Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹29.0 L+₹3.0 L (11.4%)Rejected-AOC | 2 | Rejected-AOC L2 Rejected |
Tender Value
₹27.9 L
EMD Value
₹50,000
Closing Date
5 Apr 2023, 6:00 pmClosed
Executive Engineer
O/O The Executive Engineer PWD Electrical division Thiruvananthapuram
DEPOSIT-SITC of new USS at Govt. Analyst Laboratory, Thiruvananthapuram-SITC of new USS at Govt. Analyst Laboratory, Red Cross Road, Thiruvananthapuram-General Electrical Work (Retender)
2022_PWD_543989_4
EDT_ET_38_2022_23
Open Tender
Electrical Works
Item Rate
92 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
8 Jun 2023
25 Mar 2023
10 Apr 2023
25 Mar 2023
5 Apr 2023
25 Mar 2023
Amount
OD90439/2022-2023:Supply, conveyance, Installation, Testing and Commissioning of indoor type USS, 11KV/433V,50Hz,250 KVA,3Phase, Delta-Star,Vector DYN-11 Laser Scribed transformer with off circuit tapping from + 5% to -5% in step of 2.5%, changable off circuit by tap links provided, with WTI & LV terminals suitable for 2 runs of PVCA cable and HV terminals connected to 11KV, 26.3KA,630A Load break switch, with incoming suitable for XLPE cable,with HT HRC fuses, Master trip, copper busbar, out put connected to 11KV seal off bushings to the transformer. The Transformer shall conform to IS 11171/1985 re-affirmed in 1991. H.T. Portion:HT portion shall consists of: 1No. 630A, 26.30 kA load break switch suitable for 3 phase, 3wire, 50 Hz system with HT HRC fuses of appropriate rating with earth switch inter lock with main switch and mechanical ON/OFF indication Shunt trip coil for the remote operation of the Load Break Switch Necessary cast resin type CT & PT for metering. T.O.D Metering facilities. 3 Nos 30/5A (or suggested by KSEB)10 VA 0.2 s Class accuracy cast resin C.T. 1 No 3 Phase 3 limb 11 KV/110 V, 10 VA 0.2 accuracy class cast resin PT with protective fuses. 1 No. TOD Meter.(vector type 0.2s class) L.T. Portion.:The L.T. portion shall be provided Bus coupling /Cabling as per the direction of Engineer In charge with overload setting as per scheme . All inter connections from HT Load Break Switch to transformer and transformer to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the points of contacts. All internal earth connections are to be given as per standards. Necessary provision shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall be fabricated from 2.00mm CRCA sheet, having minimum height same as top level of incommer LT panel compling of IP 20 standards and shall be powder coated over a coat of Zinc chromate primer after seven tank processing and phosphatising. The USS shall be installed as per the directions at site.
OD90492/2022-2023: SITC of Out door type 630A, 11KV,21 KA, Triple pole, 50 Hz. 1 Way Motorised SF6 Gas Insulated double side Extensible type RMU Breaker and Vacuum Circuit Breaker with Cable bushing/box mounted type Over Current protection Transformer having ratio 60/30/1A-5P10,2.5VA and earth fault protection etc, including , conveyance, loading /unloading, erection, testing and commission's etc
OD100800/2022-2023:Supply and Fixing 75/5A 15 VA accuracy class 5P 10 protection CT (Tape wound)
OD113148/2022-2023:Supply and providing single pole over current earth fault relay [ IDMT and definite time characteristics ] giving connection as required
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
OD113149/2022-2023:Supply and fixing 250 x 250 x 150 size SMC Junction box with hinged door directly on wall or pole using required materials
OD100801/2022-2023:Supply and fixing following rating Surge Protection Devices (3P+N) ,Conforms to IEC 61643-11, Type 1+2(Protection against direct and indirect lightning surges) , Maximum Discharge Current - Imax up to 50 kA in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (L&T or Equivalent Make)
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD90504/2022-2023:Supply & fixing 400/5 A, 15 VA, accuracy class 1, Resin Cast Metering CT
OD90505/2022-2023:Supply & fixing 125/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT
OD90514/2022-2023:Supply and fixing Multifunction meter to read:W, Wh, PF or VA, Vah, PF or VAR, VARh, PF ? 3 ph accuracy class 1
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.5.34:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
OD92781/2022-2023: Supply & laying of 3 core 300 sqm11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 300 sq mm
OD92782/2022-2023: Supply, laying and clamping of 1 no. 3 core 300 sqm 11 KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with late
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
10.2.4:Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
90.12.10.7:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation120/102.5 mm or nearest size
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.7:Supply and providing copper earth bus in the panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
OD100461/2022-2023:Supply and fixing LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia Blue colours
OD100462/2022-2023:Supply and fixing LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia Red, Green, Black, Yellow, Orange colours
OD100558/2022-2023:Supply and fixing 3 Pole Capacitor duty contactors for switching capacitor banks 20 kVAR with AC Coil with Auxiliary contact Block 1 NO + 1 NC.
OD100549/2022-2023:Supply and fixing 3 Pole Capacitor duty contactors for switching capacitor banks 7.5 - 10 kVAR with AC Coil with Auxiliary contact Block 1 NO + 1 NC.
OD100550/2022-2023:Supply and fixing 3 Pole Capacitor duty contactors for switching capacitor banks 4 - 7 kVAR with AC Coil with Auxiliary contact Block 1 NO + 1 NC.
OD92970/2022-2023:Supply and fixing 8 stage 440 / 110 V 5A/1A , Intelligent Power Factor Controllers (IPFC)
90.14.24.55:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
90.14.24.58:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
90.14.24.61:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel with block reactor.
OD92076/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 10 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.<br>
OD92077/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.5 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.<br>
OD92078/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 4 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.<br>
OD92079/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 6 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.<br>
OD92080/2022-2023: Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.<br>
OD92139/2022-2023: Supply, laying and clamping of 1 no. PVC insulated 2 Core,1.5 sq.mm, armoured copper FRLSH power cable, 1.1 KV grade ( Red Colour) using clamps noted along with the cables, spacing of clamps not exceeding 40 cms, making good the damages , colour washing etc. as required
OD91565/2022-2023:MANUAL CALL POINT:- Supply Installation, Testing and Commissioning of Manual Call Points of break glass type with hammer and chain.
OD100843/2022-2023:Supply and fixing Flush head Actuator - Green with legend 'satart, (Contact - 1 NC)
OD100844/2022-2023:Supply and fixing Flush head Actuator - Red with legend 'stop', (Contact - 1 NC)
OD113154/2022-2023:Supply and providing 150 mm panel mounting cooling fan with fresh air grill as required
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD113158/2022-2023:Supply, fixing and giving connection of 40 / 50 / 63 A four pole, 415 volts, MCB in the existing DB
OD113195/2022-2023:Supply and fixing 200A 4 pole 25 KA MCCB with over load setting up to 80 % and adjustable short circuit setting with extended terminal on both side, giving connection as required
OD113196/2022-2023:Supply and fixing 160A 4 pole 25 KA MCCB with over load setting up to 80 % and adjustable short circuit setting with extended terminal on both side, giving connection as required
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
OD113217/2022-2023:Supply and fixing 400 A 4 pole 35 KA with microprocessor setting up to 50 %, adjustable short circuit setting, inbuilt ground fault protection, neutral over load protection with time setting with extended terminal on both side, giving connection as required
OD113218/2022-2023:Supply and fixing 400 A 4 pole 35 KA with microprocessor setting up to 50 % and adjustable short circuit setting with extended terminal on both side, giving connection as required
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
OD92153/2022-2023:Supply and fixing of Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating 200/250A (8 pcs) and giving connection etc as required.
OD92785/2022-2023:Supply and fixing of 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet on the floor with using synthetic a 2.00 mm thick, 3.3 kV, Synthetic adhesive as required.
OD92786/2022-2023:Supply and fixing of 2.50 mm thick, 11kV, Synthetic elastromeric fire retardant insulating sheet on the floor with using synthetic a 2.5 mm thick, 11 kV, Synthetic adhesive as required.
OD100824/2022-2023:Supply and fixing Cable alley, 100 x 40 mm aluminium anodised legend plates.
OD100825/2022-2023:Supply and fixing Bus bar chamber, 100 x 40 mm aluminium anodised legend plates
OD100826/2022-2023:Supply and fixing Danger 415 V, 150 x 100 mm aluminium anodised legend
OD91564/2022-2023:Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 3.6 metre long etc. with charcoal/ coke and salt as required.
90.16.3.11:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 3 mm copper strip
OD92691/2022-2023:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
OD92694/2022-2023: Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. as per IS 2546<br>
OD92761/2022-2023:Supply and installation of ABC type fire extinguisher 5kg capacity consisting of M.S cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30cm long high pressure discharge hose, nozzle etc and fixed on wall with using suitable size anchor fastener/screw with all accessories as required .
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD113156/2022-2023:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
OD97125/2022-2023:Supply Conveyance, installation , testing and commissioning of exhaust fans of size 380 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD96232/2022-2023:Painting letters or figures of the follwing sizes with enamel paint as identfication mark to SB, DB, panel board etc as required
OD113157/2022-2023:Charges for engaging one wire-man and helper for dismantling the existing Electrical installation, distribution board line, cleaning, colour washing etc as required
OD113219/2022-2023:Copying charges of Electrical/fire Drawing per A 3 sheet additional copies
OD113220/2022-2023:Charges for preparation of Electrical/fire Drawing per A 3 sheet first copy
DSK ELECTRIC POWER
Bidder Name
D SURESH
DSK ELECTRIC POWER
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .