| 1.00Ceiling Work | ||||||
| 1.01 | 26.26.2
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners,6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. | 195 | sqm | 2,060.72 ₹4,01,840.4 Lowest | 12,060.72 ₹23,51,840.4 | 12,060.72 ₹23,51,840.4 |
| 1.02 | 26.8 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size under deck on ceiling surface, complying with ISO 4898:2008 &ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per
the direction of Engineer-in-Charge. | 195 | sqm | 1,079.48 ₹2,10,498.6 Lowest | 1,079.48 ₹2,10,498.6 Lowest | 1,079.48 ₹2,10,498.6 Lowest |
| 1.03 | 13.80
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 710.12 | sqm | 144.97 ₹1,02,946.82 Lowest | 144.97 ₹1,02,946.82 Lowest | 144.97 ₹1,02,946.82 Lowest |
| 1.04 | 13.85.3
Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre | 710.12 | sqm | 75.46 ₹53,586.03 Lowest | 75.46 ₹53,586.03 Lowest | 75.46 ₹53,586.03 Lowest |
| 1.05 | 13.46.1
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | 710.12 | sqm | 195.31 ₹1,38,694.51 Lowest | 195.31 ₹1,38,694.51 Lowest | 195.31 ₹1,38,694.51 Lowest |
| 1.06 | 13.70
Floor polishing on masonry or concrete floors with was polish of approved brand and manufacture . | 342.9 | sqm | 93.19 ₹31,954.85 Lowest | 93.19 ₹31,954.85 Lowest | 193.19 ₹66,244.85 |
Tender Value
₹20 L
Closing Date
18 Oct 2025, 5:00 pmClosed
BaijuT P
Forest Industries Travancore Limited , Aluva
Auditorium Construction
2025_FITL_808075_1
FIT/CP-80/2025-26
Open Tender
Civil Works - Roads
Item Rate
365 days
KOTTAKKAL MUNICIPALITY
Refer Tender document
8 documents required · 8 mandatory
₹2,950
Exempted
Forest Industries Travancore Limited Thaikkattukar
23 Oct 2025
10 Oct 2025
20 Oct 2025
10 Oct 2025
18 Oct 2025
10 Oct 2025
10 Oct 2025 - 15 Oct 2025
15 Oct 2025
Amount
Ceiling Work
26.26.2 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners,6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.
26.8 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size under deck on ceiling surface, complying with ISO 4898:2008 &ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.85.3 Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.70 Floor polishing on masonry or concrete floors with was polish of approved brand and manufacture .
RedRock Developers (BID ID -2396425)
Musthafa KT (BID ID -2396471)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_1347291.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .