P K Singh
Office of SE EUDC-III, H-Block Subsatation Kidwai Nagar KESCo Kanpur
Repairing Overhauling and Maintenance of 33 KV VCB breaker installed at different substation of Jajmau, Harrisganj, Naubasta, Daheli Sujanpur and Hanspuram, Divisions Under EUDC-III Kesco. Kanpur.
2020_KESCO_471717_1
01/EUDC-III/2020-21
Open Tender
Repair and Maintenance Services
Item Wise
365 days
Under the area of EUDC-III KESCo Kanpur
As per tender document
2 documents required · 2 mandatory
₹1,180
KESCo
₹20,000
20 Jul 2020
18 May 2020
26 May 2020
18 May 2020
26 May 2020
18 May 2020
Electrical Items :
Overhauling and maintenance of 33 KV Outdoor Type VCB (inc. oiling & greasing of all mechanical parts and proper alignments of poles).
Checking of all electrical circuit of CRP( inc. testing of AC/DC circuit and relay operation w.r.t. annunciation) (with tiny item, MCB, switch socket etc.)
Replacement of fault display unit with alarm (material supplied by contractor)
Repairing of fault display unit with alarm.
Replacement of single phase servo motor for spring charge.
Repairing and rewinding of single phase servo motor for spring charge
Replacement of antipumping relay (material supplied by contractor)
Replacement of Local/Remote switch (material supplied by contractor)
Replacement of close neutral trip switch (material supplied by contractor)
Replacement of drum contact assembly (material supplied by contractor)
Replacement of 24 V DC Tripping/Closing coil (material supplied by contractor)
Replacement of limit switch (material supplied by contractor)
Replacement of 33 kV damage Poles of 33 KV breaker (Poles provided by KESCo.)
Repairing of Master/auxiliary relay of 33 KV CRP
Rewiring of control wiring in between VCB & respective CRP Panel
Testing of VCB's complete/control panel at least once in year
Replacement of C.T. 200/100/1, Provided by KESCo (carriage charge by contractor from store to site and damage CT site to store)
AS Power
S.A. Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tendernotice_1.pdf
Tender Document • 0.48 MB
TENDER-DOCT-01-EUDC-III-2020-21.pdf
Tender Document • 1.90 MB
BOQ_704586.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .