Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC PO BINNAGURI DIST JALPAIGURI WEST BENGAL PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.0 L+₹2.6 L (7.48%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹40.5 L+₹5.2 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹40.5 L+₹5.2 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹40.9 L+₹5.6 L (15.8%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L5 | Rejected-Finance Being L5 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
8 Dec 2022, 6:00 pmClosed
GE North Binnaguri
Post Binnaguri Dist Jalpaiguri West Bengal
SPECIAL REPAIRS TO BUILDING NO OTM 7 DM 1 2 3 4 NORTH BLOCK UNDER GE NORTH BINNAGURI
2022_MES_548938_2
NIT No. 8701 / 42 / 2022-2023 / 03 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BINNAGURI
Class D Category a i
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹75,000
Yes
6 Feb 2023
19 Nov 2022
10 Dec 2022
19 Nov 2022
8 Dec 2022
26 Nov 2022
Amount
SCHEDULE `A' ( CIVIL WORK) Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), in floors, aprons etc .laid dry or laid dry and pointed including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.complete all as specified.
Roughening surfaces of old concrete floor/ verticle surface by picking, sweeping clean and washing down with water to remove dust etc.and prepare the surface to receive tiles including applying 3Kg/Sqm cement slurry complete all as specified and directed.
Material and labour for machine cut Kota stone slab as in flooring, 18-20 mm thick area of each tile exc 0.18 sqm laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20 mm thick screed bed / beeding layer in CM 1:6 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Material and labour for machine cut Kota stone slab , 18-20 mm thick as in verticle surfaces such as riser of steps , skirting , dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick screed bed / backing layer in CM 1:4 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screeding in CM 1:6 complete all as specified. (Note : screed bed shall not be measured and paid separately).
Material and labour for glazed ceramic coloured / digital printed of size (300 x 200 mm / 300 x 450 mm x 7 mm thick ) as in vertical surfaces such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. (Note : screed bed shall not be measured and paid separately).
Supply and fixed in repairs vitreous china wash basin (WHB) , white , flat back , size 550 mm x 400 mm (1st quality) including brackets, waste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting for and pinning in ends of brackets or erecting stand but but incl providing brackets, waste pipe & CP waste coupling , PVC connection 450 mm long complete all as specified and as directed.
Supply and fixed in repair, 15 mm bore dia of pipe , chromium plated ,pillar taps, fancy type, cast copper alloy , with capstan heads, screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified.
Supply and fixed of PTMT connections 15 mm size with PVC nuts of length 450 mm complete all as specified.
Supply and fixed in repairs of Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats .(Minimum weight 170gms complete all as specified.
Supply and fixed in repair cast copper alloy Bib taps suitable for 15 mm bore pipe screwed down , screwed for iron pipe or for brass ferrule and fixed complete all as specified .
Supply and fixed in repair CP angular stop cock fancy type, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified .
Supply and fixed in repair, CP stop cock ( concealed type) long fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified
Cutting chases in brick work, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades,shelves, lintels,etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc.,and making good, cutting not exc 10 cm girth complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing and removal of unserviceable pipe from work site,15 mm bore dia all as directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing and removal of unserviceable pipe from work site, 20 mm bore dia all as directed.
Supplying , laying, jointing and testing 15 mm nominal bore Steel water tubes, 'medium grade' ,galvanised , with all fittings ; fixed to walls and ceilings or laid in floors complete all as specified.
Supplying , laying, jointing and testing 20 mm nominal bore Steel water tubes, 'medium grade' ,galvanised , with all fittings ; fixed to walls and ceilings or laid in floors complete all as specified.
Supply and fixing in repairs PVC (SWR) multi floor trap of size 75 mm / 110mm , plain with grating including jointing with solvent cemnt complete all as specified and as directed.
Supply and fixed in repairs low level flushing cistern, 9-10 litres capacity ISI marked embossed moulded from virgin poly propylene including flush pipe complete all as specified and directed.
Supply and fixed rotational moulded poly-ethylene multilayer water storage tanks ( cylinderical vertical with closed top ) 1000 litres capacity ,hoisted and fixed in position complete all as specified including dismantling PVC water tanks, including removing ball valve and removing unserviceable tank from work site complete all as specified
Disconnecting existing tanks, setting aside (or lowering of required) for repairs , cleaning, etc. and hoisting if required reconnecting and refixing in position including cleaning and removing all scale and dirt, and ball valve etc., from tanks and from mouths of circulating pipes complete all as specified
Supply and fixed ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete , screwed for 25 mm bore dia. pipe or brass ferrule complete all as specified.
Demolition and breaking up drain pipes ( salt glazed ware, AC or Reinforced concrete/SWR ) set in cement mortar of 75mm/100mm dia bore and removal of unserviceable pipe from work site,all as directed.
Supply and fixed in repairs of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with necessary clamps complete all as specified.
Supply and fixed for 110mm dia PVC (SWR) branch piece, (single ‘Y‘) equal or unequal complete all as specified and as directed.
Supply and fixed for 110mm dia PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls complete all as directed.
Supply and fixed of PVC ( SWR) junction single , ( Single T) equal or unequal 110 mm bore with access door complete all as specified.
Supply and fixed in repairs vitreous China white Squatting pan ,'Orissa' pattern size 580 mm x 440 mm with integral footrests water closet) with 'P' or 'S' trap front or back inlet complete including lime concrete for bedding, connection to drain pipe and to flushing pipe , anti syphonage pipe etc complete all as specified.
Supply and fixed in repairs of Vitreous China bowl urinal flat back, size of 465x355x265 mm White ( minimum) including providing and fixing plugs, bedding the urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and providing grating and union for discharge pipe including 32mm bore PVC discharge pipe complete all as specified and as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but n exc 4 sqm each etc including removing material from work site complete all as specified and directed.
Taking down chowkats with shutter (without taking off shutter from the frame) n. exc 1.5 Sqm each etc including removing material from work site complete all as specified and directed.
Supply and fixing of pressed steel framed for door with one or more rebates including supply and fixing of necessary fixing lugs, hinges, lock strike plates, size of frame 125 X 60 mm, 1.6 mm thickness of sheet, complete all as specified and as directed.
Supply and fixing of 35mm thick 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rails and panel of 9mm BWP comercial ply or 12 mm thick veneered particle board with comercial veneering on both faces. The size of rail and style as per IS-1003 Part-I klin seasoned and chamicaly pressure treated complete all as specified and as directed.
Supply and fixing of 35mm thick factory made 2nd class hard wood gauged and skeleton shutter open rebated and prepared to receive glass , gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed.
Supply and fixing of 100 mm long medium weight, cold rolled stainless steel butt hinges cold rolled complete all as specified and directed.
Supply and fixing 150 mm size extruded aluminium anodised alloy handle , fabricated type complete all as directed.
Supply and fixing 150 mm size black jappen painted mild steel handle oval type complete all as specified.
Supply and fixing 200 mm size mild steel barrel tower bolts stove enamelled black with bright bolt etc. complete all as specified.
Supply and fixing 150 mm size aluminium anodised barrel tower bolts of extruded section complete all as specified.
Supply and fixing 250mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nutss , four on bolt plate and two on staple plate complete all as specified.
Material and labour for preparation of untreated new wooden surface of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint, (1 st quality) with a coat of pink primer all as specified and directed.
Supply and Fixing solid PVC door frame of size 50 mm X 47 mm made out of 5 mm wood grain printed PVC sheet reinforced with MS square tube supply & fixing in opening as per specification & drawing and as directed.
Supply and Fixing factory made solid panel PVC wood grain printed door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side as gap insert for top rails bottom rail, panelling of plain colour PVC sheet to be fitting in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing and as directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc.including removing of rubbished material from work site complete all as specified.
Material and labour for 20 mm thick rendering in two layers (first 10mm thick backing coata and then 10 mm thick finishing coat mixed with WPC) on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructionscomplete all as specified top surfaces finished even and fair without using extra cement complete all as specified. (Note: WPC shall be used on top surface and WPC shall be measured and paid separately)
Material and labour for rendering 5mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3 complete all as specified
Material and Labour for rendering 15 mm thick on other than fair / unfair faces of brick or concrete surfaces finishing surfaces even and fair without using extra cement in Cement mortar 1:6 all as specified and directed.
Supply only Integral liquid water proofing compound conforming to IS-2645-2003 complete all as specified.
Material and labour for preparation of new/untreated surfaces/ of walls and applying two coats of colour wash over a coat of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour fo preparation of new plastered or unplastered surafces of ceilings and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of new surfaces of walls and applying wall care white putty and sand papering surfaces to achieve smooth surfaces and applying two coats of acrylic based distemper over a coat of primer, white or tinted including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old surfaces of walls by complete removal of existing treatment and applying wall care white putty and sand papering surfaces to achieve smooth surfaces and applying two coats of acrylic based distemper over a coat of cement based primer, white or tinted including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of walls by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of colour wash on old decorated surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Supply and fixing in repair factory made steel window with side hung shutters including projecting type hinges with steel handles, and steel peg stay, fixing lugs complete with glazing bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Supply and fixing in repair factory made steel window with side hung shutters including projecting type hinges with steel handles, and steel peg stay, fixing lugs complete without glazing bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Supply and fixing of factory made steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or witthout glazing bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Supply and fixed mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290-Gde E-165 complete all as specified and directed.
Supply and fixing 3 mm thick (nominal) Sheet glass, ordinary quality , in squares, not exceeding 0.50 sqm each each pane fixed with oil putty complete all as specified.
Supply and fixing 3 mm thick (nominal) Sheet glass, ordinary quality , figured glass, pin head type and glazing with oil putty in squares n exc 0.50 sq.m. in each pane complete all as specified.
Supply and fixed stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixed in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over pre primed surfaces including cleaning / washing and preparation of surfaces complete all as specified.
Material and labour for preparation of old painted wooden /wood based materials surfaces of any description, not otherwise described, over 10 cm width or girth and painting one coat with synthetic enamel paint (1st quality) including cleaning, stopping and rubbing down and removing all dropings etc. all as directed.
Material and labour for preparation of old painted steel and iron surfaces of any description , not otherwise described,over 10 cm width or girth and painting one coat with synthetic enamel paint including cleaning, stopping and rubbing down and removing all drops etc. complete all as speciified.
Demolition of existing roof treatment complete of any description and in taking down existing tarfelt including tiles, lime concrete and screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50m and n. exc.100m including roughening of old concrete surface of roof, cleaning the surface by wire brushing to remove all loose dust etc complete all as specified and directed.
Material and labour for 10 mm thick screed bed or bedding layers in cement mortar (1:4) mixed with water proofing compound @ 200 ml per bag of cement or as per manufacturers instruction in order to maintain proper slope over existing roof surfaces finished even and smooth without using extra cement for receiving treatment complete all as specified and directed.
Material and labour for plain cement concrete type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregate, in roof kerbs or mud stops, rounded or cmamfered on edges complete all as specified.
Material and labour for water proofing treating to RCC roof with providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating Roof Guard in 4 coats of application:- (a) apply primer coat with primer @ 0.3 Kg /sqm, (b) Over primer coat apply water proofing fibre reinforcement a length of appox 1 Mtrs @ 0.75 kg/Sqm on flat surface and ensure that there is no bubbles of creases, overlapping of the fibre is minimum of 50 mm and allow this coat dry for a period of 2-6 hours depending on atmospheric condition. (c) Apply second coat of water proofing coat @ 0.75 Kg/Sqm. (d) Apply final coat of primer @ 0.08 kg/Sqm after seconf coat dried properly. (Note : Water proofing treatment work shall be carried out by applicator of manufacturer only duly approved by GE in writiing.
Demolition of Cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for including reinforced cut to facilitate demolition complete including removing demolished material from work site all as specified and directed.
Material and labour for reinforced Cement concretetype A-1 (1:1.5:3), 20 mm graded stone aggregate) as inin slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified..
Material and labour forf use and waste form work to sides of fins, louvers, fascia and similar work; vertical or to batter) surfaces fair finished complete all as specified.
M&L Mild steel bars ( TMT) 8mm dia. and over up to and including 10 mm dia. , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified.
Material and labour in repairs of Welded steel wire fabric Weight per square metre not exc. 4Kg/sqm fixed to wood or steel members complete all as specified.
Material and labour for preparation of new or previously untreated steel and iron surfaces of any description, not otherwise described ove 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
INTERNAL ELECTRIFICATION Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
Material & Labour for consealed type point wiring with 1.50 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable of working voltage 1100 volts grade conforming to IS-694 Pt I & II of 2000 drawn through and including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification), including provision of 1.5 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable as earth continuity conductor, connected to main switch / DBs or common earth dolly for one light / fan point / exhaust fan/bell point controlled by one 5 Amps one way switch complete all as specified and as directed . Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.79 here-in-before but for one socket out let 5/6 amps point on the independent board
All as per item No.79 above but One socket out let 5/6 amps point on the same board complete all as specified.
All as per item No.79 above but One light point controlled by two way switch 5/6 amps.
Material and labour wiring for 5/6 pin 6/16 Amp switch socket combination on independent boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FR earth wire and connecting to earth dolly and brass screws, washers etc. including cutting chases pinning in for concealed conduit wiring and making good of disturbed surface n exc 15 cm girth complete all as specified.
Supply and fixed switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply and fixed switch piano flush type, single pole , 6 Amps, two ways complete all as specified.
Supply and fixed socket 2 in 1, 5 Pin, 5/6 amps, any type complete all as specified and as directed.
Supply and fixed socket outlet 2 in 1, 5 Pin, 5/16 amps, multipurpose type complete all as specified and as directed.
Supply and fixed switch piano flush type, single pole , 15/16 Amps, one way complete all as specified.
Supply and fixed switch socket combination 2 and 3 pin , 5 / 6 Amps , multipurpose flush non shutter, non inter locking type white ivory finish with complete all as specified and as directed.
Supply and fixed switch socket combination 2 in 1 , 6 pin , 5 / 6 Amps and 15/16 Amps multipurpose flush non shutter, non inter locking type white ivory finish with complete all as specified and as directed.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply & fixed in repairs lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified.
Supply & fixed LED white glass Lamp 1 x 09 Watts, 230V Base-22 complete all as directed.
Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
Supply and fixing of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed.
Supply and fixing in repairs LED tube light fittings 1 x 9/10 watts energy efficient, 230 V incl 1x9/10 watt LED tube, surface / wall mounted LED batten with aluminium housing and integrated driver including holders, connector block etc. complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable all as specified and directed..
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false celing/ ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as directed.
Materials and labour for Sub main wiring with 2 runs of 6.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FRLS) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly, drawn through and including PVC rigid non- metallic PVC conduit / casing and capping ISI marked , medium garde of adequate size with all conduit / casing and capping accessories ISI marked as required complete all as specified and as directed including taking down old unserviceable / burnt / damaged one. [NOTE : Two run of sub main wiring cable along with one run of earth wire and one run of PVC Conduit / casing and capping shall be measured as one length]
Supply & fix sheet metal enclosure for 8 way Distribution Boards (DB’s), double door , single pole and neutral with 200 amps rated bus bar, including bus bar neutral link, earth bar and din rail, IP-43, IK-09 protection including gasket and door earthing suitable for fixing MCBs/isolators fixed on wall surface and making good the disturbed surfaces of wall and connecting up including taking down old unserviceable one including MCCB / MCB complete all as specified and as directed.
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed of sheet metal enclosure for 4 way Distribution Boards (DB’s), double door , single pole and neutral with 200 amps rated bus bar, including bus bar neutral link, earth bar and din rail, IP-43, IK-09 protection including gasket and door earthing suitable for fixing MCBs/isolators fixed on wall surface and making good the disturbed surfaces of wall and connecting up complete all as specified and as directed.
Supply and fixed in repairs MCB TPN 40 to 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 40-63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs new generation energy saving and environmental friendly long life LED security light fitting with 45 watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening including separate driver comportment with IP 66 protection & impart resistance of IKO7 with operating voltage range of 140V to 270 V olts, 120 lLumen per watt complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose and 32mm dia 1.5 mtr long bend to required shape complete all as specified.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 20 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
N K Construction
M/S PLABAN KUMAR GOPE
M/s. RAMPHAL GARG
L. B. SHARMA
M/S East India Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .