| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC acceptance of letter | |
| 2 | L2₹7.9 L+₹1.2 L (17.4%)Rejected-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L2 | Rejected-AOC not being L1 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD KOCHI
AGE I R AND D KOCHI, THRIKKAKARA,KAKKANAD, KOCHI 682021
REPAIR MAINTENANCE OF COOLING APPLIANCES IN TECHNICAL BUILDINGS AT NPOL KOCHI UNDER AGE I R D KOCHI
2023_MES_598887_1
8227E8AGERDK
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I RD KOCHI
As per tender doucuments
6 documents required · 6 mandatory
₹500
Yes
AGE I R AND D KOCHI
₹17,000
Yes
21 Aug 2023
27 May 2023
1 Jul 2023
27 May 2023
29 Jun 2023
10 Jun 2023
Amount
Taking down old indoor/outdoor units of split type AC of any make/type having capacity 1/1.5/2 TR for servicing, cleaning properly with chemical substance at site with replacing the defective parts as required for OTM accommodation in scattered area of NPOL Kakkanadu and refixing the same on its original position all as directed by Engr- in - charge. (Required items will be measured and paid separately)
All as per Item No 01 above but for window type AC of capacity 1.5/2.0 Ton all as specified and as directed by Engineer in charge .
M&L for water servicing of water cooler of capacity 40/80 to 75/150 Ltr including cleaning of water cooler tank after disconnecting the incoming water supply connection and re fix the same on its original position after cleaning all as specified and as directed by Engineer in Charge.
Supply and charge following refrigerant gas as suitable for existing AC's/ Refrigerators and water cooler of any size/make including copper strainer and capillary tube etc as per site requirement including testing all as specified and as directed by Engineer in charge . Note: Nitrogen gas test shall be done prior to the filling and leakage if any shall be arrested.
(a) R22 Gas
Supply only Capacitor 36/45 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron)
Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron)
Supply only Capacitor 80/100 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron)
Taking out existing burnt fan motor single phase 230 Volt from the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the following all as specified and as directed by Engineer - in - Charge.
Split /window type AC capacity up to 1.5 Ton
Split/ window type AC 2.0 Ton Capacity
Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR
Taking out old unserviceable PCB and replace the same with new PCB at site suitable for Tower AC of capacity 3/4TR ( Indoor/Outdoor) Make : LG/Blue star/Voltas or equivalent.
Taking out carefully existing defective sealed unit compressor and supply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge.
window type AC capacity up to 1.5/2.0 Ton
Split type Ac 1.5/2.0 Ton capacity.
Refrigerator capacity of 165/190/240/285/310 ltrs.
water cooler capacity of 40/80, 60/120 & 75/150 ltrs.
M & L , Sealed compressor unit suitable for 3-4 TR capacity 3 phase ductable split/Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning ,including taking down of old u/s one, all as specified and as directed. .
M&L for removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge.
M & L for refrigerant piping for Split type AC 1.5/2.0 TR and Tower AC 3.0/4.0 TR with nitrile rubber insulation between indoor and outdoor units for split/Tower Ac units exceeding for 3.0 Mtrs complete all as specified and as directed by Engineer in charge.
M & L for PVC drain pipe upto 25mm for connecting to nearest drain lines including chasing, drilling passing through on wall / Terrace complete all as specified and as directed by Engineer in charge.
Taking out defective thermostat & supply and fixing new thermostat for refrigerator suitable for capacity of 165 / 286 / 310 Liters complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA.
Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS.
Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS.
Supply only over load protector for window type AC/Split type AC complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL.
Supply only split type AC indoor unit oscillation motor complete all as directed by Engineer - in - Charge.
Supply only thermostat for split/Window type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA.
Supply and fix replacement 240V 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp SP All as directed EIC .Make: Legrand , Equivalent in L & T/Indo Asian/ havells
Supply and fix in replacement MCB 240 V 50 Hz AC 10 KA , of following rating with necessary lugs for incomming and outgong connections fixed on DB / Enclosure / Panel Boards after taking down the existing MCB of any Make/ rating .Make: MDS Legrand / Indoasian / L & T.
MCB SP 20 to 32 Amp
MCB SPN 32 to 63 Amp
Taking out existing unserviceable flexible cable of any size & Supplying and fixing new copper flexible cable of the following sizes for Water coolers / Window type ACs / Split Acs/ Refrigerator/ Deep freezer etc complete all as directed by Engineer - in - Charge. Make: Poly Cab/Havell's/Finolex .
Flexible copper cable, 3 core, 4 Sq.mm.
Flexible copper cable, 3 core, 2.5 Sq.mm.
Material and labour for spray painting, out door unit of 1.5 Ton / 2.0 Ton capacity split type A/C by two coat of spray painting using super enamel paint over one coat of anticorrosive primer including preparation of old surfaces by scraping etc complete all as specified and directed by Engineer - in - Charge.
Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified and as directed.
M & L Removing the Window/Split A/C /Tower AC unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and out door unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. Note:-topping of gas if required, it will be measured & paid under relevant item.
S & F in repair, starting relay pin type,240V , suitable for Window / Split type AC of any capacity, make or model, all as specified and as directed.
S&F in repair, PVC float valve assembly 15mm bore suitable for water cooler , all as specified and as directed.
S&F in repair, 15 mm bore, lift cock tap, suitable for water cooler , all as specified and as directed.
M & L , Voltage stabilizer 5 KVA by rewinding/replacing the main transformer and replacing PCB, sensing transformer, power relay, connector piece and testing on completion, all as specified and as directed.
All as per item No. 31 here in above, but of 4KVA
M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge.
Repair /replacement of candle for water purifier of suitable size/make for water cooler of capacity 40/80Ltr,60/120Ltr and 75/150Ltr as specified and directed by Engineer in Charge.
Supply and fixing plug top 16 Amp, 230 Volt
Attending the emergent complaint for any type / any time of cooling appliances such as AC of capacity 1 to 4 TR Both window and split type) , water cooler of capacity 40/80, 60/120 and 75/150Ltr and refrigerator of capacity 60 to 190 Ltr installed at technical area of NPOL Kakkanadu, by providing one mechanic and one helper alongwith required tools.
M&L for new sub main wiring with 4 run single core 6.0 sq mm PVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvory colour PVC conduit including multi stranded copper earth conductor 6.0 sq mm two run as earth continuity conductor including taking down the old sub main wiring and all as directed by Engineer in Charge.
Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mm PVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvory colour PVC conduit including multi stranded copper earth conductor 4.0 sq mm two run as earth continuty conductor all as directed by Engr in Charge.
S&F in repairs Swing motor for 1.5 TR / 2 TR indoor unit of split type air conditioner all as directed by EIC.
S&F in repairs indoor unit blower fan for 1.5/2 TR Split AC all as specified and as directed by engineer in charge
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F( in reapirs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
ELAN ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .