Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC 1ST FLOOR NO 14 ANUSUYA STREET RANGARAJAPURAM KODAMBAKKAM CHENNAI 600 024 | CHENNAI | CHENNAI | TAMIL NADU | 600024 | ₹1.1 Cr | 1 | Accepted-AOC L1 TENDERER |
| 2 | 2₹1.1 CrRejected-AOC | ₹1.1 Cr | 2 | Rejected-AOC L2 TENDERER |
| 3 | 3₹1.2 CrRejected-AOC 6 11 VEDHA NAGAR MEDU FIRST STREET NEAR CHINMAYA VIDAYALAYA SCHOOL CHINMAYA NAGAR STAGE II VIRUGAMBAKKAM CHENNAI 600 092 | CHENNAI | TAMIL NADU | 600092 | ₹1.2 Cr | 3 | Rejected-AOC L3 TENDERER |
| Sl No | Description | Qty | Unit | Kalaichandran&Co L3 | Sri Rajeswari Construction L2 | ADPURA TECHNOLOGIES PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00Providing dedicated sewer main to Tamil Nadu Housing Board, Commercial / Residential Complex in Ashok Pillar Road, Ashok Nagar in Depot 135, Area X | ||||||
| 2.00 | Hire charges for power driller for cutting asphaltic / Cement concrete road surface | 1,675 | hrs | 500 ₹8.4 L | 650 ₹10.9 L | 400 ₹6.7 L |
| 3.00Supplying & Laying C.I. SPUN PIPES AS PER IS 1536/2001 - 200mm dia - LA class including earthwork excavation for trenches in hard stiff clay, blackcotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10 m and initial lift of 2m carting the pipes from any of the Board‟s Stores to the site of work lowering into the trenches and aligning, etc.,@ 1,5m depth | ||||||
| 4.00 | Highways & Bus Route | 750 | mtr | 6,750 ₹50.6 L | 5,500 ₹41.3 L | 6,900 ₹51.8 L |
| 5.00 | Non-Bus Route | 200 | mtr | 6,500 ₹13 L | 5,500 ₹11 L | 6,700 ₹13.4 L |
| 6.00Supplying, conveying and fixing following CI specials like Tee, Bends and Tapers as per IS 1538 including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc. at any depth. | ||||||
| 7.00 | 200 mm D/Soc CI 90o Bend" | 7 | Nos | 10,000 ₹70,000 | 7,500 ₹52,500 | 6,000 ₹42,000 |
| 8.00 | 200 mm D/Soc CI 45o Bend" | 3 | Nos | 10,000 ₹30,000 | 7,000 ₹21,000 | 3,000 ₹9,000 |
| 9.00 | 200 mm D/Soc CI 22.5o Bend" | 2 | Nos | 10,000 ₹20,000 | 6,500 ₹13,000 | 1,800 ₹3,600 |
| 10.00 | 200 mm dia CI Non-Return Valve | 1 | Nos | 15,000 ₹15,000 | 28,000 ₹28,000 | 15,000 ₹15,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹64,100
Closing Date
20 Jan 2026, 3:00 pmClosed
Superintending Engineer (C and M)
Office of Superintending Engineer, Contracts and Monitoring, 4th Floor, CMWSS Board, No.1, Pumping Station Road, Chintadripet, Chennai 600 002
Providing dedicated sewer main to Tamil Nadu Housing Board, Commercial and Residential Complex in Ashok Pillar Road, Ashok Nagar in Depot 135 Area X
2025_CMWSS_633342_1
CNT/SEW/DEP/3685A/2025-26
Open Tender
Civil Works
45 days
Chennai
Class IA
5 documents required · 5 mandatory
₹0
₹64,100
11 Mar 2026
18 Dec 2025
21 Jan 2026
18 Dec 2025
20 Jan 2026
24 Dec 2025
Hire charges for power driller for cutting asphaltic / Cement concrete road surface
Supplying & Laying C.I. SPUN PIPES AS PER IS 1536/2001 - 200mm dia - LA class including earthwork excavation for trenches in hard stiff clay, blackcotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10 m and initial lift of 2m carting the pipes from any of the Board‟s Stores to the site of work lowering into the trenches and aligning, etc.,@ 1,5m depth
Highways & Bus Route
Non-Bus Route
Specials for Discharge at SPS
Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing "METRO WATER" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites
Testing of M.S./C.I./P.V.C./D.I pipes with hydraulic testing equipment by filling with water(including cost of water","@ Rs.60/KL) and testing to recommended pressure in convenient stetches and attending the bursts if any occured during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for 200 mm dia pipe
Cement concrete 1:2:4 using 20mm gauge hard broken stone jelly for PCC works excluding centering, shuttering, compacting, curing, finishing etc complete.
For Bed Block
Providing thrust blocks with Plain Cement Concrete in 1:3:6 with 40mm HBG for the CI pumping main including the cost of shuttering, compaction, curing etc. complete.
Providing Wet mix macadam including premixing the material with water at OMC in mechanical mix plant carriage and laying in uniform layers and compacting etc.Complete as per clause 406 of MORT&H specifications
Cement concrete 1:3:6 using Crushed stone sand (Msand) and 12 to 20mm gauge hard broken stone jelly for plain cement concrete works including laying, compacting, curing, etc., complete.
Disposal of surplus earth
Construction of water meter Chamber in M25 with 12mm thick outside plastering and 20 mm thick inside plastering in CM 1:3 proportion, RCC cover slab in CC 1:2:4 proportion using 20 mm jelly, chamber foundation and bed block in PCC 1:3:6 proportion using 40 mm jelly including cost of reinforcement and labour charges,earth work excavation,sand filling,refilling and disposal of surplus earth ,fixing CI steps, etc. complete and including providing and fixing L.S cover and frame of size 60cmx60cm including necessary masonry work and plastering etc complete as directed by the Engineer at site as per specification of sizeas mentioned below
Making Rubber joints for C.I./D.I pipes – Labour only -200mm dia
ElectroMagnetic Flow meter
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.
Supply, conveying and fixing CI D/F pipes as per IS:1537 and CI SS/DF specials like Tee, Bends ,Tapers and Tailpieces as per IS 1538 including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc. at any depth.
Topographic Survey of assets and utilities
As built survey for every sewage and water pipeline and other assets must be done using DGPS based RTK method by transferring the coordinates from the nearest Static GCP of CMWSSB. Where there are signal interruptions for the RTK method, Total Station can be used. The coordinates from the static GCP shall be transferred to the Total Station by RTK method and the co- ordinates of the assets can then be captured by Total Station. All the features, attributes of all the assets, utilities captured shall be Geo referenced as per standard Coordinate reference system (WGS 84 UTM Zone 44N). The final base map with assets and utilities shall be furnished in (.shp) format. The geo referenced assets and utilities along with the attributes (as specified by the GIS Wing, CMWSSB) shall be converted into proper geo database (FGDB / PGDB)with the attributes. One set Hard and Soft Copy of all the CMWSSB assets and utility has to be prepared category wise network wise in A0 Print for verification in a print scale of 1:1000 in A0 plot, with standard legends in international and NUIS standards and should be legible and three sets of final Hard Copy in A0 print.
(a) For the Underground / Surface Assets along the roads for the distance ranging for <2 km For TBM Available
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_757769.xls
BOQ • 0.44 MB
CHECK_LIST_3685A.pdf
Tender Documents • 0.26 MB
Download all tender documents and submit your bid