Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.3 L+₹1.8 L (8.12%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹24.7 L+₹2.2 L (9.90%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹25.9 L+₹3.4 L (15.3%)Rejected-Finance VILLAGE DHAR P O DASHERA TEH BALH REWALSAR DISTT MANDI HP 175036 | REWALSAR | MANDI | HIMACHAL PRADESH | 175036 | L4 | Rejected-Finance L4 | |
| 5 | L5₹31.1 L+₹8.6 L (38.2%)Rejected-Finance R O VILLAGE DADOH PO DHABAN TEHSIL BALH DISTRICT MANDI HP 175027 | MANDI | HIMACHAL PRADESH | 175027 | L5 | Rejected-Finance L5 |
Tender Value
₹28.8 L
EMD Value
₹50,700
Closing Date
4 Sept 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
JSV Division No. Kullu
C O 31 Nos main outlet chamber and laying, jointing and testing of HDPR pipe
2021_HPIPH_51746_1
9524-73
Open Tender
Civil Works
Item Rate
Dwara
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
Yes
EE
₹50,700
Yes
11 May 2022
28 Aug 2021
6 Sept 2021
28 Aug 2021
4 Sept 2021
28 Aug 2021
120 days
Amount
Excavation in foundation and trenches up to all depths and in all classification of earth work such as pick work, jumper work, situated soil including bailing or pumping out water, blasting soft/ hard rock, chiseling /wedging of soft / hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking, timbering and dewatering wherever required. Stacking usable and unusable material /soil separately and after laying jointing and testing of pipes, returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed with in all leads/ lifts including restoration of un-metalled surfaces to its original conditions and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. Complete in all respects within all leads and lifts as per direction of the Engineer-in-Charge.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size )and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and lifts:- Vertical surfaces such as wall(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like -
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in: - Foundation and plinth
Wall ( any thickness but not less than 0.10 mtrs. Thickness) including attached pillasters buttresses, plinth and string courses etc. from top of foundation level upto floor two level.
Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level i.c cost of binding wire with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
Providing hydrant including GI riser pipe (IS:1239-1990) PP ball valve pump connecting Nipple GI Tee, GI Nipple (As required in main & sub main line) and plain concrete grouting for GI Tee and Riser pipe with in all leads and lifts.
Providing and fixing anchor block and control valve arrangement with cast iron sluice valve including anchor block size 0.30X0.30X0.30 with base for sluice valve 1:2:4 concrete block with in all leads and lifts. 50 mm
P/L and jointing HDPE pipe of various dia complete in all respect with in all leads and lifts and to the entire satisfaction of Engineer-in-charge. 75 mm dia PE 80 PN 4
90 mm dia PE 80 PN 4
125 mm dia PE 80 PN 4
225 mm dia PE 80 PN 4
Robin Thakur
Kimat Ram
Chuni Lal
MOHAMMAD SALMAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .