Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.7 L+₹60,429 (3.00%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹21.1 L+₹97,000 (4.82%)Rejected-Finance | L3 | Rejected-Finance Reject |
Tender Value
₹13.0 L
EMD Value
₹26,033
Closing Date
29 Jul 2024, 11:00 amClosed
Executive Engineer
Jal Shakti Division, Nahan, PO and Tehsil Nahan, Distt. Sirmour, HP
Drilling, lowering, assembling and development of Tubewell 300 mm dia, 30 mtrs deep, 2 Nos.
2024_HPIPH_90685_1
NHN-SMR00-722-2286-2350 Dated 18-07-2024
Open Tender
Civil Works
Item Rate
90 days
Nahan
Please refer to tender documents
10 documents required · 10 mandatory
₹400
EE JS Division Nahan
₹26,033
Yes
5 Dec 2024
18 Jul 2024
29 Jul 2024
18 Jul 2024
29 Jul 2024
18 Jul 2024
Amount
Drilling and Lowering of tube well 1 No. Transporation of Rig alongwith allied accessores etc. complete including errection and levelling at site through all kinds of roads, approaches fields etc. in all leads, lifts upto site of work complete in all respects as per the direction of the Engineer Incharge.
Earth work in foundation for digging tubewell in all kinds of soil including dewatering sloring struting from ground level upto 5 metres including disposing excavated soil in all leads,lifts complete in all respects as per the direction of the Engineer Incharge 0 to 5 mtrs.
Drilling of bore as per specifications laid down in IS 2800-1991 (Part-I) with upto date ammendments (if any) with percussion rig starting with 650-600 mm dia M.S. pipe reduded to 450-400 mm dia MS pipe conforming to IS 4270-2001 with upto date ammendments (if any) in all kinds of soils boulder rocks collepsible strata saturated so as artesian conditions including the cost of all consumbales stores water fuel lubicants and other accessories etc complete in all respects as per direction of the Engineer Incharge.
Drilling and lowering of MS casing pipes conforming to IS 4270-2001 with upto date ammendments (if any) of suitable sizes as mentioned above from 5 to 30 metres below ground level with all leads and lifts.
Collection, preservation and display of suitable size sample box with top lid and locking arrangement till balancing over of the tube well to the department, complete in all respects as per direction of the Engineer Incharge.
Supplying and lowering of IS marked Electric Resistance welded M.S. pipe 300mm dia nominal size housing ,8 mm thick having out side dia mtrs. 323.9 mm , screwed end,socketted , confirming to IS: 4270 - 2001 with up-to-date ammendments, if any, about 4mtrs. To 7 mtrs.in length,welded without any circumferential joints, into bore hole in vertical position including cost of all scaffolding derricks, poles,clamps embedded in foundation etc. Including cost of all cutting,threading and welding of pipes etc. within all leads and lifts,complete in all respects as per the directions of the Engineer in-charge.
Supplying and lowering of IS marked Electric Resistance welded M S Slotted pipe 300 mm dia nominal size housing 8 mm thick having outside dia meters 323.9 mm screwed end socketted confirming to IS 4270-2001 with upto date ammendments if any about 4 mtrs to 7 mtrs in length welded without any circuferential joints into bore hole in vertical position including cost of all scaffolding,derricks ,poles clamps embedded in foundation etc including cost of all cutting threading and welding of pipes etc within all leads and lifts complete in all respect as per the direction of the engineer in charge
Providing and fixing M.S. Centralized guides at suitable spacing for each tubewell as per IS 226-1991 with uptodata ammendments , if any, within all leads, lifts 1x4Nos complete in all respects as per the direction of the Engineer Incharge.
Providing and fixing in position threaded iron cap with locking arrangements of approved design to prevent foreign matter from getting into bore hole, as required, within all leads, and lifts complete in all respects, as per direction of the Engineer Incharge.
Supplying and packing of gravel consisting of hard quartz or other suitable materail, with an average specific gravity of not less than 2.5 not containing more than 2% by weight of thin flat or elangated pieces shall be of sub founded to rounded grains with mininimum angular features of size 2-2.35 mm, shall be free from impurities such as shafe, shale, mica, felspar, clay , sand, dirt , loam hamatite and organic materials as per IS 4097-1967 with upto date ammendments, if any around intake of tubewell with minimum thickness of should around screen generally 100mm to the entire depth of the bore as per IS 2800 (part-I) 1991 with upto date ammendments, if any,with in all leads, lifts complete in all respects as per directions of the Engineer Incharge.
Extraction of all sizes blind/ casing/housing pipes with machine starting from the bottom of the bore hole, within all leads, lifts complete in all respects as per direction of the Engineer Incharge.
(a) In contact with soil
Development of tubewell by back washing method, with air compressor of minimum 750 CFM capacity , pumping pipe of 200mm size and air line of minimum 65mm size or with other suitable method, till the well is throughtly developed as per clause 4.2 of IS 111.89 : 1985 with upto date ammendments , if any complete in all respects as per direction of the Engineer Incharge.
Development of tube well by continuous over pumping method with VT pumps/ submersible pumps of suitable capacity not less than double the discharge established by the compressor method/ design discharge, untill the well is sand free as per IS 11189-1985 with uptodate ammendements, if any complete in all respects as per diection of the Engineer Incharge. The draw down and dischage to the established by running the VT/ submersibloe pump continuously for 8 hours in the presence of office not less than the rank of Assistant Engineer.
Testing of verticality of the tubewell as per clause 4.3 of IS 2800 (part-II) 1979 with uptodate ammendments, if any, using kplumb or plunger 6mm smaller in dia within the inside diameter of the well casing . The results of the verticality test shall be recorded on proforma shown in appendix A of IS 2800 (part-II) -1979 with upto data ammendments, if any, as appended with the tender documents and handed over complete in all respects as direction of the Engineer Incharge.
Dismentalling of rigs or other allied accessories after completion of job within all leads, lifts complete in all respects as per diection of the Engineer Incharge.
Handing over of the tubwell in complete shape as per appendix B of the clause 7 of IS 2800 (part-II) 1979 with upto date ammendments, ifany, as appended with the tender documents in laminated form in tripicate, complete in all respects as per direction of the Engineer Incharge.
M/S Sharma Enterpirses
HIMANSHU CHAUHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .