Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical Insufficient Submissions |
Tender Value
₹7.6 L
EMD Value
₹15,148
Closing Date
24 Mar 2026, 11:00 amClosed
Executive Engineer
Jalpaiguri Construction Division
Installation of 10 nos Fire Check Door (FCD) at (G plus 4) MCH hub of Jalpaiguri Govt. Medical College and Hospital, Jalpaiguri under Jalpaiguri Construction Division, PWD, Jalpaiguri. (Civil Work) (2nd Call)
2026_PWD_1022583_1
WBPWD/EE/JCD NIeT No 25 of 2025-26 (2nd Call)
Open Tender
CIVIL WORKS
Percentage
45 days
Jalpaiguri
Pl. refer NIT
3 documents required · 3 mandatory
₹15,148
Yes
25 May 2026
14 Mar 2026
27 Mar 2026
17 Mar 2026
24 Mar 2026
17 Mar 2026
Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineerin- charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb. Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make. Forpair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating. All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineerin- charge. 2 hour Fire rated door double leaf of size (1470 mm x 2170 mm) Ground floor
Forst Floor
Secend Floor
Third Floor
Fourth Floor
Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style, made of heavy duty cast iron/ steel body & latches with SS, BHMA certified & conforming to ANSI A 156.3 for grade-1 (3 hours fire rated) and suitable for surface mounting to wooden/hollow metal/ Al framed door withopening upto 900mm, with maximum operating force 6 kg for unlocking easily & outwardly during emergency, complete in all respect as per direction & satisfaction of Engineer-in-Charge. (Note: To be installed at "FIRE EXIT" only under location specific instruction of Engineer-in -Charge.) for door opening 900
Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge. for leaf width upto 950mm
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc.
Door stopper.(Brass)
Brick work with 1st class bricks in cement mortar (1:4) In superstructure, ground floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in Ground floor as per relevant IS codes. (i) Pakur Variety
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary . [Excluding cost of chipping over concrete surface] With 1:4 cement mortar 15 mm thick plaster
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. In Ground Floor (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Add GST @ 18%
Add Labour Welfare Cess @ 1%
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.86 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_2513158.xls
BOQ • 0.33 MB
WBF2911.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .