Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED L1 | |
| 2 | L2₹42.5 L+₹67,452.20 (1.61%)Rejected-Finance | L2 | Rejected-Finance Being rejected L2 | |
| 3 | L3₹42.5 L+₹69,653.70 (1.67%)Rejected-Finance 18 MOTI BAGH BABYAL ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being rejected L3 | |
| 4 | L4₹43.8 L+₹2.0 L (4.77%)Rejected-Finance | L4 | Rejected-Finance Being rejected L4 | |
| 5 | L5₹45.1 L+₹3.3 L (7.86%)Rejected-Finance | L5 | Rejected-Finance Being rejected L5 |
Tender Value
₹48.4 L
EMD Value
₹96,886
Closing Date
16 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI N N LANGHE EE GE SOUTH AMBALA
GE SOUTH AMBALA CANTT
CA NO GE SOUTH AMB 54 2021 2022 SPL REPAIR TO BLDG NO 02 OF 2 CORPS OMC UNDER GE SOUTH AMBALA CANTT
2021_MES_488184_1
GE(SOUTH)/AMB-54/2021-2022
Open Tender
Civil Works
Item Rate
240 days
GE SOUTH AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AMBALA CANTT
₹96,886
Yes
20 Jan 2022
13 Nov 2021
18 Dec 2021
13 Nov 2021
16 Dec 2021
3 Dec 2021
13 Nov 2021 - 26 Nov 2021
60 days
Amount
SCHEDULE A PART I (B&R WORKS) Material and labour for brick work with sub class 'B' (old size) bricks, straight or curved on plan, exceeding 6 mtr mean radius built in CM 1:6 including demolition of old brick/stone masonry built in cement mortar of any description including all quoins, archs, pillars etc complete all as specified and directed.
Material and labour for brick work (except bricks) straight or curved on plan exceeding 6 metre mean radius built in CM 1:6 (old size brick) including demolition of old brick /stone masonry built in cement mortar of any description including all quoins, archs, pillars etc complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material complete all as specified and directed.
Taking down chowkats or frames with shutter, area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish complete all as specified and directed.
Description all as per Srl item No 4.00 above but area exceeding 1.5 Sqm and not exceeding 4.00 Sqm each, complete all as specified and directed.
Supply and fixing of mild steel framed work as in door chowkats, gate of angle or other section of grade Fe-290-Gde E-165 with gusset plate rails, braces etc welded/drilled to fixing of steel sheeting or other covering doors etc. to be prepared for sliding or hanging with and including either hooks and hinges or steel hanging door fittings (exclusive steel sheeting or other covering, running rails & guides) and hanging also fastening and fixing complete all as specified and directed.
Material and labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate) as hold fasts, copings, bed plates,kerbs or mud stops, lintels upto 1.50m span, plinth courses, seismic and other bands and the like, finished the surface fair and even, including necessary form work complete all as specified and directed.
Supply and fixing of factory made 35 mm thick, second class hard wood rail and style, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commrcial veneering on both faces ace, size of rails and stiles as per IS 1003 (part-I) kiln seasoned and chemical pressure treated complete all as specified and directed.
Supply and fixing of IInd class (hollock) factory made 35mm thick glazed skelton door shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in para 8.24(a) of SSR 2009 (Part I), complete all as specified and directed.
Supply and fixing of mild steel works in bands, straps, supports, stays, bolts, hooks, hold fasts etc, similar articles conforming to Fe-290.Gde-E-165, complete all as specified and directed.
Supply and fixing in repair factory made mild steel windows or ventilators, fixed type, with glazing bars, complete all as specified and directed.
Supply and fixing in repair steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. TD-219(c) sheet 1/3 to 3/3 and TD-220(c) sheet 1/3 to 3/3 as applicable including PCC(C-O ,1:3:6 using 12.5 graded agg) bed blocks for hold fasts, complete all as specified and directed. Note: (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery , grills 10mm square bars. (iii) Only Glazing, wire mesh & painting grill shall be measured & paid for separately)
Material and labour in repair aluminium alloy anodized (powder-coated) door frame and shutter with hollow aluminium anodized sections as specified including aluminium alloy anodized snap type beads, dish type door handles, glazed clip joint cleats, rubber gaskets, dead lock 4 levers, two numbers of aluminium alloy anodized tower bolts 200 mm long to each leaf consisiting of two numbers of shutters openable from both sides, three nos butt hinges, aluminium door closer each shutter etc. includinjg fixing frame to wall/RCC members with rawl plugs complete. Sections of doors shall be aluminium hollow sections as follows:- (a) Door frame single groove 101.6mm x 44.45mm x 2.15mm thick. (b) Shutter top 47.62mmx 44.45mmx 1.95mm thick. (c) Shutter bottom 114.30mmx 44.45mmx 2.15mm thick. (d) Shutter vertical 85mmx 44.45mmx 1.80mm thick. (e) Shutter middle 83.5mmx 44.45mmx 2.40mm thick. (f) Guauging clip weighing not less than 0.097kg/metre. Note:- The rates shall be inclusive of provision and fixing of rubber packing/gasket. Glass panes shall be measured and paid for seperately.
Supply and fixing (in repair) aluminium alloy anodized (powder-coated) window frame with double shutters open able type, with aluminium sections as specified for casement windows with double shutters including aluminium alloy anodized snap type beads, handles, aluminium anodized barrel tower bolts, glazing clips, joint cleats, rubber packing, gaskets etc for series-B “Jindal” section numbers for casement window.complete all as specified and directed comprising of followings :- (a) Frame of section 101.6mm x 44.45mm x 2.10 mm thick and section for shutter 47.62 mm x 44.45 mm x1.95 mm thick. (b) Mullion 53 mm x 52 mm x 2 mm thick not less than 1.065 kg/mertre. (c) Glazing clip weighing 0.259kg/mtr. (d) Window shall be provided with 02 Nos. of tower bolt for single leaf and 03 Nos. of tower bolts for double leaf. Tower bolts shall be aluminium alloy anodized weighing 0.302kg/mtr. Handles shall be aluminium anodized ‘D’ type handle of size 98 mm and thickness 2.37mm weighing 0.875kg/mtr and 01 no for each openable leaf shall be provided. Notes : 1. The rate shall be inclusive of provision of fixing of rubber packing / gasket. 2. Glass pane and wire gauge shall be measured and paid for separately.
Supply and fixing (in repair) aluminium alloy anodized (powder-coated) partition ( Area of each panel not exceeding 1.5 Sqm each) with frame of size not less than 100 mm x 44.4 mm x 2 mm including packing with rubber gasket, standard aluminium beading around both sides including 6mm thick plain coloured bakelite sheet or acrylic boards, prelaminated both side with one side decorative choice lamination for fixing in panels of aluminium partition as required complete all as specified and directed.
Supply and fixing of 6 mm thick plain coloured bakelite sheet pre-laminated both side decorative choice lamination or acrylic boards for fixing in panels of aluminium doors, complete all as specified and directed.
Supply and fixing of 5.5 mm thick tinted glass in square exc 0.5 sqm in each pane with heat reflecting properties, black glass file of 50 micron, fixed to aluminium frame with glazing clips, etc., complete all as specified and directed.
Supply and fixing of aluminum anodized barrel tower bolt extruded section 200mm long, complete all as specified and directed.
Supply and fixing of 250 mm long Mild steel sliding door bolt with hasp , staple (bolt type) fixing clips of sheet cast or extruded section & fixing bolts , sliding bolts of extruded section complete all as specified and directed.
Supply and fixing of butt hinges, medium weight cold rolled mild steel 100 mm size welded to angle iron frames or fixed with screws to wooden frames complete all as specified and directed.
Supply and fixing of aluminium anodized pressed handle, fabricated type of size 150mm, complete all as specified and directed.
Supply and fixing of mild steel helical door spring 150mm long including roller and roller plate, complete all as specified and directed.
Supply and fixing of extruded aluminium alloy handles, fabricated type, anodised 150 mm long complete all as specified and directed.
Supply and fixing of 2nd class hardwood small fittings such as brackets of any type, latch and hinge block, shaped door and window stops and the like including all labours articles not exceeding 200 cucm each complete all as specified and directed.
Supply and fixing of stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staple or fixing with beads to joinery when fixed in panels of joinery, complete all as specified and directed.
Supply and fixing of sheet glass 3mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane,(in repair ) incl hacking out the same complete all as specified and directed.
Supply and fixing in repair aluminium pre coated of choice colour designed type 25 mm tubular rod in curtain rod, 1.6mm fancy type including PVC golden colour brakets, latto and wall to wall socket etc., complete all as specified and directed.
Taking down timber roof trusses of clear span above 7.00 metre and upto 12.00 metre, complete all as specified and as directed.
Dismantling timber scantling 40 Sq. cm and over in section, in any position of unframed/ framed work complete all as specified and as directed.
Supply and fixing of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete including dismantling existing asbestos cement (corrugated, semi corrugated, etc.) sheets any type, gauge, thickness etc complete all as specified and directed.
Supply and fixing of Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete including dismantling existing asbestos cement (corrugated, semi corrugated, etc.) sheets any type, gauge, thickness etc complete all as specified and directed.
Supply and fixing of rolled mild steel as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with connecting plate or other connected plates etc. of Fe- 410W (Gde-250) quality 'B' complete all as specified and directed
Supply and fixing of mild steel screw bolts 11 to 15 mm neck dia, machine made with hexagonal or square head at one end & screwed the other or screwed both ends each screwed end to be fitted with washer & one hexagonal or square nut exceeding 5 cm and not exceeding 10 cm long complete all as specified and as directed.
Supply and fixing of rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W (Gde- E-250) quality- B complete all as specified and as directed
Material and labour for vitrified ceramic dark shade tiles of size 600 x 600 x 10 mm thick in floor etc laid over and including 15 mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry or with adhjesive as per the manufecturer's instructions and pointed in white or coloured cement to match tiles including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles of size 600 x 600 x 7 to 8 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles of size 600 x 300 x 7 to 8 mm thick as in vertical surfaces such as dado, skirting, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar (1:3) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for 50mm thick, PCC 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in plinth protection/PCC path, and paving, finished the surface even and smooth without using extra cement, joint filled with bitumen and sand mixture applied hot (area not exceeding 1.20 sqm ) , complete all as specified and as directed.
Taking down cement plaster of any description and in any position including raking out for keys, scrubbing down with water etc of any thikness & brick or stone wall etc. cement or cement lime plaster any description complete all as specified and directed.
Material and labour for rendering 15 mm thick on fair face of brick work , concrete surfaces in cement mortar 1:6 finished even and smooth w/o extra cement complete all as specified and directed.
Material and labour for 15mm thick rendering on surface of any description of brick work, concrete surfaces in cement mortar 1:4 mixed with WPC @ 2% by weight of cement or as per manufacturer’s instructions, finished even and fair, complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
Material and labour for rough cast plaster over 15mm thick rendering in CM 1:4 on brick or concrete surface in two layers (10 mm and 5 mm) of walls, pillars etc, of any description complete all as specified and directed.
Supply and fixing of integral water proofing compound complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of snowcem (cement base paint) over a coat of akali resistant primer on walls complete all as specified and directed.
Material and labour for preparation newly plastered surfaces of walls, etc and applying two coats of Oil bound distemper over a layer of 3mm thick Birla putty etc complete all as specified and as directed.
Material and labour for preparing new or previously untreated wood or wooden surfaces of any description not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour preparing surface of wood and wood based materials, new steel surface, iron surface treating small articals such as stop, covers, gully gratings, holdfasts,ends of posts, back of chowkats, etc, area tarred not exceeding 0.1 sqm each and treated with coal tar or coal tar black paint, complete all as specified and as directed.
Supply and fixing GI Metal Suspended Ceiling System at all heights of Perforated with Fleece 600x600x0.5mm TEULAR EDGE TILES in global white Powder Coated with 60-70 Micron front coating laid on 24mm wide Tee grid – strong section flanges colour white having stitching on the Main Runner, 600 mm and 600 mm Cross Tees with web height of 26mm. The tiles should have Humidity Resistance (RH) of 100%, with Light Reflection of 62%. The main runner spaced at 600 mm max (centre to centre) securely fixed to the structural soffit . Hangers (GI wire of 4 mm dia) to be fixed by approved roof plug, level adjusters and screws etc at 600x600 intervals as appropriate height,.The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 600mm long cross tees to be interlocked between main runners to form 600 x 600 mm with grid module(24X38X0.3mm).Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 600 mm cross tees. Perimeter trim to be wall angles of size 3000x22x22mm, secured to walls at 450mm max (centre to centre), complete includig taking down existing ceiling any type including wooden filletes if any complete all as specified and as directed.
Supply and fixing for heavy duty tiles (coloured), good grip series, size 300 mm x 300 mm x 10 mm thick, pattern as approved by Engineer-in-Charge, set, jointed and pointed in neat cement slurry, laid over and including 20 mm thick (average thickness) cement mortar (1:4) bed, complete all as specified and directed.
Supply and fixing PCC coloured , rubber moulded , interlocking designer paver blocks in any shape, confirming to IS-15658-2006 of 60mm thickness, M-35 grade in path, hard standing, etc. laid over and including 50 mm thick screed or bedding layer of sand, complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 using 40 mm graded mechanically crushed graded mechanically crushed stoneregates as in foundation, sub base and mass concrete complete all as specified & as directed.
Material and Labour for preparation of exposed brick wall surface by cleaning the surface wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day. NOTE : - Further treatment over the surface so achieved will be carried out only after approved of the same by GE.
SCHEDULE A PART I (E&M WORKS) Dismantling/taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush/sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators, bell push etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 56.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 56.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per item No 56.00 above but for one bell point controlled by one bell push complete all as specified and directed.
Description all as per srl item No 56.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fixing of modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular switches, one way, 16 amps, one module, 230 volt, AC supply, complete all as specified and directed.
Supply and fixing of modular socket outlet 6 amps, 5 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fixing of modular socket outlet 6/16 amps, 2 in 1, combined 2 module, complete all as specified and directed.
Supply and fixing of modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of door bell electric, ding dong /musical type, single phase 230 volts, ISI marked complete all as specified and directed.
Supply and fixing of ceiling rose surface bakelite 65 x 50mm, 3 terminal complete all as specified and directed.
Supply and fixing of fan regulator step type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing of lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Supply and fixing in replacement of unserviceable lamp any type with LED lamp 9 Watt with B 22 base cap type wider spread LED bulb with Opal Diffuser complete all as specified and as directed.
Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed.
Material and labour for hanging only ceiling fan any type/ seep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed.
Supply and fixing of channel for fixing of LED tube rod, aluminium housing body in CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. NOTE: - Tube rod shall be measured and paid for separately.
Supply and fixing of 18 W/ 20W Polycarbonate LED tube light, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
Supply and fixing of decorative surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing in repair bracket for security light made up of 25mm dia, 0.9 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing of LED security light luminaire 30 watt, pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Material and labour for concealed sub main wiring with four single core FRLSH PVC insulated unsheathed copper conductor cable 10 sqmm drawn in and including rigid non metallic PVC medium grade 32 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated, stranded copper conductor FRLSH of 10 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 5 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.50 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Supply and fixing in repair sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 20 Amps, 'B' curve, 240 volts complete all as specified and directed.
Supply, installation, testing of SPN distibution board 12 way, double door, IP 43, as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of SPN distibution board 4 way,double door, IP 43, as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 63 amps including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 250 amps rated bus bar IP43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole, 160 amps, 25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface including taking down existing MCCB DBs including MCBs complete all as specified and as directed.
Material and labour for galvanised tubing medium grade 50mm dia for fixing of ceiling fans complete awith all accessories insert and fixed on wall both end including PCC and cement work complete all as specified and directed.
Supply, laying, jointing and testing of PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 sqmm 3.5 core including provision of aluminium lugs for jointing etc complete all as specified and directed.
Supply and fixing of recess/ surface mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and as directed.
Supply and fixing in repair air termination, single pointed aluminium rod 12mm dia 300mm long complete all as specified and as directed.
Supplying and fixing for epoxy insulator size 40 x 40 x 25mm drilled and screwed including 2 Nos 8 mm dia 25 mm long hex head screw including dismantling of existing complete all as specified and as directed.
Supplying and fixing in repair test terminal block made of gun metal or phosphorous bronz size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw comeplete all as directed and specified.
Supplying and fixing in repair aluminium strip 25 x 3.15 mm with saddles and fixing screwes etc for roof conductors and down conductors above ground complete all as specified and as directed.
Supply and fixing for GI protection pipe 40 mm bore, light grade for cable protection including all fittings, laid in under road, fixed to wall, with fixing arrangement along the pole, under floor etc complete all as specified and as directed . (Excavation and earth work shall be measured and paid separately)
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and as directed.
Removing and spreading and levelling in layers not exceeding 25 cm thick of surplus excavated soil to a distance not exceeding 50 mtrs & depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and as directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and as directed.
Material and labour for sub class 'B' bricks old sizes over the for cable protection laid flat perpendicular to the cable for protection complete all as specified and as directed.
Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised iron strip 25 x 3 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009(Part-I) complete all as specified and as directed by Engineer-in-charge. Note :- (i) Earth strip and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. (ii) On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009(Part-I) complete all as specified and as directed by Engineer-in-charge. Note :- (i) Earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. (ii) On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
Note : - Amount of credit of Rs. 1,36,957.00 for retrieved materials is mentioned in Schedule of Credit Page Nos. 19(R) and 20(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
Ashwani Kumar
Gupta Enterprises
M/S JAISANT CONSTRUCTION CO.
SM ENGINEERS
Durga Enterprises
Sham Sunder Bansal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .