Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.1 LAccepted-AOC TC 52 671 1 VINAYAKA NAGAR NEERAMANKARA PAPPANAMCODE THIRUVANANTHAPURAM KERALA 695018 | THIRUVANANTHAPURAM | KERALA | 695018 | 1 | Accepted-AOC Lowest Quoted | |
| 2 | 2₹10.3 L+₹14,875 (1.46%)Rejected-AOC | 2 | Rejected-AOC Second Lowest Quoted |
Tender Value
₹9.9 L
EMD Value
₹24,800
Closing Date
25 Oct 2019, 5:00 pmClosed
MANAGING DIRECTOR
KTDC- CORPORATE OFFICE, MASCOT SQUARE, PMG, TRIVANDRUM - 695033
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF THREE PHASE 3 TR, SINGLE PHASE 2 TR AND 1 TR SPLIT AIR CONDITIONER UNITS AT KTDC - TAMARIND EASY HOTEL, ALAPPUZHA
2019_KTDC_303557_1
AE1/KTDC.EW/250/TEH-ALP-AC/18
Open Tender
Electrical Works
Item Rate
30 days
KTDC - TAMARIND EASY HOTEL, KALAPPURA, ALAPPUZHA
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,360
online
₹24,800
2 Jun 2020
5 Oct 2019
30 Oct 2019
5 Oct 2019
25 Oct 2019
5 Oct 2019
5 Oct 2019 - 24 Oct 2019
Amount
AIR CONDITIONING WORKS
Supply,installation, testing and commissioning of following Split type High wall mounted Cordless remote 3 star or above rated inverter copper coil type, Air Conditioner unit of following ratings with stabilizer and all fixing accessories including fixing of Indoor & outdoor units, initial gas charging as per manufacturer standards, giving power connection to nearest Power plug point / MCS, connecting indoor and outdoor units using hard drawn copper refrigerant pipes insulated with nitrile rubber or equivalent material of approximately 3 mtrs, PVC insulated flexible copper cable of approximately 3 meters as per original manufacturer standards, necessary drain water line using 20mm PVC pipe approximately 3 mtrs. Necessary opening on wall shall be made for drawing refrigerant / power / drain lines and shall be restored to normal using cement plastering. (Drain pipe line shall be properly fixed and clamped to line and level as per the direction of site engineer in charge). Make: Blue Star/voltas/LG/Lloyd or equivalent
1 TR Capacity working on Single Phase 230 V, 50 Hz +/-1% AC supply.
2 TR Capacity, rated working on Single Phase 230 V, 50 Hz +/-1% AC supply.
3 TR Capacity working on three Phase 415 V, 50 Hz +/-1% AC supply.
Supply & providing additional refrigerant lines (Liquid and Discharge) using hard drawn copper pipe of the sizes recommended by the manufacturer including suitable thickness nitrile rubber thermal insulation of good quality to extend the refrigerant gas connection till outdoor unit as required at site.
For 1 TR AC
For 2 TR AC
For 3 TR AC
Supply of 20mm,1.5mm thick drain piping of good quality ISI marked suitable dia to extend water drain connection till nearest silt terminal as required as site. Make: Supreme/zoloto
Supply & drawing additional control cable of required size as recommended by the manufacturer between Indoor and Outdoor of AC units. Make: Finolex/Havells/RR/Polycab
INTIMATE REFRIGERATION AND AIR CONDITIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .