Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.2 L+₹39,196 (2.84%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹18.2 L+₹4.3 L (31.5%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹21.0 L+₹7.1 L (51.7%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE (Army) Central Jodhpur
GE (Army) Central Multan Line Army Area Jodhpur
RE WIRING REPAIR AND MAINT OF EM FITTINGS AND FIXTURES IN MD ACCN AT AGE BR II IN UNDER GE ARMY CENTRAL JODHPUR (9116/E8)
2022_MES_530391_1
GE/J/A- OF 2022-23 (9116/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (Army) Central Jodhpur
₹40,000
17 Aug 2022
11 Jun 2022
22 Jul 2022
11 Jun 2022
19 Jul 2022
25 Jun 2022
Amount
Note :- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ . (ii) Makes of material will be approved by GE in writing before commencement of work.
Taking down carefully existing copper/aluminium point wiring for light, fan, bell, socket, power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders, bracket, ceiling rose etc removing from site of work, complete all as directed.
M&L for point wiring complete using 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) passing in existing conduit in new / old sunken pressed steel terminal boxes in wall,including 3.00 mm thick plastic laminated hylem sheet top cover and 1.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed :- (a) One light point controlled by one, one way switch
(b) One fan point controlled by one way switch, complete all as specified and as directed.
(c) One socket outlet 3 pin 5/6 Amps on same board, complete all as specified and as directed.
(d) One socket outlet 3 pin 5/6 Amp on independent board, complete all as specified and as directed.
(e) One bell point controlled by one bell push, complete all as specified and as directed.
(f) One light point controlled by two, two-way switches, complete all as specified and as directed.
All as per item No. 3.00 above but with using 2.5 Sqmm single core multistanded copper conductor cable (FRLSH)and 2.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) for common earth wire for 6 pin 15 Amp socket outlet on board, complete all as specified and as directed.
All as per item No. 3.00 above but with 4 Sqmm single core multistanded copper conductor cable(FRLSH) and 4 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH)for common earth wire for 20 Amp socket outlet on independent board, complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) passing in PVC cassing-N-capping 25/32 mm dia fixed on surface of wall/roof/ceiling withexisting/new sunken pressed steel terminal boxes including 3.00 mm thick plastic laminated sheet top cover and 1.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed:- (a) One light point controlled by one, one way switch
(b) One fan point controlled by one way switch, complete all as specified and as directed.
(c) One socket outlet 3 pin 5/6 Amps on same board, complete all as specified and as directed.
(d) One socket outlet 3 pin 5/6 Amp on independent board, complete all as specified and as directed.
(e) One bell point controlled by one bell push, complete all as specified and as directed.
(f) One light point controlled by two, two-way switches, complete all as specified and as directed.
All as per item No. 11.00 above but with using 2.5 Sqmm single core multistanded copper conductor cable (FRLSH) including 2.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) for common earth wire for 6 pin 15 Amp socket outlet on independent board, complete all as specified and as directed.
M&L for concealed Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked), class V in concealed PVC conduit (ISI Marked) not less than 20 mm dia heavy duty with accessoriesetc and including sunken pressed steel terminal boxes in wall with 3.00 mm thick plastic laminated hylem sheet top cover and 1.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed. Note:- Rates of chasing/cutting & making goods shall be included in the unit rate:- (a) One light point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator, complete all as specified and as directed.
(c) One three pin 5 Amp socket on same board with other switches, complete all as specified and as directed.
(d) One three pin 5 Amp socket on independent board, complete all as specified and as directed.
(e) One bell point controlled by one bell push, complete all as specified and as directed.
(f) One light point controlled by two, two-way switches, complete all as specified and as directed.
All as per item No. 18.00 above but with 2.5 Sqmm single core multistanded copper conductor cable (FRLSH) and 2.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) for common earth wire for 6 pin 16 Amp socket outlet on independent board, complete all as specified and as directed.
All as per item No. 18.00 above but with 4 Sqmm single core multistanded copper conductor cable (FRLSH)and 4 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) for common earth wire for 20 Amp socket outlet on independent board, complete all as specified and as directed.
S&F switch piano flush type single pole one way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F switch piano flush type single pole one way 16 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F switch piano flush type single pole two way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F socket outlet 2 in 1, 5 pin, 6 Amp flush type, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F socket outlet 2 in 1, 6 pin, 6 and 16 Amp flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F bell push, piano flush type, 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F bell Ding Dong, AC 230 volts, single pole, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F LAmp holder with back plate suitable for batten fittings including, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F Ceiling rose, 3 terminal/ PVC/ Polycarbonate, isolated body, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F socket stepped type electonic fan regulator flush type, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
M&L for Point wiring for modular fittings complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) , class V in concealed PVC conduit (ISI Marked) not less than 20 mm dia heavy duty with accessories in surface of wall / roof / ceiling etc and including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed. Note:- rates of chasing/cutting & making goods shall be included in the unit rate:- (a) One light point point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator, complete all as specified and as directed.
(c) One three pin 6 Amp socket on same board with other switches, complete all as specified and as directed.
(d) One three pin 6 Amp socket on independent board, complete all as specified and as directed.
(e) One bell point controlled by one bell push, complete all as specified and as directed.
(f) One light point controlled by two, two-way switches, complete all as specified and as directed.
All as per item No 36.00 above but with 2.5 Sqmm single core multistanded copper conductor cable (FRLSH) and 2.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) for common earth wire for 6 pin 16 Amp socket outlet on independent board, complete all as specified and as directed.
All as per item No 36.00 above but with 4 Sqmm single core multistanded copper conductor cable (FRLSH) and 4 Sqmm PVC insulated unsheathed stranded copper conductor(FRLSH) for common earth wire for 20 Amp socket outlet on independent board, complete all as specified and as directed.
S&F Modular switch flush type single pole one way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F Modular switch flush type single pole one way 16 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F Modular socket outlet 2 in 1,5 pin 6 Amp flush type (ISI Markded), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F Modular socket outlet 2 in 1, 6 pin, 6 /16 Amp flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F power unit for upto 2 ton AC and geyser up to 3.5 KW modular type, 4 module,240 volts, complete all as specified and as directed by Engr-In-Charge. Make : Legrand Cat No. 675558 or equivalent in Schneider/ ABB
S&F Modular switch FT, SP, two way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F Modular bell push, flush type,6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F Socket stepped type Modular electonic fan regulator flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F in repair modular cover plate with frame 12 to 18 module type for fixing of modular switch socket, regulators, blank plates as per existing make etc., complete all as specified and as directed.
S&F in repair modular cover plate with frame 6 to 8 module type for fixing of modular switch socket, regulators, blank plates as per existing make etc., complete all as specified and as directed.
S&F in repair modular cover plate with frame upto 4 module type for fixing of modular switch socket, regulators, blank plates as per existing make etc., complete all as specified and as directed.
S&F prewired sheet metal enclosures 240 volt with suitable rated bus bar for double door 8way IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going, complete all as specified and as directed by Engr-in-charge. Make : Legrand/ Schneider/ ABB
S&F MCB Single pole "B" series 5-32 Amps (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F MCB Single pole & neutral "B" series 63. Amps (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F in repair sheet metal enclosure with plug socket single pole and neutral enclosure with two pin and earth plug complete with one MCB 20Amps SP, complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F LED tube light fittings 20W, 6500K rated, 240Volt with integrated driver and cable connector upto electrical terminal etc., complete all as specified and as directed. Make : Philips/ Havells/ Bajaj.
S&F LED tube light fittings 20W, 2700K rated, 240Volt with integrated driver and cable connector upto electrical terminal etc., complete all as specified and as directed. Make : Philips/ Havells/ Bajaj.
S&F decorative wall mounting SS finish fixture with opal glass diffusure suitable and including lamp thrid type, complete all as specified and as directed. Make : Philips/ Havells/ Bajaj.
S&F Security light fittings 25watt LED including stand and bracket with all accessories etc., complete all as specified and as directed by Engr-in-Charge. Make : Philips/ Havells/ Bajaj.
S&F Security light bracket made out of medium grade GI with all accessories and including fixing arrengment etc., complete all as specified and as directed.
S&F square shape surface mounted down light LED fittings 15/18 Watt complete with all accessories and including fixing arrengment etc., complete all as specified and as directed. Make : Philips/ Havells/ Bajaj.
S&F LED bulk head light10 watt complete with all accessories pre wired and including connecting up to fiting with flexible cable of suitable size, complete all as specified and as directed. Make : Philips/ Havells/ Bajaj.
S&F LED bed light 3/5 watt, COB type complete withelectronic driver and including connecting up to fiting with flexible cable of suitable size, complete all as specified and as directed. Make : Philips/ Havells/ Bajaj.
M&L in repairs sub main wiring with two runs of 6 Sqmm single core multistrandred copper conductor PVC insulated and unsheathed cable (FRLSH) passing through PVC Cassing-N-Capping of size 32mm (ISI Marked) (MMS) fixed on surface of wall/ceiling and making good the distrurbed surface of wall including 6 Sqmm single core copper conductor cable (FRLSH) PVC insulated and unsheathed cable as earth wire, complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm earth wire shall be measured as unit length.
M&L in repairs sub main wiring with two runs of 6 Sqmm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through Surface PVC conduit of size 20 mm (ISI Marked) (MMS)on wall/roof and making good the distrurbed surface of wall incl 6 Sqmm single core copper conductor cable PVC insulated and unsheathed cable as earth wire (FRLSH cable), complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm earth wire shall be measured as unit length.
M&L in repairs sub main wiring with Two runs of 6 Sqmm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through Concealed PVC conduit of size 20 mm (ISI Marked) (MMS) on wall/roof and making good the distrurbed surface of wall including 6 Sqmm single core copper conductor cable PVC insulated and unsheathed cable as earth wire (FRLSH cable), complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm earth wire shall be measured as unit length.
S&F in Replacement of distribution board manufacturer prewired , IP 42 in sheet metal enclosure when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 4 way, complete all as specified and as directed. Make : Legrand Cat No. SD 3809 or equivalentin ABB/ Schneider as approved by GE.
S&F in Replacement distribution board manufacturer prewired , IP 42 in sheet metal encl when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 8 way, complete all as specified and as directed. Make : Legrand Cat No. SD 3706 or equivalent in ABB/ Schneider as approved by GE.
S&F in Replacement distribution board manufacturer prewired , IP 42 in sheet metal encl when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 12 way, complete all as specified and as directed. Make:Legrand/ Schneider/ ABB
S&F in Replacement distribution board in sheet metal enclosure, DBs, IP 42, to be used with 200 Amps rated bus bar confirming to relevant IS TPN 4 way, complete all as specified and as directed. Make : Legrand Cat No. SD 3631 or equivalent in ABB/ Schneider as approved by GE.
S&F in repair MCB single pole 5 to 32 Amps, 'C' Curve (ISI Marked), 10 KA, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair SPN 40 Amps,'C' Curve (ISI Marked), 10 KA, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair SPN 63 Amps, 'C' Curve (ISI Marked), 10 KA, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair MCB TPN,415 volt, 63 Amps 'C' Curve (ISI Marked),16 KA, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair MCB 4 pole,415 volt, 100 Amps 'C' Curve (ISI Marked),16 KA, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair in existing MCCB,16 KA, 4 Pole, 63 Amps to 100 Amps, 'C' Series (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair in existing MCCB,16KA, 4 Pole, 100 Amps to 125 Amps, 'C' Series (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair switch piano flush type 5/6 Amp single pole one way 230 V, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair switch piano flush type 5/6 Amp single pole two way 230 V, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair switch piano flush type 15/16 Amp single pole one way 230 V, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair socket out let flush type 6 Amp 2/3 pin suitable for 5/6 Amp plug top 230 V, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair socket out let flush type 3/6 pin suitable for 15/16 Amp plug top multipurpose 230 V, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair lamp holder insulated body with back plate batten/angle type for batten fittings, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair bell push 6 Amps, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F in repair bell AC, 230 Volts, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F Ceiling rose, 3 terminal/ PVC/ polycarbonate, isolated body, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F stepped type electonic fan regulator flush type, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F repair Modular switch any type and make 6 Amp one way 230 V, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair Modular switch any type and make 16 Amp one way 230 V, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair Modular socket any type and make, 6 Amp 5 Pin one way 230 V, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair Modular socket Any Type and make, 16 Amp 5 Pin one way 230 V, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair Modular fan Regulator step type and make, 100 watt , 230 Volts, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair Modular bell push type and make, 100 watt, 230 Volts, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair Modular switch any type and make 6 Amp two way 230 Volts, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in repair modular cover plate with frame 8 to 18 module type for fixing of modular switch socket, regulators, blank plates etc., complete all as specified and as directed.
S&F in repair modular cover plate with frame upto 8 module type for fixing of modular switch socket, regulators, blank plates etc., complete all as specified and as directed.
S&F in repair modular cover plate with frame 4 module type for fixing of modular switch socket, regulators, blank plates etc., complete all as specified and as directed.
S&F in repair 3.00mm thick plastic laminated hylem sheet top cover of size 8" x10" etc., complete all as specified and as directed.
S&F in repair 3.00mm thick plastic laminated hylem sheet top cover of size 7" x5" etc., complete all as specified and as directed.
S&F of capacitor 2.5 m.f.d , 230 volts +-5%, complete all as specified and as directed. Make : Havells/ Crompton/ Bajaj
S&F repair PVC DB Box 2 way when MCB used, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 16Sqmm nominal cross sectional area, complete all as specified and as directed.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10Sqmm nominal cross sectional area, complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate no. 3 connected to earthing test point all as specified or indicated including testing on completion . Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc., complete all as specified and as directed.
Note :- (i) Contract Sum shall be arrived at after deduction of amount of Schudule of Credit.
Nvimal Engineers and Contractor
CHAHAR ENGINEERS AND COMPANY
LOKESH ELECTRICAL WORKS CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .