Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC MISSION HOSPITAL CHOWK KEDARPUR AMBIKAPUR DIST SURGUJA CG 497001 | SURGUJA | CHHATTISGARH | 497001 | ₹44.1 L | L1 | Accepted-AOC L1 |
Tender Value
₹56.5 L
EMD Value
₹70,700
Closing Date
29 Jul 2024, 5:00 pmClosed
Staff Officer ENM
Office of the General Manager SECL Baikunthpur Area
Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day to Day Various Electrical Maintenance Jobs in Residential Quarters under Area Head Quarter, Churcha Mine (RO), Jhilimili Sub Area and Katkona Sub Area of Baikunthpur
2024_SECL_312140_1
SECL/GM/BKP/ENM/eTender/24-25/ 10
Open Tender
Civil Works - Others
Item Rate
365 days
Baikunthpur
As per NIT
9 documents required · 9 mandatory
₹70,700
23 Jan 2025
8 Jul 2024
30 Jul 2024
9 Jul 2024
29 Jul 2024
9 Jul 2024
9 Jul 2024 - 17 Jul 2024
Amount
Item Description/ Heading : (A) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day-to-Day Various Electrical Maintenance Jobs in Residential Quarters under Area Head Quarter, Rampur Colony and Rescue Colony under the control of Area Head Quarter, Baikunthpur Area. (B) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day-to-Day Various Electrical Maintenance Jobs in Residential Quarters under Churcha Mine (RO) of Baikunthpur Area. (C) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day-to-Day Various Electrical Maintenance Jobs in Residential Quarters under Pandavpara Colony of Jhilimili Sub Area, Baikunthpur Area. (D) Comprehensive Annual Maintenance Contract for the period of 365 Days for day-to-day various Electrical Maintenance Jobs in Residential Quarter of Katkona Sub Area of Baikunthpur Area.
(A) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day-to-Day Various Electrical Maintenance Jobs in Residential Quarters under Area Head Quarter, Rampur Colony and Rescue Colony under the control of Area Head Quarter, Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A
(b) Group B
(c) Group C
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm
(b) 3x 2.5 sq mm
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep
(a) 150 mm X 75 mm X 60 mm deep
(b) 150 mm X150 mm X 60 mm deep
(c) 180 mm X100 mm X 60 mm deep
(d) 200 mm X125 mm X 60 mm deep
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch
(b) 2 Way 5/6 A switch
(c) 15/16 A switch
(d) 3 Pin 5/6 A Socket Outlet
(e) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
(f) Bell push, piano type ISI marked
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral
(b) Double Pole
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each
(B) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day to Day Various Electrical Maintenance Jobs in Residential Quarters under Churcha Mine (RO) of Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A
(b) Group B
(c) Group C
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm
(b) 3x 2.5 sq mm
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep
(a) 150 mm X 75 mm X 60 mm deep
(b) 150 mm X150 mm X 60 mm deep
(c) 180 mm X100 mm X 60 mm deep
(d) 200 mm X125 mm X 60 mm deep
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch
(b) 2 Way 5/6 A switch
(c) 15/16 A switch
(d) 3 Pin 5/6 A Socket Outlet
(e) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
(f) Bell push, piano type ISI marked
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral
(b) Double Pole
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each
(C) Comprehensive Annual Maintenance Contract (CAMC) for the period of 365 Days for Day-to-Day Various Electrical Maintenance Jobs in Residential Quarters under Pandavpara Colony of Jhilimili Sub Area, Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A
(b) Group B
(c) Group C
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm
(b) 3x 2.5 sq mm
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep
(a) 150 mm X 75 mm X 60 mm deep
(b) 150 mm X150 mm X 60 mm deep
(c) 180 mm X100 mm X 60 mm deep
(d) 200 mm X125 mm X 60 mm deep
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch
(b) 2 Way 5/6 A switch
(c) 15/16 A switch
(d) 3 Pin 5/6 A Socket Outlet
(e) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
(f) Bell push, piano type ISI marked
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral
(b) Double Pole
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each
(D) Comprehensive Annual Maintenance Contract for the period of 365 Days for day-to-day various Electrical Maintenance Jobs in Residential Quarter of Katkona Sub Area of Baikunthpur Area. - 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A
(b) Group B
(c) Group C
2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2X2.5 sq.mm+1X2.5 sq. mm earth wire)
3. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
4. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (a) 2 x 1.5 sq mm
(b) 3x 2.5 sq mm
5. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 MM
6. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. (a) 100 mm X 100 mm X 60 mm deep
(a) 150 mm X 75 mm X 60 mm deep
(b) 150 mm X150 mm X 60 mm deep
(c) 180 mm X100 mm X 60 mm deep
(d) 200 mm X125 mm X 60 mm deep
7. Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required. (a) 5/6 A switch
(b) 15/16 A switch
(c) 3 Pin 5/6 A Socket Outlet
(d) 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
(e) Bell push, piano type ISI marked
8. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
9. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
10. Supplying and fixing brass batten/ angle holder including connection etc. as required.
11. Supplying and fixing 5 A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole and neutral
(b) Double Pole
12. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps
13. Supplying Lying , Drawing and connection of 2x6 sq mm PVC Aluminium Service Cable along with support of GI Wire(6swg) along with Connection on both side (From Pole to Main Switch of Quarter)
14. Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
15. Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.
16. Cleaning , Decarbonising and re-connection of existing Service Cable Connection From Pole to Main Switch of Quarter each
Total impact of GST for the purpose of CTC
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .