| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.5 CrAccepted-Finance | ₹6.5 Cr | L-1 | Accepted-Finance Accepted |
| 2 | L-2₹6.5 Cr+₹52,639.42 (0.08%)Rejected-Finance | ₹6.5 Cr+₹52,639.42 (0.08%) | L-2 | Rejected-Finance Rejected |
| 3 | L-3₹6.5 Cr+₹4.9 L (0.76%)Rejected-Finance | ₹6.5 Cr+₹4.9 L (0.76%) | L-3 | Rejected-Finance Rejected |
Tender Value
₹7.5 Cr
EMD Value
₹7.8 L
Closing Date
30 Oct 2023, 5:00 pmClosed
EE Rampur
JSD Rampur
Providing LIS from Machhada Khad to Village of GP Nirath Tehsil Rampur Distt. Shimla HP
2023_HPIPH_80509_1
EE-JSD-RMP-E-TEN/23-7932-82DT. 20.10.23
Open Tender
Civil Works
Item Rate
545 days
Rampur
Please refer Tender documents.
12 documents required · 12 mandatory
₹2,500
EE Rampur
₹7.8 L
6 Feb 2024
20 Oct 2023
31 Oct 2023
20 Oct 2023
30 Oct 2023
20 Oct 2023
Amount
Cutting in earth work in all classification of earth work such as pick work, jumper work, saturated soil, blasting soft/ hard rock or chiselling soft/ hard rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering where ever required, stacking the serviceable/ unserviceable materials/soil separately complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Excavation in earth work and disposal of all excavated earth up to all leads and lifts, disposed earth to be levelled neatly dressed as per direction and to the entire satisfaction of the Engineer-in-Charge.
Excavation in foundation trenches etc.(for pipes & pits upto all depth) in earth work in all classification of earth work such as pick work, jumper work, saturated soil , blasting soft/hard rock or chiselling soft/ hard rock including wedging out of a rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering and dewatering where ever required, stacking the serviceable/unserviceable materials/soil separately and after laying and jointing of pipes, returning the usable soil in trenches in 15 CM layers including consolidation of each deposited layers by ramming and watering and then dispositng of all surplus excavated soil, useable materials as directed within all leads/lifts including restoration of metalled surfaces to its original condition and including cost of diversion for traffic night signals, fixing caution boards, crossing over trenches for access to houses fencing etc. complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and laying cement concrete 1:5:10 ( 1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:4:8(1Cement: 4Sand: 8Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying cement concrete 1:3:6(1Cement: 3Sand: 6Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced cement concrete work in :-
In suspended floor roofs ,landing and shelves and their support.balconies , beams,girders, bressumers and contilever up to floor two level with in all leads and lifts.
Providing and laying cement concrete 1 : 1.5 :3(1 cement :1.5 sand :3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcemnt for reinforced concrete work complete in all respect with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge .
Foundation,footing,bases of columns and the like & mass concrete.
Walls (any thickness but not less than 0.10m thickness) attached pillaster, buttresses, plinth & string courses etc from top of foundaation level upto floor two level as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Beams, girders, bressumers & cantilevers upto floor two level
Columns, Pillars, Piers, Abutments, Posts and Struts
Prov.form work with steel plates 3.15mm thick welded with angle iron frame 30 x 30 x 5mm so as to give a fair finish including centring, shuttering,strutting & propping etc. with wooden battens and ballies, height of propping & centering below supporting floor to ceiling not exceeding 4mtr.& removal of same for insitu rainforced concrete and plain concrete work complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Foundation,footing,bases of columns and the like & mass concrete.
Vertical surfaces such as walls ( any thickness ) partition and the like including attached pillasters buttresses, plinth and string courses and the like.
Column , Pillers & post upto floor two level square, rectangular & polygonal in plain
Edges of slab and break in floor 20 cm wide
Beam Cantiliever girders & lintels side and sofit to beam , beam haunches , cantilever girders nor exceeding 1 mtr depth.
Providing mild steel / tor steel reinforcement for reinforced cement concrete work including bending, binding and placing in position complete upto floor two level complete in all leads and lifts and as per the direction and to the entire satisfaction of the Engineer-in-Charge. Tor Steel.
Brick work using common burnt clay building bricks in Foundation & plinth in cement mortar 1:6 ( 1 cement : 6 ) II nd class bricks.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 2nd. Class deodar wood.
Providing and /Fixing Pannelled & glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hings necessary screw 40 mm thick 2nd class deodar wood.
15 mm thick cement plaster on fair side of brick,stone masonary convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80 mm girth in cm 1:6 (1 cement:6 sand)
Applying Birla white wall care putty over plaster surface after throughly brushing the surface free from mortor drops, dust, loose materials and other foreign matters sand pappered smooth to give final matt finish to the surface complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
Applying Priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other forgien matter
Painting two coats (excluding priming coat) on new wood on wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt dust and other foreign matters other than white paint.
Wall painting ( two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete/ stone/plastered wall surfaces to give an even shade including throughly brushing the surface free from mortor dropping and other foregien matter and sand papered smooth including applying of putty a required for the surface complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
P/F of MS grill of required pattern in wooden frames of windows etc, with M.S Flats, squre or round bars with rounded headed bolts and nuts or by screws complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
Prov & Laying Vitrified tiles 5.5 mm thick in flooring (300 x 300mm size) treads of steps laid on a bed of 12 mm thick cement mortor 1:3 ( 1: cement: 3 sand) finished with pointing in white cement.with in all leads and lifts complete in all respect. ( In walls)
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) i/c finishing the top surface of complete smooth within all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Providing /Fixing Anodizedanodized aluminiumsliding door bolts anodized colour and shade with bolts and nuts screw etc complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
(300 mm x 16 mm)
Providing /Fixing aluminium towers bolts barrel type anodized trans parent or dyed to required shade and colour with screws etc complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
250 mm x10 mm
Providing /Fixing Anodized aluminium handles with screws etc. complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
125 mm dia
Providing /Fixing bright finished hard drawn hooks and eyes complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
150 mm dia
Providing 40x3 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm dia meters bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15 cm 1:3:6 (1 cement:3 sand:6 graded stone) at 200 mm nominal size within all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Providing and Fixing 100 mm brass floor door stopper with rubber cushion screws etc to suit shutter thichness complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
Providing in RCC work smooth finishing of the exposed surface with Cement mortar 1:3 (1 Cement : 3 Sand) & as per direction & to the entire satisfaction of the Engineer-in-Charge.
Steel work welded in single section including cutting , hoisting fixing in position and applying a priming coat of red lead paint
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing, Manufacturing, supplying and fixing of M.S. Angle 50x50x6 mm having 1.80 mtrs height and hold fast at bottom and fencing panal of size 1.20x 1.20 Mtrs of Jali of 14 gauge having 25x25mm mesh with M.S. Angle 40x40x5 mm including cutting welding and painting with red oxide paint followed by a cost of metal enamel paint to good exterior glistering look and rendering smooth with hold fast made of M.S. Angle 40x40x5 mm 4 nos complete in all respect and as per the direction and entire satisfaction of the engineer in charge.
Providing and laying PVC ( D-Plast) pipes 75 mm dia for weep holes in retaining wall .complete with in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
Providing & Fixing 0.63 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 micron over 5 micron primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks bolts and nuts 6 mm diameter with prepainted jimpet and rubber washers complete with in all accesories as required complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
0.63 mm thick sheet prepainted for roof
Providing & Fixing ridges of hips 60 cm overall width 0.63 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 micron over 5 micron primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks bolts and nuts 6 mm diameter with prepainted jimpet and rubber washers complete with in all accesories as required complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
0.63 mm thick sheet (prepainted )
Supplying and fixing rolling shutter of approved make made of 80 mm x1.25 mm M.S laths interlocked together through their entire length and joined together at the end by end locked mounted on specially designed pipe, shaft with bracket side guide and arrangements for inside or outside locking with push pull operation com plete but excluding the of the top cover and spring ( shutters having width below 3.5 meters) complete with in all leads and lifts and as per the directioin and to the entire satisfaction of the Engineer-in-Charge
Constructing chamber for sluice valve, 1.00x1.00x0.75mtr size (inside) & RCC top slab in cement concrete 1:2:4 mix (1cement:2sand :4 graded stone aggregate 20 mm nominal size) (with 150 mm thick walls of rcc 1:2:4 (1cement:2sand:4 graded stone aggregate 20 mm nominal size) complete with form work & reinforcement with 8 mm bars at not exceeding 150 mm centres both ways)
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia. & 180 mm deep(inside) with chained lid RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways
Providing,Laying, fixing, jointing & testing in trenches MSRW flanged pipes fo following diameters/class conferming to ISO:3183-2007 (PSL, Gr.X - 42 , X-60), of following diameter, class/grade (latest with up to date amendments) having wall thickness as specified below with plain end and capable of withstanding required test pressure in radam length of 4 - 7 meters including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges ( MS flanges shall conferm to BIS 6392-1971 or with latest upto date amendments) duly welded with after every 100 meter joints/wherever required with flanged welds & remaining other Circumferencial Butt Welded joints by electrical arc welding to required dia MSRW Pipe welded in requisite number of weld runs two layers (two inner and two outer) with pipes at both ends as per relevent BIS standars along with nuts and bolts of required sizes including cost of die penetration test, 3mm thick compressed asbestos fibre/synthetic rubber gasket conferming to relevent BIS standared so as to achieve the minimum effective throat thickness of weld conforming to IS : 814 of Advani Oerlikon/L&T or ISI markes make.
The laying of pipe will include all operation such as cutting, welding, jointing, providing and fixing of MS flanges, fabrication of bends, tees and die penetration tests etc. including lowering and laying in excavated tenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer-in-charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and out side) as per relevent IS standards and the damaged porition of the pipes and specials made from the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of atnicorrossive paint over priming coat as per AWWA specificationc C-203-1978. ( Earth work in trenches will be measured and paid for separetely).
Gravity Main L-290 or x-42 300 mm dia
RD 00 to 300 T-5 (4.80)= 300 Rmt
Ist stage L-415 or X-60 300 mm dia
RD 00 to 300 T-28 (7.10)
RD 300 to 600 T-28 (6.40)
RD 600 to 900 T-23 (4.80)
RD 900 to 1200 T-11 (4.80)
RD 1200 to 1500 T-5 (4.80)
2nd stage L-290 or X-42 250 mm dia
RD 00 to 300 T-17 (4.80)
RD 300 to 450 T-11 (4.80)
RD 450 to 600 T-5 (4.80)
Laying ,jointing and testing of GI pipe of following dia at site with circumfrential butt welding (in three layers) at both ends according to relevant BIS stanards/approved specifications.The welding of pipe with butt welding should confirm to IS: 816-1965 (with upto date amendments) to make the joint leak proof and air tight including bends of required degree complete in all respects.The welding electrodes shall be as per IS 814 -1967of Advani/Oerlinken/L&T or ISI marked make.The Welding of Socket joint sould be done in two layers on both ends of socket to make the joints air tight upto all leads and lifts to entire satisfaction of the engineer in charge.
100 mm nominal diameter.
125 mm nominal diameter.
150 mm nominal diameter.
Laying, jointing and testing in trenches to be levelled to grade galvanised mild steel pipe light grade of following nominal diameter including fittings complete in all respect to the entire satisfaction of the Engineer-in-Charge. ( Earth work in trenches to be measured and paid for separately).
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
65 mm nominal diameter.
80 mm nominal diameter.
Making connection of G.I. distribution branch with G.I. main of 80 mm dia by providing and fixing tee, including cutting and threading the pipe etc. complete in all respect to the entire satisfaction of the Engineer-in-Charge.
15 to 25 mm nominal diameter.
Providing & Supplying of cast iron sluice valve without flange without flange of following dia class PN 1.6 i/c cost of rubber inspection washer (gasket) etc open end with hand wheel confirming IS : 14846 having test pressure of 10.20 kg/ sqcm of leader /kirloskar making complete in all respect including carrage in all leads and lifts as directed by Engineer-in-Charge
65 mm nominal diameter.
80 mm nominal diameter.
100 mm nominal diameter.
125 mm nominal diameter.
150 mm nominal diameter.
Providing & fixing full way valve with wheel of following diameter complete within all leads and lifts.
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
Providing horizontal spindle horizontal split casing/end suctions (back full out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar as per IS-1520-1980 / IS 5659 - 1970 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear / raw water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage / Slipring drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
2 Nos. Pump set ( i.e 1 No. working simultaneously & 1 No. Pump stand by (Ist Stage
A) SITE CONDITIONS i) Location of site= Sub Mergedarea satluj River near Machhada Khad ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 875 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 8 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 30 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read with 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = Sufficient to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 2 Nos pumps working b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 34.46 LPS for each pump. ii). Total head in Mtrs. If total head is not known then following details be provided:- 600.42 i)Static head /Discharde Head = 592.00 Mtr ii)Minimum depth of water= Positive suction. iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 1800 Mtr iv). Dia of R/Main= 300 mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)15% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tenderer (manufacturers certificate to be appended.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting & stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal & other error, i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection, overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of Kirloskar/Leader/KSB/ make of cast steel double flanged sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 600 ASA (seat pressure 112 Kg/cm^2) as per BS 1414 ( MSEW -80 mm dia).
Providing and fixing of Kirloskar/Leader/KSB/ make of suitable size cast iron/cast steel double flanged Automated/ self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 112 Kg/cm^2) as per BS-1414 ( MSERW pipe-125mm dia) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from Tranformer of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 2 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Non Returning Valves of approved make makes such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED as per BIS 1868 including all leads and lifts complete in all respect.
300 mm dia ASA-600
Providing horizontal spindle horizontal split casing/end suctions (back full out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar as per IS-1520-1980 / IS 5659 - 1970 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear / raw water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage / Slipring drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
2 Nos. Pump set ( i.e 1 No. working simultaneously & 1 No. Pump stand by (2nd Stage )
A) SITE CONDITIONS i) Location of site= Near Barkeli ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 1450 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 8 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 30 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read with 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = Sufficient to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 2 Nos pumps working b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 23.99 LPS for each pump. ii). Total head in Mtrs. If total head is not known then following details be provided:- 244.32 i)Static head /Discharde Head = 230.00 Mtr ii)Minimum depth of water= Positive suction. iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 600 Mtr iv). Dia of R/Main= 200 mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)15% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tenderer (manufacturers certificate to be appended.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting & stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal & other error, i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection, overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of Kirloskar/Leader/KSB/ make of cast steel double flanged sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 600 ASA (seat pressure 112 Kg/cm^2) as per BS 1414 ( MSEW -80 mm dia).
Providing and fixing of Kirloskar/Leader/KSB/ make of suitable size cast iron/cast steel double flanged Automated/ self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 112 Kg/cm^2) as per BS-1414 ( MSERW pipe-125mm dia) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from Tranformer of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 2 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Non Returning Valves of approved make makes such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED as per BIS 1868 including all leads and lifts complete in all respect.
150 mm dia ASA-600
HYDRAULIC ENGINEERING COMPANY
SS RANA CONSTRUCTION PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .