Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹123.9 CrAccepted-AOC | ₹123.9 Cr | L1 | Accepted-AOC L-1 Bidder |
| 2 | L2₹125.7 CrRejected-AOC | ₹125.7 Cr | L2 | Rejected-AOC L-2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 4 | Rejected-Technical 13TH FLOOR DN18 SALTEE TECH PARK SECTOR V SALT LAKE BIDHAN NAGAR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | - | - | Rejected-Technical Non responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non responsive |
Tender Value
Refer Docs
EMD Value
₹1.2 Cr
Closing Date
3 Apr 2023, 11:00 amClosed
SE CandP2
SE CandP2 PTCUL Dehradun
Construction of 220 132 33KV 2X160MVA 2X40MVA AIS Substation Mangalore Haridwar
2022_PADB1_52205_1
P2/ADB/PTCUL/2022/220/132KVAIS SS
Global Tenders
Electrical Works
730 days
Dehradun
Please refer Tender documents.
9 documents required · 9 mandatory
₹30,000
MD PTCUL
₹1.2 Cr
Dehradun
6 Jun 2024
30 Nov 2022
3 Apr 2023
30 Nov 2022
3 Apr 2023
23 Feb 2023
15 Dec 2022
Supply
Transformers
160 MVA, 220/132/11KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
40 MVA, 132/33KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
Nitrogen Injection Fire Prevention & extinguishing system for transformer with MS Tank.
Oil Storage Tank (15 KL)
Oil sampling Bottle, Stainless Steel 2ltrs capacity.
LT Transformers
630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
245kV Equipments
245kV SF6 Circuit breakers (3 Ph.), 2500A, 40kA
245kV (5 Core) Current Transformer (1 Ph.)
For Line, BC, TBC
For Transformer
Junction box for above CT
245kV Capacitive Voltage Transformer (1 Ph.), 4400pf
Junction box for above CVT
245kV Isolators (3-phase)
1600A, 40 KA, isolator with one E/S
1600A, 40 KA, isolator with two E/S
1600A, 40KA, Isolator without E/S (Tandem)
198kV Surge Arrestors
245 kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay
Transfer Bus Coupler Bay
Bus Coupler Bay
Bus Works (for three Bus)
145kV Equipment
145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA
145kV (5 Core) Current Transformer (1 Ph.) with Junction Box
For line feeder
For 220kV Transformer LV
For 132kV Transformer HV
145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
Isolators
145kV (3-phase) (Horizontal Double break)
1250A, 40kA, Isolator with E/S
1250A, 40kA, Isolator without E/S
1250A, 40kA, Isolator without E/S (Tandem)
120kV Surge Arrestors
145kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay (220kV LV & 132kV HV)
Bus Coupler Bay
Bus Works (for two bus )
33kV Equipments
33kV Isolator (3-Ph)
Without E/S
With E/S
33kV Circuit Breaker
Current Transformer
33kV Current Transformer (single phase) for Transformer with Junction Box
33kV Current Transformer (single phase) for Line with Junction Box
30kV Surge Arrestor
33 kV PT (single phase) with Junction Box
33 kV Bus Post Insulators/Solid core insulator
2*5 MVAR Capacitor bank
33kV Circuit Breaker
33kV Isolator with earth link
33kV Isolator without earth link
Single phase Reactor
33 KV NCT
33 KV Control and relay panel
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
33kV 1 Main+1 Transfer
Line bay
Transformer Bay 33KV
Bus Coupler Bay
Bus Works (for two Bus)
Capacitor bank
Substation Automation
Complete substation automation system including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications
Bay Control Units
I) 220kV system
II) 132kV system
III) 33kV system
AC Kiosks
I) 220kV system
II) 132kV system
III) 33kV system
Online Monitoring, Data Acquisitionand ABT Analysis System
ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only.
DCU & Accessories
Industrial Grade Network Switch -8 Port, unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation: Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition (Latest) / ORACLE (Latest)
MS office - Standard edition (Latest)
MacAfee Virus Scan Enterprise Desktop Edition (Latest) - Per Year
Local Energy Monitoring Software - Professional edition
LAN cable (average one roll per S/S 300 Meters) Cat-06
PVC conduit Pipe - 3/4" ISI Mark
Enclosure for LAN Switch
3G/4G/5G Data enable SIM
Cable 4 Core 2.5 Sq. mm Copper, Armored
SDH/MUX EQUIPMENT
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
220 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1+Main 2)
Bus Bar Protection Panel
220kV ( bus bar protection) 2 Main+1 Transfer
Transformer Protection Panel
132 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel
Transformer protection panel
For 220/132kV LV side
For 132/33kV HV side
Other/common equipments pertaining to C&R system
Time synchronisation equipment (GPS based)
PLCC for 220KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Phase )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
PLCC for 132KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Earth )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
EPAX (24/8) with 24 telephones, cables etc.
33KV control and relay panel
33 KV Tripple Feeder Control and Relay Panel
Testing & Maintenance Equipment
Insulation Tester Meter 15 KV Multirange (Motorized)
Automatic capacitor and Tan Delta measuring kit
Digital Multi meter
Leakage tester (Tong type) 1500 Amps
Signal generator
Micro-ohm meter
Gapless zinc oxide LA tester
Oil BDV Kit 0-100 KV
Gas Evacuating and refilling Plant
Winding Resistance Meter
Thermal Imaging Camera
Gas Leakge Monitor
Circuit Breaker Analyser
Dew Point Meter
Battery Earth Fault Locator
Primary Injection Set 1000 Amp
Relay Test Kit
D-Spanner set (Insulated), Ring-Spanner set (Insulated) & Torque Wrench set. Each set shall be a complete set including all standard sizes.
Insulating Gloves & Helmets
Hydraulic Ladder Battery Operated (Rechargable) upto 300kg capacity & 10 Mtrs height
Spliced ladders 5mtr. & 10mtr.
Spliced ladders 20mtr.
Polyamide or Braided white nylon rope -12 mm, 14 mm & 20 mm of each type
Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements
Shock treatment chart & artificial respiratory system
First-aid box complete with first filling of required medicines, instruments and tools
Danger / Man on line / Break-Down boards of appropriate size
Rain coat, Gum boot and Safety Harness Belt with adequate straps
Air-conditioner
Split AC (Capacity-2T) Max Star rating
Miscellaneous items
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
LT Switchboard
415V Main switchboard
415V AC distribution board
415V MLDB
415V ELDB
220V DCDB
48V DCDB
Batteries
Battery charger system
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
250kVA, 440V DG set alongwith AMF Control panel
Fire Fighting Equipments
50Ltrs Water Mist & CAFS
45 Ltr. Foam Type
20 Kg Co2 Type
4.5kg CO2 type for outdoor kiosk
6 Fire Bucket with stand
Sand Drum (half size) filled with sand
Fire Hut and sand pit
Illumination system
Outdoor Lights LED Type
Indoor Light LED Type for control room and Kiosk
Street Lighting, LED Lights, Solar Type
1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc.
Power Cables Aluminium (XLPE)
3.5cx400 Sq.mm
3.5cx300 Sq.mm
Power cable Aluminium (PVC)
3.5cx70Sq.mm
3.5cx35Sq.mm
4cx16 Sq.mm
4cx6 Sq.mm
Control cable Copper (PVC)
2Cx2.5Sq.mm
4Cx2.5Sq.mm
6Cx2.5Sq.mm
10Cx2.5Sq.mm
Grounding/Earthing system
MS Round 40mm dia
3 mtr deep driven earth electrode 40mm dia
3 meter deep pipe electrode (treated pit)
MS Flat 75 x 12 mm for 220kV Switchyard
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Steel structure
Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
Pipe structure (Auxiliary Equipments Structure)
Mandatory spares as per Annexure-B for the following items:
220 / 132 KV, 160MVA Transformer
132 / 33KV, 40MVA Transformer
245KV Isolator & ES
245KV CVT
145 KV Isolator & ES
145KV CVT
33 KV Isolater &ES
Control and relay panel
Substation Automation
Illumination System
Fire Protection System
DG Set
Battery
Battery Charger
LT switchgear
Erection hardware
Description of Work / Item(s)
Amount
Supply
Transformers
160 MVA, 220/132/11KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
40 MVA, 132/33KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
Nitrogen Injection Fire Prevention & extinguishing system for transformer with MS Tank.
Oil Storage Tank (15 KL)
Oil sampling Bottle, Stainless Steel 2ltrs capacity.
LT Transformers
630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
245kV Equipments
245kV SF6 Circuit breakers (3 Ph.), 2500A, 40kA
245kV (5 Core) Current Transformer (1 Ph.)
For Line, BC, TBC
For Transformer
Junction box for above CT
245kV Capacitive Voltage Transformer (1 Ph.), 4400pf
Junction box for above CVT
245kV Isolators (3-phase)
1600A, 40 KA, isolator with one E/S
1600A, 40 KA, isolator with two E/S
1600A, 40KA, Isolator without E/S (Tandem)
198kV Surge Arrestors
245 kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay
Transfer Bus Coupler Bay
Bus Coupler Bay
Bus Works (for three Bus)
145kV Equipment
145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA
145kV (5 Core) Current Transformer (1 Ph.) with Junction Box
For line feeder
For 220kV Transformer LV
For 132kV Transformer HV
145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
Isolators
145kV (3-phase) (Horizontal Double break)
1250A, 40kA, Isolator with E/S
1250A, 40kA, Isolator without E/S
1250A, 40kA, Isolator without E/S (Tandem)
120kV Surge Arrestors
145kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay (220kV LV & 132kV HV)
Bus Coupler Bay
Bus Works (for two bus )
33kV Equipments
33kV Isolator (3-Ph)
Without E/S
With E/S
33kV Circuit Breaker
Current Transformer
33kV Current Transformer (single phase) for Transformer with Junction Box
33kV Current Transformer (single phase) for Line with Junction Box
30kV Surge Arrestor
33 kV PT (single phase) with Junction Box
33 kV Bus Post Insulators/Solid core insulator
2*5 MVAR Capacitor bank
33kV Circuit Breaker
33kV Isolator with earth link
33kV Isolator without earth link
Single phase Reactor
33 KV NCT
33 KV Control and relay panel
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
33kV 1 Main+1 Transfer
Line bay
Transformer Bay 33KV
Bus Coupler Bay
Bus Works (for two Bus)
Capacitor bank
Substation Automation
Complete substation automation system including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications
Bay Control Units
I) 220kV system
II) 132kV system
III) 33kV system
AC Kiosks
I) 220kV system
II) 132kV system
III) 33kV system
Online Monitoring, Data Acquisitionand ABT Analysis System
ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only.
DCU & Accessories
Industrial Grade Network Switch -8 Port, unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation: Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition (Latest) / ORACLE (Latest)
MS office - Standard edition (Latest)
MacAfee Virus Scan Enterprise Desktop Edition (Latest) - Per Year
Local Energy Monitoring Software - Professional edition
LAN cable (average one roll per S/S 300 Meters) Cat-06
PVC conduit Pipe - 3/4" ISI Mark
Enclosure for LAN Switch
3G/4G/5G Data enable SIM
Cable 4 Core 2.5 Sq. mm Copper, Armored
SDH/MUX EQUIPMENT
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
220 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1+Main 2)
Bus Bar Protection Panel
220kV ( bus bar protection) 2 Main+1 Transfer
Transformer Protection Panel
132 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel
Transformer protection panel
For 220/132kV LV side
For 132/33kV HV side
Other/common equipments pertaining to C&R system
Time synchronisation equipment (GPS based)
PLCC for 220KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Phase )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
PLCC for 132KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Earth )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
EPAX (24/8) with 24 telephones, cables etc.
33KV control and relay panel
33 KV Tripple Feeder Control and Relay Panel
Testing & Maintenance Equipment
Insulation Tester Meter 15 KV Multirange (Motorized)
Automatic capacitor and Tan Delta measuring kit
Digital Multi meter
Leakage tester (Tong type) 1500 Amps
Signal generator
Micro-ohm meter
Gapless zinc oxide LA tester
Oil BDV Kit 0-100 KV
Gas Evacuating and refilling Plant
Winding Resistance Meter
Thermal Imaging Camera
Gas Leakge Monitor
Circuit Breaker Analyser
Dew Point Meter
Battery Earth Fault Locator
Primary Injection Set 1000 Amp
Relay Test Kit
D-Spanner set (Insulated), Ring-Spanner set (Insulated) & Torque Wrench set. Each set shall be a complete set including all standard sizes.
Insulating Gloves & Helmets
Hydraulic Ladder Battery Operated (Rechargable) upto 300kg capacity & 10 Mtrs height
Spliced ladders 5mtr. & 10mtr.
Spliced ladders 20mtr.
Polyamide or Braided white nylon rope -12 mm, 14 mm & 20 mm of each type
Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements
Shock treatment chart & artificial respiratory system
First-aid box complete with first filling of required medicines, instruments and tools
Danger / Man on line / Break-Down boards of appropriate size
Rain coat, Gum boot and Safety Harness Belt with adequate straps
Air-conditioner
Split AC (Capacity-2T) Max Star rating
Miscellaneous items
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
LT Switchboard
415V Main switchboard
415V AC distribution board
415V MLDB
415V ELDB
220V DCDB
48V DCDB
Batteries
Battery charger system
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
250kVA, 440V DG set alongwith AMF Control panel
Fire Fighting Equipments
50Ltrs Water Mist & CAFS
45 Ltr. Foam Type
20 Kg Co2 Type
4.5kg CO2 type for outdoor kiosk
6 Fire Bucket with stand
Sand Drum (half size) filled with sand
Fire Hut and sand pit
Illumination system
Outdoor Lights LED Type
Indoor Light LED Type for control room and Kiosk
Street Lighting, LED Lights, Solar Type
1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc.
Power Cables Aluminium (XLPE)
3.5cx400 Sq.mm
3.5cx300 Sq.mm
Power cable Aluminium (PVC)
3.5cx70Sq.mm
3.5cx35Sq.mm
4cx16 Sq.mm
4cx6 Sq.mm
Control cable Copper (PVC)
2Cx2.5Sq.mm
4Cx2.5Sq.mm
6Cx2.5Sq.mm
10Cx2.5Sq.mm
Grounding/Earthing system
MS Round 40mm dia
3 mtr deep driven earth electrode 40mm dia
3 meter deep pipe electrode (treated pit)
MS Flat 75 x 12 mm for 220kV Switchyard
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Steel structure
Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
Pipe structure (Auxiliary Equipments Structure)
Mandatory spares as per Annexure-B for the following items:
220 / 132 KV, 160MVA Transformer
132 / 33KV, 40MVA Transformer
245KV Isolator & ES
245KV CVT
145 KV Isolator & ES
145KV CVT
33 KV Isolater &ES
Control and relay panel
Substation Automation
Illumination System
Fire Protection System
DG Set
Battery
Battery Charger
LT switchgear
Erection hardware
Description of Work / Item(s)
Amount
Construction of 220/132/33 KV (2x160 MVA + 2x40 MVA) AIS Substation, Manglore, Haridwar
Not Applicable, Please insert Zero at M14 Cell
Description of Work / Item(s)
Amount
Supply
Transformers
160 MVA, 220/132/11KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
40 MVA, 132/33KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
Nitrogen Injection Fire Prevention & extinguishing system for transformer with MS Tank.
Oil Storage Tank (15 KL)
Oil sampling Bottle, Stainless Steel 2ltrs capacity.
LT Transformers
630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
245kV Equipments
245kV SF6 Circuit breakers (3 Ph.), 2500A, 40kA
245kV (5 Core) Current Transformer (1 Ph.)
For Line, BC, TBC
For Transformer
Junction box for above CT
245kV Capacitive Voltage Transformer (1 Ph.), 4400pf
Junction box for above CVT
245kV Isolators (3-phase)
1600A, 40 KA, isolator with one E/S
1600A, 40 KA, isolator with two E/S
1600A, 40KA, Isolator without E/S (Tandem)
198kV Surge Arrestors
245 kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay
Transfer Bus Coupler Bay
Bus Coupler Bay
Bus Works (for three Bus)
145kV Equipment
145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA
145kV (5 Core) Current Transformer (1 Ph.) with Junction Box
For line feeder
For 220kV Transformer LV
For 132kV Transformer HV
145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
Isolators
145kV (3-phase) (Horizontal Double break)
1250A, 40kA, Isolator with E/S
1250A, 40kA, Isolator without E/S
1250A, 40kA, Isolator without E/S (Tandem)
120kV Surge Arrestors
145kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay (220kV LV & 132kV HV)
Bus Coupler Bay
Bus Works (for two bus )
33kV Equipments
33kV Isolator (3-Ph)
Without E/S
With E/S
33kV Circuit Breaker
Current Transformer
33kV Current Transformer (single phase) for Transformer with Junction Box
33kV Current Transformer (single phase) for Line with Junction Box
30kV Surge Arrestor
33 kV PT (single phase) with Junction Box
33 kV Bus Post Insulators/Solid core insulator
2*5 MVAR Capacitor bank
33kV Circuit Breaker
33kV Isolator with earth link
33kV Isolator without earth link
Single phase Reactor
33 KV NCT
33 KV Control and relay panel
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
33kV 1 Main+1 Transfer
Line bay
Transformer Bay 33KV
Bus Coupler Bay
Bus Works (for two Bus)
Capacitor bank
Substation Automation
Complete substation automation system including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications
Bay Control Units
I) 220kV system
II) 132kV system
III) 33kV system
AC Kiosks
I) 220kV system
II) 132kV system
III) 33kV system
Online Monitoring, Data Acquisitionand ABT Analysis System
ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only.
DCU & Accessories
Industrial Grade Network Switch -8 Port, unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation: Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition (Latest) / ORACLE (Latest)
MS office - Standard edition (Latest)
MacAfee Virus Scan Enterprise Desktop Edition (Latest) - Per Year
Local Energy Monitoring Software - Professional edition
LAN cable (average one roll per S/S 300 Meters) Cat-06
PVC conduit Pipe - 3/4" ISI Mark
Enclosure for LAN Switch
3G/4G/5G Data enable SIM
Cable 4 Core 2.5 Sq. mm Copper, Armored
SDH/MUX EQUIPMENT
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
220 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1+Main 2)
Bus Bar Protection Panel
220kV ( bus bar protection) 2 Main+1 Transfer
Transformer Protection Panel
132 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel
Transformer protection panel
For 220/132kV LV side
For 132/33kV HV side
Other/common equipments pertaining to C&R system
Time synchronisation equipment (GPS based)
PLCC for 220KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Phase )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
PLCC for 132KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Earth )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
EPAX (24/8) with 24 telephones, cables etc.
33KV control and relay panel
33 KV Tripple Feeder Control and Relay Panel
Testing & Maintenance Equipment
Insulation Tester Meter 15 KV Multirange (Motorized)
Automatic capacitor and Tan Delta measuring kit
Digital Multi meter
Leakage tester (Tong type) 1500 Amps
Signal generator
Micro-ohm meter
Gapless zinc oxide LA tester
Oil BDV Kit 0-100 KV
Gas Evacuating and refilling Plant
Winding Resistance Meter
Thermal Imaging Camera
Gas Leakge Monitor
Circuit Breaker Analyser
Dew Point Meter
Battery Earth Fault Locator
Primary Injection Set 1000 Amp
Relay Test Kit
D-Spanner set (Insulated), Ring-Spanner set (Insulated) & Torque Wrench set. Each set shall be a complete set including all standard sizes.
Insulating Gloves & Helmets
Hydraulic Ladder Battery Operated (Rechargable) upto 300kg capacity & 10 Mtrs height
Spliced ladders 5mtr. & 10mtr.
Spliced ladders 20mtr.
Polyamide or Braided white nylon rope -12 mm, 14 mm & 20 mm of each type
Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements
Shock treatment chart & artificial respiratory system
First-aid box complete with first filling of required medicines, instruments and tools
Danger / Man on line / Break-Down boards of appropriate size
Rain coat, Gum boot and Safety Harness Belt with adequate straps
Air-conditioner
Split AC (Capacity-2T) Max Star rating
Miscellaneous items
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
LT Switchboard
415V Main switchboard
415V AC distribution board
415V MLDB
415V ELDB
220V DCDB
48V DCDB
Batteries
Battery charger system
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
250kVA, 440V DG set alongwith AMF Control panel
Fire Fighting Equipments
50Ltrs Water Mist & CAFS
45 Ltr. Foam Type
20 Kg Co2 Type
4.5kg CO2 type for outdoor kiosk
6 Fire Bucket with stand
Sand Drum (half size) filled with sand
Fire Hut and sand pit
Illumination system
Outdoor Lights LED Type
Indoor Light LED Type for control room and Kiosk
Street Lighting, LED Lights, Solar Type
1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc.
Power Cables Aluminium (XLPE)
3.5cx400 Sq.mm
3.5cx300 Sq.mm
Power cable Aluminium (PVC)
3.5cx70Sq.mm
3.5cx35Sq.mm
4cx16 Sq.mm
4cx6 Sq.mm
Control cable Copper (PVC)
2Cx2.5Sq.mm
4Cx2.5Sq.mm
6Cx2.5Sq.mm
10Cx2.5Sq.mm
Grounding/Earthing system
MS Round 40mm dia
3 mtr deep driven earth electrode 40mm dia
3 meter deep pipe electrode (treated pit)
MS Flat 75 x 12 mm for 220kV Switchyard
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Steel structure
Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
Pipe structure (Auxiliary Equipments Structure)
Mandatory spares as per Annexure-B for the following items:
220 / 132 KV, 160MVA Transformer
132 / 33KV, 40MVA Transformer
245KV Isolator & ES
245KV CVT
145 KV Isolator & ES
145KV CVT
33 KV Isolater &ES
Control and relay panel
Substation Automation
Illumination System
Fire Protection System
DG Set
Battery
Battery Charger
LT switchgear
Erection hardware
Description of Work / Item(s)
Amount
Civil Works of Substation Area (As per detailed Civil Specification ,Approved design,Materials & Layout)
Buildings
Control room building (Plinth area to be measured). (It can be single or double storey building depending upon availability of space) including parking shed, rain water harvesting ponds, land scaping and park & plantation(As per detailed Civil Specification)
Store shed ( Plinth area to be measured) (As per detailed Civil Specification)
Construction of foundation of following structures including excavation and back filling of earth, CC/ RCC works including centering and shuttering, reinforcement, supply & fixing of bolts etc. complete.
220 KV Tower
220 KV Equipment
Circuit Breaker
Current Transformer (1 Ph.) with junction box
Lightening Arrestor
1600A, 40 KA, isolator with one E/S
1600A, 40 KA, isolator with two E/S
1600A, 40 KA, isolator without E/S
1600A, 40KA, Isolator without E/S (Tandem)
Bus post Insulator
Support Insulator for Wave trap
132 KV Tower
132 KV Equipment
Circuit Breaker
Lightening Arrestor
1250A, 40 KA, isolator with E/S
1250A, 40 KA, isolator without E/S
1250A, 40KA, Isolator without E/S (Tandem)
Bus post Insulator
33 KV Tower
33 KV Equipments
Circuit Breaker
Potential Transformer
Lighting Arrestor
Isolator Without E/S
Isolator With E/S
Bus post Insulator
Transformer
160 MVA 220/132 KV
40 MVA 132/33 KV
630 KVA 33/0.4 KV
400 KVA 33/0.4 KV
Fire Protection Wall between 160 MVA transformers
Fire Protection Wall between 40 MVA transformers
Construction of DG set plinth
RCC Cable trenches with trench covers ( all sections) including all type of crossing and all metallic work to support cables and trench covers.
200 X 200mm size trench with minimum depth 200mm
400 X 400mm size trench with minimum depth 400mm
600 X 600mm size trench with minimum depth 600mm
1000 X 1000mm size trench with minimum depth 1000mm
2 x 1000x1000mm size trench with minimum depth 1000mm
Buried Cable Trenches
RCC roads including provision of footpath ( Whereas necessary), all types of crossings, complete in all manners.
1.80 metre wide
3.75 metre wide
5.00 metre wide
Storm water drain including culverts, sumpwell, sump house and pumps etc.
Security fencing 3.6 mtr high along with gates and security room
Security fencing 3.6 mtr high along with gates
Security Room(Approx. plinth area-32.00 sqm)
Switch yard turfing and antiweed treatment including leveling and dressing of area, PCC and gravels
Construction of tube well with a discharge capacity of 500 lpm with KSB make submersible pumping set of 350 lpm discharge with L&T make panel board including construction of RCC Over Head Water Tank of 50 Kl capacity,15 Mtr staging, including pump house, connecting pipe lines, valves etc complete to ensure proper water supply in building and substations area with one spare pumping set and panel board.
Land Development works
Earth filling in Residential area including cost of earth. Earth to be obtained from outside the sub-station area including its cartage, ramming , watering, dressing in 20 cm thick layer etc. complete.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Residential and Other Civil Works .
Construction of colony and colony roads & drains, water supply mains, fencing for residences and associated land development works.
Construction of 3 no. Type IV, 8 no. Type III, 16 no. Type II and 6 no. Type I residences
Construction of 3.75 m wide RCC road for colony
Construction of colony drains including road side drains
Fencing for residences
Water supply mains
Cost of land development works and protection works for colony , Sewage, rain water harvesting ponds, land scaping and park & plantation in colony area.
RCC roads including all types of crossings
5.00 metre wide RCC Connecting Road for colony
RCC Box type Culvert 2.0 M span
Construction of 3.0m high retaining cum boundary wall having RCC columns at 3.0m C/C and brick panels upto 2.4m from FGL and 600mm barbed wire fencing above these panels with 2 no. RCC bands at FGL and top, including required foundations and construction of gate
Description of Work / Item(s)
Amount
Erection
Transformers
160 MVA, 220/132/11KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
40 MVA, 132/33KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
Nitrogen Injection Fire Prevention & extinguishing system for transformer with MS Tank.
Oil Storage Tank (15 KL)
LT Transformers
630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
245kV Equipments
245kV SF6 Circuit breakers (3 Ph.), 2500A, 40kA
245kV (5 Core) Current Transformer (1 Ph.)
For Line, BC, TBC
For Transformer
Junction box for above CT
245kV Capacitive Voltage Transformer (1 Ph.), 4400pf
Junction box for above CVT
245kV Isolators (3-phase)
1600A, 40 KA, isolator with one E/S
1600A, 40 KA, isolator with two E/S
1600A, 40KA, Isolator without E/S (Tandem)
198kV Surge Arrestors
245 kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay
Transfer Bus Coupler Bay
Bus Coupler Bay
Bus Works (for three Bus)
145kV Equipment
145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA
145kV (5 Core) Current Transformer (1 Ph.) with Junction Box
For line feeder
For 220kV Transformer LV
For 132kV Transformer HV
145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
Isolators
145kV (3-phase) (Horizontal Double break)
1250A, 40kA, Isolator with E/S
1250A, 40kA, Isolator without E/S
1250A, 40kA, Isolator without E/S (Tandem)
120kV Surge Arrestors
145kV Bus Post Insulators
Hardware
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
Line bay
Transformer Bay (220kV LV & 132kV HV)
Bus Coupler Bay
Bus Works (for two bus )
33kV Equipments
33kV Isolator (3-Ph)
Without E/S
With E/S
33kV Circuit Breaker
Current Transformer
33kV Current Transformer (single phase) for Transformer with Junction Box
33kV Current Transformer (single phase) for Line with Junction Box
30kV Surge Arrestor
33 kV PT (single phase) with Junction Box
33 kV Bus Post Insulators/Solid core insulator
2*5 MVAR Capacitor bank
33kV Circuit Breaker
33kV Isolator with earth link
33kV Isolator without earth link
Single phase Reactor
33 KV NCT
33 KV Control and relay panel
Insulator strings, Disc Insulators, Hardware, Conductor, 4" IPS Aluminium tube, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for the following
33kV 1 Main+1 Transfer
Line bay
Transformer Bay 33KV
Bus Coupler Bay
Bus Works (for two Bus)
Capacitor bank
Substation Automation
Complete substation automation system including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications
Bay Control Units
I) 220kV system
II) 132kV system
III) 33kV system
AC Kiosks
I) 220kV system
II) 132kV system
III) 33kV system
Online Monitoring, Data Acquisitionand ABT Analysis System
ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only.
DCU & Accessories
Industrial Grade Network Switch -8 Port, unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation: Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition (Latest) / ORACLE (Latest)
MS office - Standard edition (Latest)
MacAfee Virus Scan Enterprise Desktop Edition (Latest) - Per Year
Local Energy Monitoring Software - Professional edition
LAN cable (average one roll per S/S 300 Meters) Cat-06
PVC conduit Pipe - 3/4" ISI Mark
Enclosure for LAN Switch
3G/4G/5G Data enable SIM
Integration of station metering system with centrlized data system including all hardware and software required.
Cable 4 Core 2.5 Sq. mm Copper, Armored
SDH/MUX EQUIPMENT
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
220 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1+Main 2)
Bus Bar Protection Panel
220kV ( bus bar protection) 2 Main+1 Transfer
Transformer Protection Panel
132 kV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel
Transformer protection panel
For 220/132kV LV side
For 132/33kV HV side
Other/common equipments pertaining to C&R system
Time synchronisation equipment (GPS based)
PLCC for 220KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Phase )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
PLCC for 132KV Line feeder
Line Traps
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Earth )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
EPAX (24/8) with 24 telephones, cables etc.
33KV control and relay panel
33 KV Tripple Feeder Control and Relay Panel
Air-conditioner
Split AC (Capacity-2T) Max Star rating
Miscellaneous items
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
LT Switchboard
415V Main switchboard
415V AC distribution board
415V MLDB
415V ELDB
220V DCDB
48V DCDB
Batteries
Battery charger system
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
250kVA, 440V DG set alongwith AMF Control panel
Fire Fighting Equipments
50Ltrs Water Mist & CAFS
Fire Hut and sand pit
Illumination system
Outdoor Lights LED Type
Indoor Light LED Type for control room and Kiosk
Street Lighting, LED Lights, Solar Type
1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc.
Power Cables Aluminium (XLPE)
3.5cx400 Sq.mm
3.5cx300 Sq.mm
Power cable Aluminium (PVC)
3.5cx70Sq.mm
3.5cx35Sq.mm
4cx16 Sq.mm
4cx6 Sq.mm
Control cable Copper (PVC)
2Cx2.5Sq.mm
4Cx2.5Sq.mm
6Cx2.5Sq.mm
10Cx2.5Sq.mm
Grounding/Earthing system
MS Round 40mm dia
3 mtr deep driven earth electrode 40mm dia
3 meter deep pipe electrode (treated pit)
MS Flat 75 x 12 mm for 220kV Switchyard
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Steel structure
Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
Pipe structure (Auxiliary Equipments Structure)
Description of Work / Item(s)
Amount
Total Price CIP in EUR (Schedule 1)
Total Price CIP in USD (Schedule 1)
Total Price CIP in JPY (Schedule 1)
Total Price of Import Duty in INR (Schedule 1)
Total Price EXW in INR (Schedule-2)
Total Price of Design Services in INR ( Schedule-3)
Total Price of Incidental Expenses in INR( Schedule-4A)
Total Price of Civil Works in INR(Schedule - 4B)
Total Price of Erection including Testing and Commissioning in INR(Schedule - 4C)
M/s. Vijai Electricals Limited
TRANSGLOBAL POWER LIMITED
TRANSGLOBAL POWER LIMITED
M/s. Vijai Electricals Limited
M/s. Vijai Electricals Limited
TRANSGLOBAL POWER LIMITED
M/s. Vijai Electricals Limited
US Dollar
European Euro
Japanese Yen
US Dollar
European Euro
Japanese Yen
US Dollar
European Euro
Japanese Yen
US Dollar
European Euro
Japanese Yen
Description of Work / Item(s)
40 MVA, 132/33KV, Three phase Transformer including first filling of oil, alongwith, Online DGA Multigas type and Fibre Optic Temperature Measurement System and all related equipments.
Nitrogen Injection Fire Prevention & extinguishing system for transformer with MS Tank.
Oil Storage Tank (15 KL)
630KVA, 33/0.433KV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil)
245kV SF6 Circuit breakers (3 Ph.), 2500A, 40kA
For Line, BC, TBC
For Transformer
Junction box for above CT
245kV Capacitive Voltage Transformer (1 Ph.), 4400pf
Junction box for above CVT
1600A, 40 KA, isolator with one E/S
1600A, 40 KA, isolator with two E/S
1600A, 40KA, Isolator without E/S (Tandem)
198kV Surge Arrestors
245 kV Bus Post Insulators
Line bay
Transformer Bay
Transfer Bus Coupler Bay
Bus Coupler Bay
Bus Works (for three Bus)
145kV SF6 Circuit breakers (3 Ph.), 1600A,40kA
For line feeder
For 220kV Transformer LV
For 132kV Transformer HV
145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box
1250A, 40kA, Isolator with E/S
1250A, 40kA, Isolator without E/S
1250A, 40kA, Isolator without E/S (Tandem)
120kV Surge Arrestors
145kV Bus Post Insulators
Line bay
Transformer Bay (220kV LV & 132kV HV)
Bus Coupler Bay
Bus Works (for two bus )
Without E/S
With E/S
33kV Circuit Breaker
33kV Current Transformer (single phase) for Transformer with Junction Box
33kV Current Transformer (single phase) for Line with Junction Box
30kV Surge Arrestor
33 kV PT (single phase) with Junction Box
33 kV Bus Post Insulators/Solid core insulator
2*5 MVAR Capacitor bank
33kV Circuit Breaker
33kV Isolator with earth link
33kV Isolator without earth link
Single phase Reactor
33 KV NCT
33 KV Control and relay panel
Line bay
Transformer Bay 33KV
Bus Coupler Bay
Bus Works (for two Bus)
Capacitor bank
Complete substation automation system including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications
I) 220kV system
II) 132kV system
III) 33kV system
I) 220kV system
II) 132kV system
III) 33kV system
ABT meters 0.2s Cl with TCPIP, Optical Communication Port (ABT Meters are the part of C&R Panel. The rates of same may be included in the rates of C&R Panel). The quantity mentioned here for Supply & Erection is for indication purpose only.
DCU & Accessories
Industrial Grade Network Switch -8 Port, unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation: Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition (Latest) / ORACLE (Latest)
MS office - Standard edition (Latest)
MacAfee Virus Scan Enterprise Desktop Edition (Latest) - Per Year
Local Energy Monitoring Software - Professional edition
LAN cable (average one roll per S/S 300 Meters) Cat-06
PVC conduit Pipe - 3/4" ISI Mark
Enclosure for LAN Switch
3G/4G/5G Data enable SIM
Cable 4 Core 2.5 Sq. mm Copper, Armored
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1+Main 2)
220kV ( bus bar protection) 2 Main+1 Transfer
Transformer Protection Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel
For 220/132kV LV side
For 132/33kV HV side
Time synchronisation equipment (GPS based)
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Phase )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
2000A, 0.5 mH/1.0 mH, 40 kA
Coupling device ( Phase to Earth )
HF Cable
Carrier Equipment (for speech+protection and for speech+Data)
Protection Coupler
EPAX (24/8) with 24 telephones, cables etc.
33 KV Tripple Feeder Control and Relay Panel
Insulation Tester Meter 15 KV Multirange (Motorized)
Automatic capacitor and Tan Delta measuring kit
Digital Multi meter
Leakage tester (Tong type) 1500 Amps
Signal generator
Micro-ohm meter
Gapless zinc oxide LA tester
Oil BDV Kit 0-100 KV
Gas Evacuating and refilling Plant
Winding Resistance Meter
Thermal Imaging Camera
Gas Leakge Monitor
Circuit Breaker Analyser
Dew Point Meter
Battery Earth Fault Locator
Primary Injection Set 1000 Amp
Relay Test Kit
D-Spanner set (Insulated), Ring-Spanner set (Insulated) & Torque Wrench set. Each set shall be a complete set including all standard sizes.
Insulating Gloves & Helmets
Hydraulic Ladder Battery Operated (Rechargable) upto 300kg capacity & 10 Mtrs height
Spliced ladders 5mtr. & 10mtr.
Spliced ladders 20mtr.
Polyamide or Braided white nylon rope -12 mm, 14 mm & 20 mm of each type
Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements
Shock treatment chart & artificial respiratory system
First-aid box complete with first filling of required medicines, instruments and tools
Danger / Man on line / Break-Down boards of appropriate size
Rain coat, Gum boot and Safety Harness Belt with adequate straps
Split AC (Capacity-2T) Max Star rating
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
415V Main switchboard
415V AC distribution board
415V MLDB
415V ELDB
220V DCDB
48V DCDB
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
250kVA, 440V DG set alongwith AMF Control panel
50Ltrs Water Mist & CAFS
45 Ltr. Foam Type
20 Kg Co2 Type
4.5kg CO2 type for outdoor kiosk
6 Fire Bucket with stand
Sand Drum (half size) filled with sand
Fire Hut and sand pit
Outdoor Lights LED Type
Indoor Light LED Type for control room and Kiosk
Street Lighting, LED Lights, Solar Type
3.5cx400 Sq.mm
3.5cx300 Sq.mm
3.5cx70Sq.mm
3.5cx35Sq.mm
4cx16 Sq.mm
4cx6 Sq.mm
2Cx2.5Sq.mm
4Cx2.5Sq.mm
6Cx2.5Sq.mm
10Cx2.5Sq.mm
MS Round 40mm dia
3 mtr deep driven earth electrode 40mm dia
3 meter deep pipe electrode (treated pit)
MS Flat 75 x 12 mm for 220kV Switchyard
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Lattice structure (Main Structures, Auxiliary Equipments Structures & Lightning Mast Structure)
Pipe structure (Auxiliary Equipments Structure)
220 / 132 KV, 160MVA Transformer
132 / 33KV, 40MVA Transformer
245KV Isolator & ES
245KV CVT
145 KV Isolator & ES
145KV CVT
33 KV Isolater &ES
Control and relay panel
Substation Automation
Illumination System
Fire Protection System
DG Set
Battery
Battery Charger
LT switchgear
Erection hardware
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid