Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.1 Cr
EMD Value
₹6.3 L
Closing Date
2 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTEC
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years,ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange,incorporated /registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Any RI or El or ABS or IBS/IBH work involving Indoor & Outdoor work (Cable laying & termination).Note 1 -Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40 or 60% (as the case may be) criteria of similar nature of workNote 2:a. Submission of 'Undertaking by the tenderer' that the equipment for EI or Axle Counter or AFTC or UFSBI shall be procured from RDSO approved sources and installation, testing and commissioning of EI or Axle Counter or AFTC or UFSBI shall also be got done from the same source including after sales support required during the warranty period.ANDb. After the award of the contract, MOU with RDSO approved source covering supply of equipment for EI or Axle Counter or AFTC or UFSBI. Installation, testing & commissioning of EI or Axle Counter or AFTC or UFSBI by the same RDSO approved source including after sales support required during the warranty period before supply of equipments is undertaken. For Electronic Interlocking (EI) equipments, 'The successful bidder shall submit an undertaking from RDSO approved EI OEM, before the supply of material, to confirm compliance with extent RDSO guidelines and to meet contract specific requirements'.
20 conditions · 12 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Covering letter duly filled by the tenderer to be submitted on their letter head as per Annexure-I of Tender Document.
A copy of Authorization/Power of Attorney issued by the sole proprietor/partnership firm/LLP/ Society/JV/Company in favour of the individual to sign the tender on behalf of the sole proprietor/partnership firm/LLP/Society/JV/company as per clause no. 14 part -l of Tender Document. In case of company power of attorney must be backed by the resolution of Board of Directors and create liability against the company.
Details of Plant and Machinery already available with the firm must be uploaded.
List of engineers/personnel already available/ proposed to be employed for deployment on this work must be uploaded
Details of Beneficiary for Electronic Transfer of Funds must be uploaded as per Annexure-XII of STD-2022
An undertaking by sole proprietor firm/all partners of the partnership firm/Power of attorney holder if company (as per Annexure-B/C uploaded with Tender Document )or LLP or Society/JV that he/they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 (Part-II) of the General Conditions of Contract (as per Annexure-B/C uploaded with Tender Document). (Detail instructions/condition may be seen on Tender Document)
Please submit the copy of the registration certificate of firm, PAN, GSTIN (if applicable) etc.
Tenderers are compulsorily required to upload undertaking (attached as Annexure-A uploaded with Tender Document) regarding Employment /Partnership of Retired Railway Employees attached as Annexure 'A'. Otherwise the tenderer will give full information as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. Note:- Tenders without undertaking or required information shall be summarily REJECTED.
The tenderer shall clearly specify whether the tender is submitted on his own or on behalf of a partnership firm/Company/Joint Venture (JV) /Registered Society/ Registered Trust/HUF etc. The Tenderer (s) who is/ are constituents of firm, company, Association or Society shall enclose self-attested copies of the constitution of their concern, Partnership Deed, copy of PAN Card and Power of Attorney along with their tender. Tender Documents in such cases shall to be signed by such persons as may be legally competent to sign them on behalf of the firm, Company, Association, Trust or Society, as the case may be. Following documents shall be submitted by the tenderer: (a)Sole proprietor Firm: (i) Affidavit of sole proprietorship firm. (ii) All documents in terms of explanatory notes in clause 14.0 PART-I of Tender Document (b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of explanatory notes in clause 14.0 PART-I of Tender Document. (c) Partnership firm, as per Tender Form-2 (Annexure-I) Para 14.10 PART-I of Tender Document: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) All other documents in terms of TENDER FORM -2 of Tender Document (d) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company. (ii) A copy of Certificate of Incorporation. (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms of explanatory notes in clause 14 PART-I of Tender Document (e) Limited Liability Society: (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation of LLP. (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender/MoU/JV on behalf of the LLP and create liability against the LLP. (iv) All other documents in terms of explanatory notes in clause 14 PART-I of Tender Document (f) Registered Society & Registered Trust: (i) A copy of the Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society. (v) All other documents in terms of explanatory notes in clause 14 PART-I of Tender Document (g) Joint Venture: All documents as specified under Para 14 PART-I of Tender Document.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suomoto post tender letters of the tenders shall be treated as NULL & Void as per Para 4.6 of STD- 2022
This tender will govern under "Indian Railway Standard General Condition of contract - 2022 or latest. Tenderers are requested to read GCC and tender document very carefully before submitting their Bid.
Performance Guarantee- The successful bidder shall submit PG as per procedure Mentioned in clause 5.1A of Northern Railway standard Tender Document 2022, The successful bidder shall submit the performance Guarantee(PG) amounting to 5% of the contract value for all the tenders issued
The tenderer shall submit along with the tender document, documents in support of his/their claim to fulfill the eligibility criteria as mentioned in the tender document. Each page of the copy of documents/certificates in support of credentials, submitted by the tenderer, shall be self-attested/digitally signed by the tenderer or authorized representative of the tendering firm. Self attestation shall include signature, stamp and date (on each page). Only those documents which are declared explicitly by the tenderer as "documents supporting the claim of qualifying the laid down eligibility criteria", will be considered for evaluating his/their tender
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
Undertakings by Partnership Firm- In case the Letter of Acceptance (LOA) is issued to a partnership firm, the undertakings as per clause 18.10 of Annexure -VIII of Northern Railway Standard Tender Document 2022 shall be furnished by all the partners through a notarized affidavit, before signing of contract agreement.
As per Railway board letter No. 2018/CE-1/CT/4 dt. 17.10.2018 contractor shall mandatorily update the labour data on Railway Sharmik kalyan portal on monthly basis. The detailed guidelines are given in Clause 5.4 of PART-I of Standard Tender Document- 2022.
Hakimpur Converting line No. 5 in to common loop line & setting up of new Railway Goods Shed at Hakimpur Railway Station
SNT-Sig-EI-HKP-Umbrella~NR
SNT-Sig-EI-HKP-Umbrella
Open
Works - General
12 Months
Moradabad, Uttar Pradesh
₹0
₹6.3 L
9 Oct 2026
9 Oct 2026
19 Oct 2026
235 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,14,82,623.89 | ||
| — | 1.00 | — | — | ||
| Design, Fabricate, supply, installation, wiring, testing and commissioning of Distributed EI system for station HKP station.Inspection Authority: Supply: RDSO, Installation & Wiring: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,26,99,804.99 | |
| — | 1.00 | — | — | ||
| Supply of "As built" documents (i) Technician / Jr. Engineer (Installation and Maintenance Level) - Manual for Installation, Testing, Commissioning and Maintenance of the System (6 Sets for each EI). (ii) Engineer Level - Technical & System Module for diagnostic & Trouble shooting for Repair centre (6 Sets for each EI). (iii) Higher Management Level - Functioning and System Over View (6 Sets for each EI). (iv) Completion Documents as per special condition of Contract (6 Sets for each EI). (v) Supply of documents as per Technical specification Para - 10.2 of RDSO Specification no RDSO/SPN/192/2019 ver.2 (6 Sets for each EI).Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document( unit read Set per Station) | — | — | — | 84,096.96 | |
| — | 1.00 | — | — | ||
| "Supply of Instruments / Tool Kits suitable for EI commissioned:* Tool kit & Measuring Instruments for technicians / Jr. Engineers for Testing, Maintenance, Trouble Shooting and repair at site.Note: Details of tool kit item is enclosed in Annexure -V/Vol.II of tender document.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document"( unit read Set per Station) | — | — | — | 1,39,222.21 | |
| — | 1.00 | — | — | ||
| Installation, testing & commissioning of EI equipments supplied as per item no.1, including transportation from consignee depot to site at stations listed above. Installation is to be done as per RDSO specification 192/2019 and RDSO practice circulated vide TAN no. STS/E/TAN/3012, Ver. 2.0, Dt.10.08.2016, TAN no. STS/E/TAN/3007, Ver. 1.0, Dt.02.11.2012 for industrial grade PC and TAN no. STS/E/TAN/3006, Ver. 1.0, dt. 02.11.2012 for earthing and bonding scheme for Electronic Interlocking. (1 Job=1Station)Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 3,98,975.17 | |
| — | 1.00 | — | — | ||
| Earthing of SSI/EI equipment, Relay racks and Power Equipment etc. to be done along with supply of all requisite materials as per Signal Engineering practice . As per RDSO TAN no. STS/E/TAN/3006, Ver.3.0, Dt. 08/01/2025 or latest. The earthing arrangement shall be as per RDSO/SPN/197 Ver. 1.0 or latestInspection Authority: Supply: RDSO, Installation: Site Engineer, (Installation to be done by OEM) Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 5,30,488.05 | |
| — | 2.00 | — | — | ||
| Training for Rly. Tech./JE/SE/SSE by OEM in installation, testing & commissioning, maintenance & trouble shooting of EI system complete including supply of hard/soft copies of course module for each trainee. Competency certificate to trainee to be issued by OEM. All arrangements including classroom, lab, equipment, measuring instruments etc. required for the training should be satisfactorily arranged by the contractor at their own cost.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,541.2 | |
| — | 2.00 | — | — | ||
| Training for Rly. Officers by OEM in installation, testing & commissioning of EI system complete including supply of hard/soft copies of course module for each trainee. All arrangements including classroom, lab, equipment, measuring instruments etc. required for the training should be satisfactorily arranged by the contractor at their own cost.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 2,001.92 | |
| — | 5.00 | — | — | ||
| Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4.1/97A made of angel iron size 45mmx45mmx6mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,05,699.2 | |
| — | 50.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding / cable careers made of angle iron size (35mmx35mmx5mm) and flat of size (25mmx3mm) as per the instructions of engineer at site. The space between two flats will be 25cm or less as per the site requirements. All the fixing materials i.e. bolts, nuts, washers, insulators, cement, concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting with ISI mark paints.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 25,353 | |
| — | 30.00 | — | — | ||
| Supply, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1"x1" wooden batton fitted all around on the rear as per instruction of Engineer at site. All the materials to be supplied by contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 76,229.1 | |
| — | 75.00 | — | — | ||
| Supply & laying of anti-static PVC flooring with adhesive (in 2.00mm thickness) (Relay room/equipment room/Data logger room/Axlecounter room, MT Room).Inspection Authority: Supply: Consignee, Laying: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,03,080.75 | |
| — | 1000.00 | — | — | ||
| Supply of electric fuse complete with fuse block(base) for Railway signalling non- detoriorating type low voltage fuse assembly 2Amp/4Amp/16Amp.(As per requirement) to suit RDSO Specn. No.IRS: S-78/92 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev-2) and drg no. 23748 (Alt.4) or latest. Fuse block shall be suitable for round head type fuses.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 2,06,060 | |
| — | 1.00 | — | — | ||
| Fabrication, supply, installation and wiring of power supply board in IPS room/ relay hut/ relay room as per drawing no. SSTE/PS/1237 dt. 26.02.92 and extension of the power supplies from IPS to power supply board and from power supply board upto the MDF board. This includes fixing of ARA terminals, fuse bases, switches etc. and termination of power wire/ cables. This includes supply of all wiring & termination materials except terminals & fuses, power & U/G cable/wires. Wherever outdoor U/G cables are to be laid that is covered separately.Inspection Authority: Supply: Consignee, Installation & Wiring: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 16,562.94 | |
| — | 12.00 | — | — | ||
| Supply fixing and wiring of Fuse Auto Changeover System (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor.Inspection Authority: Supply: RDSO, Installation: Site Engineer (OEM PCCL) Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,73,061.12 | |
| — | Breakup | for details. | — | ||
| Supply of power wires IS2465/1984 & IS 694/1990 or latest & As per IRS Spec No. 76/89(Amd.3 ) or latest of the following sizes :- | — | — | — | 6,37,865.82 | |
| — | 1.00 | — | — | ||
| "Prep. of cable route plan, Cable core chart, Power supply arrangement plan for indoor and out door , Cable termination chart in relay room and location boxes, Location wiring plan, Cable insulation chart and register, Track circuit history card, Fuse analysis plan , Equipment disposition plan, Track circuit jumpering plan, Terminal and Contact analysis chart , Outdoor circuits,pull sheets,gomettie plans,diagrams. temp. plans required for execution of PNI/NI and other outdoor diagram and obtaining approval of the engineer as per following :-(i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software back up of complete set in the form of CDs. (iii) One complete set of tracings.(iv) Design through CAD(v) Drawings in A3 & plans in bigger size. (six sets). Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document" | — | — | — | 47,411.77 | |
| — | 8000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.NR/S&T/CON/1. 1/97-A so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of rooots of trees & bushes. Lesser/Deeper depth of the trench is to be paid proportionately.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 6,11,200 | |
| Supply and laying of 2nd class bricks in the trench and laying as per drg. No.NR/S&T/CON/1. 1/97A as per instructions of the site Engineer.Inspection Authority: Supply: Consignee, Laying: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,08,000 | |
| — | 1900.00 | — | — | ||
| Boring & Trenchless cabling along with supply & insertion of self lubricated HDPE pipe as per IS 4984:2016 of 110 mm outer dia with 6mm wall thickness in the bore for laying of Signalling / Telecom /Power cable under track/road/culvert at the depth of 1.5mtrs etc.cable laying covered seperately.Inspection Authority: Supply: RITES, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 28,48,936 | |
| Laying of signalling/Telecom/power cables of different sizes as per drg. No. NR/S&T/CON/1. 1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 6,70,500 | |
| — | 5200.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable seperately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 77,272 | |
| — | 20.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Cases (Single) as per drg. No.(NR/S&T/D&D/02/2024). All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railway. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,20,223.2 | |
| — | 10.00 | — | — | ||
| Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 2,14,285 | |
| — | Breakup | for details. | — | ||
| Preparation & fixing of bakelite hylum sheet 910x800x6mm and teak wooden shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal shelf type Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type fuses with bases,catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. | — | — | — | 1,11,543.9 | |
| — | 1.00 | — | — | ||
| Supply & installation of annunciator 10 lines as per RDSO spec.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 9,771.78 | |
| — | 20.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of half app.cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2. 8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement,coarse sand,aggregate and anchor bolt shall be supplied by contractor . App. Case half will be supplied by Railway. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 81,578.6 | |
| — | 4.00 | — | — | ||
| Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 with Alt.B and 221/82 with Alt.B.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 58,908 | |
| — | Breakup | for details. | — | ||
| Preparation and fixing of bakelite hylum sheet 450x800x6mm and teak wooden shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal, shelf type Q series relays and other type of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type fuses with bases,catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays,ARA terminals only shall be supplied by the Railways. | — | — | — | 77,193.4 | |
| — | 8000.00 | — | — | ||
| Supply of Terminal Block 25MM center M-6 terminal made of PBT to RDSO Drg.no.SA23471 A (Alt-4) or latest as per RDSO specn. IRS-S-75/2006 (Rev 2) or latest.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 5,76,960 | |
| — | 1.00 | — | — | ||
| Casting, concreting and curing of foundation for main signal of size (1041mmx1041mm)at bottom and (711mmx711mm) at top and 1750mm deep as per Drg. no. NR/S&T/CON/2. 1/97 all material such as anchor bolts, cement, coarse sand aggregate to be supplied by contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 9,248.38 | |
| — | 1.00 | — | — | ||
| Supply of colour light signal post with ladder & bases as per tech. spec. IRS-S-6-81 or latest of the following size :-Colour light signal post 3.6m and ladder 3.5M for all other signals except main line str. & home signal,Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 18,710.42 | |
| — | 1.00 | — | — | ||
| Supply of colour light signal unit complete with out signal transformer as per RDSO Specification no. IRS:S-26/64 or latest. Tech.specn. of the following type :-2 Aspect colour light signal unit.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 18,279.97 | |
| — | 1.00 | — | — | ||
| Supply of route indicator complete with hoods & offset bracket 5 1/2" as per RDSO specn.no.IRS-S-66/84 (Amd-1) or latest as per latest drawing.of the following type :-3/45/6-way route indicator junction type as per drg. No. SA-23403 (adv.) or latest. ,Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 36,314.55 | |
| — | Breakup | for details. | — | ||
| "Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required.This includes provn. Of wooden (Sal) cross arm 1 mtr x 1 mtr. for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways published by Govt. of India and approved drawings.All items for the above work shall be supplied by the contractor (except the items which are covered separately elsewhere in the schedule) including but not limited to the following items.(i) "U" bolt for offset brackets.(ii) Wooden cross arm 1 mtr. x 1 mtr.(iii) MS angle and MS sheet for blanking of ladder.(iv) Wire mesh guard, lock for unit if required, nuts and bolts etc. for the following :" | — | — | — | 7,703.5 | |
| — | 2.00 | — | — | ||
| Supply and fixing of P/G/C/IB marker with complete fitting as per Drg No NR/S&T/Con/6.2/97. All materials required for the job such as MS sheet, MS angle, nuts and bolts paints and painting material will be supplied by the contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,366.66 | |
| — | 1.00 | — | — | ||
| Supply of shunt signal position light with lock, unit offset bracket 3.5" dia. without holders bulbs etc. to drg.no.23840 adv.specs.no.IRS-S-23/88 Dependent post type.,Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 9,851.81 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of LED lit calling-on/shunt signal on the same post below main signal on offset bracket. Which also includes fixing of stencil and hoods, wiring and focussing of the signal. Offset brackets, calling on signal/shunt signal complete will be supplied by Railways (Supply of calling on signal is covered seperately, elsewhere in the schedule). U-bolt for offset bracket and wire and wiring material will be supplied by contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,058.05 | |
| — | 500.00 | — | — | ||
| Supply, fixing and wiring of PPTC Fuses 2/6A make tyco/ Raychem/ Bourn/ Fuzetech/ Little Fuse or similar.Inspection Authority: Supply: Consignee, Installation & Wiring: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,010 | |
| — | 30.00 | — | — | ||
| Conventional earth :- Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatement shall be done as per std. pratice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earhting connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. ( NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor.Inspection Authority: Supply: Consignee, Installation & Wiring: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 76,438.5 | |
| — | 1.00 | — | — | ||
| Supply, Installation,Testing &Commissioning of Microprocessor based Networkable analog addressable and modular type of fire Alarm Control Panel with display with 2 loop expandable upto four loop ,power supply and battery back up as per RDSO specification no. RDSO/SPN/217/2025 Ver 3.1 or latest. Including GSM module-01 No. for sending SMS to configured mobile number and relay module -02 Nos. for connecting to datalogger for remote monitoring . The panel should support sufficient devices of both detectors and modules in a single line circuit .Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 75,038.94 | |
| — | 30.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Addressable heat and smoke Multi sensor. As per RDSO specification No. RDSO/SPN/217/2025 Ver 3.1 or latestInspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 60,549 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point with inbuilt short circuit fault isolator (as per RDSO/SPN/217/2025 Ver 3.1 or latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 6,054.52 | |
| — | 2.00 | — | — | ||
| Supply, Installation,Testing & Commissioning of Hooter cum Strobe including its control module As per RDSO specification No RDSO/SPN/217/2025 Ver 3.1 or latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 8,488.14 | |
| — | 50.00 | — | — | ||
| "Supply, Installation, Testing & Commissioning of Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 35,239.5 | |
| — | 1.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver. 3.0 or latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 43,167.27 | |
| — | 1.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Aspiration systems with single pipe slot along with required module and power supply interfacing module etc as per RDSO specification no RDSO/SPN/217/2021 Ver 3.0 or latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,65,388.08 | |
| — | 35.00 | — | — | ||
| Supply, Installation, Testing & Commissioning CPVC Pipe and all other associated fittings as per RDSO/SPN/217/2018 Ver 3.0 or latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 28,863.8 | |
| — | 200.00 | — | — | ||
| Supply of Fire Survival cable 2C X1.5 Sqmm (Meters) unarmoured, (As per RDSO Specification No. RDSO/SPN/217/2018 ver2.0 or Latest.Inspection Authority: Supply: RDSO, Installation, Testing & Commissioning: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 23,884 | |
| — | 2200.00 | — | — | ||
| Supply of PVC ConduitPipe of 25 mm dia ISImarked heavy (HMS)series as per IS: 9537part-III - 1983 standardsor latest.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 50,204 | |
| — | 2200.00 | — | — | ||
| Laying & Fixing of conduit 25mm (conduit Pipe must be fixed with clamp at the interval of 300mm)/HDPE/GI/RCC PipeInspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 43,406 | |
| — | 4.00 | — | — | ||
| Supply of ISI marked Carbon di Oxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS: 2878 from seamless cylinder confirming to IS: 7285 with IS marked control value conforming to IS: 3224 high pressure myr. Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer. Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 41,420.28 | |
| — | 1.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6 scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 3,014.75 | |
| — | 1.00 | — | — | ||
| "Supply of SM/SI/ESM furniture of Godrej or similar make consisting of the following:- 1. Executive revolving bearing series low back floating chair with normal arms cushioned chair:1 no.2. Executive table size 72""x36""x30"" with 3 drawers one side, Lockers cabinet on other side:1 no. 3. Visitors chair seat & back cushion with high density foam with plastic PVC handle capsul type flat pipe duly painted black: 3 Nos.4. Almirah steel with locking arrangement size 1277mmx765mmx440mm=1no.Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document" | — | — | — | 37,867.94 | |
| — | 3.00 | — | — | ||
| Supply of cable/wire indoor copper conductor single/multi core plain annealed high conductivity PVC insulated unamoured as per Spec. no. IRS-S/76/89 (Amd 3) or latest amendment of the following sizes :-Wire 16x0.2mmInspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 24,863.79 | |
| — | 2.00 | — | — | ||
| Supply, Installation & Commissioning of Computer (Main Operating Console) with 55" or more VDU LED type industrial grade PC WITH LASER PRINTER suitable for printing paper size A-4 and UPS with sufficient power backup.(minimum 4 hrs) along with work station and revolving chair. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 15,06,104.36 | |
| — | 1.00 | — | — | ||
| Supply, Installation & Commissioning of Computer (Maintenance Console) with 47" or more VDU LED type industrial grade PC with laser printer suitable for printing paper size A-3 and UPS/inverter with sufficient power backup.(minimum 4 hrs) along with work station and revolving chair Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 6,43,171.04 | |
| — | 98.00 | — | — | ||
| Q series relays with base (All type relays Q - series relays QN1 12F.4B Relays ).Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 8,48,196.86 | |
| — | 77.00 | — | — | ||
| Q series relays with base (All type relays Q - series relays QNA1 12F.4B Relays ).Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 6,66,440.39 | |
| — | 41.00 | — | — | ||
| Q series relays with base (All type relays Q - series relays QSPA1 Relays) .Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 3,58,553.2 | |
| — | 51.00 | — | — | ||
| Q series relays with base (All type relays Q - series relays QECX 61(ECR) Relays).Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,46,459.1 | |
| — | 30.00 | — | — | ||
| Q series relays with base (All type relays Q - series relays QBCA1 Relays.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 2,59,652.1 | |
| — | 36.00 | — | — | ||
| DC-DC Converter for EIInspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 9,69,391.44 | |
| — | 1.00 | — | — | ||
| "Supply of single spike air terminals of 17.2 mm dia. & 2000 mm length as required and as per site conditions. The air terminal shall be manufactured with Copper Bonded Steel & shall be as per IEC 62561-2. The air terminal shall be fixed with concrete base arrangement.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 5,000 | |
| — | 28.00 | — | — | ||
| Down Conductor. (i)Supply of 8 mm dia Copper Bonded Steel round conductor (250Micron) for Down conductors to be installed on vertical wall, facade of masonary / glass /metalic work. It shall meet the requirements of IEC 62561-2.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 9,450 | |
| — | 20.00 | — | — | ||
| "Supply of Down Conductor holder for holding of 8 mm dia. round conductor (for RCC wall). The conductor holder shall be of Stainless steel which is mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 6,000 | |
| — | 2.00 | — | — | ||
| Down Conductor. (iii)Supply of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value which shall be of Stainless steel and suitable for connecting 8 mm aluminium round conductor to 25x2mm Copper conductor (with enclosure). It shall meet the requirements of IEC 62561-2.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,000 | |
| — | 1.00 | — | — | ||
| Supply of Digital Lightning Strike counter for counting the number of lightning strikes and has a 3 Digit display facility and also records date and time . The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 67 rated enclosure suitable for external application. It shall meet the requirements of IEC 62561-6Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 15,000 | |
| — | 4.00 | — | — | ||
| Supply installation of 2DT Exothermic joint Between 25 x 2mm Horizontally laid Copper Strip to 25 x 2mm Horizontally laid Copper Strip with UL Tested.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 2,800 | |
| — | 1.00 | — | — | ||
| "Supply & Installation of Isolating spark Gap for lightningequipotential bonding of different earth grids according to IEC62561 part-3 at 100kA impulse current, IP 68, fire retardant enclosure.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document" | — | — | — | 21,500 | |
| — | 1.00 | — | — | ||
| Installation of Class A device on the top of the building. The device shall be installed at a height of about 3 mtrs. from the roof of the building using a GI mast. The device shall be connected to the Earth pit using the down conductor or similar. This down conductor shall be run firmly along the side of the mast with the help of the spacers. It shall also be ensured that this down conductor shall not touch the building throughout. The down conductor shall be connected to the earth Electrode using Exothermic Welding. A counter shall be installed at an appropriate place to count the number of occurrences. All the accessories like spacers, welding materials etc. required for the installation shall be arranged by the contractor only Inspection Authority: Site Engineer. Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 10,605.24 | |
| — | 50.00 | — | — | ||
| Supply of 25mm x 2 mm bare copper strips in the equipment room.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 62,987.5 | |
| — | 50.00 | — | — | ||
| Routing and termination of 25x2mm Copper tape/8 mm solid copper round conductor which is to be fixed inside the equipment room with 60mm, 6KVA insulation studs including supply of insulation studs. The separation of the two successive insulation stud should be 600mm apart. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,587 | |
| — | 4.00 | — | — | ||
| Supply of tag blocks with PVC cover conforming to drg. no. SA-24751 or latest and as per IRS-S-77/2006(Rev.) or latest for the following size:-200 way tag blocks.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 5,966.56 | |
| — | 4.00 | — | — | ||
| Fixing, wiring & soldering of tag blocks with PVC cover on cable termination rack/relay rack/block rack/HV rack as per Drg.No. NR/S&T/CON/4.3 /97A. All fixing material like flats, bolts, nuts, washers, plastic tag block cover for the tag block etc. will be supplied by the contractor.200way tag blocks.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 669.92 | |
| — | Breakup | for details. | — | ||
| Supply of disconnect terminal Wago or similar as per spec. no.RDSO/SPN/189/2004 Ver 3.0 or latest as below: | — | — | — | 5,56,492 | |
| — | 1.00 | — | — | ||
| Installation & wiring of SMPS based Integrated Power Supply system for station as per . spec no. RDSO/SPN/165/2012 (Ver.3) or latest as per guide lines. All materials for installation shall be supplied by contractor. Transportation of IPS from Railway store to site shall be done by contractor. Power supply (DG set with fuel)for charging of Batteries shall be arranged by contractor. Charging of batteries, testing & commissioning as pre commissioning check list shall be done by OEM. Fabrication, Supply, installation and wiring of Power Supply Board for IPS Room/ Relay Hut/ Relay Room as per approved drg. SSTE/PS/1237 Dt. 26.02.92 and extension of the power supplies from IPS to power supply board and power supply board up to MDF board. This includes fixing of ARA terminal, fuses, wire cable , switches. Wherever outdoor U/G cable is to be laid, same shall be covered separatelyInspection Authority: Site Engineer, OEM PCCL to be submitted Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 62,365.3 | |
| — | 7.00 | — | — | ||
| Supply of magneto telephone with all accessories as per IRS-TC-36/97 (Amd 2) or latest.,Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 34,076.07 | |
| — | 7.00 | — | — | ||
| Fixing & wiring of magneto telephones with all accessories including Standard battery box and 3 nos. Of RR cells in the ASM office with crank handle locations/ K-points and interlocked L- xing gates as per instructions of the site Engr. All fixing materials including Standard battery box and 3 nos. Of RR cells to be supplied by the contractor.Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 4,171.3 | |
| — | 10.00 | — | — | ||
| Supply and instalation of VF Tapping & Termination Transformers 1120:470 Ohm as per IRS-TC-22/76 with Amd 1 with latest amendments.Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 21,961.1 | |
| — | Breakup | for details. | — | ||
| Supply and installation of DP boxes & termination of cables as per specifications, drawing and stipulations of tender documents. This includes fixing of the same on 1" thick board of size as per directions of site engineer with grouted nuts and bolts of suitable size and pipe fixed with clamps on pole/wall. All materials required for fixing & termination including salwood / hylum board and the hardware required for fixing will be supplied by contractor. | — | — | — | 11,122.06 | |
| — | 1.00 | — | — | ||
| Installation of Master VHF set 25W on ASM's table and wiring of the same with power supply wiring with 120AH VRLA batt. The 230VAC from IPS to be extended to the Power supply unit of the VHF & provision of power socket. This includes foundation (500x500x1000mm) and erection of the 50mm GI pipe on roof top and fixing of Antenna with GI pipe & wiring from Antenna to the VHF set with provision of guy wires for support of the GI pipe. All the materials cement, sand, GI pipe, guy wires, power wire with socket etc. except the VHF set, Antenna & 120AH VRLA batt. to be supplied by the contractor.Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 7,228.76 | |
| — | 4.00 | — | — | ||
| Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signalling system, releasing the cable coils to give access for shifting/ turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly re- connected. ( All materials required for the work shall shall be supplied by the contractor).Shifting of apparatus case (full) Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 18,027.6 | |
| — | 10.00 | — | — | ||
| Supply & Installation of Thermo shrink jointing kit for 6-Quad cable for straight through joints as per IRS: TC-77/2010 (Rev.2) with latest amendments. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 62,174.6 | |
| — | 1.00 | — | — | ||
| Cleaning, scraping, painting & lettering of all newly installed & existing gears such as signls, point equipment, track circuit equipment with TC No. on rail, app. cases, JB, TLJB, point rodding, cranks, compensators etc. including gate equipment if existing in station section as per the provision of IRSEM All paints (ISI marked) with IS specification No. IS:15489:2004 Ashian /Burger/ Nerolac or similar make. shall be approved by Railway Engr.and painting materials to be supplid by the contractor. Inspection Authority: Consignee for supply items (Paint etc) and Site Engineer for execution of schedule item. Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 20,608.45 | |
| — | 1000.00 | — | — | ||
| Supply of OFC single mode 6 Fibre armoured cable as per clause 5.15.12 of RDSO/SPN/TC/65/2009 or latest. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 30,160 | |
| — | 600.00 | — | — | ||
| Supply of STP (Shielded twisted paired) CAT-6 Cable as per Technical specification. Inspection Authority: Consignee. Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 14,412 | |
| — | 2000.00 | — | — | ||
| "Supply of HDPE Pipe of 40 mm dia as per RDSO spec.RDSO/SPN/TC/45/ 2013, Rev. 2.0 Amendment-1 & amendment-2 or latest with end cap provided with each drum. Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document" | — | — | — | 1,20,060 | |
| — | 2000.00 | — | — | ||
| Laying of HDPE duct in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylon rope through it at different places as per direction of engineer in charge or site engineer Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 13,200 | |
| — | 2000.00 | — | — | ||
| Drawing / Blowing of Optical Fiber Cable in PLB HDPE Duct. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 23,220 | |
| — | 10.00 | — | — | ||
| Supply Installation and commissioning of maintenance free earthing system which consists of supply of earthing kit-1 set consisting of (1) Earth Electrodes of copper clad steel alloy of 10 feet (3mts) long, 17mm dia and copper thickness of 250 microns- 1Nos. (II) RDSO approved Earth enhancing compound in 30 kg. Pack - 01 Nos. (III) Copper tape of 25mm x 6mm x 300mm with 99% purity - 02 Nos. and another of 25 mm x 6mm x 150mm to terminate on earth electrode. The earthing material shall be supplied as per RDSO specification RDSO/SPN/197/2008 or latest. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,30,918.1 | |
| — | 8.00 | — | — | ||
| Supply of Full HD Fixed bullettype/Dome type IP colour camera along with suitable housing,mounting arrangements and all accessories required for fixing and as per RDSO SpecificationNo.RDSO/SPN/TC/65/2021, Rev6.0or latest. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,07,866.4 | |
| — | 8.00 | — | — | ||
| Installation, Testing & Commissioning of Full HD Bullet/Dome IP Colour camera along with the mount as per RDSO SpecificationNo.RDSO/SPN/TC/65/2021, Rev6.0 or latest.All the accessories and fixing materials including mount required for this installation are to be supplied by contractor within the same cost. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,714.96 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing, wiring& commissioning of Full HD Resolution Large Format Display LED Monitor Screen Size 55"(inches) or larger as per RDSOSpecification NoRDSO/SPN/TC/65/2021 Version 6.0or latest. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,29,745.32 | |
| — | 1.00 | — | — | ||
| Supply and Installation of 32 Channel 4K NVR with 4 HDD NVR supported of 10TB.Specification as per.RDSO/SPN/TC/65/2021Version 6.0 or Latest Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 32,985.24 | |
| — | 2.00 | — | — | ||
| Supply and installation of 8 TB surveillance Hard Disk(internal) used for NVR Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 27,571.46 | |
| — | 1.00 | — | — | ||
| Supply, Installation, testing, wiring& commissioning of PC Work station hardware as per clause No 11.0 fords Specification No RDSO/SPN/TC/65/2021 Version 6.0or latest. For viewing monitoring and system management with digital keyboard and loaded with GUI client software feature as per clause no18. 2.0 of RDSO/SPN/TC/65/2021Version 6.0 or latest. Software licenses conditions as per clause No20.0 of RDSO/SPN/TC/65/2021Version 6.0 or latest. Inspection Authority: Supply: RDSO, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 2,08,940.83 | |
| — | 4.00 | — | — | ||
| Supply of Smart Managed 8 Port POE switch supports 1Gbps or more speed with 2 SFP Uplink Ports. RDSO Specs. No RDSO/SPN/TC/65/ 2021 Ver.6.0 with Latest amendments and versions. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 37,969.24 | |
| — | 12.00 | — | — | ||
| Supply , installation and commissioning of SFP module 10/100/1000 mbps compitable with switch single mode 1310/1550 Fiber module single fibre with suitable patch cord Inspection by Consignee Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 25,584.6 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of Media Converter fiber fiberto Ethernet 100 base T Signal modifier with all required accessories fiber including AC 230 V to DC Power adapter, as per Clause No. 16 of RDSO Spec. RDSO/SPN/TC/65/2016 (Rev.4.0) or latest Inspection Authority: Supply: RDSO, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 25,196.04 | |
| — | 2000.00 | — | — | ||
| Supply of 3 Core x 2.5 Sq mm multistrand copper conductor, PVC insulated, armoured power cable confirming to IS:1554 part I as per RDSO specification No. RDSO/SPN/TC/65/2021 rev 6.0orlatest).Finolex/polycab/orbit/havellor Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 1,51,360 | |
| — | 1.00 | — | — | ||
| Supply, Installation, testing & commissioning of UPS (online) 3 KVA. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 70,964.35 | |
| — | 1.00 | — | — | ||
| Supply and installation of 19" 42U Rack with all accessories like Electrical fitting,Fan tray, Patch Panel, cable manager,SPD for housing IP storage unit Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 35,306.45 | |
| — | 4.00 | — | — | ||
| Supply and installation of 9U Rack Enclosures Networking/Server Rack Brand accepted make Diga or similar or better. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 26,230.76 | |
| — | 500.00 | — | — | ||
| "Excavation of cable trenchat platform/concretedsurface of 120 mm wide &300 mm deep with marblecutting machine as perapproved cable plan atplace where cess formationwidth does not allow,standard width/depth oftrench to be dug for safetyreason .Restoring surfaceto normal condition asprior to trenching requiredmaterial will be supplied bythe contractor according toexcavated surface. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document" | — | — | — | 86,060 | |
| — | 4.00 | — | — | ||
| Supply of 6U Outdoor cabinateenclosure IP66 complied pole mount similar to Rackom 6UIP66 or similar. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 36,431 | |
| — | 1.00 | — | — | ||
| Preparation of drawing mentioning the location of cameras wiringdiadrams showing clearly the STPCAT-6, OFC, Power cable OTDR testreports of OFC cable, earthresistance test reports, technicaldetails of servers, switches, workstations, media convertors, storagesand submission in soft as well 3sets in printed to the consignee. Adiagram of camera location either inpictorial view or in descriptivemanner as decided by the officer incharge should be prepared on asuitable sheet and displayed in RPFCCTV control room. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 21,430 | |
| — | 3000.00 | — | — | ||
| Laying of OFC Cable/STP Cable/Power Cable in conduit pipe/pvc channel Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 29,940 | |
| — | 500.00 | — | — | ||
| SPLICING/DROPPING/TERMINATIONof each fiber/pigtail in the LIU/IOBOX/TERMINAL JOINTS throughfusion splicing of termination of OFCcables. The fibers terminated shallbe tested and test report (Hardcopy and soft copy) shall besubmitted to the Railway siteincharge for records. Each fibershall be properly marked withnecessary ferrules/tags. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 82,730 | |
| — | 1.00 | — | — | ||
| Supply of 2 Mbps Router, 2 LAN/4WAN port, 230V AC operated, asper RDSO spec. RDSO/SPN/TC/84/2008 Rev. 0 or latest, along with connecting cables, connectors etc. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 58,850.39 | |
| — | 2.00 | — | — | ||
| Supply and installation of FMS (24 F) rack mountable single mode with Suitable type with splicing and termination of OFC cables with all accessories (Pig tail and other materials required for work to be supplied by contractor ) Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 11,924.2 | |
| — | 50.00 | — | — | ||
| Supply of OFC jumper (patch chord)(10 mtr long) with FC/PC & SC or suitable connector at both end as per IRS:TC/81-2000 with latest amendmends. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 28,124.5 | |
| — | 50.00 | — | — | ||
| Supply & Installation of Patch cord RJ- 45 (3Mtr.) Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 10,822 | |
| — | 4.00 | — | — | ||
| Supply and installation of FMS (12 F) rack mountable single mode with splicing and termination of OFC cables with all accessories (Pig tail and other materials required for work to be supplied by contractor Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 14,490.12 | |
| — | 4.00 | — | — | ||
| Supply & erection of 15 feet GI pipe of 4" diameter of medium quality ISI No.1230 (Part1) 1990. Having iron base plate 10mm thick 30 cmx 30 cm welded at the bottom of pipe with 4 supports of iron bars of size 10 mm dia. The 3 feet shall be buried in the ground and 12 feet shall be above the ground. the work includes digging of pit on platform, laying of cable in between poles in suitable under gorund G.I. pipes, erection of pole and filling the pit with 1:3:4 cement, concrete and sand. final plastering should be done on the surface. The iron bracket on the top of the pole shall be provided to fix the CCTV camera and junction box/6U outdoor cabinet etc.( Necessary fixing and other materials required for fixing should be borne by the contractor). The work includes supply of all the material required in this item. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 14,460.32 | |
| — | 2.00 | — | — | ||
| "2Mbps Modems G.703 (E1) at carrier end and V.35 at DTE end complying RDSO SPECIFICATION NO.RDSO/SPN/TC/80/2020 Revision 2.0 Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document" | — | — | — | 23,926.2 | |
| — | 5.00 | — | — | ||
| Supply of G. 703 & V. 35 Optical Modem (Make Teamlink or similar) Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 86,730 | |
| — | 4.00 | — | — | ||
| Supply, installation,testing and commissioning of 24 port b10/100/1000 Mbps smart- managed POE switch with 4 SFP ports as per RDSO/SPN/TC/83/2020 Rev. 2.0 or latest. Inspection Authority: Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 71,512.48 | |
| — | 5.00 | — | — | ||
| Comprehensive Annual Maintenance Contract for Item no.(25,31,27,28,35) 5% anually after warranty period for 5 year Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document | — | — | — | 8,02,767.05 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
hakimpurTD_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .