Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.8 LAdmitted-Finance 19 1A BOSE PUKAR ROAD KASBA GROUND FLOOR KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | L1 | Admitted-Finance | |
| 2 | L2₹77.4 L+₹18.6 L (31.6%)Admitted-Finance HARSHA KUTHI SIDDHESWARITALA ROAD MONIRAMPORE BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical 20 NO TIKIA MAHAL ORDERLY BAZAR BARRACKPORE DIST 24 PARGANAS NORTH STATE WEST BENGAL PIN 700 120 | BARRACKPORE | 24 PARGANAS NORTH | WEST BENGAL | 700120 | - | Rejected-Technical Rejected due to not enlisted in appropiate category. | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in appropiate category. |
| Sl No | Description | Qty | Unit | Intime Commotrade Pvt Ltd L1 | MERCANTILE AGENCY L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down BER cooling appliances (AC's ) from site and deposited to MES store yard complete all as specified and directed. | 28 | Each | 1,040 ₹29,120 | 1,001 ₹28,028 Lowest |
| 2.00 | Taking down BER cooling appliances (Water Cooler ) from site and deposited to MES store yard complete all as specified and directed. | 7 | Each | 1,040 ₹7,280 | 1,001 ₹7,007 Lowest |
| 3.00 | Taking down BER item (Transformer) from site and deposited to MES store yard complete all as specified and directed. | 2 | Each | 4,975 ₹9,950 Lowest | 15,001 ₹30,002 |
| 4.00 | Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 2 Ton with indoor and outdoor unit comprising of the following:-
(a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs.
(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs.
(c) Key features: -
(i) Multi adjustable mode.
(ii) High ambient cooling.
(iii) Super dry.
(iv) Turbo cooling.
(v) Anti microbial air filteration.
(vi) Eco-friendly refrigerant R-32/ R-410A.
(vii) 100% copper.
(viii) Sleep mode.
(ix) Wide voltage range operation.
(x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum).
(xi) Cordless remote - 01 No. | 16 | Each | 92,540 ₹14,80,640 Lowest | 98,001 ₹15,68,016 |
| 4.10Notes: - (i). Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on parapet wall of building roof top shall deemed to be included in quoted rate. (ii). Rate for scaffolding/ladder/tools and plants required to install Air Conditioner i.e. for making holes to wall, drilling, making good disturbed surfaces and matching with the existing colour shall deemed to be included in quoted rate. (iii) Outdoor unit should be kept above the level of Indoor unit. For installaiton of ground floor ACs oudoor should be on wall surfaces and for first floor ACs should be on parapet wall of roof top of the building with out extra cost to the Govt all as directed by Engr-in-chrg. (iv) The MES No should be painted on indoor and outdoor unit with navy blue colour letters of size not less than 15 mm height. Drain pipe should be clamped up to plinth protection. No extra claim should be allowed for drain pipe from indoor unit to plinth protection of outside the building. (v) The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and making good to the exisitng surface with putty and paint in as specified and directed by Engr-in-charge. | |||||
| 5.00 | Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 1.5 Ton with indoor and outdoor unit comprising of the following:-
(a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs.
(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs.
(c) Key features: -
(i) Multi adjustable mode.
(ii) High ambient cooling.
(iii) Super dry.
(iv) Turbo cooling.
(v) Anti microbial air filteration.
(vi) Eco-friendly refrigerant R-32/ R-410A.
(vii) 100% copper.
(viii) Sleep mode.
(ix) Wide voltage range operation.
(x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum).
(xi) Cordless remote - 01 No. | 12 | Each | 73,138 ₹8,77,656 Lowest | 85,001 ₹10,20,012 |
| 5.10Notes: - (i). Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on parapet wall of building roof top shall deemed to be included in quoted rate. (ii). Rate for scaffolding/ladder/tools and plants required to install Air Conditioner i.e. for making holes to wall, drilling, making good disturbed surfaces and matching with the existing colour shall deemed to be included in quoted rate. (iii) Outdoor unit should be kept above the level of Indoor unit. For installaiton of ground floor ACs oudoor should be on wall surfaces and for first floor ACs should be on parapet wall of roof top of the building with out extra cost to the Govt all as directed by Engr-in-chrg. (iv) The MES No should be painted on indoor and outdoor unit with navy blue colour letters of size not less than 15 mm height. Drain pipe should be clamped up to plinth protection. No extra claim should be allowed for drain pipe from indoor unit to plinth protection of outside the building. (v) The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and making good to the exisitng surface with putty and paint in as specified and directed by Engr-in-charge. | |||||
| 6.00 | Material and labour for concealed submain wiring comprising single core , 2 Runs of 2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed.
Note :-
(a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates.
2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. | 40 | RM | 340 ₹13,600 Lowest | 451 ₹18,040 |
| 7.00 | Material and labour for concealed submain wiring comprising single core , 2 Runs of 4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed.
Note :-
(a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates.
2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. | 40 | RM | 432 ₹17,280 Lowest | 511 ₹20,440 |
| 8.00 | Supply and fix in repair split AC mounting bracket stand for outdoor unit suitable for 1.5 Ton / 2.0 Ton AC including necessary mounting bolt complete all as specified and directed. | 28 | Each Pair | 582 ₹16,296 Lowest | 1,201 ₹33,628 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
21 Sept 2026, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
SPECIAL REPAIR / REPLACEMENT OF BER E/M EQUIPMENTS AT AF STATION BARRACKPORE UNDER GE (AF) BARRACKPORE
2026_MES_785296_1
8755/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Barrackpore
Class- D, Category- b(ii)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹97,000
Yes
8 Oct 2026
19 Aug 2026
23 Sept 2026
19 Aug 2026
21 Sept 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down BER cooling appliances (AC's ) from site and deposited to MES store yard complete all as specified and directed. | 28 | Each | - | - |
| 2 | Taking down BER cooling appliances (Water Cooler ) from site and deposited to MES store yard complete all as specified and directed. | 7 | Each | - | - |
| 3 | Taking down BER item (Transformer) from site and deposited to MES store yard complete all as specified and directed. | 2 | Each | - | - |
| 4 | Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 2 Ton with indoor and outdoor unit comprising of the following:-
(a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs.
(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs.
(c) Key features: -
(i) Multi adjustable mode.
(ii) High ambient cooling.
(iii) Super dry.
(iv) Turbo cooling.
(v) Anti microbial air filteration.
(vi) Eco-friendly refrigerant R-32/ R-410A.
(vii) 100% copper.
(viii) Sleep mode.
(ix) Wide voltage range operation.
(x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum).
(xi) Cordless remote - 01 No. | 16 | Each | - | - |
| 5 | Supply, installation, testing and commissioning of energy rating 5 star, inverter split Air Conditioner capacity 1.5 Ton with indoor and outdoor unit comprising of the following:-
(a) Multi-stranded copper conductor wire 4 core, 2.50 Sqmm not less than 3.0 mtrs with copper lugs.
(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs.
(c) Key features: -
(i) Multi adjustable mode.
(ii) High ambient cooling.
(iii) Super dry.
(iv) Turbo cooling.
(v) Anti microbial air filteration.
(vi) Eco-friendly refrigerant R-32/ R-410A.
(vii) 100% copper.
(viii) Sleep mode.
(ix) Wide voltage range operation.
(x) The ISEER vlaue of Air Conditioner shall be 4.5 (minimum).
(xi) Cordless remote - 01 No. | 12 | Each | - | - |
| 6 | Material and labour for concealed submain wiring comprising single core , 2 Runs of 2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x2.50 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed.
Note :-
(a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates.
2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. | 40 | RM | - | - |
| 7 | Material and labour for concealed submain wiring comprising single core , 2 Runs of 4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete including taking down old unserviciable sub main wiring complete all as specified and directed.
Note :-
(a) Cost for extra length of cables / wire required for connection to MCBs/DB's shall be included in quoted rates.
2. Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. | 40 | RM | - | - |
| 8 | Supply and fix in repair split AC mounting bracket stand for outdoor unit suitable for 1.5 Ton / 2.0 Ton AC including necessary mounting bolt complete all as specified and directed. | 28 | Each Pair | - | - |
| 9 | Supply and fix in repair copper pipe 5/8" dia for connection indoor and out door unit ISI marked complete all as specified and directed. | 2 | RM | - | - |
| 10 | Supply and fix in repair copper pipe 1/2" dia for connection indoor and out door unit ISI marked complete all as specified and directed. | 2 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdocuments8755.pdf
Tender Documents • 1.20 MB
BOQ_879966.xls
BOQ • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .