sr xen
XEN OM Division BBMB Jagadhri
Work for getting water proofing treatment provided on the leaking roof of the various non-residential building located at 220KV S/Stn. BBMB, Jagadhri.
2024_BBMB_185931_1
water proffing treatment
Open Tender
Civil Works
Item Rate
90 days
bbmb Jagadhri
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Yes
Sr AO BBMB Dhulkote
₹6,900
6 Jun 2024
13 Feb 2024
29 Feb 2024
13 Feb 2024
27 Feb 2024
13 Feb 2024
13 Feb 2024 - 27 Feb 2024
Amount
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying (NS Item)
a). After surface prepartion first layer of slurry of cement @ 0.458 Kg/Sqm mixed water proofing cement compound @ 0.253 Kg./Sqm b). Laying second layer of fibre glass cloth when the first layer is still green Overlaps of Joints of fibre cloth should not be less than 10 cm. c). Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 Kg/Sqm mixed with water proofing cement compound @ 0.670Kg / sqm and coarse sand @ 1.289 Kg/sqm . This will be allowed to air cure for 4 Hours followed by water curring for 48 Hours. The enrire treatment will be taken upto 30 cm on parapet wall and tucked int groove in parapet all around (NS Item) Note:- Water Leakage Test The water leakage test by retaining minimum 50mm thick layer of water on the surface of roof for 48 Hours shall be conducted at site . If any leakage / dampness is observed during the test, water leakage test shall be repeated after the necessary repair of water proofing treatment.
Top Khurra 0.6mX0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16 (Ref 13.45) T/R
12.5 mm thick cement plaster 1:4 (Ref.15.9) T/R
Cement Concrete 1:6:12 (b) with stone aggregate 40 mm gauge (i) mixing by manual means (Ref 10.8 b(i) T/R
Chem Coating
ORBIT ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .