Tender Value
₹70.9 L
EMD Value
₹1.4 L
Closing Date
15 Jul 2026, 1:00 pm
Similar tender results from the same govt authority in the past 3 years.
At BJU :- Provision of facilities in TTE Running Rooms at Par with that of running rooms of Guard/Loco pilots.
SEE26-27-79
SEE26-27-79
Open
6 Months
Bharatpur, Rajasthan
₹0
₹1.4 L
22 Jun 2026
22 Jun 2026
1 Jul 2026
as per (Schedule - A), Annexure "A-1" except steel Reinforcement.
All Items in conneciton with works under CPWD-DSR 2021 with upto date corrections as per
(Schedule - A), Annexure "A-1" except steel Reinforcement.
S No. Item No Description of Item Unit Qty Rate Amount
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement concrete
4.1 of specified grade excluding the cost of centering
and shuttering - All work up to plinth level :
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived cum 20 7365.15 147303
from natural sources : 4 graded stone aggregate
20 mm nominal size derived from natural
5.0 REINFORCED CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified grade
of reinforced cement concrete, excluding the cost
of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
derived from natural sources: 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
Reinforced cement concrete work in walls (any
thickness), including attached pilasters,
buttresses, plinth and string courses, fillets,
5.2 columns, pillars, piers, abutments, posts and
struts etc. above plinth level up to floor five level,
excluding cost of centering, shuttering, finishing
and reinforcement :
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.12S PRE-CAST RCC
5.12 Providing, hoisting and fixing above plinth level cum 3 9673.5 29020.5
up to floor five level precast reinforced cement
concrete work in string courses, bands, copings,
bed plates, anchor blocks, plain window sills and
the like, including the cost of required centering,
shuttering but , excluding cost of reinforcement
with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
6.12S HALF BRICK MASONRY
Half brick masonry with common burnt clay F.P.S.
6.12 (non modular) bricks of class designation 7.5 in
foundations and plinth in :
8.0 CLADDING WORK
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 602.5 1063.45 640728.63
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
7 Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.
9.0 WOOD AND P.V.C. WORK
Providing and fixing 25 mm thick shutters for cup
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board construction
9.20 with frame of 1st class hard wood and well
matched teak 3 ply veneering with vertical grains
or cross bands and face veneers on both faces of
9.20.2 30 mm thick including ISI marked Stainless Steel Sqm 42 2818.5 118377
butt hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing chromium plated brass
curtain rod having wall thickness of 1.25mm with
9.46 two chromium plated brass brackets fixed with
C.P. brass screws and PVC sleeves etc., wherever
necessary complete :
Providing and fixing M.S. grills of required pattern
in frames of windows etc. with M.S. flats, square
or round bars etc. including priming coat with
approved steel primer all complete.
9.48.2 Fixed to openings /wooden frames with rawl Kg 800 197.7 158160
plugs screws etc.
Providing and fixing fly proof galvanized M.S.
wire gauge to windows and clerestory windows
9.51 using wire gauge with average width of aperture
1.4 mm in both directions with wire of dia 0.63
mm all complete.
9.72S BRASS FITTINGS
9.84 Providing and fixing aluminium extruded section Each 35 856.3 29970.5
body tubular type universal hydraulic door closer
(having brand logo with ISI, IS : 3564, embossed
12 on the body, door weight upto 36 kg to 80 kg and
door width from 701 mm to 1000 mm), with
double speed adjustment with necessary
accessories and screws etc. complete.
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS
SHALL BE ISI MARKED)
Providing and fixing aluminium sliding door bolts,
ISI marked anodised (anodic coating not less than
9.96 grade AC 10 as per IS : 1868), transparent or
dyed to required colour or shade, with nuts and
screws etc. complete :
Providing and fixing aluminium tower bolts, ISI
marked, anodised (anodic coating not less than
9.97 grade AC 10 as per IS : 1868 ) transparent or
dyed to required colour or shade, with necessary
screws etc. complete :
Providing and fixing aluminium handles, ISI
marked, anodised (anodic coating not less than
9.100 grade AC 10 as per IS : 1868) transparent or
dyed to required colour or shade, with necessary
screws etc. complete :
Providing and fixing aluminium hanging floor
door stopper, ISI marked, anodised (anodic
9.101 coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour and
shade, with necessary screws etc. complete.
9.105S GYPSUM BOARD PARTITIONS
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
9.119 Providing and fixing factory made P.V.C. door Metre 180 408.25 73485
frame of size 50x47 mm with awall thickness of 5
mm, made out of extruded 5mm rigid PVC foam
sheet, mitred at corners and joined with 2 Nos of
150 mm long brackets of 15x15 mm M.S. square
tube, the vertical door frame profiles to be
17 reinforced with 19x19 mm M.S. square tube of 19
gauge, EPDM rubber gasket weather seal to be
provided through out the frame. The door frame
to be fixed to the wall using M.S. screws of
65/100 mm size, complete as per manufacturer's
specification and direction of Engineer- in-
Providing and fixing factory made panel PVC door
shutter consisting of frame made out of M.S.
tubes of 19 gauge thickness and size of 19 mm x
19 mm for styles and 15x15 mm for top &
bottom rails. M.S. frame shall have a coat of steel
primers of approved make and manufacture.
M.S. frame covered with 5 mm thick heat
moulded PVC 'C' channel of size 30 mm
thickness, 70 mm width out of which 50 mm shall
be flat and 20 mm shall be tapered in 45 degree
angle on both side forming styles and 5 mm
thick, 95 mm wide PVC sheet out of which 75mm
shall be flat and 20 mm shall be tapered in 45
degree on the inner side to form top and bottom
rail and 115 mm wide PVC sheet out of which 75
9.120 mm shall be flat and 20 mm shall be tapered on
both sides to form lock rail. Top, bottom and lock
rails shall be provided both side of the panel. 10
mm (5 mm x 2 ) thick, 20 mm wide cross PVC
sheet be provided as gap insert for top rail &
bottom rail, paneling of 5 mm thick both side PVC
sheet to be fitted in the M.S. frame welded/
sealed to the styles & rails with 7 mm (5 mm+2
mm) thick x 15 mm wide PVC sheet beading on
inner side, and joined together with solvent
cement adhesive. An additional 5 mm thick PVC
strip of 20 mm width is to be stuck on the interior
side of the 'C' Channel using PVC solvent
adhesive etc. complete as per direction of
Engineer-in-charge, manufacturer's specification
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded in Kg 200 111.95 22390
built up sections, trusses and framed work,
19 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer,
including welding and bolted with special shaped
washers etc. complete.
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
10.28 Providing and fixing stainless steel ( Grade 304) Kg 260 612.25 159185
railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing,
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete, i/c fixing
the railing with necessary accessories & stainless
steel dash fasteners , stainless steel bolts etc., of
required size, on the top of the floor or the side of
waist slab with suitable arrangement as per
approval of Engineer-in-charge, (for payment
purpose only weight of stainless steel members
shall be considered excluding fixing accessories
such as nuts, bolts, fasteners etc.).
11.0 FLOORING
11.2 Dry brick on edge flooring in required pattern Sqm 132 733.3 96795.6
with bricks of class designation 7.5 on a bed of
22 12 mm mud mortar, including filling joints with
local sand, with common burnt clay non modular
11.16S TILE FLOORING
Chequerred precast cement concrete tiles 22
mm thick in footpath & courtyard, jointed with
neat cement slurry mixed with pigment to match
the shade of tiles, including rubbing and cleaning
etc. complete, on 20 mm thick bed of cement
mortar 1:4 (1 cement: 4 coarse sand).
11.20.2 Medium shade pigment using 50% white cement Sqm 415 1160 481400
50% Grey cement
11.37S CERAMIC GLAZED TILES
11.37 Providing and laying Ceramic glazed floor tiles of Sqm 168 935.6 157180.8
size 300x300 mm (thickness to be specified by
the manufacturer) of 1st quality conforming to IS
: 15622 of approved make in colours such as
White, Ivory, Grey, Fume Red Brown, laid on 20
mm thick cement mortar 1:4 (1 Cement : 4
Coarse sand), Jointing with grey cement slurry @
3.3 kg/sqm including pointing the joints with
white cement and matching pigment etc.,
11.41S VITRIFIED FLOOR TILES
Providing and laying vitrified floor tiles in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved
11.41 make, in all colours and shades, laid on 20mm
thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/
s q m including grouting the joints with white
cement and matching pigments etc., complete.
12.0 ROOFING
12.1S SHEET ROOFING
Providing gola 75x75 mm in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 stone
12.21 aggregate 10 mm and down gauge), including
finishing with cement mortar 1:3 (1 cement : 3
fine sand) as per standard design :
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the masonry
12.40 surrounded with 12 mm thick cement mortar of
the same mix, as that of masonry (lead caulking
will be paid for separately):
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
12.41 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised -
PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
12.50 Providing and fixing precoated galvanised iron Sqm 140 671.55 94017
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
0.50 mm (+ 0.05 %) total coated thickness with
zinc coating 120 grams per sqm as per IS: 277, in
240 mpa steel grade, 5-7 microns epoxy primer
on both side of the sheet and polyester top coat
15-18 microns. Sheet should have protective
guard film of 25 microns minimum to avoid
scratches during transportation and should be
supplied in single length upto 12 metre or as
desired by Engineer-in-charge. The sheet shall be
fixed using self drilling /self tapping screws of
size (5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
13.0 FINISHING
13.4S CEMENT PLASTER (IN COARSE SAND)
13.4 12 mm cement plaster of mix :
CEMENT PLASTER WITH A FLOATING COAT OF
12 mm cement plaster finished with a floating
coat of neat cement of mix :
13.25 Extra for plastering:
13.26 Providing and applying plaster of paris putty of 2 Sqm 3400 214.3 728620
33 mm thickness over plastered surface to prepare
the surface even and smooth complete.
Distempering with oil bound washable distemper
13.41 of approved brand and manufacture to give an
13.41.1 New work (two or more coats) over and including Sqm 3000 162.55 487650
water thinnable priming coat with cement primer
13.44S EXTERIOR FINISHING
Finishing walls with Acrylic Smooth exterior paint
of required shade :
35 ltr/10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/10 sqm)
Lettering with black Japan paint of approved letter
brand and manufacture per cm
Applying priming coats with primer of approved
13.85 brand and manufacture, having low VOC (Volatile
Organic Compound ) content.
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
13.91 Removing dry or oil bound distemper, water Sqm 2500 20.85 52125
proofing cement paint and the like by scrapping,
37 sand papering and preparing the surface smooth
including necessary repairs to scratches etc.
Painting with synthetic enamel paint of approved
13.99 brand and manufacture of required colour to give
an even shade :
Finishing walls with water proofing cement paint
of required shade :
13.109.1 Old work (one or more coats applied @ 2.20 Sqm 600 94.15 56490
kg/10 sqm) over priming coat of primer applied
@ 0.80 litrs/10 sqm complete including cost of
15.0 DISMANTLING AND DEMOLISHING
15.3 Demolishing R.C.C. work manually/ by cum 1 2928.1 2928.1
mechanical means including stacking of steel
40 bars and disposal of unserviceable material
within 50 metres lead as per direction of
Engineer - in- charge.
Dismantling doors, windows and clerestory
windows (steel or wood) shutter including
chowkhats, architrave, holdfasts etc. complete
and stacking within 50 metres lead :
Dismantling tile work in floors and roofs laid in
15.23 cement mortar including stacking material within
50 metres lead.
15.56 Dismantling old plaster or skirting raking out Sqm 3000 45.05 135150
joints and cleaning the surface for plaster
including disposal of rubbish to the dumping
ground within 50 metres lead.
17.0 SANITARY INSTALLATIONS
Providing and fixing water closet squatting pan
(Indian type W.C. pan ) with 100 mm sand cast
Iron P or S trap, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with
manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of Each 8 5781.35 46250.8
size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china
pedestal type water closet (European type W.C.
pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever),
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat Each 4 5540.55 22162.2
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal basin
of 430x260x350 mm and 340x410x265 mm sizes
respectively with automatic flushing cistern with
17.4 standard flush pipe and C.P. brass spreaders with
brass unions and G.I clamps complete, including
painting of fittings and brackets, cutting and
making good the walls and floors wherever
17.4.1 One urinal basin with 5 litre white P.V.C. Each 10 5268.85 52688.5
automatic flushing cistern
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
17.7A Providing and fixing wash basin with C.I. Each 10 3459.05 34590.5
brackets, 15 mm dia CP Brass single hole basin
mixer of approved quality and make, including
painting of fittings and brackets, cutting and
making good the walls wherever required:- (a)
White Vitreous China Wash basin size 550x400
mm with a 15 mm CP Brass single hole basin
Providing and fixing Stainless Steel A ISI 304
(18/8) kitchen sink as per IS:13983 with C.I.
brackets and stainless steel plug 40 mm,
including painting of fittings and brackets,
cutting and making good the walls wherever
17.10.2 Kitchen sink without drain board
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with Each 4 299.35 1197.4
flexible tube upto 1 metre long with S.S.
triangular plate to Eureopean type W.C. of quality
and make as approved by Engineer - in - charge.
Providing and fixing P.V.C. low level flushing
cistern with manually controlled device (handle
lever) conforming to IS : 7231, with all fittings
and fixtures complete.
Providing and fixing P.V.C. waste pipe for sink or
17.28 wash basin including P.V.C. waste fittings
17.28.1 Semi rigid pipe
17.31 Providing and fixing 600x450 mm beveled edge Each 10 1411.15 14111.5
mirror of superior glass (of approved quality)
52 complete with 6 mm thick hard board ground
fixed to wooden cleats with C.P. brass screws and
washers complete.
17.33 Providing and fixing 600x120x5 mm glass shelf Each 20 942.15 18843
with edges round off, supported on anodised
53 aluminium angle frame with C.P. brass brackets
and guard rail complete fixed with 40 mm long
screws, rawl plugs etc., complete.
Providing and fixing PTMT towel rail complete
with brackets fixed to wooden cleats with CP
brass screws with concealed fittings arrangement
of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 Each 20 600.35 12007
54 mm, width 78 mm and effective height of 88
mm, weighing not less than 190 gms.
18.0 WATER SUPPLY
18.7S C.P.V.C. PIPES
Providing and fixing G.I. pipes complete with G.I.
18.12 fittings including trenching and refilling etc.-
18.15S BRASS FITTINGS
Providing and fixing brass stop cock of approved
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Providing and fixing uplasticised PVC connection
pipe with brass unions :
18.21.2 45 cm length
Providing and fixing C.P. brass shower rose with
15 or 20 mm inlet :
18.31S C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES
Providing and fixing G.I. Union in G.I. pipe
18.46 including cutting and threading the pipe and
making long screws etc. complete (New work) :
18.48 Providing and placing on terrace (at all floor Litre 11000 9.7 106700
levels) polyethylene water storage tank, IS :
12701 marked, with cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow pipes but without
fittings and the base support for tank.
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
18.54S PTMT FITTINGS
Providing and fixing PTMT bib cock of approved
quality and colour.
18.54.2 15 mm nominal bore, 122mm long, weighing not Each 60 143.3 8598
less than 99 gms
18.59S AIR VALVE & WATER METER (BULK TYPE)
Providing and fixing PTMT extension nipple for
18.75 water tank pipe, fittings of approved quality and
18.75.2 20 mm nominal bore, weighing not less than 40 Each 22 76.5 1683
21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with extruded
built up standard tubular sections/ appropriate Z
sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with
dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at
top, bottom and sides with required EPDM
21.1 rubber/ neoprene gasket etc. Aluminium sections
shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for
21.1.1 For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent or Kg 10 433.95 4339.5
72 dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever
required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall be paid
for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of Kg 10 564.8 5648
powder coating 50 micron)
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc.
21.3 complete as per the architectural drawings and
the directions of engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic
21.3.2 With float glass panes of 5 mm thickness (weight Sqm 12 1325.55 15906.6
not less than 12.50 kg/sqm)
22.0 WATER PROOFING
22.6 Providing and laying water proofing treatment on Sqm 1060 585.55 620683
roofs of slabs by applying cement slurry mixed
with water proofing cement compound consisting
of applying: (a) after surface preparation, first
layer of slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @ 0.253
kg/sqm. (b) laying second layer of Fibre glass
cloth when the first layer is still green. Overlaps
of joints of fibre cloth should not be less than 10
cm. (c) third layer of 1.5 mm thickness consisting
75 of slurry of cement @ 1.289 kg/sqm mixed with
water proofing cement compound @ 0.670
kg/sqm and coarse sand @ 1.289 kg/sqm. This
will be allowed to air cure for 4 hours followed by
water curing for 48 hours. The entire treatment
will be taken upto 30 cm on parapet wall and
tucked into groove in parapet all around. (d)
fourth and final layer of brick tiling with cement
mortar (which will be paid for separately. For the
purpose of measurement the entire treated
surface will be measured.
22.14 Grading roof for water proofing treatment with
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand cum 53 7510.75 398069.75
: 4 graded stone aggregate 20mm nominal size)
Schedule Schedule A 3-Items of steel reinforcement udner DSR-2021.
Item- 01 Items of steel reinforcement udner DSR-2021.
S No. Item No Description of Item Unit Qty Rate Amount
5.0 REINFORCED CEMENT CONCRETE
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Fe- Kg 478 89.65 42852.7
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ApprovedTenderDocument79.pdf Tender Document
ATTACHMENT
PolicyRBCE6dt.17.05.2004.pdf
ATTACHMENT
TelecomCircular9-2023.pdf
ATTACHMENT
B.Gsubmissionguideline_.pdf
ATTACHMENT
ApprovedTenderDocument79.pdf
ATTACHMENT
Download all tender documents and submit your bid