/- 0.80 yarn in 32mm square mesh and having yarn breaking strength appx. 23 Kgs per yarn having ultra violet stabilized for hangar fixed in repair / replacement complete all as specified and directed.
Taking down cement plaster on brick, stone or concrete surface including racking out joints hacking for key scrubbing down with water to receive plaster etc complete as specified and directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 5 mm thick in cm 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of chalk whitning preparatery to distempering as in wall complete all specified and directed.
Preparation of newly plastered surfaces and applying three coats of white wash preparatery to distempering as in ceiling complete all specified and directed.
Preparation of newly plastered surfaces of walls, soffits & facias of beam, chajjas etc applying two coats of weather proof Acrylic based exterior emulsion paint over a coat of primer complete all as specified and directed.
Preparation of old distempered surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper complete all specified and directed.
Preparation of old plastered surfaces of walls, soffits & facias of beam, chajjas etc applying two coats of weather proof Acrylic based exterior emulsion paint over a coat of primer complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of ceilings and applying two coats of white wash complete all as specified and directed.
Demolition of brick work or stone/ boulders masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlars facing, dressed stone work and precast concrete articles complete as specified and directed.
Demolition of unreinforeced cement concrete of any description and in any position not otherwise specifically provided for complete as specified and directed.
Stone masonry walling or squared walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Dismantling of stone slabs and tiles laid bedded and pointed in any mortar thickness in floors, aprons and wall claddings complete all as specified and directed.
20mm thick Granite of Ist quality, table rubbed and polished, in floor set in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 12 mm thick bedding layer in cement mortar 1:3, including grinding and polishing, complete all as specified and as directed.
75 mm thick PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (coloured) any shape and size conforming to IS 15658-2006 of 60mm thick M-35 grade (with grey cement and pigment) with 30 mm thick compacted sand coushioning complete all as specified and directed.
Kitchen sink with drainage board made of stainless steel 1mm thick (SS grade 304AISI 18/8) IS embossed (IS:13983) glossy finish with plugs, washers and wastes; including bedding in cement mortar to platform or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, fixed in repairs, complete all as specified.
PVC (SWR) pipes, 110mm bore, single socketed, 4.00 Kgf per Sqcm pressure, in any length with rubber ring joints fixed in repair / replacement complete all as specified and as directed.
Bib taps chromium plated, fancy type with crutch or butterfly handle, screwed down for iron pipe, 15 mm bore of pipe fixed in repairs complete all as specified and directed.
Demolition/breaking up drain pipes (salt glazed stone ware) any size jointed in cement mortar of any description including PCC bed complete all as specified and directed by Engr-in-Charge.
RCC Hume pipe NP-3, 300mm dia laid and jointed complete with collars in cement mortar 1:1 in trenches complete all as specified and as directed by Engineer-in-Charge.
Mild steel CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Pre-cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab of drain, manholes, septic tanks, etc. and set in cement mortar 1:6 including dismantling of damaged RCC covers slab complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Item(s).
Forming 20mm thick expansion joints filled with preformed bituminous filler and top 30 primed and sealed with sealing compound grade 'A' thickness of concrete slab to be 200mm complete all as specified and as directed.
Forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, Grade 'B' complete all as specified and as directed.
Cement concrete work in pavement/ hardstanding of flexural strength 40 kg per sq cm in field using 400 kg of cement per cubic meter , thickness of concrete 150mm complete all as specified and as directed.
Anodised aluminium snap gridframe work for false ceiling at any height of size with 600mm x 600mmgrid and Snap grid frame work shall be fixed to ceiling with supporting hanger consisting of 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all asmanufacturer’s instructionThe main and cross tees jointed at junction/crossings with anodizedaluminium angle bracket of size 15mm x 15mm x 1.5mm, weighing 0.12 Kg per running metre,Main/cross tee section shall be supported at ends all along the wallwith anodized aluminium angle of size 40mmx25mmx2mm, weighing 0.36 Kg per running metre, including providing and fixing 25mm thick particle boards on ceiling fixed to the ceiling section with 25mm long self drilling and tapping screws having Phillips head with under head cutter at minimum spacing of 200mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seamless finish and multi layer design, complete all as specified and as directed.
Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) 5000 Litre capacity, hoisted and fixed in position, with lid, tounge nipple for inlet, outlet connections complete all as directed by Engr-in-Charge.
Low density polyethylene (LDPE) 32 mm dia pipes of pressure rating 6 kgf/sq. cm complete to walls, ceilings or in floors fixed in repair / replacement complete all as directed by Engr-in-charge.
Dismantling of water tank RCC / HDPE of size exc 1000 ltrs n.exc 2000 ltrs capacity complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Factory made 35mm thick, 2nd class hard wood, plain framed, panelled shutters, (two panel) with lock rail and, panels shall be of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed.
Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
Factory made solid panel PVC moduled door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification & drawing complete all as specified and directed.
Preparation of new or previously untreated wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wooden primer complete all specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 300mm long with fixing clips of sheet, cast or extruded sections fixing bolts and sliding bolts of extruded section or cast-aluminium alloy complete all as specified and directed.
200mm long mild steel barrel tower bolts of extruded section complete all as specified and directed.
150mm extruded aluminium alloy handles, cast type, anodised complete all as specified and directed.
100mm Butt hinges medium weight, cold rolled, stainless steel, and fixed complete all as specified and directed.
Screed bed or beeding layer or mortar (CM 1:6) 15mm layer of mortar for laying roof floor finishes complete all as specified and directed.
Vitrified coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 20 mm thick in cement mortar 1:6 Complete all as specified and directed.
Non skid Ceramic coloured Joint free tiles of size 400 x 400 x 8mm thick (area of each tile exceeding 0.11 Sqm but n.exc. 0.18 Sqm) as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 10mm thick rendering in cement mortar (1:4) complete all as specified.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed surface complete all as specified and directed by Engineer - in - Charge.
Dismantling wrought iron or mild steel work of any description not otherwise described for any description including railingf , guard bars, grill or stainless steel railing, complete all as specified and as directed.
Dismantling of old galvalume sheet plain or corrugated on roof/cladding of hangar including 'J' bolt complete all as specified and directed by Engr-in-Charge.
High tensile galvalume sheets colour coated single skin high rib / multi rib TMP Profile Galvalume sheeting in roof having 1000-1020 mm width 28 mm high crest @ maximum 250 mm pitch (centre to centre) and minimum 190mm manufactured out of 0.50 mm TCT (total coated thickness) cold rolled steel, having yield strength 550MPa minimum and wall coated with 25 micron modified polyester paint system applied on Zincalume on top and with back coating on sheet shall be 7-10 micron epoxy paint. The sheet shall be supplied in length maximum upto 6-12 meters long to suit with structural dimensions and fixed with self tapping screws with built in gasket (with bitumen washer) of suitable size machine fixed as per manufacturer instructions and applying adhesive compound to joint overlap of sheets complete all as specified and directed by Engineer-in-Charge.
Rolled section as in framing for claddings, purlins and rafter cutting laps to shape as required drilling holes, notching for wire including all necessary drilling, rivetting or bolting or welding complete all as specified and as directed.
Preparation of new steel surface of any description, over 10cm in width or girth, not otherwise described and applying two coats of Synthetic Enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light/fan, buzzer, socket or power point etc) complete including all fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Taking down sub main wiring and making good disturbed surfaces of wall / floor complete all as specified and as directed.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:-
(a) One light point/bell point controlled by one switch
(b) One ceiling fan /Exhaust fan controlled by one switch & regulator
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for description a for independent switch socket outlet 3 pin 5 Amps and all as directed at site.
All as per above item No.64.00 but below/parallel the switch board of independent 5 Amps socket in the same vertical/horizontal plane.
Modular switch 1 way 6 Amps, 1 modules 230 volts complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Taking down existing ceiling fan / exhaust fan any size, any make, refixing the same after replacing the rubber bushes, split pin, servicing, greasing and painting with two coats of synthetic enamel paint etc complete all as specified and directed.
Exhaust fan 300mm sweep AC, 240 volts connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable fixed in repair / replacement complete all as specified & directed by Engr in charge. Make :Bajaj Maxima Dx 300mm OR equivalent model of make specified in appx 'B' hereinbefore.
Supply and fixing 4 Feet 20 Watt LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod , complete all as specified and directed by Engr-in-Charge. Make : Havells or equivalent model of make in Philips/CG.
Supply and fixing 10 W LED batten (600mm) fitting surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod , complete all as specified and directed by Engr-in-Charge. Make : Havells or equivalent model of make in PHILIPS/CG.
Supply and fixing Street light 70 W elegantly designed highly efficient high power LED street light with pressure die cast aluminium housing, with individual LEDs with modular secondary optics IP66 protection complete all as specified and directed. Make : Havells or equivalent model of make in Philips / CG.
Supply and fixing flood light 70W luminaire grey powder coated dire-cast aluminium housing, built in control gear faceted anodised aluminium reflector heat resistant toughened clear glass cover fixed in repair / replacement complete all as specified and directed. Make : Havells or equivalent model of make in Philips / CG.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid steel concealed conduit of 20mm dia or higher, medium grade complete with and including all conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick recessed hylam sheet top cover, brass screws, cup washers with flame proof cable entry glands etc including all cutting / chases etc in walls complete all as specified and directed for description a for independent switch socket outlet 6 pin 5/15 Amps complete all as specified and directed by Engr-in-charge. (a) One exhaust fan control by one switch
Flame proof exhaust fan of Heavy duty metalic body 240 Volts,50 Hz,1440 rpm,300 mm sweep along with louver including all electrical connectons for proper ventilation at AVGAS & DISEL STORE room complete all as specified and directed by Engr-in-charge. Make :- Prateek or eq model of make specified in Appx 'B' hereinbefore.
Cutting of porbandar stone for fixing of flame proof exhuast fan of size 300 mm dia & making good damaged area by rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
Flame proof and weather proof rotary type switch,16 Amps,230 Volts, AC single pole, (LM-6) aluminium alloy with flame proof cable entry glands CMRS certified,ISI marked rotary type switch, complete all as specified and directed.
Chemical earthing with copper plate electrode 90cm x 60cm x 5 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to copper strip 50x6 mm by means of copper nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 50 mm dia GI pipe light grade for protection of earth lead with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 4 of MES sch Part I complete all as specified and directed. Note :- (a) 7.5 RM copper earth strip including 50 mm dia GI pipe light grade is deemed to be included in quoted rates, beyond 7.5 RM strip shall be measured and paid separately.(b) Earth resistance of earth pit should be less than 0.5 ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost.(c) Rate quoted by the tendered is deemd to include salt and charcoal upto and above 450 mm top of copper plate and putting in MGSO4 100 kg additional in above material.
Earthing continuity copper strip 20 x 3 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
Sub main wiring concealed with 10 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including 10 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
20 mm rigid non-metallic PVC concealed conduit medium grade including all PVC conduit accessories, cutting / chases and making good disturbed surfaces complete all as specified and directed.
Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with one number 5 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge. Make: Sintex Cat No :- GSJB -2817 or equivalent model of make specified in appx 'B' hereinbefore.
Cable PVC insulated PVC bedded flexible electric power cable with stranded copper conductor cross sectional area 1.5sqmm 2core suitable for working on 1100 Volts from junction box to street light complete all as specified and as directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 32 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Supply,fixing,testing & commissioning of vehicle washing reciprocating pump along with following specifications .(i) No of plungers-03 Nos (ii) working pressure 32 kg/cm2 (iii) No of gun-02 Nos (iv) Motor power -03 HP (v) Speed (rpm)-400 (vi) Displacement-22 lpm including all connected accessories complete all as specified and directed by Engr-in-charge of make as approved by GE in writing.
Supply, install, commisioning and testing of LP air compressor with two stage heavy duty ,two cylinder of capacity 5 HP,three phase 415 volts,50 Hz motor with max working pressure 175 Psi all as specified and directed by Engineer-in-charge with following undermentioned technical specifications. (i) Model - KC-742 (5 HP) (ii) Type of compressor - Two stage Heavy duty (iii) No of cylinders-Two cylinders (iv) Piston displacement (CFM) -17.3 CFM (v) Max working pressure -175 Psi (vi) Motor -5 HP,1440 RPM,3 Phase (vii) Starter-Dual starter (viii) Air receiver capacity -200 Ltrs (ix) Tank size 18"x48"
Earthing continuity galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
Vijay Construction Co
M/S Rajendra Constructions
RUDRAAY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .