Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
9 Sept 2026, 6:00 pm
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
SPECIAL REPAIR / REPLACEMENT OF BER E/M EQUIPMENTS AT AF STATION BARRACKPORE UNDER GE (AF) BARRACKPORE
2026_MES_785296_1
8755/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Barrackpore
Class- D, Category- b(ii)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹97,000
Yes
19 Aug 2026
19 Aug 2026
11 Sept 2026
19 Aug 2026
9 Sept 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down BER cooling appliances (AC's ) from site and deposited to MES store yard complete all as specified and directed. | 28 | Each | - | - |
| 2 | Taking down BER cooling appliances (Water Cooler ) from site and deposited to MES store yard complete all as specified and directed. | 7 | Each | - | - |
| 3 | Taking down BER item (Transformer) from site and deposited to MES store yard complete all as specified and directed. | 2 | Each | - | - |
| 4 | Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 2 Ton with indoor and outdoor unit comprising of the following:-
(a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs.
(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs.
(c) Key features: -
(i) Multi adjustable mode.
(ii) High ambient cooling.
(iii) Super dry.
(iv) Turbo cooling.
(v) Anti microbial air filteration.
(vi) Eco-friendly refrigerant R-32/ R-410A.
(vii) 100% copper.
(viii) Sleep mode.
(ix) Wide voltage range operation.
(x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum).
(xi) Cordless remote - 01 No. | 16 | Each | - | - |
| 5 | Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 1.5 Ton with indoor and outdoor unit comprising of the following:-
(a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs.
(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs.
(c) Key features: -
(i) Multi adjustable mode.
(ii) High ambient cooling.
(iii) Super dry.
(iv) Turbo cooling.
(v) Anti microbial air filteration.
(vi) Eco-friendly refrigerant R-32/ R-410A.
(vii) 100% copper.
(viii) Sleep mode.
(ix) Wide voltage range operation.
(x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum).
(xi) Cordless remote - 01 No. | 12 | Each | - | - |
| 6 | Material and labour for concealed submain wiring comprising single core , 2 Runs of 2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed.
Note :-
(a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates.
2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. | 40 | RM | - | - |
| 7 | Material and labour for concealed submain wiring comprising single core , 2 Runs of 4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed.
Note :-
(a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates.
2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. | 40 | RM | - | - |
| 8 | Supply and fix in repair split AC mounting bracket stand for outdoor unit suitable for 1.5 Ton / 2.0 Ton AC including necessary mounting bolt complete all as specified and directed. | 28 | Each Pair | - | - |
| 9 | Supply and fix in repair copper pipe 5/8" dia for connection indoor and out door unit ISI marked complete all as specified and directed. | 2 | RM | - | - |
| 10 | Supply and fix in repair copper pipe 1/2" dia for connection indoor and out door unit ISI marked complete all as specified and directed. | 2 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdocuments8755.pdf
Tender Documents • 1.20 MB
BOQ_879966.xls
BOQ • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].