| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC YOL CAMP TEH DHARAMSHALA DISTT KANGRA HP | YOL | KANGRA | HIMACHAL PRADESH | 176052 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.8 L+₹71,296 (6.40%)Rejected-Finance | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹12.0 L+₹90,647 (8.14%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹12.4 L+₹1.3 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹12.7 L+₹1.6 L (14.1%)Rejected-Finance SHIVAJI NIWAS VILL CHIMBALHAR P O GEETA PEETH PALAMPUR HP 176061 | KANGRA | HIMACHAL PRADESH | 176061 | L5 | Rejected-Finance Other Than L1 |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
19 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KH Yol
GE KH Yol Cantt
Spl Repair to Bldg No 01 JCOs Md Accn of REC line UNDER AGE BR II AT GE KH YOL
2021_MES_444897_1
GE/Y-06/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE KH Yol
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KH Yol
₹26,000
Yes
16 Jul 2021
22 May 2021
21 Jun 2021
22 May 2021
19 Jun 2021
4 Jun 2021
24 May 2021 - 27 May 2021
60 days
Amount
SCHEDULE 'A' PART-T Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each and removing from site, all as specified.
Dismantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, all as specified.
Dismantling timber scantlings 40 sq. cm and over in section, in any position, framed work, complete all as specified.
Dismantling timber in fillets, rails posts rafters purlins etc under 40 sq. cm in section, in any position, framed work, complete all as specified.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling, all as specified.
Demolition of cement concrete (unreinforced) in ground floors and paving, not exceeding 15cm thickness (below or above ground level), un-reinforced, including removal of demolished materials not exc 100m and depositing where directed at a level n exc. 1.5 m above the starting point . complete all as specified.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to grade Fe 410 -W(Gde-E- 250 quality-A ) steel work, complete all as specified.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), fixed with self tapping screws as specified, all as specified and directed.
Aluminium anodised snap grid frame work of size 605 mmx 605 mm as in false ceiling,flat or sloping (pattern as per manufacturer's catalogue/instructions) cutting holes for electrical fittings fixed on and including aluminium tee of size 25mmx25mmx1.50mm as main runner, aluminium tee of size 25mmx25mmx1.25mm as cross runner and aluminium angle of size 25mmx25mmx1.25mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia glavanised (lingth as per site requirement)adjusted level fixed to roof by means of ceiling cleats made out of falvanised irom flat 40 mm x 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including necessary scaffolding all as specified and directed.
6mm thick non asbestos fiber cement building boards as in ceiling fixed or laid/ inserted to timber/GI / aluminium framework fixed with nails, including preparation of surface and applying three coats of white wash complete,all as specified.
Preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper complete, all as specified.
Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged and glazed skelton shutter(for glass and wire gauge) ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 No's for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Make : As per Appendix 'C'. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day.
MS work as in bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed etc. and similar articles con- forming to Fe.290.Gde-E-165, complete all as specified.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm fixed with tinned tacks or wire staples , all as specified.
Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares, not exc. 0.5sqm in each pane, complete all as specified.
Applying two coats of synthetic enamel paint over a coat of red oxide primer on steel or steel based surfaces of any description, over 10cm in width or girth including preparation of new surfaces , all as specified.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
PCC M-15, nominal mix, B-1 using 20mm graded mechanically crushed stone aggregate as, in lintels up to 1.5 metre clear span cuts, steps seismic and other similar bends, coping, bands plates for serving hold fasts etc. and the like including weathering slighting rounded or chamfered angles and throating complete all as specified. Note:- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Taking down cement plaster on brick or stone surfaces and tiles with bedding etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, mixed with WPC , all as specified. Note : Supply only Water proofing compound shall be measured and paid for seperately.
Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on other than fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Supply only integral water proofing compound, complete all as specified.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over 2mm thick wall care putty complete, all as specified.
Preparation of old plastered wall surfaces by complete removal of existing treatment and applying two coats of oil bound distemper over 2mm thick wall care putty complete, all as specified.
Preparing new sufaces of walls and applying two coats of weather coat paint (Apex-extirior emulsion paint) over and including a coat of 2 mm thick birla white wall cre putty comple all as specified and as directed.
Preparing old surfaces of walls by complete removal of existing treatment and applying two coats of weather coat paint (Apex-extirior emulsion paint) over and including a coat of 2 mm thick birla white wall care putty comple all as specified and as directed.
Mat finish (non skid), Premium class I grade, joint free, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand) complete, all as specified.
Mat finish (non skid), Premium class I grade, joint free, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in vertical surface and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 10mm thick rendering in cement mortar 1:4 (1 cement : 4 coarse sand) complete, all as specified.
M-15, nominal mix, B-0 using 12.5mm graded mechanically crushed stone aggregate as, in levelling course 25mm thick etc. and the like including weathering sli
Part-II Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including light fiitings any type,switches, sockets, holders, (batten or pendent type), ceiling rose, switch board , bell/buzzer,bell push, tube light fitting ,regulator etc. and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes and all as specified and directed.
Part-ITaking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including light fiitings any type,switches, sockets, holders, (batten or pendent type), ceiling rose, switch board , bell/buzzer,bell push, tube light fitting ,regulator etc. and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes and all as specified and directed.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including PVC condute medium grade, ISI marked of suitable size with all fittings/ accessories and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as phase, neutral and earth wire connected to common earth dolly and including concealed pressed steel/ cast iron of suitable sizes terminal boxes made from 1.60 mm thick sheet for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one bell point, independent, controlled by one way switch/ push button complete all as specified and directed.
All as per serial item No '34 above, but for one light point controlled by two way switches, all as specified and directed.
All as per serial item No '34' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '34' above, but for one 3 pin 5 Amps socket outlet on the independent board, all as specified and directed.
All as per Srl item No. '34' hereinbefore but for 3 pin 15 amps socket out let on independent with 2.5 Sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Replacement of Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into and including surface PVC casing & capping of suitable size with all fittings/ accessories, junction boxes 1 to 4 way 25mm dia and connected to common earth dolly, complete and as directed.Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
Switch piano flush type, single pole, one way, 5/6 Amps, all as specified.
Switch piano flush type, single pole, two way, 5/6 Amps, all as specified.
Switch , bell push, flush type, 5 Amps, all as specified.
Bell ding dong AC 230V, single pole, all as specified.
Switch socket outlet Two -in -One 3 pin 5 amps flush type, 230 volts AC multipurpose all as specified.
Switch socket combination 5 Pin, 5 Amp & 15 Amp flush type controlled by one switch, all as specified.
Ceiling rose, three phase, PVC/Polycarbonate, insulated body, all as specified.
LED tube light fitting integral type 1x20W, 230V, CCT 6500K connector block etc complete with all accessories internally repwired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. makes mentioned in Appendix 'C'.
LED tube light fitting integral type 1x10W CCT 6500 K, 230V, connector block etc complete with all accessories internally repwired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. makes mentioned in Appendix 'C'.
Ceiling fan regulator step type, electronic type varying 5 Speeds 230 Volts, 50Hz, suitable for 1200/ 1400 mm sweep ceiling fans, all as specified. (Makes as mentioned in Appendix 'C').
Taking down exhaust fans of any make/model/sweep for overhauling/servicing and cleaning of dust properly and then lubricating movable parts with suitable lubricanting oiling and greasing of both end bearings after opening of the fan including re-fixing and connecting up all as directed by Engineer-in-Charge.(Note: - Spare parts will be measured and paid separately).
Taking down the geyser , any capacity, from its mounting by removing all water and electric connection and disassembling the geyser, Descaling cleaning the inner tank thoroughly and there should not be any bad taste of contamination of water, Examining the water tightness of storage tank after cleaning and brazing., making it leak proof incluing teasting pressure , Reassembling all the geyser parts and testing including checking all electrical system (ensuring there is no current leakage) and re-fixing the Geyser and making electric connection, water inlet and outlet connection and testing and checking of all the functioning of water inlet outlet valves connected with geysers, complete all as specified.
Material and labour for rewinding of ceiling fan of any make/model including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaing agent, applying slot inslation and rewinding with super enameled insulated copper wire of same gauge / same number of turns as existing and connecting the coil suitable to operate on 230VC, single phase, AC supply including all winding, insulating material and impregnation of insulating varnish as specified of any make, type, model and applying air drying the winding throughly including transportation from site of rewinding 1200 mm sweep , complete all as specified .
Taking down Enargy Meters, checking and reoving from site by removing electronic circuits etc and re-fixing in same poistion, complete all as specified.
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 12 way, 240 volts with 200 Amp rated bus bar, all as specified.
M & L for vertical DB factory made TPN 4 Way ,MCCB as incomer and MCB SP as out going, double door DB IP 43 protection level, incl Blanking plate,lugs etc complete incl connection , fixing flushed to wall, necessary grouting, making good with CM 1:4 and painted to match exisitng wall color complete.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.
MCB SPN 6 to 32 Amp, 240 Volts, 10 KA all as specified.
MCB TPN 63 Amp, 415 Volts, 50 Hz, 10 KA all as specified.
35Watt energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source nd lens enbeddedPC cover having IP65 protection and impact resistance of IK07, suitable for pole dia 43mm(max) connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket complete all as specified and as directed Make: Havels description NDURACITYLITEPLATPLUSSL35WLED757SAYSBOPC or in makes mentioned in Appendix 'C'.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
Sand cushioning to under ground cables, 8 cm thick layer before laying and testing the cable and 15 cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Mild steel galvanised light grade 40mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Excavation in trenches not exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete M-15, reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
DHANI BUILDERS
KISHAN CONTRACTOR
Niraj Kumar and Co
MM Constructions
gani bhatti and co
M/S HIM BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .