Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.5 LAccepted-AOC | L-1 | Accepted-AOC AOC |
Tender Value
₹16.9 L
EMD Value
₹33,780
Closing Date
28 Aug 2019, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division PWD B and R Br., Ambala Cantt
Const. of New Building for Govt. Industrial Training Institute Shahabad Distt Kurukshetra (Pdg. Internal EI only) (Recall).
2019_HRY_80635_4
PWD/Elect-KNL/Elect-AMB/10546
Open Tender
Construction Works
Works
180 days
Ambala
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Elect. Division PWD B and R Br
₹33,780
8 Oct 2021
16 Aug 2019
30 Aug 2019
16 Aug 2019
28 Aug 2019
16 Aug 2019
Amount
1 ( c ) Moulded case Circuit breakers. 31.12 Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 1.1 15 amp.to 60 amp. 415 V ,10 KA 3-phase. 31.12 c (i)
1.2 100 amp.to 220 amp.415 V,10 KA 3-phase. 31.12 c (ii)
1.3 250 amp to 300 amp 415 V 35 KA 3 Phase 31.12.c (iii)
1.4 300 amp. to 400 amp. 415 V , 35 KA 3-phase. 31.12 c (iv)
2 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. 31.13 2.1 Size 40 mm x 40 mm x 6 mm. 31.13(ii)
3 M.S.Sheet . 31.14 3.1 Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide. ( i )
4 (K) Distrubution board with plug and socket. 31.15 Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. 4.1 S.P.N. enclosure for single pole MCB 20 amp. 31.15 (ii)
5 Blanking sheet . 31.16 5.1 Supply and erection of blanking sheet in existing distribution board. 31.16 (i)
6 (L) Miniature Circuit Breaker and Isolator. 31.17 Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. 6.1 SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. 31.17a) (ii)
6.2 SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp. 31.17(a) (ii)
6.3 TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp. 31.17(a) (ii)
6.4 TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. 31.17(a) (iii)
7 (M) Supply and erection of Fittings and Accessories. 31.18 7.1 Call bell 220 / 230 volts A.C. bakelite with double coil. 31.18 (vii)
7.2 Bell push with 4 metres 2-core , 0.50 sqmm (16 / 0.20 mm).PVC flexible wire. 31.18 (ix) (a)
7.3 Bakelite angle / straight button holder large size. 31.18 (xi)
7.4 Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. 31.18 (xxiv)
7.5 Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. 31.18 (xxvi)
8 (O) Erection and carriage of fans.. 31.2 8.1 Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. 31.20 (i)
8.2 Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. 31.20 (iii)
8.3 Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick. 31.20 (v)
8.4 Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep. 31.20 (vi)
9 (P) Pipe Laying. 31.21 Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. 9.1 Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed. 31.21 (xxi)
9.2 Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. 31.21 (xxii)
10 (Q) Earthing 31.22 10.1 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. 31.22(iii)
10.2 Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as required. 31.22(iv)
10.3 Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. 31.22(v)
10.4 Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required . 31.22(x)
10.5 Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . 31.22(xi)
10.6 Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required . 31.22(xii)
10.7 Pdg. and laying earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode as required . 31.22(xiii)
10.8 Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. 31.22(xiv)
10.9 Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. 31.22(xv)
10.1 Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . 31.22(xvi)
10.11 Pdg. and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required . 31.22(xvii)
11 (b) Lightning conductor Galvanised iron. 31.24 11.1 Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 metres deep and refilling the same in hills including supply of necessary charcoal / coke and salt mixture. 31.24 (iii)
11.2 Supply and erection of 60 cm. X 60 cm. X 6 mm thick galvanised Iron plate including nacessary bolts and nuts to G.I. tape . 31.24 (iv)
11.3 Pdg. Standard watering tank including down pipe and C.I. cover with locking arrangement etc. 31.24 (v)
11.4 Supply and erection of 20 mm x 3 mm thick lightning conductor G.I. tape fixed with suitable G.I. stapples of same size. 31.24 (vi)
11.5 Supply and erection of G.I. tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with G.I. stapples of same size. 31.24 (vii)
11.6 Supply and erection of 25 mm dia meter 1.5 metre long lightning G.I. tube rod tapered in to a point at the top with 16 cm. X 16 cm x 3 mm thick G.I. base plate and necessary nuts and bolts with washer. 31.24 (viii)
11.7 Prioviding and fixing , testing joint made of 20mm x 3mm thick G.I. strips 125mm long with 4 Nos. G.I. bolts and nuits, check nuts with washer complete. 31.24 (ix)
12 Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 31.26 12.1 10 Sq. mm 2 Core Armoured Cable. 31.26 (iv)
12.2 16 Sq. mm 2 Core Armoured Cable. 31.26 (v)
12.3 25 Sq. mm 3.5 Core Armoured Cable. 31.26 (xxv)
12.4 35 Sq. mm 3.5 Core Armoured Cable. 31.26 (xxvi)
12.5 50 Sq. mm 3.5 Core Armoured Cable. 31.26 (xxvii)
12.6 70 Sq. mm 3.5 Core Armoured Cable. 31.26 (xxviii)
12.7 185 Sq. mm 3.5 Core Cable . 31.26 (xxxii) Ard.
13 Supply and erection of suitable compression type brass cable glands for underground Cable. 31.28 13.1 10 Sqmm to 16 Sqmm Cable 2 to 4 Core . 31.28 (ii)
13.2 25 Sqmm to 50 Sqmm Cable 2 to 4 Core. 31.28 (iii)
13.3 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core . 31.28(iv)
13.4 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core 31.28 (v)
14 (X) Miscellaneous . 31.35 Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. 14.1 15 mm dia. (i) a
14.2 Supply and erection of caution notice plate in three languages. (iii)
14.3 Supply and erection of shock restoration chart in glass frame (iv)
14.4 Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. (ix) 14.5 10 sqmm . (ix) (c)
14.6 16 sqmm . (ix) (d)
14.7 25 sqmm . (ix) (e)
14.8 35 sqmm . (ix) (f)
14.9 50 sqmm . (ix) (g)
14.1 70 sqmm . (ix) (h)
14.11 185 sqmm . 31.35 (ix) (l)
15 (A) PVC Insulated wiring in recessed conduit. 31.36 Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. 15.1 Fan Point - Medium . (i)b
15.2 Fan Point- Long. c
15.3 Light point -Short. (ii)a
15.4 Light Point - Medium. b
15.5 Light Point- Long. c
15.6 Twin control light point with 2 way 5 amp. single pole switch-Short point. (iii) a
15.7 Twin control light point with 2 way 5 amp. single pole switch- Medium point. (iii) b
15.8 Twin control light point with 2 way 5 amp. single pole switch-Long point. (iii) c
15.9 Call bell point including M.S. box of size 180 mmX100mmx60mm deep for call bell - Medium point. (vi) b
15.1 Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long point (vi) c
15.11 3 pin 5 amp. plug point including earthing the 3rd. pin etc. -Short point. 31.36 (vii) a
15.12 3 pin 5 amp plug point including earthing the 3rd. pin etc. - Medium point. 31.36 (vii) b
15.13 3 pin 5 amp. plug point including earthing the 3rd. pin etc.- Long point. 31.36 (vii) c
15.14 3 pin 15 amp.plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable- Medium point. 31.36 (viii) b
15.15 3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated copper conductor cable - Long point. 31.36 (viii) c
16 Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. 31.4 16.1 Size 1.5 sqmm (3 / 0.81mm). 31.40 (i)
16.2 Size 2.50 sqmm (3 / 1.05mm). 31.40 (ii)
16.3 Size 4 sqmm (7 / 0.85mm). 31.40 (iii)
16.4 Size 6 sqmm ( 7 / 1.05mm). 31.40 (iv)
16.5 Size 10 sqmm ( 7 / 1.35mm). 31.40 (v)
16.6 Size 16 sqmm (7 / 1.70mm) 31.40 (vi)
17 Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 31.41 17.1 4-way, SP & N (Horizontal) 31.41 (i)
17.2 12-way, SP & N (Horizontal) 31.41 (iii)
17.3 4-way, TP & N (Horizontal) (8+12) 31.41 (iv)
17.4 8-way, TP & N (Horizontal) (8+24) 31.41 (v)
18 Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. 31.44 18.1 25 mm dia 31.44(b)
19 Supply and erection of copper lugs including crimping etc.upto the entire satisfaction of Engineer-in-Charge of work. 31.45 19.1 1.5 sqmm to 2.5 sqmm 31.45 (a)
19.2 4 sqmm to 6 sqmm 31.45 (b)
19.3 10 sqmm 31.45 (c)
19.4 16 sqmm 31.45 (d)
20 Supply and erection of MS sadles and clamps on wall / RCC parapit for fixing underground cable at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect. 31.48
21 Supply and erection of Socket size rotary step type electronic regulator for A.C. ceiling fan Anchor make Deluxe model No.50440 ISI/SSK make PC 561 operated on 120/280 V A.C. supply complete including cutting of existing bakelite sheet and making necessary connection etc up to the entire satisfaction of Engineer-in-Charge of work. 31.55
22 Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes , iron hooks, cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. 31.58 22.1 PVC pipe of 32 mm dia ( i )
22.2 PVC pipe of 40 mm dia ( ii )
23 Supply, Installation, Testing and Commissioning of wall / free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable tray separating switches compartment and supporting suitable channel duly painted by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The Panel will be complete with control wiring (Copper) and fuse protection. (Only outer area on all sides shall be measured). 31.63
24 Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with color coding heat shrinkable PVC insulation complete in all respect. 31.64
26 Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT panel including fixing the same in position with all labour and material to required to complete the job in all respect. 31.66 26.1 Rotary Handle up to 125 Amp., MCCB ( i )
26.2 Rotary Handle above 125 Amp., MCCB ( ii )
27 S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in charge of work. 31.67 27.1 HDPE 63/50 mm outer dia / inner dia ( i )
27.2 HDPE 90/75 mm outer dia / inner dia ( ii )
28 Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet fixed with rag bolts on wall or on existing pedestal / angle iron frame including bonding to earth Copper bars 63 amp. 415volt 4 bars of 325mm each (Cross section 20x3mm) duly tinned overall size of the chember 375mmx295mmx140mm. 31.76
29 Supply & Erection of MS box of size 8”×10”×4” (20cm×25cm) and 10cm deep made one of 1.6mm thick MS covered with 5mm thick bakelite sheet for fixing of 4no. socket and switch of 6amp. And one no. sock-et and switch Of 15 amp. Including fixing of one no. fuse unit and indicator of approved make. The MS box is recessed in wall including cost of necessary cement sand & mixture required to complete the job in all respect with cost of necessary labour charges for fixing the bakelite sheet and complete then job in all respect up to the entire Satisfaction of Engineer-in-charge of work. NS- 1
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .