| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC C 311 IIND FLOOR RAMPHAL CHOWK PALAM EXTENSION SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹40.3 L+₹1.7 L (4.37%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | L3₹47.2 L+₹8.6 L (22.3%)Rejected-Finance 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Highest | |
| 4 | L4₹47.3 L+₹8.8 L (22.7%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L4 | Rejected-Finance Highest | |
| 5 | L5₹49.3 L+₹10.7 L (27.9%)Rejected-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | L5 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹86,740
Closing Date
23 Nov 2020, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Electrical Division, PWD B and R Br., Ambala Cantt.
Upgradation of Civil Hospital at Ambala Cantt. from 100 Bedded to 200 Bedded in Ambala Distt. (Pdg. Fire Alarm and PA System).
2020_HRY_150200_1
PWD/Elect-KNL/Elect-AMB/110097
Open Tender
Construction Works
Works
120 days
Ambala Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹86,740
19 Apr 2021
9 Nov 2020
24 Nov 2020
9 Nov 2020
23 Nov 2020
9 Nov 2020
Amount
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: Bosch FPA 1000 Series / Cerberus by Siemens, Edwards EST3, Honeywell Moreley Zxe Series.
SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work. Make : (BOSCH FMR-1000-RCMD, Cerberus by Siemens ,Morley ZXRA , Edwards 3-LCD ANN).
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440, Siemens Cerberus OH921+DB-11, Honeywell Morley HM-PTSE+B501, Edwards SIGA PHD+SIGA
SITC of addressable Heat Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panelcurrent and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. (Make: BoschFAH-440+FAA-440, Siemense Cerberus HI921+DB-11, Honeywell Morley HM-RHSE+B501, EdwardsSIGA DHI+SIGA).
Supply, installation, testing & commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Bosch FMM-325A-D,Siemens Cerberus HMS-S, Morley MI-MCP, Edwards SIGA 278
Supply, installation, testing & commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make :Bosch /Siemens Cerberus / Morley / Edwards
Supply, installation, testing & commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : (Bosch FLM-325-2I4, Siemens Cerberus HTRI-M, Morley MI-DMMI, Edwards EST 3).
Supply, installation, testing & commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Bosch /Siemens Cerberus / Morley / Edwards.
SITC of UL/EN54/LPCB listed and FM Approved Fault Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Makes :Bosch /Siemens Cerberus / Morley / Edwards
Supply Installation, Testing & Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/Giolite/OMEX.
SITC of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj
SITC of battery backup for controllers ( 5 KVA UPS on line with 2 hours backup ) Make Libert,Microtek,Eton.
Supply & erection of FIRE EXTINGUISHERS duly hang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire). ABC Dry power type fire Extinguishers of 5 kg. capacity
Co2 type fire extinguishers of 4 Kg capacity
SITC of PVC unsheathed s/c stranded ( ISI marked ) copper contuvtor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work MAKE FINOLEX/POLYCAB/Plaza. PVC unsheathed copper size 1.5 sq mm single core
SITC of Booster amplifier 480 watts Frequency response: 60 Hz to 15 khz (+1/3db), Inputs :XLR & phone jack , Input 1, Input 2-4, Impendence :20kΩ, Sensitivity : 1 V balanced , S/N >: >85 dB complete in all respect Make /BOSCH/ Henrich/Honeywell
SITC of Horn Loudspeaker 15 watts . Max power 22.5 W, Rated power (PHC) 15 W ( 15,7.5,3.75 W) ,Sound pressure Level rated power 103dB ( At 1kHz,Iw,Im), Effective frequency range (-10dB) 500Hz to 5KHz ,Opening angle (at 1 kHz/4kHz,-6 dB), Rated voltage 100V . Rated impedance 667ohm. Ambient temperature range -25 to +55 C .Connection 4 wire cable, 50 cm long complete in all respect Make /BOSCH/ Henrich/Honeywell
SITC of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 Make /BOSCH/ Henrich/Honeywell
Supply, installation, testing & commissioning of 17 U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks.
Wiring for PA system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Plaza. 2 x 1.5 sq.mm
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. HSR Items 31.40 25 mm dia HRS Items 31.44(b)
Vowels Technology and Services
Hytek Turnkey Projects Pvt. Ltd.
Insat Techno Services
Netromics Engineering Solutions Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .