| 1 | L1₹7.9 CrAccepted-AOC 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹7.9 Cr | L1 | Accepted-AOC Since lowest |
| 2 | L2₹8.7 Cr+₹82.1 L (10.4%)Rejected-Finance 81 SAHAPUR MAIN ROAD PS BEHALA KOLKATA WB PIN 700038 | KOLKATA | WEST BENGAL | 700038 | ₹8.7 Cr+₹82.1 L (10.4%) | L2 | Rejected-Finance Since not lowest bidder |
| 3 | L3₹9.0 Cr+₹1.1 Cr (13.8%)Rejected-Finance | ₹9.0 Cr+₹1.1 Cr (13.8%) | L3 | Rejected-Finance Since not lowest bidder |
| 4 | L4₹9.2 Cr+₹1.3 Cr (16.2%)Rejected-Finance 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹9.2 Cr+₹1.3 Cr (16.2%) | L4 | Rejected-Finance Since not lowest bidder |
| 5 | L5₹9.4 Cr+₹1.5 Cr (18.8%)Rejected-Finance | ₹9.4 Cr+₹1.5 Cr (18.8%) | L5 | Rejected-Finance Since not lowest bidder |
Tender Value
₹8.8 Cr
EMD Value
₹7.7 L
Closing Date
22 Mar 2023, 6:00 pmClosed
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
Office of HQ CE CG Visakhapatnam-530007
As per BOQ
2023_MES_580037_1
CE (CG) /VIZ/FRAZ/TOKEN 21 OF 2022-23
Open Tender
Civil Works
Lump-sum
450 days
FRAZERGANJ
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer I CG and N Kolkata
₹7.7 L
Yes
31 Mar 2023
9 Feb 2023
24 Mar 2023
9 Feb 2023
22 Mar 2023
11 Mar 2023
Amount
Schedule "A" Part – I to Schedule "A" Part – XII: NOTE: Schedule "A" Part – I to Part – XI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lump Sum price worked out by the contractor for "BUILDINGS & STRUCTURES", for the lumpsum price of Rs. 1,61,74,300.00 inserted by MES as listed in Schedule 'A' Part - I
Price worked out by the contractor for "EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT ", against the price of Rs. 49,66,037.66 inserted by MES as listed in Schedule 'A' Part - II
Price worked out by the contractor for "PILE WORK ", against the price of Rs. 39,27,720.56 inserted by MES as listed in Schedule 'A' Part - III
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price of Rs. 40,490.88 inserted by MES as listed in Schedule 'A' Part - IV
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", against the price of Rs. 5,63,843.13 inserted by MES as listed in Schedule 'A' Part - V
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 2,03,740.91 inserted by MES as listed in Schedule 'A' Part - VI
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY, PERIMETER LIGHT AND LIGHTING PROTECTION", against the price of Rs. 28,44,746.34 inserted by MES as listed in Schedule 'A' Part - VII
Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 5,07,418.50 inserted by MES as listed in Schedule 'A' Part - VIII
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 1,26,588.49 inserted by MES as listed in Schedule 'A' Part - IX
Price worked out by the contractor for "ROAD/PATH/HARDSTANDING/CULVERT WORK", against the price of Rs. 41,55,833.15 inserted by MES as listed in Schedule 'A' Part - X
Price worked out by the contractor for "[FENCING / COMPOUND WALL", against the price of Rs. 3,65,44,081.50 inserted by MES as listed in Schedule 'A' Part - XI
Schedule "A" Part - XII [Miscellaneous Items, DG set, Water cooler etc. ]
EXTERNAL WATER SUPPLY
M & L For 2 core 2 sqmm flat copper flexible cable for connecting Monoblock pump with starter drawn through HDPE Pipe of appropriate size for cable protection complete all as specified and directed by Engr-In-Charge..
Supply and fix foot valve confirming to IS 4038, 50mm (2") dia Pipe.
Supply and fix Energy efficient Monoblock pump set, self-priming suitable for 240 V, single phase, electric driven, Discharge - 1820 LPH at head- 10 mtr including suitable medium size channel duly grouted in floor inside bldg for mounting pumpset, foundation bolts complete (1W+1S). Make: Kirloskar/Havells /Crompton/KSB.
Supply and install on line altoch dosing system all as per model NO ADSPRO or equivalent or of equivalent model along with Stequa 411 AE refill and connection pipe inlet &outlet all as directed by Engr-in-Charge. Note(a) Quoted rate is inclusive refill pack of 25 Nos – 04 Packs
Supply, fabricate, install, testing and commissioning of LT Panel board made up of polycarbonate with transparent bus bar, Indoor cubicle type totally enclosed with front and rear opening, 40x40x5mm thick angle iron frame work, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands for various cables, danger plate, nuts/ bolts with 4 Nos copper bus bar of 50 Amps rating each, with suitable colored heat shrinkable insulator sleeves suitable for three phase LT AC, 50 Hz 415 V, necessary internal electric wiring / connection with FRLS cables not less than 2.5sqmm , necessary sleeves IP45 class protection, complete including the following : INCOMER:- (i) MCCB 4 pole, 32 Amps, 415 Volts, 50 HZ 16 KA-01 No. (ii) Digital Voltmeter 0-500V – 01 No (iii) Digital Ammeter 0- 50 Amps.- 01 No OUTGOING:- (i) MCB 2 POLE, 16 AMPS, 415 VOLTS, 50 HZ-02 Nos (ii) Starter suitable for pumps at item No 16 -02 Nos (iii) LED Indicator light RYB - 01 Set. (iv) MCB DP 06 Amps - 01 No
PILE FOUNDATION
Material and labour for Boring for bored cast in situ piles 500mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 50 M using DMC method (Direct and circulation) complete all as specified and directed by Engr-in-Charge.
Material and labour Chipping of laintenance concrete of pile and disposal of spoil to a distance 50 mtrs complete all as specified and directed by Engr-in-Charge.
Carrying out following initial load testing on 500mm dia piles complete all as per IS and as directed including necessary anchoring and support piles of suitable load/size to be casted as required (Quoted rates are inclusive of all these requirements).
(a) Compression test
(b) Pull out test
(c) Lateral test
Carrying out following routine load testing on 500mm dia piles complete all as per IS and as directed including necessary anchoring and support piles of suitable load/size to be casted as required (Quoted rates are inclusive of all these requirements).
(a) Compression test
(b) Pull out test
(c) Lateral test
Carrying out Pile Integrity Test on 500mm dia piles all as per IS and as directed.
SECURITY WALL AND GATE
S&F of Concertina coil 610 mm dia punched barbed wire tape (SRPBT) aluminium base helix coil including necessary GI fixing clip with additional primer treatment epoxy/polyurethane & final paint top coat of Caulified green shade by Hot dipping process complete all as specified and as directed. (i) Weight of each coil ; 8.00 to 8.50 Kg (ii) Coverage per coil: 6.00 to 6.50 RM. Note : Running length of the wall shall be measured for payment purpose
M&L for AAC block masonry in cement mortar 1:4 straight or curved on plan exc 6 mtr mean radius complete all as specified and as directed.
SEWAGE DISPOSAL
M & L for On site LLDPE Septic tank design for 25 Users to carry sewage and sullage water, excavation in type of soil, pcc 1;4:8 below foundation, vent shaft connection etc complete all as specified and as directed.
M & L for 1.2 M dia x 3 M effective depth soakage well excavation in type of soil foundation in pcc 1:3:6, walls of honeycompt machinery with top ring of M-25 concrete including intercepting chamber and screen chamber, made of brick machinery in cm (1:6) Rcc cover slab in M-25, interconnecting pipes of RCC filled with brick bats of size complete all as specified and as directed.
EXTERNAL ELECTRIFICATION AND OBSTRUCTION LIGHT
Supplying & laying XLPE insulated screened PVC embedded, electric cable with stranded aluminium conductor, 1100 volts grade, 2 core, 4 sqmm cross-sectional area, in trenches/trusses/ on wall on floor or through pipe with MS Clamp complete all as specified and as directed.
Supply and fix ,connecting and testing Solid state electronic type aviation obstruction light fitting 302 LED with cast aluminium poly carbonate red colour installed at top of the building with propoer Supports and Clamps /Brackets etc. complete all as directed and specified. Make- Bajaj/Philips/Shyam switch gear
Supply & installation, commissioning and testing of indoor type 63 KVA capacity of type II transformer step down 11/0.433 KV, copper wound, core type winding, AC supply 3 phase, 4 wire 50 HZ, oil immersed ,naturally cooled, delta connected on primary (HT side) and star connected on secondary (LV side) having tapping 0%, 2.5% ,5%, 7.5% on HV, to be charged by means of hand operated off load tap changing gear including first filling of oil and all standard fittings such as breather unit, drain out valve, conservator tank and mounting, complete all as specified in IS-1180: 2014 (Part I) Make:- Alstom / Schneider/ Voltas/ Indian transformer and Electrical. The transformer shall be complete with following fittings and accessories:- (a) HT side(primary) consisting of 03 Nos indoor porcelain bushing with brass rods complete with nuts,bolts and washers complete. (b) LT side(secondary) consisting of 04 Nos indoor porcelain bushing with brass rods, complete with nuts bolts and washers complete. (c) Oil conservator tank with filter type drain valve and oil level gauge. (d) De-hydrating breather with first fill of dehydrating agent(Silica gel). (e) Explosive vent for release of pressure will be provided on the cover. (f) Silica gel breather along with conservator tank will be provided. (g) Two earthing terminal on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of neutral & body. (h) Rating plate and termninal marking plate-02 Nos (j) Oil level guage
(k) Oil drain filter valve (l) 4 Nos Lifting lugs will be provided. (m) Oil filling hole with cap / plug with connecting plate complete. (n) Air release valve plug (o) Four plain solid cast steel heavy duty detachable rollers. (p) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral complete. (q) First filling of new and unused transformer oil IS 335 marked filtered and tested for Di-electric strength not less than 42 KV at 2.0 mm gap between testing electrods. NOTE :- THE TRANSFORMER SHALL BE OF LEVEL-3
Supply, install, testing & commissioning of VCB extended bus bar type indoor type 11 KV 3 phase, 250MVA, 50 HZ, 26.3 KA, HT totally enclosed free standing, sheet steel clad, cubical pattern, HT panel switch board with locking arrangement for panel doors, complete with short time with stand current sec with 3 Nos 630A PVC sleeved copper bus bars and comprising of the followings :- VCB 400A -01 Nos complete all as per latest IS/IEC standards comprising of the followiing:- INCOMING VCBs :- (a) Manually changing & closing mechanism, 1- Motorised spring charged closing mechanism. (i) Mechanical close/strip knob - 01 set (ii) Mechanical ON/OFF indicator - 01 No (iii) Mechanical spring charged / free indicator -01 No (iv) 1- Set of 6 Nos + 6 NC Aux contact block -01 No (v) DC 30 volt, shut strip -01 No (b) 1- Set space heaters 1x60 watt -03 nos, 230V AC with switch humidity sensor and thermostat. ( c) VCB ON & OFF switch, trip circuit heating, auto trip, service position, test position. (d) 1-Set of Red/green indicating lamps for circuit breaker on/off auto trip indication. (e) 3 resin cast type twin secondary current transformer of ratio 300-100/5-5A, class of accuracy 0.5/5P10, burden 10VA/10 VA burden for protection & metering. (f) 1-3 phasing cast draw out type potential transformer ratio 11 KV root 3/ 110 V class 0.5 accuracy, 50 VA/ph burden, complete HT & LT fuses and connected to incoming side ( one per VCB)
(g) Luminous push button for trip circuit check.(h) Microprocessor based numerical relay with local display & communication port. (j) Multifunction Electronic Digital Meter consisting of measurement of current, voltage frequuency, KW, KWH, KWARH etc type PM 500. (k) 1 No- Cut out plate for cable entry for 95 sq mm 3 core cable. (l) PVC FRLS copper cable single core multistranded of size 2.5 sq mm for all control wiring.(m) MCB DP 32A -01 No for control supply. Note: (i) Each VCB triping coil voltage should be 30 VDC.(ii) Quoted rate is inclusive of Power pack unit for backup supply for the relay. (iii) Contractor shall provide drawings of 11 KV VCB panel for approval before procurement. The HT panels shall be factory inspected and routine test shall be carried out in the presence of rep of Accepting Officer.(iv) VCB shall be procured just before completion of the project subjected to go-ahead approval for procurement from GE.
Notes: (i) MAKE OF AUTOMATIC CONTROL PANEL:- ABB/SIEMENS/L&T/SCHNEIDER/C&S (The complete panel shall be procured by the contractor either direclty from these manufacturer's or their authorised dealers only),Make of Capacitors- EPCOS/L&T/BCH, Make of Contactor- ABB/BCH/C&S/SIEMENS,Make of relay- EPCOS/L&T/BCH/SIEMENS. (ii) Cost of all the above mentioend accessories, materials, components, loop earthing itmes and all other relevant works for entire completion of this item all as directed by the GE shall be deemed to be included in the quoted rate of above item and only payment for provision of earthing (other than loop earthing) shall be made for separately.
Supply and install LT BUS bar distribution panel outdoor type polycarbonate with transparent bus bar of suitable size with Aluminium Bus bar of 100Amp, equal size of phase and neutral fixed on suitable insulators and provision of necessary holes for connecting the cables with nut bolts all as directed. Note: (i) Quoted Rate is deemed to be inclusive of necessary PCC foundation and MS angular support.”
Supply, fabricate, install, testing and commissioning of LT Panel board polycarbonate with transparent bus bar, Indoor cubicle type totally enclosed with front and rear opening, 40x40x5mm thick angle iron frame work, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, nuts/ bolts used to be made of rust proof material as per IS: 8623, with 4 Nos copper bus bar of 250 Amps rating , with suitable colored heat shrinkable insulator sleeves suitable for three phase LT AC, 50 Hz 415 V 4 wire, necessary internal electric wiring / connection with FRLS cables not less than 2.5sqmm , necessary sleeves IP45 class protection, as required and provision of the following : FOR INCOMING :- (a) MCCB, 415V , 3 phase, 4 pole , 100 amp, 16 kA with thermal and adjustable magnetic setting and over protection - 1 Nos (b ) Changeover switch 4 pole 100 Amps - 01 Nos (c) Digital type AC Voltmeter, 0-500 Volts - 01 No (e) Digital type ammeter 0-250 amps with CT's - 01 No (f) LED Indicating Lamps RYB - 1 Set FOR OUTGOING :- (a) MCCB , AC, 415Volt , 3 phase, 04 pole 32 amp capacity, 10 kA with adjustable thermal and adjustable magnetic setting and over load protection - 04 No (b ) MCCB, 4 pole, 16 amps, 10KA, 415 Volts - 09 Nos (c) Digital timer for street light/ high mast – 04 Nos (d) Power contactor 20-32A for street light/High Mast – 04 Nos
Material and labour for PVC cable end terminal boxes outdoor type, 30x20cmx10.5cm with PVC door provision of incoming and outgoing cables comprising of MCB 6 Amps DP on porcelain connection, fixed on poles with necessary clamps duly painted all as directed by Engr-in- Charge Model GSJB-3020.
DG SET
Supplying, installing, commissioning & testing of Silent engine generating set with accoustic enclosure as per Latest CPCB-II norms 415 volts 40 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with suitable AMF Panel as per manufacturer's recommendations complete all as specified and directed with the following :- (A) Alternator :- Standard design alternator rated at 40 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722.The Alternator shall be:- i) Insulation class - 'H‘ ii) Temperature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as approved by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System :(a)Lubricating oil filter (b) Lubricating oil pump vi) Air Intake System : (a) Air intake Manifold - Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass, Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xv) Fuel Tank :- As per OEM standard with fuel filling arrangement.”
(C) CONTROL PANEL :- The standard microprocessor based control panel shall be fabricated out of 3.15mm thick CRCA sheet and powder coated in side and out side and shall display as follows:- (i) Voltage of all Three phases, (ii) Current of all Three phases, (iii) Frequency, (iv) Bus bar Chamber with aluminium busbar of cap 100 Amps - 04 Nos, (v) C.T. 100/5 Amps - 03 Nos. (vi) MCCB TPN, of appropriate capacity - 01 No. D) Accoustic Enclosure:- Manufactured by OEM suitable for 40 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set battaries and control panel should be inside the enclosure. (iv) Construction Details/specification are as follows: a) Outer body :As per OEM standard b) Doors :- As per OEM standard c) Sound Insulation :- As per OEM Norms vi) The accoustic should be composite in construction and fully assembled integral unit vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform viii) The DG Set should be provided with external Emergency stop push button ix) The enclosure should be suitably illuminated by LED Lamp fittings. x) The noise level should be 75 dba at 1m under free field conditions. xi) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade
(E) ENGINE INSTRUMENTS PANEL :- All relevant Para meter shall be conventionally displayed on complete panel there by providing easy monitoring of lubricant oil pressure, coolant temperature battery charging ammeter, RPM and hour meter, starting switch etc.
NOTES :- (i) The quoted rate for DG Set is inclusive of PCC foundation. The foundation for DG Set should be made of PCC 1:2:4 type B1 using 20mm graded stone aggregates below the floor level minimum 300mm and 200 mm above floor platform and of suitable size as per manufacturers recommendations complete all as directed by Engineer-in-Charge. (ii) The DG Set shall be suitably derated to suit the climatic conditions of Frazergang (west bengal) so as to give desired output including 10% over load. (iii) The DG Set shall be suitable for auto main failure function. (iv) AMF panel should of same manufacturer as that of DG Set or as recommended by manufacturer's Vendors and it should be CPRI approved. (v) The DHPP (fuel) required for testing of DG sets is deemed to be included in above quoted rate . (vi) Phase I test will be carried out by Engineer-in-charge and phase II test will be carried out in presence of IEM/Testing officer nominated by Accepting Officer For no load, 25%, 50%, 75%, 100% for 11 hour and 110% for 1 hour over load.
EARTHINGS
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 20 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 Mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including galvanised earth lead wire 4.0mm dia size upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by medium grade 50 mm dia 5 mtr long and connected to main control panel and GI pipe 20 mm medium grade as watering pipe including funnel, wire mesh, PCC Pit made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including excavation and earth work all as specified in SSR Part -1, 2010.
Water Cooler
Supply, installation and commisioning of water coller fully stainless steel, electric driven single phase having 40 Ltr. Water storage capacity and nominal cooling capacity 40 Ltr. complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as specified and as directed.
Internal Water supply
Material and labour for Two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. complete all as specified and directed by Engineer-in-Charge
Material and labour for Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed by Engineer-in-Charge
Material and labour for Angle stop Valve of size 15mm bore cast copper alloy chromium plated high pressure screwed for iron pipe and fixed complete all as specified and directed.
Internal Electrification
M & L for 1 X 20 watt LED ceiling/wall mounted lighting fixture with Lamp Lumen not less than 2100 lumen polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed
M & L for 1 X 10 watt LED ceiling/wall mounted lighting fixture with Lamp polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed
M & L for 1 X 15 watt decorative ultra silm square/Round profile liner LED lighting fixture with Lamp polycarbonate ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed
M & L building security light 1 X 35 W LED with electronic drive suitable for 40 mm dia pole fixed to wall & connecting upto ceiling rose with twin core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified & directed.
S&F LED bulb 9 Watt pin type system lumen not less than 770 Lumen complete all as specified and directed.
Supply & fix search light fittings 50W LED Revolving type 360 degree horizontal & 90 degree vertical upto 0.5 km distance clear view and through wireless remote control with left right up down heavy mangnet base for stability.
M&L MCB SPN "Ç" series 16-20 Amps
S & F wall mounted cabin fan 300 mm sweep ivory complete all as specified and directed by Engineer in charge.
M&L MCB SPN "Ç" series 10-16 Amps
M&L MCB SPN "Ç" series 6-32 Amps
Supply and fixing flame proof industrial type exhaust fan 300 mm sweep 230 volts Make- Sudher
EARTH WORK
Supply only Moorum/red bajri, good earth (from outside MoD land) and bringing to the site filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering. complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
BKGL CONSTRUCTION
M/S N C BANERJEE AND SON
S.M.CONSTRUCTIONS
Aggarwal brothers and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .