Loading…
Loading…
Tender Value
₹79.2 L
EMD Value
₹79,250
Closing Date
4 Jun 2026, 6:30 pmClosed
Vice President, (P), GUDC Ltd., Gandhinagar
Renovation of Civil & Interior works under deposit work of AHM (Re invitation) : Renovation of Civil & Interior works under deposit work of AHM : Renovation of Civil, Interior, Furnishing, Electrification works & Interior works of the office of the Secretary (Housing), Affordable Housing Mission (AHM) at Urban development and Urbana housing Department, Block No. 14/7, New Sachivalaya, Gandhinagar deposit work of Affordable Housing Mission (AHM).
308721
GUDC/PROJECTS/UDD/RENOVATION WORK
Open
Civil Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹4,248
GUDC Ltd., Gandhinagar
₹79,250
27 May 2026
27 May 2026
27 May 2026
4 Jun 2026
27 May 2026
ITEM NO ITEM DESCRIPTION AMOUNT (In Rs.)
22 Electrical Miscellaneous
* TOTAL ELECTRICAL WORK AMOUNT
23 ICT Distribution System For Data And Voice Infra
24 Cable Television Distribution System
* TOTAL ELV WORK AMOUNT
* TOTAL CIVIL + FURNITURE + E&M WORK AMOUNT
Item Description Quantity Unit Rate Amount (in Rs.)
DISMANTLING WORKS
Dismantling of existing masonry work of any type, while preserving the integrity of any existing
brickwork, regardless of thickness, plaster, or wall lining, using the necessary tools, plant, and
scaffolding. The work includes sorting the dismantled material, disposing of unserviceable material at
an approved location, and stacking the serviceable material with all required all lifts and all leads, as
directed by the Engineer-in-Charge.
The volume of the existing masonry work shall be measured for payment before dismantling begins.
The method for calculating the volume for payment shall be approved by the Engineer-in-Charge.
Dismantling or removal of tiled, paved floors, stone floors, including all required sub-layers and
stones from door jambs, windows, ventilation openings, wall tiles, dado, etc. This includes any
necessary earthwork and backing coat mortar. The work involves disposing of unserviceable material
at an approved location with all necessary lifts and all leads, and stacking serviceable material,
including loading and unloading for all required leads and lifts, as directed by the Engineer-in-Charge.
The area of the existing flooring/dado shall be measured for payment before the dismantling begins.
The method for calculating the area for payment shall be approved by the Engineer-in-Charge.
Dismantling of doors, windows, ventilators, nets, meshes, grills, rolling shutters, Louvers
(fixed/Openable) etc., whether wood or steel or glass, including frames, shutters, architraves,
holdfasts, hood covers, guide channels, and other attachments, as per site conditions. The work must
be carried out without damaging any adjacent structures or elements.
The serviceable material must be stacked with all necessary lifts and all leads, while unserviceable
material must be disposed of at an approved location outside the campus, including all required leads
and all lifts, as directed by the Engineer-in-Charge. Existing hardware fixed to doors, windows, and
ventilators shall be removed from dismantled elements and stacked as instructed by the Engineer-in-
Charge. The Identification of the servicable material shall be confirmed by the engineer incharge. The
dismentle each number of door/window /ventilators etc shall be measured for payment without
considering any wastage. No extra payment to be made regarding double shutter/ingle shutter/fixed
shutter/ transom etc
Chipping, Removing and scraping of old and/ or deteriorated plaster
Chipping, removing, and scraping of old and/or deteriorated plaster of any type and any thickness from
any surface, using methods that avoid damaging existing masonry, plain, or reinforced cement
concrete surfaces to be retained. This includes preventing vibrations to existing and neighbouring
elements. The work involves stacking serviceable material with all necessary lifts and any leads, and
disposing of unserviceable material at an approved location outside the campus, including all required
leads and all lifts, as directed by the Engineer-in-Charge.
(Note: This item does not apply to walls designated for demolition.) The area of the existing plaster
shall be measured for payment before the dismantling work begins.
Dismantling of any type of False ceiling
Dismantling of any type of false ceiling of any size, any shape, any thickness, anly floor, any
material, any level, including framing, accessories, etc. The work involves disposing of unserviceable
material at an approved location with all necessary lifts and all leads, and stacking serviceable material
within site area, including loading and unloading for all required leads and lifts, as directed by the
Engineer-in-Charge. The Identification of the servicable material shall be confirmed by the engineer
The area of the existing roofing shall be measured for payment before the dismantling begins. The
method for calculating the area for payment shall be approved by the Engineer-in-Charge.
Dismantling of any type of Partition/wall lining/panelling
Dismantling or removal of any type of Partition/wall lining/panelling of any material, any size, any shape,
any thickness, anly floor, any level, including framing, any type of superficial material, and other
component etc. The work involves disposing of unserviceable material at an approved location with all
6 necessary lifts and all leads, and stacking serviceable material within site area, including loading and 11.00 Sqm 83.48
unloading for all required leads and lifts, as directed by the Engineer-in-Charge. The Identification of the
servicable material shall be confirmed by the engineer incharge.
The single time area of the partition/wall lining/panelling shall be measured for payment before the
dismantling begins.
Removing of existing sanitary work
Removing existing sanitary fixtures and flushing cisterns, including all relevant accessories (WC, wash
basin, urinal, etc.). The work includes stacking useful materials near the site and disposing of
unserviceable materials at an approved location outside the campus, with all necessary leads and all
lifts, as directed by the Engineer-in-Charge.
Dismantling of existing metalworks at all levels, including dismantling, cutting, and dismembering all
structural elements by any means, as suggested by the Engineer-in-Charge. This includes earthwork,
base concrete, and reinstating the disturbed ground. The work involves stacking useful materials and
8 disposing of unserviceable materials at an approved location, including all necessary leads and all lifts, 100.00 Kg. 3.85
as directed by the Engineer-in-Charge.
The weight of the dismantled steel members shall be measured for payment. The method for
calculating the weight of the steel for payment shall be approved by the Engineer-in-Charge.
Total Carried Over to Summary
MASONRY WORK/PARTITION WORK
Item Description Quantity Unit Rate Amount (in Rs.)
1) Masonry work shall be carried out for all floors, all levels, all heights, and all places including
loading, unloading, stacking, transporting, hoisting, and erecting by any means (mechanical or
2) The Contractor shall grout all cavities, and holes/gaps in the masonry with suitable mortar as
suggested by the Engineer-in-charge and making good the required finish at no extra cost.
Providing and laying brick masonry in the superstructure using common burnt clay bricks conforming
to IS 1077-1992, having a compressive strength of not less than 35 kg/sq.cm in cement mortar 1:5 (1
cement: 5 coarse sand) in any shape, any thickness, including finishing, curing, scaffolding racking out
the joints/ flush jointing etc. complete for all levels, all floors, all heights, as per the issued drawings and
as directed by the Engineer-in-charge.
Providing and laying half brick masonry in the superstructure using common burnt clay building
bricks, having a compressive strength of not less than 35 Kg/cm2 in cement mortar 1:4 (1- Cement: 4 -
fine sand) in any shape, any thickness, including finishing, curing, scaffolding racking out the joints/
flush jointing, etc. complete for all levels, all floors, all heights as per the issued drawings and as
directed by the Engineer-in-charge.
Gypsum Dry wall system
Providing and fixing 2 hr fire rated 122mm thick double layered drywall partition system of approved
make for height up to 4.50 mt which includes (on both faces/ elevations) inner layer of tapered edge
minimum 12.5mm thick Fire Resistant Gypsum Board having density minimum 790 kg/m3 (conforming
to IS 2095 Part 1: 2011/ EN520::2004, TYPE-F/ ASTM C1396, TYPE X) and outer layer of tapered edge
12.5mm thick calcium sulphate dihydrate encased in high gsm paper liners with glass fibbers and other
additives for enhanced the fire, acoustics and impact performance, third party EPD Verified as per ISO
14025, having minimum density 900 kg/m3, with maximum allowable point load on single board 25 kg
to 30kg without any ply backing, complies with BS EN 520:2004 – Type A, F, D, R, I, Thermal
Conductivity: 0.24 w/mºK, Thermal resistance: 0.05 m2K/w.
Framing system -
GI framing system consists of Close stud/ C stud of size approximately 70x34x36x0.5mm confirming to
IS 513 having Y/S-minimum 230 Mpa, and Finish - AZ150 (IS 15961). The stud shall be placed at
600mm c/c in 72x32x32x0.5mm (approx.) floor channel and 72X32x32x0.5 mm ceiling channel. The
floor & Ceiling channel is anchored to the floor & ceiling using zinc coated Rawl plug of size Ø8x45mm
and having Pull out Load -7.5 kN/ anchor fasteners of required capacity as per the manufacturer's
specification at 600mm c/c. Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier
film to further improve corrosion resistance performance. A noggin channel of 70x40x0.5mm has to be
provided at the horizontal joints of the two boards and the top of the board in case the top is not going
up to the ceiling channel.
Gypsum boards shall be fixed with drywall screws of 25mm/ 35mm at minimum spacing of 300mm at
centre and 150mm at periphery. Boards shall be jointed and finished so as to have a flush look which
includes filling and finishing with Jointing compound, Joint Paper tape, angle beads at corners. The
junction of the partition with masonry/ RCC & all penetration through the partition has to be treated with
fire and acoustic sealant of approved make.
In case surface/member is not available abutting the door system for fixing, contractor shall design and
propose, a sub-system/ MS frame for fixing arrangement as per manufacturer's recommendation.
Contractor shall prepare shop drawing based on concept drawing including fixing arrangement,
services and prepare mock-up of required area. As per approved shop drawing and mock-up,
contractor shall start the work. Contractor shall furnish certification of entire system for STC 48 and
120 minutes Fire rating.
Dry wall system shall be fixed on any type of surface i.e. masonry, RCC, dry wall system, metal work
etc) with required capacity of anchorage as per manufacturer's specification. Stability of door and
partition system shall be responsibility of contractor.
Contractor shall provide fixing arrangement for all elements, which to be fixed in dry wall system.
All frame members shall be connected to each other by using metal screws. 50mm Rock wool slab of
density 24kg/m³ shall be placed in a metal framework. A Glass wool holding clip should be used to hold
the Glass wool slab in its position.
The rate shall be included for the cost of making openings for light fittings, switchboard, any other
services cut-outs made with a frame of perimeter member suitably fixed, etc complete for all levels and
all heights and as directed by the Engineer in Charge but excluding the cost of painting work. All
Opening cut outs & periphery shall be treated with Fire & acoustical sealant. The contractor shall be cut
the first layer of the gypsum board for the provision of skirting and, an additional board shall be
provided and the top layer to be cut properly as per manufacturer's specification. At the location of the
door frame in the drywall system, the wooden member shall be fixed to the required size and as per the
manufacturer's specification. Horizontal framing members shall be provided as per architectural
requirements and as suggested by the Engineer in charge.
Out to out area of drywall elevation on one side only shall be measured for payment after deducting for
openings for doors/windows and service cut-outs of size more than 0.36 sqm etc, complete for all
floors, all heights. Any additional members, support members, fasteners, fixing details, etc required in
dry wall system shall be designed and provided by contractor and approved by the Engineer-in-charge,
shall also be included in the rate of this item and nothing extra shall be payable for the same.
Total Carried Over to Summary
PLASTER AND WATERPROOFING WORK
Item Description Quantity Unit Rate Amount (in Rs.)
10 mm thick Cement mortar plaster
Providing and applying an average 10 mm thick single coat cement plaster and finishing with a trowel,
on the ceiling, side, and soffit of beam and stair, etc in cement mortar 1:3 (1 cement : 3 coarse sand),
12 in any shape, at all floors, all heights with necessary scaffolding, curing, application of bonding 194.00 Sqm 228.53
agent/making grooves, forming pattas, application of bonding agent/ hacking RCC surface properly,
etc. complete as directed by the Engineer-in-charge.
12 - 15 mm thick plaster - cement mortar
Providing and applying 12 to 15 mm thick plaster (smooth or wire-finished plaster) of cement mortar 1:3
(1 cement : 3 coarse sand) finished with a trowel on any type of surface. GI hexagonal chicken mesh of
size 20 mm x 20 mm of 22 gauge and minimum 200 mm wide at RCC & masonry junctions or between
different materials and 145 GSM of minimum 150mm wide fiberglass mesh with alkali resistant coating
shall be fixed at chasing areas of plumbing and electrical works, at corners and door and window joints
as per manufacturer's specifications with GI nails, hacking of concrete/application of bonding agent,
finishing, curing, making grooves, forming pattas, scaffolding in any shape for all floors, all levels, all
heights, etc. complete as directed by the Engineer-in-charge.
Waterproofing for Toilet, Wet area, balconies & Misc. areas
Providing and applying Two-part acrylic polymer modified cementitious elastomeric waterproof coating
of minimum 1.5mm thickness DFT having minimum 1 N/mm2 tensile strength, and shall cover
kg/sqm per mm of thickness. The coating shall have an elongation of a minimum of 80% when tested
as per ASTM D 412 resisting 5 bars hydrostatic pressure as per DIN 1048 and having crack bridging
ability of up to 2mm. Thorough surface preparation by mechanical means to level and plain the surface
of walls and floors of the toilet areas. All cracks and crevices shall be filled and made good to receive
waterproofing coating treatment The coating shall cover all the floor area of the wet area (toilet) and
shall also be applied over the vertical walls for a minimum 300mm height above the floor in two or more
coats to achieve required thickness. The periphery of the toilet floor shall be additionally reinforced with
an extra third coat of the coating with a fiber band (glass fiber mesh of minimum 80 gsm) sandwiched
between the first and the second coat, which shall also done around protrusions (pipes) meant for
plumbing purpose. The last coat (second/ third coat) when wet, shall be sprinkled with clean and
washed sand, to facilitate the floor screed or plaster.
Pipes being fixed for plumbing shall be fixed in holes that are mechanically core cut, more than the
diameter of the pipes. Pipes shall be fixed by grouting the annular space with non-shrink cementitious
grout of proprietary make. Before grouting, the pipes shall be wrapped with a two-way self-adhesive
tape at least 50mm wide and then grouted to fill in the grout, ensuring total watertight plumbing fittings.
The contractor shall submit a methodology statement with all details in illustrative sketch form and get
approval from the Engineer-in-charge. Application shall be carried out by the approved applicator of
manufacture and as per recommended by the manufacturer. The actual applied area on the floor & wall
shall be measured for payment. Cost includes all material (for surface preparation, coating, and hole
packing), labour, T&P, and wastage involved as mentioned in the item.
M25 Garede concrete screed for leveling
Supplying and laying M25 grade vibrated concrete screed in proper slope and gradient including saw
cutting (approx. 6mm W x 30mm D) at 3m x 4m panels or less size, making angle fillet of 50mm x
50mm at the corners using M25 grade concrete and filling the grooves with PU sealant (minimum
15 mm depth over PE backer rod). If Screed concrete shall be laid over on existing concrete surface, a 7.00 cum 5,096.71
bonding agent shall be applied before laying of concrete. Cost includes all material, labour, T&P, and
wastage involved as mentioned in the item. Reinforcement, if required, shall be paid under relevant
agreement items.
Total Carried Over to Summary
DOOR WINDOWS WORK
1. Only First class wood shall be used for any kind of woodwork. All wood (kiln seasoned and termite
treated) and wood base material shall be treated with anti-termite treatment as per relevant IS before
use and after installation. The guarantee shall be furnished for 10 years in the prescribed format as
directed by EIC.
2. Plywood (BWP grade IS – 710), laminate or other composite wood-based products shall be free of
urea formaldehyde.
3. All veneer, and wood shall be FSC (Forest Stewardship Council) & Green Guard Certified.
4. All loose samples of materials shall be approved by the Engineer in charge.
5. All manufactured products shall conform to Green building norms.
6. All adhesives and sealants shall be with low VOC and lead-free with acceptable VOC content as per
GRIHA requirements.
7. The contractor shall prepare a shop drawing based on the intent/ concept drawing and get approval
from the Engineer-in-Charge. The contractor shall prepare mock-up doors, windows, and other
elements with all required hardware and approved by the Engineer-in-Charge before execution of work.
Work shall be carried out as per the final approved shop drawing and approved mock-up. The
contractor shall be responsible against stability, safety, leakage, etc all complete. Testing work shall be
carried out by the Contractor as suggested by the Engineer in charge. (If required).
Item Description Quantity Unit Rate Amount (in Rs.)
8. All types of locks shall be with computerized 3 No. keys (SS 304/ brass) and master keys (if
mentioned in the nomenclature of the item). The grouping of master keys shall be as suggested by the
Engineer-in-Charge. Nothing extra shall be payable for the master key provision.
9. The contractor shall provide test certification for all fire-rated items.
10. Contractor shall make provision for access control system and other mechanical/ automation
devices, coordinate with other services work, and make goods, etc complete.
11. All Doors, windows, and other elements shall be fabricated and finished at the factory/ workshop,
and only fixing and final finishing shall be executed at the site unless otherwise approved by the
Engineer-in-charge.
12. Door, window, and other elements work shall be carried out for all floors, all levels, all heights, and
all places including loading, unloading, stacking, transporting, hoisting, and erecting by any means
(mechanical or manual).
Teak wood Frames for doors/windows etc.
Providing and fixing frames of doors, windows, transom, louvers and ventilators, jambs-sills, using best
quality kiln seasoned, termite treated first-class teak wood and fixed in position with hold fast lugs or
with dash fasteners with required dia & length of approved make, etc. for all levels, all floor, all height,
etc. as per drawing and as directed by an engineer in charge.
16 The rate shall be inclusive of all types of consumables, accessories, fasteners, and any type of corner 0.50 Cum 1,00,153.82
treatment (i.e. chamfering, pencil corner, bevelling, moulding, etc.). Polishing, hardware, and carving
work shall be paid in relevant tender items.
The contractor shall get the approval for the loose sample of first-class teak wood along with its source
location from the Engineer in charge before execution.
The actual volume of the installed wooden work shall be measured for payment without any wastage.
Aluminium work for door/window/louvers/ventilators etc. frame and shutter
Providing and fixing in position frames/ shutter for any type of aluminium work like aluminium door,
composite door-window, window (sliding, openable, side hung, top hung, fixed etc.), aluminium
partition, aluminium fixed louvers, fixed window with any type of aluminium sections of approved make
conforming to IS:733 and IS:1285 and finished with minimum 50 micron pure polyester powder
coating/anodized coating of approved shade, texture & colour of approved make for all floors/ all levels/
all heights/ all shapes/ all sizes including cutting, bending, crimping, fabricating in best workmanship
manner etc. as per the drawing, and as directed by Engineer-in-Charge.
Rate shall be inclusive of providing any type of aluminium sections, cutting, fabrication, hoisting and
1) Sheet metal screws and casted solid aluminium corner cleats fixed with a spring for rapid and secure
joint assembly for any type of shutter and frame;
2) Glazing clips for receiving infill panel;
3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM
4) Dash Anchor fasteners of approved make and capacity for fixing the frame assembly to the RCC or
masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for
stability of frame.
5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminium door shutter and 4mm
thick solid aluminium corner cleat of full thickness of section for connecting stile and horizontal rails;
6) providing and fixing packing at every 600mm c/c of PVC shims of required size;
7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker
rod of avg. 10 mm Dia of approved make or rough ground and colour and then sealing the remaining
gap with neutral grade weather silicon sealant of approved make and colour.
8) Termite treated seasoned teak wood as infill material to install hardware in door shutter and frame
as and when required but excluding. 1) necessary hardware; 2) Glazing or panelling material and
shutter. Contractor shall prepare shop drawing and get approved from the Engineer in charge before
procurement of material. All loose samples shall be approved. Work shall carried out as per the
approved shop drawings and approved sample.
Actual weight of installed Aluminium sections which are used shall be measured for the payment.
Contractor shall be responsible for stability, water tightness of door window work.
Providing and fixing door shutter made out of factory-made and pressed laminated/ veneer finish
40mm thick flush door shutter excluding the thickness of veneer/ laminate, made of ISI marked non-
decorative type flush door shutters conforming to IS:2202 (Part I), the core of block board construction
with the frame of 1st class hardwood, pine filler and well matched commercial 3 ply veneering with
vertical grains or cross bands and face veneers on both faces of shutters having laminates/ veneer of
approved make, shade, finish (which paid separately) as approved by Engineer-in-charge on both
faces of shutter fixed with phenol formaldehyde synthetic resin type adhesive conforming to IS
including providing and fixing 6mm thick peripheral external lipping made out of first class teak wood,
on all edges of door shutter with specified polishing on all exposed faces of lipping including fixing
shutters etc complete for all levels, all floors, all heights as per drawings and as directed by Engineer-in-
charge. The door shall be with a suitable acoustic peripheral door seal and drope down door seal of
approved make is included in this item.
The rate shall be inclusive of flush door shutter, teak wood lipping with PU polish, necessary
consumables, accessories, etc but excluding the cost of veneer/ laminates, all required hardware, and
polishing on veneer, etc complete for all heights as per drawing, design & direction by Engineer-in-
charge. The out-to-out area (one side) of the Flush door shutter shall be measured for payment.
Item Description Quantity Unit Rate Amount (in Rs.)
4 mm thick decorative veneer
Providing and fixing 4 mm thick decorative veneer (factory pressed with door shutter or plywood for
interior work) conforming to IS: 1328 (type-1) having the top layer of minimum 0.3 mm slice thickness
decorative veneer and base layer of approximate 3.5 mm thick BWP Gurjan Ply of approved make,
19 shade and pattern/ texture, for plain lining/ cladding/ ceiling work, on flush door shutter, pelmet or any 23.00 Sqm 1,253.36
interior work in any design, any pattern, any shape, etc with necessary screws, adhesive including
priming coat on the unexposed surface. The veneer shall be fixed on the ply with or without groove as
per drawing. The actual installed area of the veneer shall be measured for payment.
Providing and fixing glass in the door, window, ventilation, fixed glazing, partitions, etc. for all levels, all
floors, all heights with EPDM rubber/ neoprene gasket, etc. complete as per drawings and directions of
engineer-in-charge. (Cost of beading shall be paid in basic item). Glass shall be of any shade, any size,
any shape as per approved make, sample, and drawing and confirm to IS:2835 or IS:2553. The sample
shall be approved before the execution of the work. The installed area shall be measured for payment
without considering any wastage. In case of glass is required to fixed using patch fitting clamps &
screwes/anchor of approved make, It is included in this item.
b) With clear toughened glass panes of 8.0 mm thickness
a) With clear toughened glass panes of 12.0 mm thickness
Providing and fixing in position PVC frosted glass film of 100 to 130-micron (including adhesive)
thickness, of an approved make (of any pattern, shade, and type) on any type of glass for
22 internal/external use as per manufacturer's specification and as per issued drawing etc complete for all 10.00 Sqm 469.45
levels, all floors, and all heights. The film shall be pasted on the glass without any air bubbles. The
finished frosted film area on the glass shall be measured for payment without wastage. Warranty shall
be for a minimum of 05 years for material and installation of the film.
Cam action door closer
Providing and fixing cam action door closer of approved make with a minimum one-year guarantee and
approved finish for all levels, all floors, and all heights with controlled adjustable closing and latching
speed, with hold open feature and power-adjustable with track arm with screws to hinged door for
specified door width. All adjustment screws face fixed. The rate shall be inclusive of fixing using the
template as per the manufacturer’s specification & maintaining it in good working condition. The door
23 closer shall conform to EN 1154 standard. Selection of door closer shall be as per size and weight of 5.00 No. 10,214.94
the door, as per manufacturer's recommendation and as directed by the Engineer-in-charge. The
contractor shall arrange loose Samples for approval from the Engineer-in-Charge before mass
a) concealed door closer conforming to EN 2-4 for any type of the door, as per the manufacturer's
specifications, and/or compatible with the shutter weight.
SS 304 Butt hinges
Providing and fixing SS 304 butt hinges in matt stainless steel finish of the specified size of approved
make for all levels, all floors, and all heights of any type of door, with required SS 304 screws, etc.
24 complete. The rate shall be inclusive of fixing as per manufacturer’s specification & maintaining it in 24.00 No. 299.47
good working condition. The contractor shall arrange loose Samples for approval from the Engineer-in-
Charge before mass execution.
b) 100 x 75 x 3 mm - With ball bearing
Mortise Deadlock for single/ double door shutter
Providing and fixing a set of mortise deadlock (without latch) for single/ double shutter door, including
strike plate SS 304, and prepared for 60/70 mm length of standard euro profile pin cylinder as per DIN
18251-1, grade 2 of approved make with both side key/ one side key one side knob/ one side key one
side slot operation with pair of SS 304 escutcheons (keyhole plate) in matt/ satin finish as per approved
25 shape for wooden/ aluminium doors with necessary SS 304 screws, etc complete as per drawing and 3.00 Set 1,623.52
sample approved by Engineer-in-charge.
The rate shall be for all heights, all floors, and all places. The lock shall be with 3 number computerized
keys. The contractor shall arrange loose samples for approval from the Engineer-in-Charge before
mass execution.
Mortise sash lock with lever handle
Providing and fixing a set of mortise sash lock with SS 304 pair of Mortise lever handle with a cap of
any shape, and size in matt/ satin finish for single/ double shutter doors, including strike plate SS
and prepared for 60/70 mm length of standard euro profile pin cylinder as per DIN 18251-1, grade 2 of
approved make with both side key/ one side key one side knob/ one side key one side slot operation
with pair of SS 304 escutcheons (keyhole plate) in matt/ satin finish as per approved shape for wooden/
aluminium doors with necessary SS 304 screws, etc complete as per drawing and sample approved by
Engineer-in-charge.
The rate shall be for all heights, all floors, and all places. The lock shall be with 3 number computerized
keys. The contractor shall arrange loose Samples for approval from the Engineer-in-charge before
mass execution.
Item Description Quantity Unit Rate Amount (in Rs.)
SS 304 Grade Push-Pull handle (for any type of shuter i.e. glass/Flushdoor/aluminium shuter etc.
Providing and fixing SS 304 grade push-pull pair of handle in matt finish of the specified size, specified
shape i.e. H-shape/ D-shape/ offset shape (dent free at bending point)/ or reference image for any type
of the door, etc. of approved make for all levels, all floors, and all heights with required SS 304 screws,
27 accessories, and pin of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as 1.00 Pair 1,660.89
per manufacturer’s specification and maintaining it in good working condition. The contractor shall
arrange loose Samples for approval from the engineer-in charge before mass execution. Overall length
of handle shall be considered.
a) 300 mm long as per reference image x 1mm (thickness of pipe)
28 c) 600 mm long as per reference image x 1mm (thickness of pipe) 3.00 Pair 2,703.37
SS 304 Tower bolt
Providing and fixing SS 304 grade tower bolts of the specified size, and specified shape (with or without
flap) in matt/ satin finish for the door, window, transom, etc. of approved make for all levels, all floors,
and all heights of any type of door, with required SS 304 screws and accessories of the required size
for fixing, etc. complete. The rate shall be inclusive of fixing as per manufacturer’s specification and
maintaining it in good working condition. The contractor shall arrange loose Samples for approval from
the Engineer-in-Charge before mass execution.
C) 450 mm x 10 mm rod size
SS 304 door stopper
Providing and fixing SS 304 door stopper with or without magnet, lever type, shutter mounted/ wall
mounted/ floor mounted in matt/ satin finish as per approved design, approved make and approved
shape of for the door, window, transom, etc. for all levels, all floors, and all heights of any type of door,
30 with required SS 304 screws and accessories of the required size for fixing, etc. complete. The rate 5.00 No. 333.00
shall be inclusive of fixing as per manufacturer’s specification and maintaining it in good working
condition. The contractor shall arrange loose Samples for approval from the Engineer-in-Charge before
mass execution.
Shaft door lock
Providing and fixing shaft door lock with key (Alen Key lock) with Escutcheons (keyhole plate), strike
plate, locking sleeve, etc in stainless steel matt finish of approved make in any approved shape/size for
any type of doors with necessary SS 304 screws, etc complete as per drawing and sample approved by
Engineer-in-charge. The rate shall be for all heights, all floors, and all places. The contractor shall
arrange loose Samples for approval from the Engineer-in-Charge before mass execution.
Providing and fixing SS 304 grade handle in matt finish of specified size, specified shape for door,
window, etc. of an approved make for all levels, all floors, and all heights for any type of door, with
required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The rate
shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good working
condition. The Contractor shall arrange loose samples for approval from the Engineer-in-Charge before
mass execution.
a) Flush handle/ concealed handle - 150 mm long Flush Handle - Concealed handle recessed in the
depth of the shutter with pull arrangement for shutter, as per approved design and shape
Aluminum powder coated Multi point lock with (without locking arrangement)
Providing and fixing Aluminum powder coated multi point lock with mortise handle/ inbuilt flush handle
(without locking arrangement) in approved finish, color, and shade of the required size and capacity of
approved make for internal/external shutter as per approved sample with necessary SS 304 screws,
handle, connector, extension, nib, nib holder, counter plate, fork, pawl, polyamide strip, connection pin,
rod terminal, locking point, striker and corner transmission etc. complete for all levels, all floors, and all
heights as directed by Engineer-in-charge.
The rate shall be inclusive of fixing as per manufacturer’s specification & maintaining it in good
working condition. The contractor shall arrange loose Samples for approval from the Engineer-in-
Charge before mass execution.
b) For aluminum hinged door and window shutter (top hung or side hung)
Providing and fixing adjustable/ fixed Teflon roller bearing set with reinforced nylon casing of
approved make (twin or single wheel according to weight and size) for sliding window/door as per
34 drawing etc. complete for all floor, all height, all level as per approved sample and as directed by 50.00 No. 211.04
engineer in charge.
Total Carried Over to Summary
FLOORING AND DADO/CLADDING WORKS
Item Description Quantity Unit Rate Amount (in Rs.)
1) All natural stones shall be free from cracks, lines, stains, and white spots of efflorescence, and even
in shade for all kinds of stonework.
2) All natural stones shall be selected and sorted for uniform colour, figure, and thickness and
approved by Engineer-in-charge prior to procurement.
3) All natural stones shall be from the same lot and/ or source (stone quarry) for the same kind of work
to avoid shade variation and as approved by the Engineer-in-charge.
4) All types of loose and laid samples of flooring shall be approved by the Engineer-in-charge.
5) The contractor shall apply approved Stone Impregnation primer/ sealer coat on both sides and all
edges (after cutting and finishing the stone as per size) of stones in a minimum of two coats as per the
manufacturer's specification and as directed by the Engineer-in-charge. No extra shall be paid for the
6) Contractor shall co-ordinate and execute for all services in flooring and wall lining/ cladding work i.e.
making openings/ cut-outs for any services (i.e. elevator operating panel in lift wall cladding, raceway in
flooring, junction box, etc), and making good as per the satisfaction of Engineer-in-charge.
7) All stones shall be cut to size with the help of with water jet cutting/laser cutting/ CNC machine
according to the design and shape for best workmanship etc according to the design as per the
approved shop drawing.
8) All adhesives and sealants shall be compatible with material as per IS 15477 and as per the
manufacturer's specification and with low VOC and lead-free with acceptable VOC content as per
Green building requirements.
9) Finished floor surfaces shall be protected with a 12mm thick POP sheet over an LDPE sheet up till
handling over the project. The tread of the stair shall be protected with a metal/ plywood angle to avoid
damage to the edges of the tread. POP shall not directly (or with the use of paper) apply on flooring.
10) Screed below flooring/ base mortar thickness shall be as per drawing. In case of any type of stone/
tile shall be fixed with adhesive and the total thickness of base mortar/ screed shall be paid in relevant
11) All stone shall be factory cut and factory finished. Polish or any type of texture finish on any stone
shall be as per the satisfaction of the Engineer in charge.
12) Flooring and wall cladding/ lining work shall be carried out for all floors, all levels, all heights, and
15) Rate shall be inclusive of all types of wastage of all material.
Vitrified tiles - For flooring - fixing with cement mortar
Providing and laying Vitrified tiles (superior quality tiles) with water absorption less than 0.08% and
conforming to IS: 15622, of specified sizes, specified thickness, approved make, any finish (anti skid/
satin/ polished etc), any shade, any color, and any shape for flooring in required design and patterns as
per the drawings, laid over average bedding 40 mm thick cement mortar 1:4 (1 cement: 4 coarse
sand), jointed with a groove or without groove with grey/white cement slurry mixed with a pigment to
match the shade of the tiles, including finishing, cleaning, protection, scaffolding, wastage, etc. all
complete for all levels, all floor, all height, as specified and as directed by the Engineer-in-Charge.
Rate shall be inclusive of vitrified tile (as per approved sample), fixed with cement mortar bedding,
cement slurry, matching pigment, all labour etc complete but excluding filling with epoxy grout (if
required) and additional cement mortar bedding/ concrete screed bedding as per drawing which shall
be payable under relevant Tender item. The contractor shall arrange loose Samples for approval from
the Engineer-in-Charge before mass execution.
The actual laid area of the vitrified tiles shall be measured for payment without considering any
a) With full body, homogeneous, vitrified tile of size 600 x 600 mm x minimum 9mm thick
Vitrified tiles - For dado/ riser/ skirting fixing with adhesive
Providing and laying Vitrified tiles of specified sizes, with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, shade and finish (matt/ satin/ polished etc) in wall tile/
dado, riser of steps, and pillars laid in any pattern over any type of levelled surface, in any pattern with
suitable cement based high polymer modified quick set tile adhesive (water based) conforming to IS:
15477of approved make and jointed with groove or without groove with cement slurry mixed with
pigment to match the shade of the tiles, including providing 6 to 10mm wide groove between wall tiles
and plaster edge treatment, rubbing, curing, finishing, cleaning, protection, scaffolding and wastage
etc. all complete as specified and as directed by Engineer-in-Charge. Length of tiles for dado shall be
as per design to match the joint and pattern. Shade of dado must be match with flooring stone.
Rate shall be inclusive of vitrified tile (as per approved sample), adhesive for fixing, cement slurry,
matching pigment, all labour etc complete but excluding filling with epoxy grout which shall be payable
under relevant item.
a) With full body, homogeneous, vitrified tile of size 600 x 600 mm x minimum 9mm thick
Grouting the joints of flooring/ wall tiles/ stone
Extra for Providing and Grouting the joints of flooring/ wall tiles/ stone as specified having joints of up to
37 5 mm width in total thickness, using epoxy grout of approved make and shade including PVC spacer, 62.00 Sqm 190.84
filling/ grouting, protecting tile, abro-tap and finishing complete as per direction of Engineer-in-charge.
a) Tiles/ stone of any size
Item Description Quantity Unit Rate Amount (in Rs.)
Additional Floor bedding with Cement mortar :
Providing and laying cement mortar 1:4 (1 cement : 4 coarse sand) for additional thickness below
flooring item required for gradient and as per drawing and as directed by engineer in charge including
spreading as per gradient, levelling, finishing, curing etc complete as directed by Engineer in charge.
Actual laid volume for floor bedding shall be measured for payment without considering any wastage.
Engineered Wooden flooring and skirting
Providing and fixing 3 layered 12 to 15mm thick Engineer wooden flooring and skirting of approved
type, any shade/ wood species and of approved make, in required pattern and as per manufacture’s
specification confirming to British Standards BS EN 13489. Top layer of plank shall be made of
minimum 3.0 mm natural wood/ veneer of any shade, finish, pattern and texture. Surface of top layer
shall be pre finished with several layer of UV hardened Acrylic lacquer, which shall be free from urea
formaldehyde and solvents. Flooring plank shall be interlocked using lock and fold system in a glue
less floating manner. Engineered wood planks shall be a composition of layers of Pine wood with
direction of each layer oriented at right angle to the adjacent layer of natural strain in lacquer and non
bevelled/ bevelled in length and width as specified. Wooden flooring shall be FSC (Forest Stewardship
Council) & Green guard certified.
Rate shall be inclusive of min 2mm thick underlay sheet as sound barrier and/ or vapor barrier
(combination of PE film and extruded foam) and all the accessories like edge strip, joining strip, quarter
strip, moulding strip, end strip, corner strip, skirting, threshold etc. required as per design. Uniform gaps
shall be left on all sides to allow expansion and contraction of material. The gaps are covered with the
help of accessories etc. finished in all respects as per the manufacturers specifications.
Rate shall be inclusive of making any cut-out for services, floor matching cover over cut outs etc.
complete. The contractor shall get approval of sample and pattern from Engineer in charge before
execution. Area of flooring and skirting including accessories (without considering any wastage) shall
be measured for payment.
18 mm thick granite vanity/washbasin counters and facias:
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and pre-polished, machine
cut granite of any size, any shape, any shade, for vanity/ wash basin counters and fascias, and similar
locations, of required size, approved shade, colour and texture, laid over 20 mm thick cement mortar
1:2 (1 cement : 2 coarse sand) base, joints treated with white cement, mixed with a matching pigment,
40 epoxy touch ups, including making all holes & cutouts for SS sink, wash basin, piller tap/ bib cocks, 2.00 Sqm 1,889.10
rubbing, curing, rounding edges, champhering and polishing to edges, to give a high gloss finish etc.,
complete, at all levels, as directed by the Engineer-in-Charge. The plan area of the counter and the
elevation area of the facia shall be measured for payment.
If required, metal framing/supports shall be paid in relevant Tender items..
Total Carried Over to Summary
FALSE CEILING WORK
Notes for False ceiling work
1. Points to be taken care of by contractor before selecting a manufacturer from approved
• Board/ tiles/ panel, grid system, suspension system and all accessories shall be from a single vendor
and from the same make unless otherwise approved by Engineer-in-charge.
2. Points to be taken care of by contractor before installation
• Contractor shall corelate all services drawings from different installers and prepare a clash free shop
drawing as per architectural drawings for RCP, with all services integration vis a vis HVAC, FFTG,
PLUMBING, ELE, ELV & any other services planned and part of design.
• The methodology statement for execution of all services coordinated with ceiling execution shall be
submitted by Contractor for approval of Engineer-in-charge before commencing execution work at site.
• Quality check and sequence of execution along with relevant documentation to be ensured by the site
project team for inspection and quality checks.
• Installation to be carried out by an approved and certified installer of manufacturer. Contractor to
submit manufacturer approved certificate of installer to Engineer-in-charge before commencing work.
3. Points to be taken care of during installation
• False ceiling work to be strictly supervised for alignment, line & level and overall quality of installation
and contractor to strictly follow approved methodology statement.
• False ceiling suspension work shall be strictly from mother slab or secondary support installed for
false ceiling and not from any other services suspension members.
• Trap door to be fixed in line & level with false ceiling, with separate suspension system from mother
slab, not with false ceiling member. Groves around trap doors should be uniform on all sides.
• All service equipment & light fixtures, curtains etc to be fixed with a separate suspension system from
mother slab, not on false ceiling tile or false ceiling member.
• In gypsum ceiling, contractor shall provide perimeter channel at periphery of all services cutout for
strengthening the system. All cutout in board shall be finished with tape, angle skimming coat etc as
per manufacturer's specification.
• If required, additional supports to be provided for fixing the false ceiling (in case of special shape,
more height etc).
Item Description Quantity Unit Rate Amount (in Rs.)
• In case the height of suspension system is more than recommended by manufacturer, separate MS
work to be provided from mother slab and false ceiling to be suspended from MS work. Design and
shop drawing for MS fabrication work and connections with structure members shall be submitted by
contractor for approval by Engineer-in-charge. MS frame work to be designed to accommodate other
services if required to be submitted on the same frame. Such MS frame work shall be paid under
relevant tender item.
• Sequence of execution of different services to be aligned with RCP to avoid any rework.
• Movement joints/ groove to be provided in board or grid ceiling system in large span area.
4. Points to be taken care of post execution
• Warranty for false ceiling system to be provided by installer & manufacturer to ensure that work is
completed as per specification (material and workmanship) and methodology statement.
• Completion certificate to be provided by installer & to be signed and verified by manufacturer with
respect to tender specifications and approved shop drawing.
• All test reports are to be submitted by the contractor for performance.
5. General Notes
• Contractor to quote the rate considering all points mentioned in the specifications.
Gypsum False ceiling:
Providing and fixing false ceiling at all height including providing and fixing of frame work made of
special sections, power pressed from M.S. sheets and galvanized with zinc coating of 150 gms/ sqm
(both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick
with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with
dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre
to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of
mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular
to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm
and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of raw plugs at 450 mm
centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling
section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of tapered and square edges of the board with
recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering
up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per
manufacturer's specification
In False ceiling, drop-down patta (vertical) more than height/ width of 300 mm shall be measured and
paid. The rate shall also include the cost of making openings for light fittings, grills, diffusers, and cut-
outs made with a frame of perimeter channels suitably fixed, all complete as per drawings,
specifications, and direction of the Engineer in Charge but excluding the cost of putty and painting.
Installation shall be carried out by an approved installer and the material of the suspension system shall
be as per manufacturer specifications.
The contractor shall prepare a shop drawing with coordination of all services and opening/ excess.
41 Sample, shop drawing, and mock-up shall be approved by the Engineer in charge. The actual installed 101.00 Sqm 1,133.17
area in the plan and area for vertical drop down more than height/ width of 300 mm shall be measured
for payment without considering any wastage and without deductions of area for lights, diffusers,
columns, etc. Nothing extra shall be paid for making provisions for lights, diffusers, AC grills, fire alarm
systems, sprinkler systems, and other such fittings/ services in false ceiling. Work shall be carried out
as per the approved sample, Mock-up, and shop drawing including all material and labour.
a) 12.5 mm thick Fire resistant Glass Reinforced Gypsum (GRG) Boards (Confirming to BS476)
complying to IS: 2095 :
b) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 %
perforated area with perforation size and pattern as approved by the Engineer-in- charge and as per
manufacturer's specification.
Mold resistance paperless Gypsum Ceiling
Providing and fixing a suspended ceiling system using a minimum 12.5 mm thick paperless, modified
glass fibre reinforced gypsum core board with enhanced moisture and mould resistance as per EN
15283 Part-1. The board shall have a thermal conductivity of 0.3 W/mºK, thermal resistance of
m²K/W, and conform to ASTM D3273 for mould resistance and EN520 Type H1 for water resistance.
The board shall have square or tapered edges on all four sides.
The suspension and grid system will be constructed from GI (IS-513), with a yield strength of 260 MPa,
finished with a 150 GSM galvanized coating as per IS-277. The sections will feature a serrated,
knurled, chequered, or ribbed pattern. A 0.5 mm perimeter channel will be fixed along the perimeter of
43 existing walls using 6x40 mm impact anchors of an approved make at 600 mm centres. A 0.5 mm 6.00 Sqm 1,139.84
ceiling angle will be suspended by attaching it to a soffit cleat, made of CR1 grade (IS-513) material,
with a zinc coating of 7 to 8 microns and a pull-out load capacity of 6.8 kN. This setup will create a
1200 mm x 1200 mm grid.
The intermediate channel, 0.9 mm thick, will be secured to the ceiling angle using an M6 x 12 mm hex
nut and bolt arrangement (material as per EN 10083, finish: zinc plating) or with 2 no. Ø4.2x13 metal-to-
metal screws made of carbon steel as per EN-ISO 7049/50 with a minimum 4-micron zinc coating. The
ceiling section will then be fixed to the intermediate channel using connecting clips made from high
carbon spring steel wire (BS970 Gr. En 42, 46-48 HRC, finish: zinc plating 4-6 microns) and positioned
perpendicularly to the intermediate channel at 600 mm centre-to-centre spacing.
Item Description Quantity Unit Rate Amount (in Rs.)
Single-layer gypsum boards shall be secured to the ceiling section using 25 mm drywall screws made
of carbon steel (EN-ISO 7049/50). The joints shall be finished with a jointing compound, recommended
filler, jointing tapes, and finisher conforming to ASTM C475, to achieve a flush appearance. The
finishing process shall include two coats of primer suitable for the board, as per the manufacturer’s
specifications. The cost shall include making openings for light fittings, grills, diffusers, and other cut-
outs, framed with perimeter channels and fixed as per the drawings, specifications, and directions of
the Engineer in Charge, but excluding the cost of putty and painting.
For false ceilings with drop-down pattas (vertical elements) exceeding a height or width of 300 mm,
measurements and payment will be based on the actual installed area. The rate shall include the cost
of creating openings for light fittings, grills, diffusers, and other fixtures, framed with perimeter channels
and installed according to the drawings and specifications and as directed by the Engineer in Charge.
The cost excludes putty and painting.
The Contractor shall prepare shop drawings in coordination with all services, including provisions for
openings and access. Samples, shop drawings, and mock-ups must be approved by the Engineer in
Charge. Payment will be made based on the actual installed area, including vertical drop-downs
exceeding 300 mm, without accounting for any wastage or deductions for lights, diffusers, columns,
etc. No additional payment shall be made for making provisions for providing lights, diffusers, AC grills,
fire alarm systems, sprinkler systems, and other fittings/services.
Access panel/ trap door
Providing and fixing ready-made powder coated Access panel/ trap door of approved make of
600x600mm size for any height as per drawing including aluminium outer and inner frame, door
shutter, push latch, safety cable and hook, removable hinge, intermediate and perimeter channel etc
for all floor, all height etc complete as directed by engineer in charge. Tile/ board of access panel shall
be matched with false ceiling board. The contractor shall submit the technical data sheet of the product
regarding loading capacity to the engineer in charge. A loose and installed sample/ mock-up of the
44 access panel shall be approved by the engineer in charge. 2.00 No 1,872.84
The contractor shall prepare a shop drawing based on the concept drawing including fixing
arrangements, and services, and prepare a mock-up of the required area. As per the approved shop
drawing and mock-up, the contractor shall start the work.
The access panel system shall be fixed on any type of surface i.e. RCC, metal work, etc) with the
required capacity of anchorage as per the manufacturer's specification.
The contractor shall provide a fixing arrangement with an adjoining false ceiling and the bottom of the
slab. The stability of the access panel system shall be the responsibility of the contractor.
Total Carried Over to Summary
WALL PANELLING WORK/CURTAIN WORK
1) Contractor shall prepare shop drawing based on concept drawing/ design for all false ceiling,
panelling and partition work co-ordinate with services and get approved by Engineer in charge before
execution of work.
2) All veneer and wood shall be FSC (Forest Stewardship Council) & Green Guard Certified.
3) All Manufactured products shall be with at least 5% recycled content.
4) Sample of all loose material and mock-up shall be approved by Engineer in charge.
5) Any wood/ wood base material / plywood / MDF Board shall be treated with antitermite treatment as
per relevant IS before use. Rates are inclusive of anti-termite treatment of all such members.
6) Contractor shall co-ordinate for all services in wall panelling/ ceiling work i.e. making openings for
light fittings, switch board, electrical points, grills, diffusers, cut-outs for any services, provision of
addition framing member for strengthen, making good as per satisfaction of Engineer in charge.
7) All elements shall be factory fabricated and finished, only final finishing to be made on site with all
8) Contractor shall coordinate all services work (cutouts and provisions) in all type of wall panelling,
false ceiling, partition, pelmet and other interior work. All cutout and services provisions shall be
finished at factory/ work shop.
Providing and fixing 12 mm thick plywood BWP grade (IS – 710) of approved make having, a density
minimum 600 Kg/m3, emission levels as per E-1 formaldehyde, for wall panelling/lining/ cladding/ False
ceiling work, pelmet or any interior work in any design, any pattern, any shape with necessary screws,
for all height all level, etc complete as directed by Engineer-in-Charge. The rate shall be inclusive of
45 6mm thick peripheral beading all around to ply (width of beading as per ply + finish surface) as per 10.00 Sqm 609.38
Veneer/ laminate or any other finish shall be paid in the relevant tender item. Out to out Area of
installed plywood shall be measured for payment without considering any wastage.
1 mm thick laminate
Providing & Fixing 1 mm thick high pressure (factory pressed) laminate sheet of any type, any finish,
any shade, any texture of approved make and shade with high-density protective surface layer and
reverse side of adhesive bonding quality conforming to IS: 2046 Type S, including cost of adhesive of
approved quality. Laminate shall be applied on the door shutter, wall paneling, ceiling, or any interior
work, etc. The sample shall be approved by the Engineer-in-charge. The actual installed area of the
laminate shall be measured for payment.
Item Description Quantity Unit Rate Amount (in Rs.)
Veneer Panelling
Providing and fixing Veneer Panelling/patta as per concept design/ drawing and as per the following
specifications:
1) Aluminium framing system for panelling shall be installed on any surface with the required size and
type of anchor fasteners of an approved make, with aluminium sections of approved make, conforming
to IS: 733 and IS: 1285; of required size and thickness at a maximum distance of 600mm c/c in both
directions. All aluminium member shall be anodized finished of an approved make and shade
(anodized transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of
grade AC 15). The aluminium quality shall be as per grade 6063 T6 and BS
2) 12mm thick, BWP grade (IS – 710) plywood shall be fixed with aluminium framing with the required
fixing arrangement and shall create the required shape, size and pattern in true line and plumb.
3) 4mm thick Gurjan ply veneer having a slice thickness of 0.5mm of an approved make and shade
shall be fixed on plywood in the required pattern as per concept design/ drawings. Veneer sheet shall
be of approximate size 3048 x 1220mm (10' x 4’).
4) First class teak wood skirting and beading of required size shall be fixed on the ply surface with
required adhesive, nails, screws etc., as per the concept design/ drawings
5) All exposed veneer and wooden surfaces shall be finished with an exterior grade water base
Polyurethane (PU) clear matt finish/ glossy finish/ semi gloss finish polish of an approved make and
shade including surface preparation, base coat of wooden primer, stainer coat of approved shade (if
required), minimum 3 coats of PU polish followed by sandpapering with fine sandpaper up to minimum
400 micro grit-sized sandpapers and up to satisfaction of Engineer-in-Charge.
6) Provision of fixing hanging shall be included and to be shown in shop drawing for fixing like
logo/frames/storage units/artworks etc.
7) The wall panelling shall have provision of solid wood framework above the shelf to hang the framed
8) MEP services to be coordinated as per site conditions and drawings.
The Contractor shall prepare and submit a shop drawing that coordinates all services based on the
concept design and approved drawings. This submission must include detailed design calculations for
approval by the Engineer-in-Charge. The rate shall be inclusive of the aluminium framing, plywood,
veneer, wooden skirting, PU polish, designer cutting in the required shape, size pattern, edge beading,
arrangement for lighting and other services, hardware, adhesives, accessories, anchors, fasteners,
scaffolding, wastage, etc complete, for all levels, all height, all floors as directed by Engineer in charge.
A mock-up shall be carried out as per the approved shop drawings. Work shall be carried out as per
the approved sample, mock-up, and shop drawing including all material and labour. The actual
installed area in the elevation shall be measured for payment without considering any wastage and
without deductions of areas for any type of service elements. No additional payments shall be made for
provisions for fittings/services.
Fabric & acoustic panel wall panelling
Providing and fixing minimum 25mm thick Acoustic and Sound Absorption Panel System, of the
required size, manufactured from 100% polyester fibers/ polypropylene/ polyethylene terephthalate
panel Fibers Needle punched and thermally bonded in a non – woven matrix semi rigid specifically
tooled and pressed for maximum sound absorption, with minimum 80% NRC (0.80 NRC) and meets
the British Fire Rating Standards BS 476 standard Class 1Y, Class P, Fire Propagation index = 9.2,
with 0.006% moisture absorption (will not rot or smell) in grey or/ and white colour fibers, which is UV
stabilized, non-allergic and non toxic as per concept design/drawing and as per the following
1) A Paneling shall be installed on the required Metal/Aluminium framing system. The aluminum
quality shall be as per grade 6063 T6 and 6062 T6, 6061 T6 and comply to BS 1474. Framing shall be
fixed on any surface i.e masonry, stone, RCC, metal, der wall etc.
2) Required thickness plywood, BWP grade (IS – 710) plywood shall be fixed with metal framing with
the required fixing arrangement in the required shape, size, and pattern.
3) Acoustic Panel System shall be fixed on the required thickness of plywood and metal framing work
(any type), which shall be fixed into the wall and shall create a true line and level with screws, fixed
horizontally or vertically as per design/drawing.
4) Acoustic and Sound Absorption Panel System shall be covered with a tightly stretched open cell
fabric over the entire panel including all sides. Designer Fabric with acoustic and fire retardant
properties of approved make and shade and selection as per approved sample shall be covered on the
acoustic panel for wall paneling work in the required pattern as per drawing with all necessary stitching,
adhesives, screws etc.
5) The acoustic panel with fabric shall be fixed with teak wood beading/lipping if required as per design
6) All exposed surfaces of wooden shall be External grade water based PU polished as per
The contractor shall prepare a shop drawing coordination of services based on the concept design and
drawing and submit it along with the design calculation for approval from the engineer in charge. The
rate shall be inclusive of acoustic fabric panel, metal framing, plywood, teak wood beading, designer
cutting in the required shape, size pattern, edge beading, PU polish, Teak wood lipping/bedading as
per design intent, arrangement for lighting and other services, hardware, accessories, anchor, fastener,
adhesives, scaffolding, wastage, etc complete for all levels all height, all floors as directed by Engineer
in charge. A mock-up shall be carried out as per the approved shop drawing. Work shall be carried out
as per the approved sample, Mock-up, and shop drawing including all material and labour. The actual
installed area in the elevation shall be measured for payment without considering any wastage and
without deductions of area for lights, diffusers, columns, etc. Nothing extra shall be paid for making
provisions for providing fittings/services.
Item Description Quantity Unit Rate Amount (in Rs.)
Solid Wooden batten + Ply+Veneer paneling
Providing and fixing solid wooden batten acoustic wooden paneling as per concept design/drawing and
as per following provisioned:
1) A Paneling shall be installed on the required Metal framing system.
2) 19mm thick veneer finish plywood, BWP grade (IS – 710) plywood shall be fixed with metal framing
with the required fixing arrangement in the required shape, size, and pattern.
3) 4mm thick Gurjan ply veneer having a slice thickness of 0.3mm of approved make and shade shall
be fixed on plywood (factory pressed) in the required pattern as per concept design/drawing with teak
wood beading at the end of the panel of the required size.
49 4) Perforation shall be made in a pressed sheet of ply and veneer 16.00 Sqm 7,103.33
with a cutting machine in a good finish wherever required to achieve acoustic properties.
5) Finished 25mm x 40mm size Superior class teak wood strips/ battens @ 50mm c/c shall be fixed on
veneer-finished plywood panel as per drawing and shall create a true line and level with required
screws, nuts, fastener, adhesive, etc complete. The length of batten shall be as per the approved
drawing for joint.
6) Glass wool shall be laid in paneling for acoustic purpose.
7) All exposed surface of wooden and veneer shall be polished as per specification. Elevation area of
panelling shall be measured for payment without considering any wastage.
The contractor shall prepare a shop drawing coordination of services based on the concept design and
drawing for approval from the engineer in charge. The rate shall be inclusive of plywood, veneer, teak
wood batten, Glasswool, perforation making, designer cutting in the required shape, size pattern, edge
beading, arrangement for lighting and other services, hardware, accessories, adhesives, anchor,
fastener, scaffolding, wastage, etc complete for all levels all height, all floors as directed by Engineer in
charge. A mock-up shall be carried out as per the approved shop drawing. Work shall be carried out as
per the approved sample, Mock-up, and shop drawing including all material and labour. The actual
installed area in the elevation shall be measured for payment without considering any wastage and
without deductions of area for fittings/services.
Mirror with aluminum frame:
Providing and fixing 6mm thick superior quality wall hung mirror with modular aluminium frame. Mirror
shall be extra clear, decorative type, best quality, bevelled edge at the periphery and of an approved
make, in any shape and size.
The aluminium frame shall be up to 100mm wide, extruded type, with anodized finish of an approved
make in any shape and shade.
The backing of the mirror shall be 8mm thick cement bonded particle board/fibre cement board/ IS
Marine Ply and fixed with silicon sealant/double sided tape to the mirror.
The mirror assembly shall be with a floating hanging system with required hanger, Z bar or french cleat
etc., complete, in proper plumb and level etc. for all floors, all levels, all heights as directed by the
Engineer-in-Charge. The rate shall include the mirror,cement fiberboard, anodised aluminium framing,
including adhesive, double sided tape, screws, fasteners and all required accessories. Out to out area
of the mirror with the aluminium frame shall be considered for payment without any wastage.
MDF Molding Patti
Providing and fixing approximate 25mm thick moulding patti made of MDF board of approved make,
fixed on masonry wall/ plywood/ RCC surface/ ceiling/ gypsum surface etc. Moulding patti shall be in
linear or curvature shape as per design/ drawing. Moulding shall be in tapered, circular or any other
shape in desired design and size with carving work (to create a design) as per drawing. Moulding shall
be fixed on levelled surface with adhesive, nails, wooden joints, SS 304 screws with out appearing any
impression in vision. Location of joint in moulding patti shall be as per design and as suggested by
engineer in charge. Exposed surface offinished with water base acrylic/ PU coating of approved make,
shade and finish.
Contractor shall prepare shop drawing base on concept design and get it approved before starting the
work. Rate shall be inclusive of material, labour, finishing, wastage, fixing accessories, scaffolding etc
complete for all height and as directed by Engineer in charge. Sample and mock-up shall be approved.
Elevation of area of finished moulding shall be measured for payment.
Item Description Quantity Unit Rate Amount (in Rs.)
Letter Mount Signage, Logo & Map signage
Providing and fixing Cut Letter Sign, Logo & Map of specified/required size as per design intent in any
languages, any font style as per concept design/ drawings, cut / routed from approx 2 mm thk MS plate
of variable size as per artwork/content schedule on any type of surface(metal/masonry/stone/RCC or
any other material in any shape) with anchor fastener of required capacity and make or by any other
means as per desig inent, at any level any height. fabricated using water jet, CNC cutting machine,
machine bending or by any means as required.
The top surface of the cut / routed letter/signage element to have a chamfer edge/rounded corner as
per the design intent. signage to be fixed and secured with 304 grade SS M5 grub screws on 304 grade
SS required capacity stand-off pins anchored to mounting surface and with partially threaded required
length 304 grade SS studs using silicone caulk, on the mounting surface, as per design intent. Letter,
stand-off pins, studs, SS bolts, and fasteners to be finished with PU paint in the required colors as
specified in the final artwork/content schedule as per approved make. Mounting of signage to be done
using appropriate reusable templates,made in suitable material as per requirement, with locations of
studs, for drilling holes on the mounting surface, as per artwork/design intent/content schedule. The
loose sample of stone and laid mockup shall be approved by the Engineer-in-charge before mass
52 execution. The Architect and the Engineer-in-charge reserves the right to reject part or all of the work if 2.00 Sqm 40,829.25
it is substandard not as per the approved sample or per mock-up or does not confirm to the approved
sample/mock-up. Content of sign shall be letters (in any language), number, graphics/ maps, signs,
arrows, etc. in any colour as per design, drawing and approved by Architect and Engineer. The rate
shall also include cost of scaffolding, drilling, fabrication, finishing, adhesive material, back and sides
plain cap sheet, fixing charges, accessories, anchor/fastner etc at all height and all lead. Contractor
shall prepare shop drawing based on concept design, including it's fixing arrangement with back
structure/ back surface integrated with wall finishing work, all services work (i.e. lighting work). Sample
and mock-up shall be approved before mass production and execution. Stability of fixing for signage
and logo shall be responsibility of contractor. The contractor shall submit the drawings with as per
design intent before execution. Outer most dimension of the letters shall be measured for payment and
Elevation area of MS logo and Map shall be measured for payment.
Providing and fixing SS 304 grade brush finish 1.0 mm thick Internal signage of any shape any size
and in any language like Gujarati, Hindi and English with letter, numbers, graphic, arrow, symbol etc
made by etching with duco paint/ laser print or vinyle sticker with lamination of approved shade. All
signage plates shall be made in CNC water jet cutting, with all smoothen edges and pencil round
corner. Signage matter shall be as per drawing. The plate shall be fixed on brick masonry or RCC wall/
door with the necessary fixing like stud, fastner, self adhesive or adhesive etc complete for all floor all
height as directed by Architect and Engineer in charge. The rate shall be inclusive of all material,
labour, drilling, fasteners/ adhesive, scaffolding etc. at all heights. Only elevation area shall be
measured and paid. The contractor shall submit the shop drawings based on concept design and
prepare the sample and get it approval before execution.
Total Carried Over to Summary
PAINTING/POLISHING WORKS
1) All adhesives, sealants & paint shall be water based, with low VOC with acceptable VOC content as
per Green Building Norms requirements and lead free.
2) Paint shall be applied after thoroughly brushing the surfaces, free from mortar dropping and other
foreign matter, preparing the surface even and sand papered smooth etc, after applying every coat of
putty and primer complete.
3) Contractor shall furnish warranty paper, wherever applicable.
4) If necessary more coats shall be applied till the surface presents a uniform appearance without any
5) Paint shall be applied with any means (i.e. brush, roller, spray etc)
6) Contractor shall prepare sample of minimum three shades as suggested by engineer in charge for
7) The rate shall be applicable for all floor, all level, all height by any means of scaffolding.
White cement-based putty
Providing and applying white cement-based putty of average thickness 1 mm, of approved make and
54 manufacturer, over any surface to prepare the surface even and smooth complete for all floor all height 571.00 Sqm 81.31
Providing and applying priming coats with the primer of approved make and manufacture, having low
55 VOC (Volatile Organic Compound) content, Modified acrylic, water-based alkali-resistant primer with 571.00 Sqm 45.30
low VOC over any surface to complete for all floors all heights all levels.
Acrylic emulsion paint - interior grade
Providing and applying premium acrylic emulsion paint (superior quality) of interior grade Two coats of
interior grade premium acrylic emulsion paint of approved make and shade with highly washable, Anti
56 fungal, anti bacterial, scratch resistant and scrub resistance property, having VOC (Volatile Organic 571.00 Sqm 88.98
Compound) content less than 50 grams/ litre of approved make, on wall/ ceiling/ false ceiling/ partition
etc including applying additional coats wherever required to achieve desired even shade and colour.
Item Description Quantity Unit Rate Amount (in Rs.)
PU polish - for external/internal wooden & veneered surfaces:
Providing and applying interior/exterior grade water-based polyurethane (PU) polish of any shade and
finish (matt, glossy, or semi-glossy) of an approved make on new or existing external and internal
wooden and veneered surfaces at all levels and heights. The polish work shall be carried out as
1) Surface Preparation: Sandpapering with various grades, up to 220 macro grit, to the satisfaction of
the Engineer-in-Charge.
2) Sealer Application: Applying two coats of sealer using a spray gun or other suitable means, allowing
sufficient drying time as per the manufacturer’s specifications.
3) Wet Rubbing: Once the sealer coat has dried, wet rubbing with fine emery cloth using ample water to
remove the excess sealer layer and smooth the surface. After wet rubbing, apply special grade PU
fillers to fill any small or large holes/grooves. Allow the filler coat to dry as per the manufacturer’s
specifications.
4) First Coat of PU Polish: Apply the first coat of PU polish with a spray gun or suitable means. Once
dry, sandpaper the surface using fine sandpaper up to 400 micro-grit. This process shall be repeated
three times, ensuring a smooth finish.
5) Stainer Coat Application: Apply a stainer coat of the approved shade, if required. Sandpaper the
wood surface using fine sandpaper up to 600 micro-grit as per step wise requirement for polishing, to
achieve a smooth finish, to the satisfaction of the Engineer-in-Charge.
The polish application shall be conducted according to the manufacturer’s specifications and as
directed by the Engineer-in-Charge. A sample must be approved by the Architect before the full
execution of the work. The single time applied area of polish shall be measured for payment without
considering any wastage.
Total Carried Over to Summary
1. All adhesives, sealants & paint shall be with low VOC with acceptable VOC content as per GRIHA
requirements and lead free.
2. The Contractor shall prepare shop drawings based on the concept design/ drawings for any type of
fabrication work and get them approved. The Contractor shall prepare mock-ups/prototypes (as
suggested) as per the approved shop drawings for approval. Work shall be carried out as per the
approved shop drawings, approved mock-ups/prototypes and as suggested by the Engineer-in-Charge.
3. The rate shall be for all floors, all levels and for all heights.
4. The rate shall include the cost of all types of fasteners (ETA approved) to be used for fixing.
5. Structural stability shall be responsibility of the Contractor for all kinds of metal work.
6. All elements shall be factory fabricated and finished, only final finishing to be carried out on site with
all precautions.
7. The Contractor shall coordinate all services related work (cut-outs and provisions) in the metal work.
All cut-out and services provisions shall be finished at the factory/work shop.
8. The Contractor shall provide PVC/nylon seprators, where two different metals connect, to avoid
galvanic reactions.
Structural steel work - Fabrication works - with PU paint:
Providing, fabricating, assembling, hoisting, erecting and fixing in position, structural steel work, at all
heights, all levels, all shapes & sizes with all leads & lifts, using any type of MS sections like rolled steel
sections, hollow sections, plates, chequered plates, bars, sheets, rods, threaded bolts etc. all
conforming to the latest relevant IS codes for the metal elements, i.e. railings, signage poles, gates,
bus shelters, screen walls, commercial poles, gantry structure, grills, bracings, foundation plates &
bolts, platforms, brackets, fencing poles, framing for advertisement boxes on lighting poles, electrical
elements etc. including straightening, cutting, bending, bolting and welding the members, all as per the
58 structural drawings and as per detailed specifications (for materials & workmanship) including profile 100.00 Kg 111.20
cutting, smooth grinding, machining of edges/faces, all necessary welding (electric arc welding) for the
required weld lengths and sizes, machine drilling of holes for joining/anchoring, all necessary
arrangements for templates to keep the foundation bolts in position, dry sanding, degreasing (wet
cleaning) & preparation of rust-free surfaces manually or mechanically, metal putty to make the
surfaces even and smooth, necessary scaffolding/staging, anchor fasteners for fixing, etc., complete,
for all floors, all heights and all level as directed by the Engineer-in-Charge.
Additionally, the fabricated steel work will be finished with PU paint to ensure durability and aesthetic
The Contractor shall prepare coordinated fabrication/shop drawings and obtain approval before
commencing any fabrication work along with design calculations to ensure the stability of the elements.
All fabrication work must be executed with precise architectural workmanship and in accordance with
Sections V and VI of IS 800 and IS
The rate shall include the application of two or more coats of PU paint (DFT min 40 micron per coat) on
all surfaces of MS members of approved make and shade. This shall be applied over two coats of anti-
corrosive epoxy base primer (DFT minimum 50 microns per coat), as per the manufacturer’s
specifications, anchor fasteners, etc., all complete. The weight (by theoretical means) of MS
members/structure/element shall be measured for payment without considering wastage, fixing
accessories such as nuts, bolts, fasteners etc.
Total Carried Over to Summary
WATER SUPPLY, PLUMBING & SANITARY FITTINGS
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
59 National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings 5.00 RMT 170.36
and clamps including making good the wall, ceiling and floor etc. complete.[A] 15 mm.
Item Description Quantity Unit Rate Amount (in Rs.)
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
60 National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings 4.00 RMT 208.80
and clamps including making good the wall, ceiling and floor etc. complete.[B] 20 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
61 National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings 4.00 RMT 253.82
and clamps including making good the wall, ceiling and floor etc. complete.[C] 25 mm.
62 Providing and fixing brass screw down stop tap. [C] 25 mm. 2.00 Each 220.82
63 Providing and fixing Gun metal check or non-return full way wheel valve. [C] 25 mm. 2.00 Each 420.63
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the
64 following nominal diameter of self cleansing design with C.I scread down or hinged grating including 2.00 Each 599.64
the cost of cutting and making good the floor.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for waste water
including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of
65 clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. 2.00 RMT 148.12
including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS
13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with
66 rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm 4.00 RMT 876.90
length x 145 mm heigh at every 2000 mm center to center or shall be concealed in floors as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed
with adhesive solvent cement including cost of all materials.
Providing and fixing of 110mm Diameter SWR quality (type B) UPVC fitting of Swept Tee with door,
confirming to IS 14735 laid in proper line and level complete as per drawing and direction and
satisfaction of Engineer in Charge.
Make: Astral / Ashirvad / Prince
Supplying, fixing, testing and commissioning of white Vitreous China Wall Mounted water closet
(European type EWC-P) as per IS: 2556 (Part 2) , with soft close seat and lid as per IS: 2548, of size
and shape as approved by engineer in charge, including rag bolts, fixing in position, grouting and
finishing, making good the walls and floors wherever required. The work to be completed in all respect
to the satisfaction of Engineer-In-Charge.
a) EWC-P:- Make: Kohler / Toto / American Standard
Providing and fixing UPVC SWR WC Connector 130 x 110 mm dia. Socket type of approved make,
fixed to outlet gaskets with UPVC Lubricant or Solvent Cement, all complete as per directions of the
Engineer-in-charge.
Make: Astral / Ashirvad / Prince
Supplying, fixing, testing & commissioning of Single Piece Concealed Cistern Body with installation kit
& 'P type' drain pipe connection & Full Frame set for wall hung WC, with dual flush 3/6 ltr with wall flush
plate of approved make including concealed valve and push fit flexible hose complete including cutting
and making good the walls where required complete as directed by Engineer-in-charge.
The scope includes the following:
a) Flush Tank with Full Frame; & Dual Flush Plate:- Make: Kohler / Toto / American Standard
Supplying, Fixing & Installing of white vitreous China Over Counter Wash Basin as per IS: 2556 (Part 4)
of size and shape as approved by engineer in charge,, including drilling hole for the faucet & waste
71 coupling, filling the gaps with appropriate silicon cement, complete as per the direction, approval and 1.00 Each 13,352.55
complete satisfaction of the Engineer-in-charge.
Over counter Basin - Make: Kohler / Toto / American Standard
Providing, fixing, testing and commissioning of chrome plated Brass Angle valve / Angular Stop Cock
with wall flange, including connection with the water supply pipeline, complete as approved and
directed by the Engineer-in-charge.
Angle Stop Cock - Make: Kohler / Toto / American Standard
Providing and fixing 32mm Grid Drain (with Full thread) (Waste Coupling) without overflow, in Polished
Chrome of approved make and conforming to Manufacturers Standards. Work to be completed to the
satisfaction of the Engineer-In-Charge.
Make: Kohler / Toto / American Standard
Providing and fixing 32mm CP 300mm bottle trap with wall flange, of approved make and as directed
74 by Engineer-in-charge. (For Wash Basins). 1.00 Each 956.47
- Make - Kohler / Toto / American Standard
Providing and fixing Chrome plated ABS Hand Shower (Health Faucet), having a discharge of
LPM, including 8 mm dia, 1 Meter long Flexible tube & wall hook including connection with the angular
stop cock, complete of approved make and quality and as approved by Engineer - In - Charge.
Make: Kohler / Toto / American Standard
Supplying and fixing of single toilet paper roll holder with flap made of stainless steel material, at levels
76 as directed by the Engineer in charge. 1.00 Each 1,821.43
Make: Kohler / Toto / American Standard
Supplying, fixing, testing and commissioning of S.S. single robe hook of approved make, fixed to PVC
cleats with C.P. brass screws, etc. all necessary accessories complete as per direction of Engineer-in-
Make: Kohler / Toto / American Standard
Item Description Quantity Unit Rate Amount (in Rs.)
Providing and fixing of 610mm long SS Towel bar in polished chrome with wall flange of approved
78 make as per drawing and direction and satisfaction of Engineer in Charge. 1.00 Each 1,821.43
Make: Kohler / Toto / American Standard
Providing & fixing heavy quality SS 316 grade polished chrome body touchless soap dispenser of size
180 x 320 x 150mm battery operated having 2 sets of AA or AAA batteries as required, driling holes in
walls / tiles, attaching the mounting brackets with appropriate fasteners, filling the dispenser with
litres of liquid / gel soap as per manufacturers' standards, testing and commissioning as approved and
directed by the Engineer-in-charge.
Make - Kohler / Toto / American Standard
Providing & fixing heavy quality hidden square floor drain cover in polished chrome of size 100 x 100 x
82mm, connected to Nahni trap including setting in floor with white cement sand mortar 1 : 2 to match
80 with floor finish with proper care for preventing side leakages, as approved and directed by the 2.00 Each 3,275.63
Engineer-in-charge.
Make: Kohler / Toto / American Standard
Total Carried Over to Summary
FURNITURE WORKS
1) All wooden furniture shall be manufactured from Superior class teak wood, BWP IS-710 ply, veneer,
laminate, customized/ readymade fabric as per selection, exterior grade PU polish as per specifications
and approved by the & Architect.
2) "Furniture Intent Document" to be referred for furniture reference image, furniture code and sizes for
all the furniture items as given in the schedule. The contractor shall prepare and submit shop drawings
and prototypes of various furniture items as required by Engineer-in-charge for his approval. Shop
drawings should be submitted before preparing prototypes. Mass production shall be carried out only
as per approved samples/prototypes. The contractor has to submit the “As Built” shop drawing for
completed furniture items.
3) Contractor shall be responsible for stability of all furniture items.
4) Provision for connectivity of Power outlets, Multimedia, AV, internet, laptop power, extra power,
microphone, etc. or similar to be given in the furniture with cable organizer, grommet, vertebrae vertical
cable, cable tray etc. (whatever required) or similar to be coordinated with electrical drawings, which
shall be included in the quoted rate of furniture item. However, items like multimedia, AV, internet,
laptop power, extra power, microphones etc., shall be payable under relevant tender items.
5) "Procurement of items with aesthetic value and visibility shall be on prior approval of Engineer in
charge for specific area of application.
6) Front elevation area of storage unit/ mechanically driven compactor system/ mobile storage shall be
measured for payment in Sqm unless otherwise specified. (Front elevation facing the storage shelves
of compactors/ storages unit shall be considered for measurement.)
7) Cost of each desk shall be inclusive of fliptop panel, grommet wherever specified in particular item
description/ Data sheet. Accessories like desk organiser, monitor arm, bag hook, etc.are excluded.
8) Fabric and stone shall be selected and approved by Architect & Engineer-in-charge.
9) Lipping shall be of minimum 2mm thick solid teak wood unless otherwise specified.
10) Only First class teak wood shall be used for any kind of woodwork. All wood (best quality, kiln
seasoned, termite treated and sorted for uniform veins wood) and wood base material shall be treated
with anti-termite treatment as per relevant IS before use and after installation. The guarantee shall be
furnished for 10 years in the prescribed format as directed by EIC.
11) Veneer shall be 4mm thick of natural teak wood selected and sorted for uniform veins, as approved
by engineer-in-charge. The natural veneers slice shall be minimum of 0.5mm thick and backed ply shall
be of BWP grade and density shall be minimum 650 kg/ m3.
12) Laminates shall be 1mm thickness of any colour, finish, texture as approved by engineer-in-charge.
13) All the faces of ply are to be finished with either laminate or veneer, if not specified in the ref.
14) The dimensions of furniture unit and its members mentioned in BOQ item & furniture intent
document are indicative and nothing extra shall be paid or recovered for variation in actual dimension
15) The reference image given are indicative. In case of any discrepancy between BOQ item and
furniture intent document, the BOQ item shall prevail. Incase of any discrepancy within furniture intent
document, decision of engineer-in-charge shall be final and binding.
16) Incase of any discrepancy in specifications between furniture intent document and specified model
of item, the furniture intent document shall prevail.
17) In case, model specified in BOQ item/ furniture intent document of any furniture item is changed/not
available with the manufacturer, the alternate equivalent or superior model of same company can be
considered with the prior approval of Engineer-in-charge and nothing extra shall be payable for the
18) If item/reference image has brass letters/emblem then such brass item shall be paid for in relevant
19) Shutter stiffeners to be provided in full height (3300 mm) storages to maintain the strength of the
shutters and to avoid bending of shutters as per requirement and in consultation with the engineer-in-
Item Description Quantity Unit Rate Amount (in Rs.)
20) The aluminium and MS tube/pipe shall be of minimum 2mm wall thickness unless otherwise
21) The Desk & Workstation tables top thicknesses may be varied as per functional comfort and as
directed by engineer-in-charge.
22) For storages the carcass & internal support shall be made of minimum 19mm thick IS 710 Grade
ply and shelves and backing of carcass shall be minimum 12 mm thick IS 710 Grade ply. However, for
members of large span/height, higher thickness of ply shall be provided for structural stability &
functional comfort for which nothing extra shall be payable over the quoted price.
23) For veneer finish wall panelling, veneer sheet shall be of approximate size 3048 x 1220mm (10' x
24) Exterior Grade water based open grains PU polish to be provided on all wooden and veneer
CUSTOM-MADE CATEGORY:
Executive Desk with two (2) return units - C-DK-02
Approximate Dimension (L x W x H) - 3000 X 1050 X 750, two (2) Return unit - 1625 X 600 X
81 Supply and Installation of the Executive Desk with two (2) return units having a main table as per the 1.00 No 2,40,998.63
reference image. The Executive Desk with two (2) return unit items shall be as per the furniture
Low height Storage Unit - C-SU-03 (Main Office)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture intent
Supply and installation of the low-height storage unit as per the reference image. The low-height
storage unit item shall be as per the furniture datasheet. The front elevation area of the storage unit
shall be measured for payment.
Low height Storage Unit - C-SU-08 (PA office)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture intent
Supply and installation of the low-height storage unit as per the reference image. The low-height
storage unit item shall be as per the furniture datasheet. The front elevation area of the storage unit
shall be measured for payment.
Full Height Storage Unit - C-SU-09 (PA office)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture intent
Supply and installation of the full height storage unit as per the reference image. The full height storage
unit item shall be as per the furniture datasheet. The front elevation area of the storage unit shall be
measured for payment.
Storage Unit - C-SU-10 (Ante room)
Approximate Dimension (L x W x H) - As per Furniture intent document x 700 x As per Furniture intent
85 document 2.00 Sqm 55,363.40
Supply and installation of the storage unit as per the reference image. The storage unit item shall be as
per the furniture datasheet. The front elevation area of the storage unit shall be measured for payment.
C-TB-14 (Near Conference table)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture intent
86 document 1.00 No 41,359.50
Supply and installation of the storage unit as per the reference image. The storage unit item shall be as
per the furniture datasheet. The front elevation area of the storage unit shall be measured for payment.
C-SU-58-LI (Main cabin near seating)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture intent
Supply and installation of the storage unit as per the reference image. The storage unit item shall be as
per the furniture datasheet. The front elevation area of the storage unit shall be measured for payment.
Side Table - C-TB-07 (Main cabin, Ante Room)
Approximate Dimensions (LX W X H ): 550 x 400 x
Supply and Installation of side table as per the reference image. The item shall be as per the furniture
Side Table - C-TB-11 (Ante room)
Approximate Dimensions (LX W X H ): 900 x 550 x
Supply and Installation of side table as per the reference image. The item shall be as per the furniture
Side Table - C-TB-11A (Main Office)
Approximate Dimensions (LX W X H ): 900 Dia x 385 H
Supply and Installation of side table as per the reference image. The item shall be as per the furniture
Conference Table - C-TB-12
Approximate Dimension (L x W x H) - 4200 X 1500 X
Supply and Installation of the conference table as per the reference image. The item shall be as per the
furniture data sheet.
Item Description Quantity Unit Rate Amount (in Rs.)
Work station - C-WS-01
Approximate Dimension (L X W X H): 1200 X 700 X
92 Supply and installation of the workstation desk table as per the reference image. The item shall be as 3.00 No 29,694.00
per the furniture data sheet.
Two seater sofa with solid wooden frame and legs - S-SF-02 (main cabin)
Approximate Dimensions (L X W X H): 1800 X 725 X
93 Supply and installation of a two seater sofa as per the reference image. The item shall be as per the 1.00 No 99,819.56
furniture data sheet and fabric as per fabric selection package.
Single Seater Sofa - S-SF-03 (Main cabin)
Approximate Dimensions (LX W X H ): 750 x 725 X
Supply and installation of Single Seater Sofa made as per the reference image. The item shall be as
per the furniture data sheet and fabric as per fabric selection package.
Single seater sofa - S-SF-04 (Ante room)
Approximate Dimension (L X W X H): 790 x 780 x
Supply and installation of single seater sofa as per the reference image. The item shall be as per the
furniture data sheet and fabric as per fabric selection package.
Two seater sofa with solid wooden frame and legs - S-SF-06 (Waiting Room)
Approximate Dimensions (L X W X H): 1800 X 780 X
96 Supply and installation of a two seater sofa as per the reference image. The item shall be as per the 1.00 No 99,819.56
furniture data sheet and fabric as per fabric selection package.
Diwan sofa - S-DI-01 (Ante room)
Approximate Dimension (L X W X H): 2010 x 850 x
Supply and installation of diwan with bolster pillow as per reference image. The item shall be as per the
furniture data sheet and fabric as per fabric selection package.
Partition Screen - E-SI-02 (Main cabin)
Approximate Dimension (L x W x H) - As per Furniture intent document x 50 x As per Furniture intent
Supply and installation of partition screen as per reference image. The item shall be as per the furniture
data sheet. The front/ single side only elevation area of the Partition Screen shall be measured for
Coat Hanger - E-SI-04 (main cabin)
Approximate Dimension (D1 X D2 X H): 480 x 450 x
Supply and Installation of a free standing coat hanger as per reference image. The item shall be as per
the furniture data sheet.
Chair - S-CH-04 (Main cabin)
Approximate Dimension (L X W X H): 560 x 650 x
Supply and installation of a chair made as per reference image. The item shall be as per the furniture
data sheet and fabric as per fabric selection package.
C-TB-10 (Waiting Room-Corner Table)
Approximate Dimension (L x W x H) - As per Furniture intent document x 400 x As per Furniture intent
Supply and installation of the storage unit as per the reference image. The storage unit item shall be as
per the furniture datasheet. The front elevation area of the storage unit shall be measured for payment.
C-TB-13 (Waiting Room-Corner Table)
Approximate Dimension (D x H) - As per Furniture intent document x 450 Dia x As per Furniture intent
Supply and installation of the storage unit as per the reference image. The storage unit item shall be as
per the furniture datasheet. The front elevation area of the storage unit shall be measured for payment.
Chair - S-SF-07 (Waiting)
Approximate Dimension (L X W X H): 600 x 580 x
103 Supply and installation of a chair made as per reference image. The item shall be as per the furniture 3.00 No 38,575.69
data sheet and fabric as per fabric selection package.
TOTAL FOR CUSTOM-MADE CATEGORY:
BOUGHT OUT CATEGORY
Task chair - S-CH-01
Supply and Installation of chair as per reference image, furniture intent document, approved make and
104 model as under. 1.00 No 13,459.87
Godrej : Cross Full Back Knitted Fabric Ergonomic Office Chair (Black Ink)
Main Chair - S-CH-02
Supply and Installation of high back chair as per reference image, furniture intent document, approved
105 make and model as under. 1.00 No 16,543.80
Featherlite: Liberate high back leatherette chair.
Mid Back chair - S-CH-03
Supply and Installation of chair as per reference image, furniture intent document, approved make and
106 model as under. 13.00 No 13,122.63
Godrej: Motion High Back Knitted Fabric Ergonomic Office Chair.
Item Description Quantity Unit Rate Amount (in Rs.)
TOTAL FOR BOUGHT OUT CATEGORY:
TOTAL FOR FURNITURE WORKS:
1. "Procurement of items with aesthetic value and visibility shall be on prior approval of Engineer in
charge for specific area of application."
2. Item shall be executed for all spaces / areas / rooms / buildings etc. with different types of fabrics /
materials as per selection (provided in soft furnishing package document) and as suggested by
engineer in charge.
3. The contractor shall get the approval of each sample of material for curtain / blinds (fabric, PVC,
UPVC slats, etc.), fixing accessories, carpet etc. from the engineer-in-charge before execution for
respective areas.
4. Contractor shall co-ordinate and execute any type of services required in soft furnishing work.
Hand Tufted 100 % wool as per required Tufts per square inch
Supply and stacking of area rug/carpet as per the approved design and colour made out pure wool of
approved quality and specification. There shall be hand tufted construction technique, as per the
specified shape and size, installation, transportation and carriage all complete as per direction of the
engineer-in-charge.
The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools &
tackles of approved make for all floors, all heights, all levels and all places. The contractor shall get the
sample approved by the engineer-in-charge before execution. Design shall be finalized as per design
samples submitted by agency and approved by engineer in charge. The actual laid area shall be
measured for payment without considering any wastage.
Design: Malak Hand Tufted Woolen And Viscose Rug
Make - Obeetee Carpets
Hand Woolen Carpet
Supply and stacking of area rug/carpet as per the approved design and colour made out pure wool of
approved quality and specification.
The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools &
tackles of approved make for all floors, all heights, all levels and all places. The contractor shall get the
sample approved by the engineer-in-charge before execution. Design shall be finalized as per design
108 samples submitted by agency and approved by engineer in charge. The actual laid area shall be 8.00 Sqm 6,719.78
measured for payment without considering any wastage.
These carpets are washable.
Design: Victoria Hand Tufted Woolen Rug
Make - Obeetee Carpets
TOTAL FOR CARPET WORKS:
Cellular shades - Motorized
Providing and fixing of Cellular shades with motorized operating as per the curtain the reference image.
Cellular shades selection as per the reference image/ intent. The actual elevation area of curtains in a
closed condition shall be measured and paid. The rate shall be applicable for all heights and all floors.
Cellular shades - Manual
Providing and fixing of Cellular shades with Manual (chain) operating as per the curtain the reference
110 image. Cellular shades selection as per the reference image/ intent. The actual elevation area of 15.00 Sqm 2,959.86
curtains in a closed condition shall be measured and paid. The rate shall be applicable for all heights
and all floors.
TOTAL FOR CURTAIN WORKS:
Providing, transporting and arranging / fixing in position various Wooden Frame section of any size
made of approved teakwood / hardwood and polish of approved shade and finish including approved
111 carving, inlay, hand painting, engraving, decorative metal works or any other type of decorative works 5.00 Sqm 11,783.32
of any material and any finish. Including fixing clamps, mounting material, backing material, glass, any
other hardware, as per approved material / finish, to the various areas as per direction of Architect and
Engineer In-charge.
TOTAL FOR FRAMED ART WORKS:
ACCESSORIES WORKS
Item Description Quantity Unit Rate Amount (in Rs.)
The contractor shall have to co-ordinate for the below mentioned loose accessories and make
arrangements as per drawing and as suggested by Engineer in charge.
The contractor shall arrange samples of all type of accessories (with different material and design) for
review and approval. Contractor shall arrange mock-up for specific area with collected samples as
suggested by Engineer in charge.
After reviewing the mock-up, any modifications/ alterations suggested by the Engineer in charge shall
be incorporated. This process shall continue until final approval of the mock-up is received from the
the Engineer in charge.
The contractor shall have to shift or re-arrange the loose accessories as per the requirement of the
Engineer in charge.
The rate shall be inclusive of charges for necessary equipments (tools and tackles) needed for shifting
the accessories anywhere within the entire site, packing, un-packing, re-packing, protecting, cleaning,
maintaining, storing, etc complete as suggested by Engineer in charge. The rate shall be applicable for
all height, all floors.
The contractor will have to co-ordinate for the loose accessories and make arrangements to shift the
loose accessories as per the requirement of the Engineer in charge.
Providing, transporting and arranging / fixing in position various Dispenser to the various areas as per
112 direction of Engineer Incharge- 5.00 No 1,323.50
Aroma dispensers (Automatic) - AD1
Providing, transporting and arranging / fixing in position dust Bin to the various areas as per direction of
113 Engineer Incharge - 3.00 No 1,627.87
Providing, transporting and arranging / fixing in position Tea coasters / Tea Set to the various areas as
114 per direction of Engineer Incharge -(including stand of the coaster as per selection) 26.00 No 496.31
Tea coasters - TC4
Providing, transporting and arranging / fixing in position Tissue box and Tissue Box Covers to the
115 various areas as per direction of Architect and Engineer Incharge - 2.00 No 4,028.84
Tissue Box - TI1
Providing, transporting and arranging / fixing in position Pen Pencil Holder to the various areas as per
116 direction of Engineer Incharge - 1.00 No 2,046.77
Pen / Pencil holders - TS2
Providing, transporting and arranging / fixing in position Desk Organizer to the various areas as per
117 direction of Engineer Incharge - 1.00 No 1,887.69
Desk organizer - TS3
Providing, transporting and arranging / fixing in position tray to the various areas as per direction of
118 Engineer Incharge - 1.00 No 2,119.94
Providing, transporting and arranging / fixing in position Table Vases with flowers to the various areas
119 as per direction of Architect and Engineer Incharge - 1.00 No 3,604.64
Table Vase - VA6
Providing, transporting and arranging / fixing in position Wall Clocks to the various areas as per
120 direction of Architect and Engineer Incharge - 2.00 No 2,911.07
Wall Clock - WC2
TOTAL FOR ACCESSORIES WORKS:
Item no Item Description Unit Qty. Rate
Electrical Works
Distribution BoardMCB 's and its Accessories
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
(A) 6 to 32 Amp. Cat.III
Providing & erecting 415V MCB Four Pole for Motor & Inductive Load (CCurve) having
KA breaking capacity & confirms to IS:8828 in existing box having following capacity (b)
123 PlasticenclosurefittedwithDINrailsuitableforincorporating Three /Four nos. MCB No. 2 107.13
Total Carried Over to Summary
Cable Tray & Racway
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking
of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of
concrete of screed water with all accessories,Junction Box,Joints as required and
124 demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per Mtr 30 1,034.36
instruction of engineer incharge having following size of dimensions and No of
compartments (W x D x T) Cat-III
[11] 225mm x 38mm x 1.6mm with Three Compartments
125 [10] 150mm x 38mm x 1.6mm with Three Compartments Mtr 25 724.36
126 [7] 50mm x 38mm x 1.6 mm with One Compartments Mtr 15 282.18
Supplying & Fixing of 250mm (L) x 250mm (W) x 50 – 80 (H) / 60- 75 (H) / 65 - 90(H)
adjustable height floor Cross Over Type junction box made out of pre galvanized sheet
min. 1.6mm thick base, cover & min. 2.0 mm thick for Lid with Electrostatic polyster epoxy
coating or 275 GSM coating mass. minimum 8mm Trap lid to be provide to acodomate the
specified flooring. The base of junction box should have pre punched / champhered
knockouts on all four sides to accomodate trunking from a minimum 50mm to maximum
225mm width & 38mm height. The system must have smooth curved die cast pillars for
ease of pulling cables. The cross over boxes should have flyover units made of abs plastic
or metal to route and distribute power, data & other cables. Cover of junction box should be
complete as required as per detail specificaton.
Supplying & Fixing of 150mm (L) x 150mm (W) x 50 – 80 (H) / 60- 75 (H) / 65 - 90(H)
adjustable height floor junction box made out of pre galvanized sheet min. 1.6mm thick
base, cover & min. 2.0 mm thick for Lid with Electrostatic polyster epoxy coating or
GSM coating mass. minimum 8mm Trap lid to be provide to acodomate the specified
flooring. The base of junction box should have pre punched / champhered knockouts on all
four sides to accomodate trunking from a minimum 50mm to maximum 225mm width &
38mm height. The system must have smooth curved die cast pillars for ease of pulling
cables. The cross over boxes should have flyover units made of abs plastic or metal to
route and distribute power, data & other cables. Cover of junction box should be complete
as required as per detail specificaton.
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof confirming BS with necessary end
129 caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and Mtr 20 405.28
measuring of following sizes
(2) 100 mm x 50 mm trunking
Total Carried Over to Summary
Internal Wiring
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade HFFR insulated multi strand copper wires up to 10 mtr length
in below type of pipe erected with 6A Modular type switch / bell push & accessories and
earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Item no Item Description Unit Qty. Rate
Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade HFFR insulated multi strand
copper wires, in below type of pipe to be erected complete with earth continuity and
necessary connection with primary light with accessories erected on Metal / PVC /
wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.
(b) with 16 swg(1.6 mm thick) HGS metal conduit pipe and accessories painted black
erected flushed on wall/ceiling complete. Cat-III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked 1.1 KV grade HFFR insulated multi strand copper
wires erected in below type of pipe with 6A Modular type switches and following type of
accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
One 6 A x 5 pin 250 Volt socket outlet point controlled by one 6 A switch located on switch
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade HFFR insulated multistrand copper wires, in following type of to be
erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin
Plug/Socket erected on PVC / Metallic box covered with appropriate front plate modules
134 erected on / in wall / ceiling as per pipe erected with following type of accessories. No. 35 549.59
[I] For 6A Plug/Socket and 6 A switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC /
135 Metallic box, single mounting base frame covered with textured / metallic front plate No. 7 239.30
modules erected on / in wall / ceiling with following type accessories. Cat.iii
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade HFFR insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug /Socket erected
on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in
wall / ceiling as per pipe erected with following type of accessories.
[II] For 16A Plug/socket and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade HFFR insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug/Socket erected
on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in
137 wall / ceiling as per pipe erected with following type of accessories. No. 5 880.59
[III] For 16A Plug/Socket and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm (
green) earthing wire from mcb d b board.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed by Engineer In charge.
(20) Modular Buzzer-Cat.III
Supplying and fixing of following sizes of steel conduit along with accessories in
surface/recess including painting in case of surface conduit, or cutting the wall and making
good the same in case of recessed conduit as required.
Total Carried Over to Summary
Light Fixtures & Fans
Item no Item Description Unit Qty. Rate
Supplying installation testing & commissioning of approx 28W suspended/surface mounting
type LED 4 feet Luminaire, IP 20 ,colour temperature 4000 to 6500 K having efficiency not
less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum housing, inbuilt electronic
143 driver, suspension arrangement for pendent mounting through suspension bracket No. 6 4,336.56
including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed copper conductor cable
and earthing etc. as required. (Any one make of REGENT(slash s) - LED 0561-28W, Light
Forms-Five bow h -28w / or approved equivalent)
Supplying installation testing & commissioning of approx 20Watt Light Wide 55° Beam
Angle recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K
having efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum
housing, inbuilt electronic driver, suspension arrangement for pendent mounting through
suspension bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed
copper conductor cable and earthing etc. as required.(Any one make of REGENT(aston) -
LED 3138-20W, Endo Ledz -Glare less-19.8W, Light forms indus155-20W/ or approved
Supplying installation testing & commissioning of approx 10Watt Light Wide 38° Beam
Angle recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K
having efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum
housing, inbuilt electronic driver, suspension arrangement for pendent mounting through
suspension bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed
copper conductor cable and earthing etc. as required. (Any one make of REGENT(aston) -
LED 3138-10W, Endo Ledz -Glare less-8W, Light forms Leo99-10.2W/ or approved
Supplying installation testing & commissioning of approx 24Watt/mt (900∅) pendant LED
Down lighter Luminaire, IP 20 ,colour temperature 4000 to 6500 K having efficiency not
less than 100 lm/W, CRI ≥ 80 ,THD less than 20%, Extruded Aluminum / CRCA / Metal
146 housing / Thermoconductive plastic housing, inbuilt electronic driver, including 3 core 1.5 No. 3 39,014.91
sq.mm FR PVC insulated and PVC sheathed copper conductor cable and earthing etc. as
required.(Any one make of REGENT(volt) - 24W/m, Light forms- Moon band 40-25W/m/ or
approved equivalent)
Supplying installation testing & commissioning of approx 8Watt Light Wide 24° Beam Angle
recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K having
efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum housing, inbuilt
147 electronic driver, suspension arrangement for pendent mounting through suspension No. 6 6,303.79
bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed copper conductor
cable and earthing etc. as required. (Any one make of REGENT(aston) - LED 3138-8W,
Endo Ledz -Glare less-8W, Light forms Leo99-7.3W/ or approved equivalent)
Supplying installation testing & commissioning of approx 15Watt Light Wide 38° Beam
Angle recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K
having efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum
housing, inbuilt electronic driver, suspension arrangement for pendent mounting through
suspension bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed
copper conductor cable and earthing etc. as required. (Any one make of REGENT(aston) -
LED 3138-15W, Endo Ledz -Glare less-15W, Light forms Leo99-14.2W/ or approved
Supplying & erecting single phase approved make industrial exhaust fan suitable for
medium duty ring mounted low noise operation suitable for medium duty having following
149 dia size and maximum speed in RPM No. 1 3,937.99
[E] 450 mm dia 1400 RPM
Supplying & erecting electro galvanised G.I. wire micro mesh jali cover of grade
150 required size with suitable wooden frame duly fitted in wall outside of exhaust fan for insect Sq. Mtr 1.5 628.51
Total Carried Over to Summary
151 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. Kg. 5 77.70
Total Carried Over to Summary
Electrical Miscellaneous
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction
152 boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved Mtr. 30 23.06
manner as directed
Item no Item Description Unit Qty. Rate
Total Carried Over to Summary
ICT Distribution System For Data And Voice Infra
PVC Conduits & Accessories
Supplying and fixing of following sizes of medium class PVC conduit along with accessories
156.00 in surface/recess including cutting the wall and making good the same in case of recessed MTRS 33.00 32.06
conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories
in surface/recess including cutting the wall and making good the same in case of recessed
conduit as required.
CAT6A UTP Components for Data/LAN & Wi-Fi
Supply and laying of specified make UTP CAT6A LSZH cable in prelaid PVC conduits /
pipes / raceway, but without the cost of raceway or pipe. (The cable is to be drawn from
158.00 individual workstation/device/desktop area to the central communications/server room. MTRS 638.00 71.05
Terminations to be carried out in any intermediate wiring closets/telecom closets by way of
racks/MDF/IDF)_DATA, VOICE, CCTV Cabling as per technical specification etc. as
Supply, Installation, Testing & Commissioning of Single UTP CAT6A Tool less RJ-45 I/O
and RJ45 Information outlet with insertion cycle (in & out) upto 2500 times (I/O) of specified
make inclusive of termination of CAT6A cable at each IO at Equipment & Rack Side as per
technical specification etc. as required.
Supply, Installation, Testing & Commissioning of CAT6A UTP RJ-45 Patch Cords Solid
160.00 Conductor 1 mtr. for data (Hub Side)-Data, Number of Insertion upto 2500 Duty Cycle as EACH 34.00 318.15
per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of CAT6A UTP RJ-45 Patch Cords Solid
161.00 Conductor 2 mtr. for data (Hub Side)-Data, Number of Insertion upto 2500 Duty Cycle as EACH 34.00 344.66
per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of UTP CAT6 / CAT6A Gigabit Modular
Unloaded Patch Panel for 24 ports in 1U form factor as per the tender specifications, with
162.00 universal A/B labeling and 110 connector terminations on rear of panel allowing for quick EACH 2.00 3,976.88
and easy installation of 22 to 24 AWG cable.-Data includes Computer Point, CCTV, ACS,
CCTV, Wi-Fi as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Singlex Face Plate for mounting CAT6A
IO with required back box as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Duplex faceplate for mounting CAT6A IO
with required back box as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 19-inch 12 Port LIU, rack mounted , Fully
165.00 loaded with 2 X 06 Ports Adaptor Connector Panel & with Splice Tray, inclusive of all EACH 2.00 11,665.50
mechanical accessories with out pigtail, as per technical specification etc. as required.
Supply, Splicing,Testing & Commissioning/ Termination of LC-Style Pigtail, 9/125,
Singlemode, 1.5 meter, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of LC-LC single mode duplex fiber optic
patch cord 3mtr, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 15U (600W X 600D)MM Wall mount
closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with
shelf. Casters & 2 nos vertical power strip with std, as per technical specification etc. as
Supplying , fabricating and installation of various sizes SS race way / junction
boxes/clamps/ hangers / enclosure for ELV Fixtures/ for cable trays / Base for Display
mounting / Flange for Display etc. made out of 14 gauge sheet/Angle/Flat/rod/ channel/box
section etc with all necessary accessories like bend, junction boxes, coupler, supporting
169.00 clamps, elbows, hardware, anchor fasteners complete with Cutting, welding, grinding, KGs 50.00 477.23
finishing necessory grouting,cementing, plastering etc.. All the necessary fabrication
required will be included in the scope of contractor. Scope also includes two coat of primer
and two coat of paining of each items on all the sides complete in all respect as instructed
by Architect / project in charge.
Total Carried Over to Summary
Cable Television Distribution System
Supplying and Laying of Un-Armoured RG 11 Co-Axial TV cable in prelaid conduit as per
technical specification etc. as required.
Item no Item Description Unit Qty. Rate
Supply, Installation, Testing and Commissioning of one television point to be done with
171.00 television outlet socket and box of the APPROVED make, as per technical specification EACH 3.00 152.10
etc. as required.Cat.|||
Total Carried Over to Summary
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02_Vol-I-B_SBD_GUDC_Works_GCC_Interior_UDUHD_AHM.pdf
03_Vol-II-Part-I_Tech_Spec_Civil_and_Make_Interior_UDUHD_AHM.pdf
04_Vol-II-Part-II_Tech_Spec_Electrical_and_Make_Interior_UDUHD_AHM.pdf
05_Vol-II-Part-III_Tech_Spec_ELV_and_Make_Interior_UDUHD_AHM.pdf
06_Vol-II_Part-IV_Gen_Tech_Spec_Civil_R_and_B.pdf
07_Vol-III_SBD_GUDC_Works_Price_Bid_Interior_UDUHD_AHM.pdf
10_DMO_2941_01-Apr-2026_744.pdf
Revised_09_Vol-IV_Bid_Drawings_Interior_UDUHD_AHM.pdf
08_Vol-III_SBD_GUDC_Works_Schedule-B_Interior_UDUHD_AHM.pdf
01_Vol-I-A_SBD_GUDC_Works_Tech_Interior_UDUHD_AHM_27-06-2026.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .