Executive Engineer
Jal Shakti Division Shahpur
Construction of RCC Main over head storage tanks of 20000 ltrs capacity with 8mtrs staging height other civil works and retaining structure etc
2020_HPIPH_37065_1
SHP-KNG15-754/2020-874-923 dt 11/5/2020
Open Tender
Civil Works
Lump-sum
180 days
Shahpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹250
Executive Engineer
₹17,770
Yes
29 Sept 2020
11 May 2020
26 May 2020
11 May 2020
26 May 2020
11 May 2020
11 May 2020 - 26 May 2020
Amount
Design and Construction of RCC Main over head storage tanks of 20,000 ltrs. capacity with 8 mtrs staging height, including cost of excavation, site development cost of construction material , necessary arrangement of inlet,outlet, over flow & scour pipe alongwith sluice valves , & other fixtures & fitting, and carriage of meterial within all leads and lifts. ( The design and Drawing shall be got approved from competent authority before execution )
Inlet pipe shall be provided by the department, however the Contractor / Firm shall have to make arrangements for connection the same with the tank with in all leads and lifts.
Providing and fixing of atleast 1 number manhole with CI cover 500 milimeter internal dia meter total weight of cover and frame to be not less than 110 Kg. ( medium duty ) the weight of cover and frame to be 56 Kg. each.
Cast iron ventilating pipe 150 milimeter dia with cowl and mosquito proof cover of sufficient length and lightening conductor as per site shall be provided by the contractor/ firm.
RCC sprial stairs of 75 centimeter wide including railing of G.I pipe 40 milimeter dia ( midium class) supported on mild steel angle iron 40x40x5 ,o;o,eter pf jeogjt 90 centimeter from the ground level of the reservior to the top of the bottom ring beam and steel stairs from top of bottom ring beams to manehole to base of resvior.
All inspection gallery of minimum width 75 centimeter shall be provided around the tank at the bottom ring beam level along with railing of G.I. pipe of suitable dia supported on mild steel angle iron of 40x40x5 milimeter and also at ground level of the tank G.I. railing including mlld steel gate of suitable size . The pipe will be supplied by the department free of cost.
All other required accessories such as bell mouth control valves of cast iron class PN-1 one for each out let and occur system shall be supplied and fixed by the firm.
All the fitting shall be embeded in the structure while the work is in progress. All connections shall be left out side the structure with sluice valves of appropriate class and specification in position ready for connection with incomming and outgoing pipes . direction of the scour shall be made towards natural drainage as per direction of Engineer-in-charge.
The safe bearing capacity of the soil shall be got tested by the contractor, however for design purpose. The safe bearing capacity shall not be more than 10 tonne per square meter. The design and drawing for the structure shall be supplied by the contractor/firm and shall be got approved by the competent authority before execution of the work.
The work shall be executed as per techinical specification attached in the NIT and direction of Engineer-in-charge . All the surrounding shall be levelled and make good and brought in proper shape as per direction of Engineer-in-charge.
All the pipe fitting , valves and other specials shall be ISI marked and confirm to relevant BIS codes and also shall be subject to the approval of Engineer-in-charge.
Excavation in foundation trenches etc. lift upto 1.50 mtrs. stacking the excavated soil not more than 3 mtrs. Clear from the edge of the excavation and then returning the stacked soil in 15 cm layers, when required into plinth sides of foundations etc. Consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth with in all leads and lifts . Pick work & jumper work 50% as per direction of Engineer-in-Charge with in all leads and lifts .
Boulder filling under the floor within all leads and lifts.
P/L C.C. 1:2:4(1 cement: 2sand: 4graded stone agg.40mm nominal size)and curing complete excluding the cost of form work and reinforcement work for rainforcement cement concerete work in foundation and plinth complete within all leads and lifts.
Providing and laying cement concrete 1:5:10 (1 cement:5 sand:10 graded stone aggregate 40mm nominal size)with 15 % plum excluding the cost of form work in retaining wall/brest walls the size Foundations and plinthwithin all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angles iron in frame 30x30x5mm so as to give a fair finish i/c centring,shuttering,propping etc.height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.height of propping and centring below supporting removal of the same for in situ work in reinforced concrete & plain concrete work:-.Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters,buttresses,plinth and string courses and the like within all leads and lifts.
SEWA SINGH
TILAK RAJ SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .