Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.7 LAccepted-AOC 404 ANKUSH PLAZA TEKA NAKA CHOWK KAMPTEE ROAD NAGPUR 440017 | NAGPUR | MAHARASHTRA | 440017 | L-1 | Accepted-AOC as per Tender Committee recommendation | |
| 2 | Rejected-Technical B TYPE COLONY CHIRIMIRI POST GODDDRIPARA DISTRICT M C B C G PIN 497553 | KOREA | CHHATTISGARH | 497553 | - | Rejected-Technical as per recommendation of tender committee | |
| 3 | Rejected-Technical | - | Rejected-Technical as per recommendation of tender committee |
Tender Value
₹8.7 L
EMD Value
₹10,900
Closing Date
21 May 2024, 6:00 pmClosed
Staff Officer Civil, CHIRIMIRI AREA
Office of Staff Officer Civil, Chirimiri Area
Roof treatment with APP (Atactic polypropylene polymer) of 12 No B Type and 8 No MQ at teachers colony of Chirimiri UG Mine of Chirimiri Sub Area.
2024_SECL_307747_1
SECL/CHRM/Dy. GMC/24-25/e-Tender/07 Dt. 09.05.2024
Open Tender
Civil Works - Buildings
Item Rate
30 days
Chirimiri Area
refer to NIT
3 documents required · 3 mandatory
₹10,900
28 Aug 2024
9 May 2024
24 May 2024
9 May 2024
21 May 2024
10 May 2024
10 May 2024 - 18 May 2024
Amount
Item Description
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.870.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemicalparameters of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: 3 mm thick
Total impact of GST for the purpose of CTC
Narendra Kumar Pandey
PANNA LAL KUMAR
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .