Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹35,624.07 (0.33%)Rejected-AOC | ₹1.1 Cr+₹35,624.07 (0.33%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.2 Cr+₹8.8 L (8.08%)Rejected-AOC | ₹1.2 Cr+₹8.8 L (8.08%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.1 Cr
EMD Value
₹50,000
Closing Date
23 Dec 2019, 6:00 pmClosed
DGM
KEL Kochi
IMPLEMENTATION OF RUSA II-Muhammed Abdurahiman Memorial Orphanage College, Mukkam,Kozhikode (2 Works)
2019_KEL_329045_1
KRO/ BDC/424/2019
Open Tender
Civil Works - Others
Item Rate
300 days
KEL Kochi
As per NIT
5 documents required · 5 mandatory
₹5,900
online
₹50,000
8 Feb 2020
11 Dec 2019
26 Dec 2019
11 Dec 2019
23 Dec 2019
11 Dec 2019
11 Dec 2019 - 23 Dec 2019
Amount
Muhammed Abdurahiman Memorial Orphanage College, Mukkam-Constructuion of 3 Class Rooms and 4 Girls Toilets
Muhammed Abdurahiman Memorial Orphanage College, Mukkam Constructuion of 3 Class Rooms and 4 Girls Toilets
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size). Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size. Assessment of strength of concrete by cube testing in Govt. lab.
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more.Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preferences
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
6.4.2 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.1.1 : 12 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.2.2 : Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required sized with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer in-charge using Pincoda wood.
11.41.1 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref. and prior sample approval.
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref.
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer.Make: Asian, Berger, Nerolac or eq. in the order of pref.
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).Make: Asian, Berger, Nerolac or eq. in the order of pref.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work.Make: Asian, Berger, Nerolac or eq. in the order of pref.
od2353/2019_2020 : Providing grooves 6 mm wide and 6 mm deep in plastered surface to clear the joint of RCC columns, beams with walls including all cost etc complete
od2502/2019_2020 : Providing water cutting 20mm wide and15mm thick in cement mortar 1:3
ELECTRIFICATION CHARGES @ 5.5% including preperation of estimate based on PRICE/PWD schedule, preperation of drawing and getting approval from KEL/client and payment after deducting tender below.
Note for Electrification work
Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Push Button- L&T, Schneider, Rishabh
SANITARY AND WATER SUPPLY ARRANGEMENTS including preperation of estimate based on PRICE/PWD schedule, preperation of drawing and getting approval from KEL/client and payment after deducting tender below.
Note: Make of water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of installation, testing and commissioning cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD/Irrigation Dept. specification and direction of Engineer at site.
Setting of Audio visual Room for Muhammed Abdurahiman Memorial Orphanage College , MANASSERY, Mukkam
SECTION A
Setting of audio visual room
Pro 8510L XGA Projector 1024 x 768 resolution , 5200 lumens, 1.6X optical zoom, vertical and horizontal keystone, 4 HDMI inputs, lamp warranty one year, three year warranty etc of approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of PA Speaker system SRX220<br>200w Two way speaker system with two year warranty of approved make with prior approval of KEL/Client.
Dual Channel PA System AHUJA DXA1802<br>900+900W RMS two channel amplifier with two XLR inputs, Protection : Temperature, DC, RFI, Short circuit, overhead, AC over voltage, Built in limiter, two year warranty. Approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of PA AUDIO MIXING CONSOLES- STEREO AMX 912- 9 channel audio mixer, Each channel has GAIN, BASS, TREBLE, ECHO, PAN and slide LEVEL controls with CLIP LED indicator. With stereo outputs. Approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of Ahuja AWM- 520VHL wireless microphone DUAL PA VHF wireless microphones, two year warranty, with XLR/ Balanced outputs. Approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of Ahuja AWM- 700U2 PA wireless microphone with dual hand held mic, two year warranty, XLR/Balanced outputs. Approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of Wired MicAhuja Wired Mic with two year warranty. Approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of Laptop ASUS TUF FX505 Intel Core i7 8th Gen 15.6 inch FHD Gaming Laptop - 8 GB/1 TB Hybrid HDD (FireCuda) + 256 GB SSD/ Windows 10/GTX 1050 T. Approved make with prior approval of KEL/Client.
Supplying, installation and commissioning of Commercial display Inverter and battery. Approved make with prior approval of KEL/Client.
Supply ,installation, testing and commissioning of Split Air conditioner 1.5 TR with stabilizer: Supplying, installation, testing & commissioning of split Air conditioners suitable for single phase, 50Hz, 230 volts, A/C supply with hermetically sealed compressor with air cooled condenser, motor capacitor start run, capacitors relay and over load protector inter connections including all accessories and remote with special purpose A/C stabilizers, etc as required.(4 star & above). Make: Blue star, Voltas or Eq. make in the order of pref.
Supplying, installation and commissioning of Wall fan;Wall fan Good quality. Make : HAVELLS, CROMPTON, USHA or Eq.
Construction and fixing of wooden Podium for audio visual room including cost of material and labour etc complete.Approved make with prior approval of KEL/Client.
Supplying of Silver Screen High grain screen available of size 5 m x 3 m. Approved make with prior approval of KEL/Client.
Cutting Of laterite
2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited).
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size). Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more.Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preferences
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick
SECTION C
RENOVATION OF MCJ LAB WITH A SOUND PROOF RECORDING STUDIO
26.24.1 : Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518: 1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete.With 15 mm thick fully perforated square/butt edge light weight calcium silicatepanels/ tiles.
26.24.S.A.R.2 : Fill the groove (i.e. 2-3mm gap between boards),taping and jointing 8mm thickfiber cement board and 12.5mm thick gypsum plaster boards with epoxy basedsealing compound, Acrylic based sealing compound, Non woven reinforcementTape as per direction of Engineer in charge.(Use a flexible knife so that no airbubble is entrapped. Allow 1-2 hours gap. Once hard tacky or set, apply a coatof Acrylic based sealing compound paste to flash fill the beveled area. After2-4 hours go on to repeat a skin coat with Acrylic based sealing compound tosecurely embed the 40mm width (non woven reinforcement Tape. Use onlyflexible steel knife, such as provided with packs, to avoid air entrapment withincompound. After overnight drying shrinkage apply a coat of acrylic basedsealing compound to compensate shrinkage. Finally cover the bevel portionwith any suitable overall skin coat with a desired full surface-leveler material). Make with IS.
26.26.2 : Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With fully perforated 12 mm thick micro tegular edged or 10 mm thick squareedged GRG false ceiling tiles.
Renovation of physics lab by tiled flooring and finishing
11.41.1 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm. Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref. and prior sample approval.
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(Rate is inclusive of additional bed of CM 1:3 ,12mm thick which has to be done seperately). Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref.
Labour for Adjusting Height of doors (By providing Log book and certifying output as per PWD norms etc as per the direction of Engineer at site.
Expansion of computer science lab
11.41.1 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref. and prior sample approval.
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
13.1.1 : 12 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand).
Labour for Adjusting Height of doors
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.
21.3.2 : Providing and fixing glazing in Aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness.Make: Saint Gobain,Modiguard or Eq. with IS
The venesian blinds for windows made with aluminium channel fixtures,canvas leaf with fiber chair bottom and nylon string for leaf sliding including all cost of metrials and labour(per sqm).
Supplying and installation of Philips Astra Prime 22-Watt LED Panel Light (Cool Day Light, Round) led ceiling light sets. 6-8" square or circular of Havells, Wipro or eq. make. (Prior sample approval required).
Wiring for computers and ceiling Lights
1.1.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
Renovation Of Examination Room
15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
13.1.1 : 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
Providing and fixing precoated galvanised iron profile sheets (size, &;shape and pitch of corrugation as approved by Engineer-in-charge)&;0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120&grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns&epoxy primer on both side of the sheet and polyester top coat 15-18µns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineerin-&charge. The sheet shall be fixed using self drilling /self tapping&screws of size (5.5x 55 mm) with EPDM seal, complete upto any&pitch in horizontal/ vertical or curved surfaces, Excluding cluding the cost of purlins, rafters and trusses and including cutting to size and shape&wherever required. Make:TATA,JSW,BHUSHAN,GEO or Eq
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes. Make: TATA, JSW, VIZAG, SAIL or eq.
Staff room , Guest room, Administrative office and IQAC office Renovation of IQAC office.
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.
13.26 : Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.Make: Asian, Berger, Nerolac or eq. in the order of pref.
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work. Make: Asian, Berger, Nerolac or eq. in the order of pref.
Supply , Installation ,Testing and commissioning of Split A/C Room size 4.60*4.10m-Recommended 1TAC including all accessories as per approved specification and prior approval of client/KEL. Make: Blue star, Voltas or Eq. make in the order of pref.
Flooring for Administrative Office
11.46.1 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm. Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref and prior sample approval.
Flooring For Staff Room
11.41.1 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref and prior sample approval.
SECTION E
Digging Of well
3.13.2.A : Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work. Ordinary Rock (not requiring blasting) - Manual Means - (Depth upto 3 m)
RCC ring
5.7 : Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.9.12 : Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more. Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preferences.
10.25.2 : Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Make: TATA, JSW, VIZAG, SAIL or eq.
SECTION F
ELECTRIFICATION WORKS( SUPPLY OF ITEMS AT SITE AND ONLY USED ITEM MAY BE PAID)
MAMO_ Ceiling Rose
MAMO_TUBE LIGHT 40W LED batten tube light
MAMO_ 2 inch steel bolt
MAMO_ iNSTALLING NEW CEILING FAN -Crompton Make
MAMO_ Ceiling fan replacing
MAMO_8 MD PLATE
MAMO_6Amps plug socket
MAMO_6Amp 1 way switch
90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
MAMO_ 1sqm Wire roll
MAMO_1.5Sqm Wire roll
MAMO_20mm elbove
MAMO_20mm Pipe bend
MAMO_insulation tape
MAMO_1 Inch black star screw
25 A wall plug
MAMO_20mm Clamp
MAMO_20mm 2 way JB
MAMO_ 20mm 3way JB
MAMO_ PVC pipe - 20 mm -150 mm long
MAMO_ 10 Nos Crabbing Socket
MAMO_10 Amps MCB
MAMO_ 6 Amps MCB
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earthelectrode, including connection/ termination with GI thimble etc. as required.
MAMO_50A HRC Link
MAMO_ 63A SFU
MAMO_32A TPN MCB Dx3
MAMO_25mm UG cable clamps
MAMO_4-pole ELCB 30 mA
MAMO_63A 4 pole isolator
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB
MAMO_ 25mm cable gland
MAMO_25x4 UG Cable- Aluminum Conductor
Labour Charges (for item SECTION F )
Electrical Works for economics department
90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
MAMO_TUBE LIGHT 40W LED batten tube light
MAMO_ iNSTALLING NEW CEILING FAN -Crompton Make
MAMO_6Amps plug socket
MAMO_6Amp 1 way switch
MAMO_ Ceiling Rose
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
Labour Charges (for item Electrical Works for economics department )
Note: LIST OF APPROVED BRANDS / MAKES FOR ELECTRICAL ITEMS ATTACHED
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of installation, testing and commissioning cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD/Irrigation Dept. specification and direction of Engineer at site.
Daybro constructions
Roy Tom
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .