Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.9 LAccepted-AOC 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | ₹24.9 L | 1 | Accepted-AOC Order Issued |
| 2 | 2₹25.5 LRejected-AOC SUKANTA PALLY NEAR TINBATI MORE WARD NO 32 SILIGURI DARJEELING 734005 | SILIGURI | DARJEELING | WEST BENGAL | 734005 | ₹25.5 L | 2 | Rejected-AOC L-2 rejected |
| 3 | 3₹28.0 LRejected-Finance BAUNIA NAZAT NORTH 24 PGS | ALIPURDUAR | WEST BENGAL | 735204 | ₹28.0 L | 3 | Rejected-Finance L-3 |
| 4 | Not Admitted-Fee/PreQual/Technical 60 K N C ROAD NAYAN KANAN BARASAT KOL 700124 | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | - | - | Not Admitted-Fee/PreQual/Technical Others-absent in site visit report duly signed by officer in charge |
Tender Value
₹35.1 L
EMD Value
₹70,172
Closing Date
13 Jan 2026, 10:00 amClosed
Chief Executive Officer
Paschim Banga GoSampad Bikash Sanstha. Bldg. No. 2, LB2, SectorIII, Salt Lake City, Kolkata 700106
Internal and external repairing including allied electrification work at Frozen Semen Bull Station and Bull Mother Farm Haringhata, Nadia-741246 under Paschim Banga Go-Sampad Bikash Sanstha for the year 2025-26
2025_ARD_977564_1
PBGSBS/ELEC-HGT/NIT-216/25-26
Open Tender
ELECTRICAL WORKS M/R
120 days
Paschim Banga GoSampad Bikash Sanstha. Bldg. No. 2
Site visit and prebid mandatory
4 documents required · 4 mandatory
₹0
₹70,172
Yes
Paschim Banga GoSampad Bikash Sanstha. Bldg. No. 2
2 Feb 2026
27 Dec 2025
15 Jan 2026
27 Dec 2025
13 Jan 2026
27 Dec 2025
27 Dec 2025 - 13 Jan 2026
7 Jan 2026
Supplying and fixing way double door 4 way make LEGRAND Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including S&F 100A FP Isolator as incomer-and S&F 2 Nos 63A SP MCB as out going Make:Legrand
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Incl 1 no 40 A DP Isolator as incommer and 12 no SP MCB as out going 2+12 Way Legrand make
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall Havells make 63A, 415 V
Supply and Fixing 20 W LED tube Crompton/Philips make with batten fitting incl all accessories directly on wall /celling with screw.
Supply and Fixing 48'' Orient Celling Fan Make:Summercool/New breeze
Supply and fixing 20 W LED tube light with polycarbonate driver in built with metal heat sink durabale sidded connection fittings(T 8 Crompton make) LT8-20-865-2 Incl supply and fixing Batten(DMLNU-T8) and Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length
Supply and Fixing supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Supply and Fixing extra downrod with Ivory painting
Drilling hole on fan motor and downrod incl. S&F split pin
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (Pwd/E-14,i & ii )
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish Average run 8 mtr
Supply & Fixing 240 V,6&20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Laying of 4 core 16 Sqmm XLPE/PVC insulated Aluminium armoured cable Mescab Make in underground trench 460 mm wide x 760 mm average deapth , with brick protection on the top of the cable with 8 (eight) nos bricks per meter , including filling the space between the brick & cabile and also the trench with sifteed soil, leveling up and restoring surface duly rammed, F-2, 1(a)+MR.(for Shed no. 1 to 5)
Supply and Laying of cable 2 core 10 sqmm Aluminium armoured Mescab make on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc.including supplying sockets, soldering materials, tapes etc. and making connection to switch BDB and BBC etc.F5
4 core x 16 sqmm. F-5/8(b)
4 core 50 sqmm
2 core 10 Sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required :25 mm dia
2. Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
Supplying and fixing double-door SPN MCB Distribution Board 6 way Sneider Make with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Incl Legrand make 40A DP Isolator incl 6 no 32 A Legrand make SP MCB
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (Pwd/E-14,i & ii )
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2. Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
Supply & Erection of Hood type Feeder pillars box(1200 mm X900mm) of 14 SWG (2.00 mm) thick M.S Sheet size (500 x 300 x 150 mm) with base frame cousists of 75 mm x 40 mm x 4.4 mm MS chanel and the piller box structure with 50 x 50 x 5 mm. MS angle iron 40 mm x 40 mm x 6 mm ,flat iron with necessary ventilation arrangement -2 sides inlc. Top of F.box and double door at both sides with locking arrangement incl. S&F 7-LVR Pad lock (best quality)with duplicate keys (2 sets) in both the doors & providing 2 (two) nos. earthing terminal in both side of F.box switch will be fixed on brick foundation incl. plastering and neat ceiment complete incl. 2 coats of synthetic enamel paints (Burger/Asian) over a coat of R.O primer. The Feeder piller box will be equiped with the following:- 1) S&F Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. L&T make AS incommer 2) Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required 2 nos 415 V, 415 A Dimension of Cu. bars: 4 x 50x5mm 3) Supplying and fixing 2 nos 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse 315 A L&T make as outgoing with operating handle.
Supply of the following cubical type panels made of 14 guage CRCA structure, base channel, complete with, moulded case circuit breakers, meters, indicating lamps, current transformer 1200X950X300 etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve in suitable bus chambers,interconnection, small wiring, name plate, danger plat, earth bus etc. & comprising of compartments with hinged door for each feeder & its accesories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust & vermin proof construction with rubber gasket attractively powder coating etc. The panel shall be free standing type/ wall mounted type as per relavant drawing and comprising with the following: 1 All MCCBS shall be with operating handle. 2 CTs burden shall be 15VA & accuracy class 1.0 3 CTs shall be cast resin type . 4 All MCCBs shall be with thermal magnetic/ Microprocessor based releases. 5 All indication lights shall be LED type. 6 All meter shall be digital/Analoge type. 7 Rated Short Time withstand current of all ACB's are Icw for one second. 8 Breaking Capacity of all MCCB's are Ics service breaking capacity
Incommer: Supplying and fixing 415 V Four Pole 250A Lrgrand make MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
OUT GOING Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 63 A Legrand make
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 160 A Legrand make
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 40A Legrand TPN
Supply Fixing Voltmeter-Ammeter meter with screws & other fixing materials incl. making necessary holes and connections
Supply and Fixing one set Indication Lamp LED Type for each phase
Supply and Fixing of CT
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers 415 V 600A on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 barX80X13
Supply & Fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support
Supply and Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Length 7 mtr 410SP i.e 73 kg
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating L&T make 315 A
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive
Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting
Painting of Steel Tubular Pole upto 9 Mtrs. along with arm bracket of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.PWD-H-2/4(A)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core 3 x 22/0.3 (1.5 sqmm)stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.PWD-E-9/1 b
Supply & Laying of 4 core 16 Sqmm XLPE/PVC insulated armoured cable Mescab Make in underground trench 460 mm wide x 760 mm average deapth , with brick protection on the top of the cable with 8 (eight) nos bricks per meter , including filling the space between the brick & cabile and also the trench with sifteed soil, leveling up and restoring surface duly rammed, F-2, 1(a)+MR.(For Street Kight 350 Mtr and for Lab 200 Mtr
Supply & Laying of 2 core 10 Sqmm XLPE/PVC insulated armoured cable Mescab Make in underground trench 460 mm wide x 760 mm average deapth , with brick protection on the top of the cable with 8 (eight) nos bricks per meter , including filling the space between the brick & cabile and also the trench with sifteed soil, leveling up and restoring surface duly rammed, F-2, 1(a)+MR.
Supply and Laying of one No. cable above 4 Core 50 sqmm XLPE/PVC insulated Aluminium armoured cable Mescab Make and in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Earthing the S.T pole by installing 50 mm dia 3.00 mtrs. Long Cl-B (ISI Medium GI pipe) GI pipe as per Gs. To efficient earthing.PWD-G-1/2 (A)
Painting of Steel Tubular Pole upto 9 Mtrs. along with arm bracket of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.PWD-H-2/4(A)
Supply and fixing Crompton make LED street 60W light LSTP-60-CDL INCL Fixing outdoor type fluorescent/SV/MV light fitting on pole including supply anf fixing 25 mm dia arm bracket
Supply and Fixing 100 W LED Flood Light Crompton make CFS- 504-100-57-60D-SL-GL-NSG
Supply and fixing Havells make Astronomical Street Light timmer panel 3 phase 6KW, INCOMMER 40A TPN,SAP Code IHXTSO306A incl. 3 pole contactor bypass switch/MCB suitable box DIN channel ,all accessories and connection
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required :25 mm dia
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 Core 16 Sqmm Cable
2 Core 10 Sqmm
4 core 50 sqmm
600mm X 400mm Digital S75 PeopleLink Interactive Display, Size/Dimension: 1707x1034x90.6mm, Size: 75 Inch
50 Kva Three Phase Servo Voltage Stabilizer, For IndustrialRated Capacity 50 KVA Usage/ApplicationIndustrialType 50 KVA Automatic Digital Servo Stabilizer Power 50 KVA Servo Voltage Stabilizer Capacity 50 KVA Industrial Servo Controlled Voltage Stabilizer Phase Three Phase Cooling Type Air cooled Input Voltage 200-500 Volt Output Voltage 415 Volts Control Type Micro controller Place Of Origin Delhi Current Type Digital AC Rating 50 KVA air Cooled Servo Stabilizer Frequency 50Hz Efficiency 98% In Output Set Content 20 - 40 Volt Warranty One Year Model Name/Number Servo50KVAIndustrial
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required incl booth end welding from Earth electrode to ST pole
Add: G.S.T. @ 18% of Rs.29,44,002=59 ( sum of Sl. No. 1.01 to 1.61) i.e. Rs. 5,29,920=47
Add: Labour Cess @ 1% of Rs. 34,73,923=06 (sum of Sl. No. 1.01 to 2.01) i.e. Rs. 34,739=23
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.24 MB
BOQ_2382084.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid