Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.5 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹25.9 L+₹1.1 L (4.31%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹30.6 L+₹5.8 L (23.3%)Rejected-Finance 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
25 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR MAINT OF SUMMER AND WINTER APPLIANCES IN THE AREA OF AGE EM UNDER GE (EAST) LUCKNOW.
2020_MES_343346_2
GE/E/LKO/T-06 OF 2020-21
Open Tender
Miscellaneous Services
Item Rate
270 days
Lucknow Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE EAST LUCKNOW
₹66,000
Yes
30 Jun 2020
11 Jun 2020
26 Jun 2020
11 Jun 2020
25 Jun 2020
13 Jun 2020
60 days
Amount
Taking down the Geyser of any make and size horizontal or vertical from Site for repairs/overhauling/replacement of unserviceable parts including replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line all as specified and directed. Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers." for repairs/overhauling/replacement of unserviceable parts including replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line all as specified and directed. Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers.
Supply and fix in replacement unserviceable heating element 2.0 KW of Geyser (ISI marked) big triangle in shape with provn for fixing cable through screw of any make and type all as specified and directed. (Make: Racold/ Bajaj/Usha/Theeta)
Supply and fix in replacement unserviceable heating element 2.0 KW of Geyser (ISI marked) small triangle in shape with provn for fixing cable through screw of any make and type all as specified and directed. (Make: Racold/ Bajaj/Usha/Theeta)
Supply and fix in replacement unserviceable heating element 2.0 KW of Geyser (ISI marked) circular triangle in shape with provn for fixing cable through screw of any make and type all as specified and directed. (Make: Racold/ Bajaj/Usha/Theeta)
Supply and fix in replacement thermostat(ISI Marked) suitable for any type, and capacity of geyser all as specified and directed. (Make: Racold/ Bajaj/Usha)
Supply and fix in replacement unserviceable indicating lamps red and green colour for Geysers any make all as specified and directed.
Supply and replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasket with bolts, nuts, washers, screws of packing suitable for any type and make of geyser all as specified and directed. (Make: Racold/ Bajaj/Usha)
M & L, repairng of leakage of inner copper/steel tank of any type /capacity and make of Geyser by brazing including necessary denting, etc all as specified and directed.
Supply and replacement of unserviceable plug top 3 pin 15 Amp all as specified and directed. Make- Anchor/ SSK .
Supply and replacement of unserviceable 3 core copper flexible round cable 40/0.0076 size all as specified and directed. Make Seiko/ Plaza/ Finolex/ Anchor/ Havelles.
S & F, Stainless steel inner tank 25 Ltrs capacity as per existing gauge for Geysers all as specified and directed. (Make: Racold/ Venus)
S & F, Stainless steel inner tank 35 to 50 Ltrs capacity as per existing gauge for Geysers all as specified and directed. (Make: Racold/ Venus)
S & F, 450mm long copper connection complete & both side nut with rubber washer suitable for any capacity Geyser all as specified and directed .
S & F, 600mm long copper connection with both side nut & rubber washer suitable for any capacity Geyser all as specified and directed .
S & F, MCB SP 5 to 32 Amps, 240 Volts, breaking capacity 10 kA 'C' curve all as specified and directed.
S&F, industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall incl all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F, metallic top suitable for 20 Amp capacity plug & socket all as specified and directed.
S&F, metallic plug base suitable for 20 Amp capacity plug & socket all as specified and directed.
S & F, Switch socket combination 5 pin 15 Amps multipurpose type all as specified and directed.
M&L, painting of outer tank of Geyser with applying two coats of white synthetic enamel paint (Asian/Berger/Nerolac) including writting MES No. with black paint all as specified and directed .
S&F, in replacement of brass Safety Valve heavy duty ISI marked of Geyser suitable for 15 mm bore of pipe all as specified and directed.
S & F, 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
S & F, 600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
Taking down Ceiling fan/Exhaust fan any size any make, sealing cable ends, dismantling blades in case of ceiling fan and removing fan and blades to E/M store yard II for repair & hanging / fixing of the same after repair and connecting up all as specified and directed.
Repair and overhauling of Ceiling fan/ Exhaust fan/ Cabin fan/ Wall mounting fan/ Table fan/ Pedastal fan of any size by oiling/ greasing and reassembling the fan with new split pin, check nut, locking nut, washer, holder clip & connector. Testing and refixing of same fan shall be made to the entire satisfaction of Engineer-in-charge. Note: Repair work will be carried out at MES workshop/at site/ Users Residence as directed. Material required (Ball bearing and Condenser) for replacement of items will be measured and paid separately.
M&L, replacement of ball bearing of size 6201/6202/6203 all as specified and directed. Make - NBC/TATA/SKF
S&F, Capacitor 2.5 MFd for ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any Sweep all as specified and directed. Make:- Epcos/Usha
S&F, Capacitor 4 MFd for exhaust fan of size 450 mm/380 mm all as specified and directed. Make - USHA / EPCOS.
M&L, for replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size) suitable for 1200/1400 mm sweep ceiling fan all as specified and directed. Make - BAJAJ/USHA/ORIENT/ANCHOR.
Rewinding of Ceiling/ Exhaust/ Cabin fans and pedestal fans comprising of followings: a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately). c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 Mtr length. d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction of the Engr-in-Charge. Note: Rewinding shall be carried out in Yard No II, Painting of Fans deemed to be include in respective Item. 28.01 Ceiling fan of 1200 mm Sweep
Ceiling fan of 1400 mm Sweep
Exhaust fan 450 mm (18") to 600 mm (24") Sweep
Exhaust fan 380 mm (15") Sweep
Exhaust fan 300 mm (12") Sweep
Exhaust fan 230 mm (9") Sweep
Cabin fan 400 mm Sweep
Supply and fixing blade set (set of three) for any type/make of ceiling fan 1200 mm Sweep all as specified and directed.
Supply and fixing blade set (set of three) for any type/make of ceiling fan 1400 mm Sweep all as Specified and directed
S&F, Blade Set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan all as Specified and directed.
S&F, Blade Set with frame & four legs of fan with coupling for 380 mm (15") Sweep exhaust fan all as Specified and directed.
S&F, Blade Set with frame & four legs of fan with coupling for 300 mm (12") Sweep exhaust fan all as Specified and directed.
S&F, Blade Set with frame & four legs of fan with coupling for 230 mm (9") Sweep exhaust fan all as Specified and directed.
S&F, Blade set of cabin fan suitable for 400 mm sweep all as specified and directed.
S&F, Twisted twin core flexible copper cable of size 23/0.0076 all as specified and directed. Make - Seiko/Paragon/Finolex/Havells/Anchor.
M &L, Spray painting of fan with one coat of super enamel white paint (Berger/Asian/Nerolac) after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint all as specified and directed.
M&L, replacement of unserviceable hanging clamp for ceiling fan of any type complete with rubber reel, split pin, bolts, nut and washer all as specified and directed.
M&L, replacement of worn out/defective roter shaft of ceiling fan, exhaust fan, cabin fan of any make and size all as specified and directed.
S&F, ceiling fan canopy set of two all as specified and directed.
M&L for disconnection of electric supply and water supply pipe line of solar water heater/ collector plates of any size from site for repair/ overhauling/ replacement of unserviceable parts incl nut and bolts with washers, heating element and refixing the same in serviceable condition after assembling , testing and re connecting the electrical and water supply line all as specified and directed.
S&F in replacement of heating element 3 KW, suitable for solar water heater(ISI marked) all as specified and directed. Make:- Dass Pass, Rasmi, Theeta
S&F in replacement of heating element 4 KW, suitable for solar water heater(ISI marked) all as specified and directed. Make:- Dass Pass, Rasmi, Theeta
S&F in replacement of heating element 6 KW, suitable for solar water heater(ISI marked) all as specified and directed. Make:- Dass Pass, Rasmi, Theeta
M&L for replacement of old unserviceable collector glass panel with heating resistant glass panel of size 2.08 Mtr x 1.01 Mtr of thickness not less than 8 mm including cleaning of broken glass all as specified and directed. Make-TATA/V Gaurd / Microtech.
M&L for replacement of old unserviceable collector panel used for solar water heater based on in directed transfer of heat of capacity 100 LPD of all as specified and directed. Make-TATA/V Gaurd / Microtech.
M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tank including removal of old unserviceable heating element all as specified and directed.
M&L for welding work of rusted portion of complete set of collector panel including metal/ GI pipe where necessary all as specified and directed.
Ajanta Motor Store
HS ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .