Superintending Engineer
Superintending Engineer O and M Circle 26 Civil Lines Roorkee
Annual Preventive Maintenance of 66 KV Substation Thithki and associated Transmission Lines
2026_PTCUX_102464_1
T-42/SE(OandM)CR/2026-27
Open Tender
Electrical Works
Item Wise
365 days
Thithki, Roorkee
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
SE O and M PTCUL Roorkee
₹25,000
Yes
16 Nov 2026
16 Nov 2026
16 Dec 2026
16 Nov 2026
15 Dec 2026
16 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Preventive maintenance of 66 KV substation Thithki consisting of 2×15 MVA (66/33 KV) transformers, 06 no. 66 KV bays, 08 no. 33 KV indoor bays by carrying out following miscellaneous works on routine basis and round the clock availability of a team comprising the following technical personal-
(i) Technician/ fitter - 01 No.
(ii) Skilled coolie/ line man - 01 No.
(a) Routine visual checking of red hot points, flashpoints, burned jumpers etc. in switchyard. General routine maintenance of outdoor equipments/panels in switchyard i.e. CBs, isolators, bus bars, CTs, PTs/CVTs, marshalling kiosks etc. including scheduled cleaning, lubrication, tightening of connections/jumpers, replacement of minor damaged parts of equipments, replacement of jumpers/clamps/connectors etc. as per direction of engineer incharge.
(b) Routine cleaning of all type of transformers, their marshalling boxes, OLTC etc., maintenance of cooling fans i.e oiling, greasing, cleaning etc., LT electrical connections, tightening of loose connections as per direction of engineer incharge.
(c) Routine checking of complete length of control cables and power cables between indoor panels/equipments and outdoor equipments/kiosks/panels, cleaning, replacement of damanged/burned cables, tightening & replacement of damaged terminals/connections/lugs etc., re-ferruling whenever required.
(d) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room & battery cells, maintaining fluid level, specific gravity, applying of petroleum jelly etc. as per direction of engineer incharge.
(e) Routine maintenance of indoor panels in control room i.e. control & relay panels, ACDB & DCDB system, indoor & outdoor illumination system etc. including scheduled cleaning, lubrication, tightening of connections/terminals, replacement of minor damaged parts of panels, tracing of circuits etc. as per direction of engineer incharge.
(f) Attending minor breakdowns such as replacement of damaged jumpers, replacement of burnt and damaged equipments (bus bar, isolators, CT/PT/CVT) parts, replacement of burnt/damaged CT/PTs, replacement of damaged/burned HT/LT connections and peripherals etc. excluding works which require equipment specific technical expertise and special T&P etc. such as repair of transformers, CBs etc. as per direction of engineer incharge.
(g) Any other routine substation electrical maintenance related works assigned by engineer incharge as and when required. | 12 | Month | - | - |
| 2 | Work of Patrolling of the following lines- | - | - | - | - |
| 3 | 66 KV D/C Thithki-Roorkee Line (10 times x 9 = 90 km) | 90 | Km | - | - |
| 4 | 66 KV D/C Thithki-Mohammadpur Line (10 times x 10.1 = 101 km) | 101 | Km | - | - |
| 5 | Work of lopping - chopping of the trees under and near the line gallery for following lines- | - | - | - | - |
| 6 | 66 KV D/C Thithki-Roorkee Line (4 times x 9 = 36 km) | 36 | Km | - | - |
| 7 | 66 KV D/C Thithki-Mohammadpur Line (4 times x 10.1 = 40.4 km) | 40.4 | Km | - | - |
| 8 | Work of Thermoscanning of the 66 KV lines which includes thermoscanning of all tension towers, jumpers, clamps, connectors etc. of the following 66 KV lines: | - | - | - | - |
| 9 | 66 KV D/C Thithki-Roorkee Line (10 times x 9 = 90 km) | 90 | Km | - | - |
| 10 | 66 KV D/C Thithki-Mohammadpur Line (10 times x 10.1 = 101 km) | 101 | Km | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
DOC.pdf
Tender Documents • 0.84 MB
BOQ_120643.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .