Loading…
Loading…
Tender Value
₹41.0 Cr
EMD Value
₹41.0 L
Closing Date
8 Sept 2026, 6:00 pm
Add.City Engineer Building project
CONSTRUCTION OF FIRE STATION & STAFF QUARTERS AT RAMOL-HATHIJAN (TP NO 76, FP NO 115-1) IN RAMOL WARD, EAST ZONE, UNDER BUILDING PROJECT DEPARTMENT, AMC
337221
2026-2027
Open
Miscellaneous Works
Works
Ahmedabad
1 document required · 0 mandatory · 1 optional
₹18,000
Municipal Commissioner, Ahmedabad
₹41.0 L
20 Aug 2026
20 Aug 2026
20 Aug 2026
8 Sept 2026
20 Aug 2026
I/We am/are willing to carry out work at __________% above / below (should be written in figures and words) the estimated cost
mentioned above. The amount of my/our tender works out as under
Estimated cost put to tender : Rs. 41,01,86,912.24 Estimated cost put to tender : Rs.
Add_____% Above : Rs ___________ Deduct_____% Below : Rs ___________
Total : Rs___________ Total : Rs___________
Note-1 The contractor should get the sample of material in respect of quality and source of supply or manufacturer approved by
Consultant / AMC in all cases. All such approved samples should be kept at site in the custody of EIC-CMC/PMC/AMC. The tests
for the make in external laboratory in presence of CMC/PMC/AMC to be carried out by Contractor at his own cost as per relevant
latest codes. Reinforcement steel & cement original purchase bills shall be produced to CMC/PMC/AMC as and when asked for.
Note-2 Rate includes for any height, any level, any lead & lift and as per directed by EIC.
Note-3 For Fire Fighting System Autoglow Mandatory Signages and NOC Process and charges of NOC are included.
Signature of Contractor Additional City Engineer
Seal Building Project
Date Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under
Building Project Department.
SUBESTIMATE - 01 : STRUCTURAL WORK
S. NO. ITEM DESCRIPTION AMOUNT
1 STRUCTURAL WORK
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under Building Project Department.
BOQ FOR SUBESTIMATE - 01 : STRUCTURAL WORK
Item no. Item Description Unit Rate Total Qty. Amount
Excavation for foundation up to 1.5 m DEPTH including sorting out and stacking of useful material sand disposing off
the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation up to 1.5 m TO 3.0M DEPTH including sorting out and stacking of useful material sand
disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation up to 3.0M TO 5.0M DEPTH including sorting out and stacking of useful material sand
disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding
20cm. In depth consolidating each disposited layer by ramming and watering.
Providing and laying cement concrete 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregates 20mm nominal
size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying in position Ready Mixed M- 250 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
6 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 4,853.56 681.63
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 450 kg ) (GRADE SLAB)
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
7 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,043.66 1,457.46
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 475 kg ) (Foundation)
Bored cast-in-situ M30 grade R.C.C. pile excluding reinforcement complete as per drawing and technical
specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter- 300 mm)
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
9 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,245.98 1,802.32
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 475 kg ) (RCC BEAM) for all floor
Item no. Item Description Unit Rate Total Qty. Amount
Providing and laying in position Ready Mixed M-450 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
10 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,450.46 344.90
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 550 kg ) (RCC COLUMN) for all floor
Providing and laying in position Ready Mixed M-400 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
11 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,395.77 234.55
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 525 kg ) (RCC COLUMN) for all floor
Providing and laying in position Ready Mixed M-350 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
12 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,343.26 411.82
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 500 kg ) (RCC COLUMN)
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
13 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,245.98 21.84
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 475 kg ) (RCC COLUMN)
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
14 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,245.98 787.22
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 475 kg ) (RCC WALL) for all floor
Item no. Item Description Unit Rate Total Qty. Amount
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
15 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,245.98 2,387.57
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 475 kg ) (RCC SLAB) for all floor
Providing and laying cushioning layer on R.C.C. Slab consisting of 75mm thick lime, concrete using brick aggregate
of 20mm nominal size mortar compresing of 1-Lime : 2- fine sand
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
17 excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended CUM 5,245.98 148.80
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 500 kg ) (STAIRCASE)
Providing and laying design mix cement concrete of M‑30 grade for RCC road, using cement content as per
approved mix design, coarse sand and graded stone aggregate of 40 mm nominal size, batching and mixing at site /
RMC plant, laying, spreading and compacting mechanically using needle vibrators and surface vibrators, followed by
vacuum dewatering process with floor hardener, finishing by floating and brooming with wire brush, levelling to
18 required slope/camber and textured finish, including providing steel formwork with sturdy MS channel sections, CUM 6,207.00 286.29
curing, forming contraction, expansion, construction and longitudinal joints by groove cutting machine, and providing
and filling joints with approved joint filler and sealants, complete all as per IRC specifications and directions of
Engineer‑in‑Charge.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix
macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in
19 uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting CUM 1,056.45 143.15
with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and
directions of Engineer-in-Charge.
Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a
mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in
20 uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory roller to CUM 953.49 214.72
achieve the desired density, complete as per specifications and directions of Engineer-in-Charge
With material conforming to Grade-I (size range 75mm to 0.075 mm) having CBR Value -
Providing and laying TMT Bar FE-500D reinforcement for R.C.C. work and straightening, cutting, bending, binding &
21 placing in position completed upto all floor all level as per I.S. Standard. complete. As per drawings and design kg 79.51 10,90,942.52
supplied by architect and instruction given by authority and E.I.C.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of
22 the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns SQM 171.68 942.68
etc. and Mass concrete.
Item no. Item Description Unit Rate Total Qty. Amount
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of
23 the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) SQM 297.68 9,712.27
Square Rectangular Polygonal in plan.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (G) Columns, Pillars, Posts
and struts. (1) Square, Rectangular or polygonal in plan.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M
25 between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii) Height SQM 682.01 71.21
more than 5.0M.and upto 6.0 M.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (G) Columns, Pillars, Posts
and struts. (1) Square, Rectangular or polygonal in plan.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of
27 the same for in situ reinforced concrete and plain concrete work in. (C) Vertical surface such as walls (any SQM 229.95 6,433.77
thickness) partitions and the like including attached buttresses & string course & the like.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (C) Vertical surface such as
walls (any thickness) partitions and the like including attached buttresses & string course & the like.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M
29 between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii)Height SQM 386.48 - -
more than 5.0 M.and upto 6.0 M.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (C) Vertical surface such as
walls (any thickness) partitions and the like including attached buttresses & string course & the like.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of
31 the same for in situ reinforced concrete and plain concrete work in. (B) Flat surfaces such as soffits of supspened SQM 252.00 12,626.81
floors slabs Landings and the like. (1) Floors etc. upto 200 mm in thickness.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (B)Flat surfaces such as
soffits of slabs Landings and the like. (1) Floors etc. upto 200mm in thickness.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of
33 the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam SQM 192.15 22,868.27
Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (H)(1) Sides and soffits of
Beams, Beam Haunchingscantilevers Girders, Bressumers and Lintels not exceeding 1 M. in Depth.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of
35 the same for in situ reinforced concrete and plain concrete work in. M) Staircase with slopingor SQM 242.55 787.45
stepped soffits including risers and stringers excluding landing.
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (M)Staircase with sloping or
stepped soffits including sisers and stringers excluding landing.
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing HILTI rebar (10mm diameter).The work shall be carried out by the technical workmens/agency
37 approved by the manufacturer and under technical supervision including all materials,tool tackles, labour No. 465.00 30.00
etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI rebar (12mm diameter).The work shall be carried out by the technical workmens/agency
38 approved by the manufacturer and under technical supervision including all materials,tool tackles, labour No. 608.00 30.00
etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI rebar (16mm diameter). The work shall be carried out by the technical workmens/agency
39 approved by the manufacturer and under technical supervision including all materials,tool tackles, labour No. 1,202.00 30.00
etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI rebar (20mm diameter). The work shall be carried out by the technical workmens/agency
40 approved by the manufacturer and under technical supervision including all materials,tool tackles, labour No. 2,063.00 30.00
etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI Anchor (10mm diameter). The work shall be carried out by the technical
41 workmens/agency approved by the manufacturer and under technical supervision including all materials,tool tackles, No. 846.00 30.00
labour etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI Anchor (12mm diameter). The work shall be carried out by the technical
42 workmens/agency approved by the manufacturer and under technical supervision including all materials,tool tackles, No. 1,245.00 30.00
labour etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI Anchor (16mm diameter). The work shall be carried out by the technical
43 workmens/agency approved by the manufacturer and under technical supervision including all materials,tool tackles, No. 2,295.00 30.00
labour etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing HILTI Anchor (20mm diameter). The work shall be carried out by the technical
44 workmens/agency approved by the manufacturer and under technical supervision including all materials,tool tackles, No. 4,451.00 30.00
labour etc.complete as per drawings and instruction given by authority and E.I.C.
Providing and fixing UPVC/PVC sleeves of required diameter (compressive strength ≥ 6 kg/cm²) up to 0.5 m long,
cast in RCC slabs, beams, walls, etc., for services and utilities, complete. 1)50mm dia.
Providing and fixing UPVC/PVC sleeves of required diameter (compressive strength ≥ 6 kg/cm²) up to 0.5 m long,
cast in RCC slabs, beams, walls, etc., for services and utilities, complete. 1)75mm dia.
Providing and fixing UPVC/PVC sleeves of required diameter (compressive strength ≥ 6 kg/cm²) up to 0.5 m long,
cast in RCC slabs, beams, walls, etc., for services and utilities, complete. 1)110mm dia.
Providing and fixing in position high-grade PVC water stopper of size 250 mm wide × 10 mm thick at construction /
48 expansion joints in underground water tanks, STP structures and similar water-retaining structures, complete as per Rmt 311.00 1,513.00
drawings and directions of Engineer-in-Charge
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under
Building Project Department.
SUBESTIMATE - 02 : CIVIL WORK
S. NO. ITEM DESCRIPTION AMOUNT
B MASONARY WORK
C PLASTER & CLADDING WORK
D FLOORING & PAVING WORK
E PAINTING AND POINTING
F CEILING & PARTITION WORK
G WATER PROOFING WORK
H DOOR AND WINDOW WORK
J MISCELLENEOUS
K FURNITURE WORK
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under Building Project Department.
BOQ FOR SUBESTIMATE - 02 : CIVIL WORK
Item no. Item Description Unit Rate Total Qty. Amount
Earthwork for embankment including breaking clods, dressing with all lead and lift and including watering rolling
1 and consolidation of subgrade in layers at O.M.C. to required dry density including filling the depression which CUM 151.00 500.00
occur during the process using power roller 8T to 10T. From Borrow area as per lead available.
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering,
ramming and consolidating etc. complete.
Conveyance charge of earth, lime, murrum, building rubbish, manure, garbage, sludge, excavated rock, fly ash,
aggregates of any kind executed outside the road site. Rate also includes spreading & levelling etc complete.
Internal conveyance above 50 mt done within the work site is not payable. (R&B 2023-24 Statement No.5
(3.2.1.A.2. Earth) Page no.5
3 Lead From 5 Km to 10 Km. CUM 417.67 7,365.00
4 Lead From 10 Km to 15 Km. CUM 425.87 7,365.00
5 Lead From 15 Km to 25 Km. CUM 433.32 7,365.00
TOTAL OF EARTH WORK
B MASONARY WORK
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
Extra for brick work in superstructure above plinth level upto floor two level (B) Conventional
Basement Cu.m 4,283.91 40.00
Ground Floor Cu.m 4,283.91 355.00
1st Floor Cu.m 4,283.91 285.00
Extra for brick work in superstructure above floor two level Item No. 1(6.12) (B) Conventional
2nd Floor Cu.m 4,324.00 415.00
3rd Floor Cu.m 4,364.09 289.00
4th Floor Cu.m 4,404.18 175.00
5th Floor Cu.m 4,444.27 178.00
6th Floor Cu.m 4,484.36 175.00
7th Floor Cu.m 4,524.45 175.00
8th Floor Cu.m 4,564.54 178.00
9th Floor Cu.m 4,604.63 175.00
10th Floor Cu.m 4,644.72 175.00
Terrace / Mumty Cu.m 4,684.81 134.00
(i) Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm.
in Cement mortar 1:4 (1-Cement : 4 -coarse sand ) in foundation and plinth (B) Conventional : Extra for brick work
9 in superstructure above floor two level Item No. 5 (B) Coventional
Ground Floor SQM 646.70 59.00
1st Floor SQM 646.70 480.00
Item no. Item Description Unit Rate Total Qty. Amount
Extra for brick work in superstructure above floor
two level Item No. 5 (B) Coventional
2nd Floor SQM 652.64 1,041.00
3rd Floor SQM 692.73 493.00
4th Floor SQM 732.82 448.00
5th Floor SQM 772.91 448.00
6th Floor SQM 813.00 448.00
7th Floor SQM 853.09 448.00
8th Floor SQM 893.18 448.00
9th Floor SQM 933.27 448.00
10th Floor SQM 973.36 448.00
Terrace / Mumty SQM
Providing and filling sunken portion with light weight AAC block bats of size 40–60 mm, including placing, packing
and filling voids with cement sand mortar 1:5 (1 cement : 5 coarse sand) admixed with integral waterproofing
11 compound conforming to IS 2645, properly compacted and levelled, and finishing with 25 mm thick cement sand cum 6,407.00 117.00
mortar screed 1:4 laid to required levels and slopes, smooth and ready to receive floor finish, complete as
TOTAL OF MASONARY WORK
C PLASTER & CLADDING WORK
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two
level and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand)
Basement SQM 127.58 1,714.00
Ground Floor SQM 127.58 2,430.00
1st Floor SQM 127.58 2,824.00
Extra over items for interior plastering above floor two level for every
additional storey height. (1) Single coat plaster
2nd Floor SQM 150.74 3,450.00
3rd Floor SQM 173.90 1,928.00
4th Floor SQM 197.06 1,928.00
5th Floor SQM 220.22 1,928.00
6th Floor SQM 243.38 1,928.00
7th Floor SQM 266.54 1,928.00
8th Floor SQM 289.70 1,928.00
9th Floor SQM 312.86 1,928.00
10th Floor SQM 336.02 1,928.00
Terrace / Mumty SQM
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm
14 thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand)
Ground Floor SQM 297.68 3,332.00
1st Floor SQM 297.68 2,236.00
2nd Floor SQM 297.68 3,233.00
Item no. Item Description Unit Rate Total Qty. Amount
Extra over items for interior plastering above floor two level for every additional storey height.(2) Two coat plaster
3rd Floor SQM 324.14 2,263.00
4th Floor SQM 350.60 1,836.00
5th Floor SQM 377.06 1,859.00
6th Floor SQM 403.52 1,836.00
7th Floor SQM 429.98 1,836.00
8th Floor SQM 456.44 1,859.00
9th Floor SQM 482.90 1,836.00
10th Floor SQM 509.36 1,836.00
Terrace / Mumty SQM 535.82 1,135.00
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
16 plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand)
Basement SQM 155.61 14.00
Ground Floor SQM 155.61 226.00
1st Floor SQM 155.61 301.00
Extra over for interior plastering above floor two level for every
additional storey height. (1) Single coat plaster
2nd Floor SQM 178.77 571.00
3rd Floor SQM 201.93 195.00
4th Floor SQM 225.09 195.00
5th Floor SQM 248.25 195.00
6th Floor SQM 271.41 195.00
7th Floor SQM 294.57 195.00
8th Floor SQM 317.73 195.00
9th Floor SQM 340.89 195.00
10th Floor SQM 364.05 195.00
Extra over items for plastering on ceilings and sofits of stairs upto floor two level instead of plastering on walls.
18 Extra over for finishing with a floating coat of neat cement slurry
Basement SQM 227.91 2,043.00
Ground Floor SQM 227.91 1,226.00
1st Floor SQM 227.91 1,104.00
Extra over for plastering on ceiling and soffits of stairs above floor two level for every additional storey height.
19 Extra over for finishing with a floating coat of neat cement slurry
2nd Floor SQM 296.75 888.00
3rd Floor SQM 365.59 765.00
4th Floor SQM 434.43 690.00
5th Floor SQM 503.27 690.00
6th Floor SQM 572.11 690.00
7th Floor SQM 640.95 690.00
Item no. Item Description Unit Rate Total Qty. Amount
8th Floor SQM 709.79 690.00
9th Floor SQM 778.63 690.00
10th Floor SQM 847.47 690.00
Terrace / Mumty SQM 916.31 108.00
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior
20 plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand). Extra
over items for finishing with a floating coat of neat cement slurry.
Basement SQM 203.34 119.00
Ground Floor SQM 203.34 474.00
1st Floor SQM 203.34 474.00
Extra over for interior plastering above floor two level for every additional storey height.(2) Two coat plaster. Extra
21 over items for finishing with a floating coat of neat cement slurry.
2nd Floor SQM 277.53 601.00
3rd Floor SQM 351.72 403.00
4th Floor SQM 425.91 403.00
5th Floor SQM 500.10 403.00
6th Floor SQM 574.29 403.00
7th Floor SQM 648.48 403.00
8th Floor SQM 722.67 403.00
9th Floor SQM 796.86 403.00
10th Floor SQM 871.05 403.00
Terrace / Mumty SQM 945.24 119.00
WET CLADDING POLISHED GRANITE : Providing and fixing machine cut, composite patterned wall wet
cladding out of 18-20mm thick mirror polish granite machine cut, machine polished to walls and columns. Stone
fixed with required stainless steel pins / dowels / cramps including drilling holes, making notches etc. for
22 securedly fixing with pins / cramps to wall. Stone fixed in position with approved readymix ploymer based SQM 4,546.00 332.00
adhesive in line and level and in pattern as shown in the drawing. Joints cleaned, grouted with approved ready
made ploymer modified grout or cured and cleaned, further to include required double legged independent
scaffolding etc. complete to the satisfaction of the EIC.
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer
mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying
cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1
23 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per SQM 647.00 321.00
approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone
chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall
be made separately).
TOTAL OF PLASTER & CLADDING WORK
Item no. Item Description Unit Rate Total Qty. Amount
D FLOORING & PAVING WORK
Granite Flooring - Leather Finish : Providing and laying lether finish Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid
24 and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade SQM 1,921.00 1,417.00
including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
lether finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Granite Skirting / Riser / vertical - Leather finish : Providing and laying Granite stone slab 25mm thick in risers
of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed
25 with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. SQM 2,323.00 30.00
Granite Flooring - Polished : Providing and laying Polished Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with
18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and
26 jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade SQM 2,250.00 576.00
including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished granite stone slab of colour black, cherry/ruby red or equivalent.
Polishe Kota Stone Flooring : Providing and laying polished Kota stone slab flooring over 20mm (Average)
27 thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 laid over and jointed with grey cement SQM 1,085.48 419.00
slurry including rubbing and polishing etc. complete. (B) 30 mm thick
Polishe Kota Stone Skirting / Riser / vertical : Providing and laying polished kota stone slab 25mm thick in
risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and
28 jointed with gray cement slury mixed with SQM 1,176.03 106.00
pigment to match the shade of slab including rubbing and polishing etc. complete.
Vitrified Tile Flooring - polished : P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material
29 including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing SQM 1,261.58 5,183.00
& cleaning the surface etc. complete for shade as per architect/client
Vitrified Tile Flooring - antiskit : P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material
30 including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing SQM 1,383.99 1,129.00
& cleaning the surface etc. complete for antiskit
Vitrified Tile Skirting / Dado / Vertical (Rooms) : Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24''
31 in skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3- coarse sand) and jointed with SQM 1,130.15 3,029.00
white cement slurry
Ceramic Tile Flooring : Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid
32 on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white SQM 960.47 2,124.00
Ceramic Tile Skirting / Dado / Vertical : Providing and layingCeramic tiles 6mm thick in skrting risers of steps
33 and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry SQM 1,028.11 145.00
Item no. Item Description Unit Rate Total Qty. Amount
Granite Skirting / Riser / vertical - Polished : Providing and laying GRANITE STONE SLAB 25mm thick in
risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and
34 jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. SQM 2,511.00 253.00
Granite Treads - Polished : 'Providing and fixing 20mm thick approved up to 600mm wide polish finish Granite
stone treads of length of step and machine cut, machine polished. Treads to be rounded at front and all exposed
edges machine polished. Further treads to have edge polished chamfering with 3 nos. (6mm x 3mm deep)
35 grooves on top at front or as detailed in drawing for antiskid effect as shown in the drawing. Treads fix to be using SQM 4,113.00 319.00
approved adhesive over cement concrete screed joints grouted with approved matching coulour grout,, curing,
cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge.
Granite Treads - Leather Finish : 'Providing and fixing 20mm thick approved up to 600mm wide leather finish
Granite stone treads of length of step and machine cut, machine polished. Treads to be rounded at front and all
exposed edges machine polished. Further treads to have edge polished chamfering with 3 nos. (6mm x 3mm
36 deep) grooves on top at front or as detailed in drawing for antiskid effect as shown in the drawing. Treads fix to be SQM 3,641.00 50.00
using approved adhesive over cement concrete screed joints grouted with approved matching coulour grout,,
curing, cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge.
Polished Granite Coping : Providing and fixing premoulded and prefinished, machine cut polished 18-20 mm
thick granite stone for coping, parapet top and similar locations of required size, approved shade, colour and
37 texture laid using approved adhesive over cement concrete screed (paid separately), joints grouted with approved SQM 6,980.00 634.00
matching colour grout, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high
gloss finish etc. complete at all levels, as per sample approved by Engineer in-charge.
Sandwich Kitchen Platform : 'Providing & Fixing Sandwich type Kitchen Platform of Min. 750mm wide using Top
18mm thick granite of approved shade and sample and bottom 25mm thick single side Polished kota stone with
25 mm thick screed of cement mortar 1:3 With granite Facia Patti. and vertical End granite supports. The stone
38 shall be fixed by chassing in to the wall surface and supported vertically with 25mm thick sandwich kota stone SQM 3,159.00 360.00
support to complete job as directed by Architect/Engineer -in-charge. It is inclusive of all necessary chasses &
civil work, holes and cuts etc. comp. No extra payment shall be made in any case.
Toilet Wash Basin Counters - Providing & Fixing Granite wash basin counter of granite of Min. 600mm wide
using Top 18mm thick granite having drop facia with epoxy adhesive to 25mm tk. marine play wood along the
platform as per typical details given in. ref. drawing of approved shade and sample. It allows for all necessary
39 mirror polish moulding, edge polishing, chamfering, etc. completed. Necessary arrangement of MS SQM 4,418.00 332.00
50mmx50mmx2mm customized bracket fixed to given wall to support granite top shall be part of this item. It is
inclusive of all necessary chasses & civil work, holes and cuts etc. comp. No extra payment shall be made in any
Granite Urinal Partitions : Providing and fixing stone slab with table rubbed, edges rounded and both side
polished, of size 450x900 mm deep and 40 mm thick, fixed in urinal partitions by cutting a chase of appropriate
40 width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 SQM 1,793.00 3.00
cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge
and finished smooth.Granite Stone of approved shade
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade of
concrete M300 pnumatic compressed / vibrated mechanically and as per approved design Confirming to IS
41 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line and level as per SQM 680.10 1,241.00
guidlines of IRC : SP 63-2018 etc. Complete.
Providing and fixing pre-cast concrete kerbstone of gray cement based concrete block 30cm
42 length,30cmheightand15cmthickofM200grade concret as per approved design and including excavationfor fixing RMT 376.43 527.00
inproper lineandlevel,filling the jointwithC:M1:3 (1cement:3fine sand) etc complete.
Providing and laying cushioning layer on R.C.C. Slab consisting of 75mm thick lime, concrete using brick
aggregate of 20mm nominal size mortar compresing of 1-Lime : 2- fine sand)
TOTAL OF FLOORING & PAVING WORK
E PAINTING AND POINTING
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall
44 surface to give an even shade including throughly brushing the surface free from mortar droppings and other SQM 78.44 19,336.00
foreign matter and sand papered smooth.
Finishing wall with water proofing cement paint of on wall surfaces (Two coats) to give an approved brand and
45 manufacture and of required shape even shade after thoroughly brushing the surface to remove all dirt and SQM 63.34 10,500.00
remains of loose powered materials. + for finishing with cement paint on ceiling and sloping roofs.
Applying two coats of putty & two coats of primer of approved brand and manufacture on new wall surface to give
46 an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and SQM 40.19 29,836.00
sand papered smooth.
Exterior Texture Paint : Providing and applying exterior textured paint system on prepared surfaces, comprising
47 1 coat primer, 2 coats textured finish, and 2 coats clear protective top coat, including all materials, labour, surface SQM 164.00 23,385.00
preparation, scaffolding, and complete as per specifications.
White washing with lime on wall surface (onecoats) to give an even shade including thoroughly booming the
surface to remove all dirt, dust; mortar drops and loose scales of lime washand other foreign matter.
Metal surface primer+paint : Applying priming coat over new steel and other metel surface after and including
preparing the surface by throughly cleaning, oil,grease, dirt and other foreign matter and scoured with brushes
fine steel wood, scrapers and sand paper with ready mixed priming paint brushing red lead. Painting two coats
(excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even
49 shade including cleaning the surface an even shade including cleanicn the surface of all dirt, dust and other SQM 121.28 1,120.00
foreign matter. Painting two coats (excluding priming coat) on new steel and other metal surface with enamel
paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleanicn
the surface of all dirt, dust andother foreign matter
TOTAL OF PAINTING AND POINTING WORK
F CEILING & PARTITION WORK
Item no. Item Description Unit Rate Total Qty. Amount
GYPSUM BOARD CEILING : Providing and fixing suspended false ceiling at all heights using a galvanized steel
framework with ceiling drop up to 1000 mm, designed to satisfy L/400 deflection criteria under 200 Pa load. The
ceiling shall comprise single layer 12.5 mm thick tapered edge gypsum board conforming to IS 2095 (Part 1):2023
Type A / EN 520 Type A or equivalent approved standards, consisting of aerated gypsum core encased in and
firmly bonded to paper liners, having required thermal and mechanical properties.
The framework shall be made of galvanized steel sections conforming to relevant standards, manufactured from
CR1 grade steel with minimum yield strength of 300 MPa and appropriate corrosion protection (minimum 120 522.00
GSM or equivalent coating), including perimeter channels fixed along walls/partitions at specified intervals using
approved fasteners suitable for the substrate, ceiling angles suspended from the soffit using cleats and anchors,
intermediate channels, and ceiling sections fixed at required spacing to form a rigid grid.
The gypsum boards shall be fixed to the framework using suitable drywall screws at specified spacing. All joints
shall be treated with approved jointing compound and jointing tape, finished in multiple layers to achieve a
smooth, seamless surface ready to receive paint.
The work shall include making necessary cut-outs and providing framing for light fixtures, diffusers, grills and
other services, complete in all respects as per approved drawings and directions of the Engineer-in-Charge.
The item shall include all materials, labour, scaffolding, tools and tackles, all leads and lifts, complete, but
excluding final painting.
MOISTURE RESISTANT GRID CEILING :Providing and fixing tiled false ceiling in true horizontal level using
600x600 mm grid system with hot-dip galvanized steel sections, comprising main runners (~24x38x0.3 mm) at
1200 mm c/c, cross tees (~24x25x0.3 mm) at 600 mm c/c and secondary tees forming 600x600 mm grid,
supported on GI wall angles (~24x24x0.4 mm) fixed along periphery. The framework shall be suspended from
soffit using cleats, hangers and approved fasteners at specified spacing, ensuring proper alignment and level. All
sections shall be of galvanized steel conforming to relevant standards with minimum 90–120 GSM coating.
The grid shall accommodate 12–12.5 mm thick square edge gypsum/plasterboard tiles of size 595x595 mm
conforming to IS 2095 or equivalent, factory laminated with decorative/facing finish and sealed edges, laid in the
grid to form a uniform ceiling. The system shall include all necessary supports, hangers, fasteners and
accessories, complete in all respects as per drawings and directions of the Engineer-in-Charge.
GYPSUM GRID CEILING : Providing & Fixing of Soft Fibre Acoustical Suspended Ceiling System with Optra
Beveled Tegular Edge Tiles With Armstrong Silhouette 15mm Exposed Grid. The tiles should have Humidity
Resistance (RH) of 95%, NRC 0.9, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class
1 (BS 476 pt - 6 &7) in module size of 600x600x15mm, suitable for Green Building application, with Recycled
content of 66% GW & 74% RW. The tile shall be laid on Armstrong Silhouette profile grid system with 15mm
white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm and a load
carrying capacity of minimum 7.90 Kgs/M2 (as per standard installation layout mentioned below) & pull out
strength of 100Kgs. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to
provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and need to be
52 installed with Suspension system of Armstrong make. SQM
Item no. Item Description Unit Rate Total Qty. Amount
The Tile & Grid system used together should carry a 10 year warranty.ARMSTRONG SUSPENSION SYSTEM
accessories manufactured and supplied by Armstrong World Industries consisting of M6 Anchor Fasteners with
hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413
MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can
also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm
aquiline wire to be used with the main runner).Hanging system up to 1.5 M (for above mentioned item)
Cement Board False Ceiling - Designing, Fabricating, testing, installing and fixing of Heavy-duty GI Sections,
8mm thk. Cement fibre sheet fixed with self-tapping screw, keeping 3-4 mm gaps at every joint. Acrylic Sealant
53 will be applied to all cement board joints. All the joints are treated with 150 mm-wide 160 GSM Fibre Mesh and SQM 2,440.00 78.00
Styrobond DP. Terabond A (Mixing Ration with water 1:5) will be applied to the cement board. Finish TOP Coat -
Exposed Concrfete Finish Decorend will be applied in two layers.
TOTAL OF CEILING AND PARTITION WORK
G WATER PROOFING WORK
RAFT: Supplying and installing waterproofing treatment for Raft/Grade slab by using fully bonded HDPE sheet,
membrane 1.2mm thick before casting of the RCC Raft.
The preapplied, fully bonded HDPE sheet membrane to get bonded to the underneath of the poured concrete
used as base/ raft slab to resist lateral water migration. The fully bonded HDPE sheet membrane shall consist
of a thick HDPE film, a highly aggressive pressure sensitive adhesive and Granuels which bonds integrally to 3,026.00
poured concrete of base slab.
The membrane shall conforms to basement waterproofing protection to grade 3 as defined in BS 8102:2009. The
fully bonded HDPE sheet waterproofing membrane shall have following minimum properties :
1) Resist hydrostatic pressure of - 60 +/- 6 m head of water (as per ASTM D5385)
2) Peel Adhesion to concrete- Minimum 1.5 N/mm
3) Puncture Resistance – 800 +/- 100 N
4) Tensile strength -21 +/- 3 N/mm2
54 5) Engloation :400% SQM
6) Bare HDPE Thickness > 0.8 mm
7) Joint Strength at overlap - 15 +/- 2 N/mm
The fully bonded HDPE sheet membrane shall be installed with heat welded method by accurately positioning
sheets by overlapping them for 100 mm. The membrane shall be laid over the concrete blinding having smooth
dried surface including necessary removal of release liner while applying, necessary overlaps between the
membranes and fixing overlaps by Double sided adhesive tape firm rolling onto the surface to get a tight seal,
etc. Hot applied materials or protective screed shall NOT be permitted. All systems to be installed as per
manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed
by Engineer in-charge.
This membrane shall be terminated Horizontally and fixed using EVA at the junctions/ pheriphary of the basement
wall & Raft as per Manufacturers recommendation, including all materials & labour, etc, all complete.
Item no. Item Description Unit Rate Total Qty. Amount
Retaining Wall Waterproofing :
Surface preparation: The substrate must be free of loose aggregate, slush, mud, sharp protrusions and stagnated
water. Ground water level needs to be kept under the PCC level, continues dewatering to be done till completion
of concreting. The surface of retaining wall should be dry (moisture content <5%) before application of
primer.Construction Joint treatment: All the construction joints in retaining wall should be opened in a V groove
manner of size 10mm X 10mm using a grinder or suitable tool & should be sealed with Polymer Modified Mortar
prepared with ReArm Bond SBR 45 or equivalent @5 liter per 50 kg bag of cement.
Filling of tie rod holes: The tie rod holes shoukd be filled with Polymer modified mortar prepared using ReArm
Bond SBR 45 or equivalent @5 liter per 50 kg bag of
Preparation of chamfer or vatta at wall & raft junction: The junction between RCC raft & retaining wall should be
treated by preparation of vatta of size min. 50mm X 50mm with Polymer Modified Mortar prepared ReArm Bond
SBR 45 or equivalent @5 liter per 50 kg bag of cement.
Application of primer: Bituen based Primer should be applied on treated, dry concrete surface at coverage of 4 to
6 SQM per liter using a brush or roller. Primer should be allowed to dry for minimum 2 hrs. The SBS membrane
should be fixed within 24 hours after application of primer.
SBS Membrane: Supplying and applying waterproofing of RCC Retaining wall using High performance, self
adhesive membrane with cross laminated HDPE film AquaArm SBS 3000 X or equivalent,conforming to BS
8102 & IS 16471 as per the specifications listed below - Puncture Resistance: 300 N (as per ASTM E 154) and
Hydrostatic Head Resistance: not less than 70 m head (ASTM D 5385), Tensile Strength - 4.0/3.5 N/mm² (ASTM
D 412) ,Elongation of > 230 % (ASTM D 412), Low Temperature Flexibility up to: -15°C. The SBS membrane
should be fixed on the primed concrete surface by removing the release film with maintaining overlap of 75 mm at
the sides & 100 mm at the end sections.'
Protection of membrane: The SBS Membrane should be protected by means of 6-8 mm thick dimple boards
against any physical damage before commencement of backfilling.
Termination of Membrane on retaining wall: The SBS membrane should be secured with a Metal strip on
retaining wall (300 mm above the ground level) used in conjunction with polyurethane sealant between the
56 membrane and Metal Strip. The termination bar / Metal strip must be installed directly into the wall width and RMT 291.00 272.00
mechanically fixed at c/c using appropriate fasteners. A bead of Sealant is applied along the top edge of the
termination bar.
TERRACE WATERPROOFING : Surface Preparation: Providing and laying water proofing treatment to
horizontal and vertical surfaces of concrete, including cleaning the surface with wire brush, treating all
surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving
preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing.
Item no. Item Description Unit Rate Total Qty. Amount
Injection Grouting (If required): Providing Chemical injection treatment in the form of pressure grouting to the
cold joint by injecting cement slurry mixed with grout admixture ArmGrout Additives @ 250 gms.per bag of
cement, in the required consistency through the pre fixed PVC nozzles in the 10mm dia holes, fixing of PVC
nozzles with quick setting compound ReArm Fix 10S of MYK Arment or equivalent and final cutting the projected
nozzles and sealing off the PVC nozzles after the injection operation is over with quick setting compound , no
shrink rapid setting mortar compound, finishing, curing etc. as per manufacturers specification and as directed.If
any lekages found in pre
ponding then this need to be done.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed
with SBR polymer at dosage of 5Ltr per 50kg cement.
Application of Primer: Apply Epoxy based primer over well prepared surface at 200-400 gm per SQMr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single
component polyurethane based waterproofing system . It has to be applied @1.95 kg/SQMr to achieve a
thickness of 1.2 mm in two coats.The membrane will have the following technical parameters: Tensile Strength :
2 N/mm² ,. Elongation at break : 400% , Adhesion To concrete: >1.5 N/mm²
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed:Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average
thickness of 100 mm mixed with Integral Waterproofing admixture at the dosage of 125 ml/bag of cement over
waterproofing layer to a minimum thickness of 75 mm as per site requirement including control joints of 4M X 4M
size and filling the panels with polyurethane sealant.
Item no. Item Description Unit Rate Total Qty. Amount
WET AREA (Kitcen, Toilets, Wash Area) : Surface Preparation: Providing and laying water proofing treatment
to horizontal and vertical surfaces of concrete, including cleaning the surface with wire brush, treating all
surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving
preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing.
Injection Grouting (If required): Providing Chemical injection treatment in the form of pressure grouting to the
cold joint by injecting cement slurry mixed with grout admixture @ 250 gms.per bag of cement, in the required
consistency through the pre fixed PVC nozzles in the 10mm dia holes, fixing of PVC nozzles with quick setting
compound and final cutting the projected nozzles and sealing off the PVC nozzles after the injection operation is
over with quick setting compound , no shrink rapid setting mortar compound, finishing, curing etc. as per
manufacturers specification and as directed. If any lekages found in preponding then this need to be done.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed
with SBR polymer at dosage of 5Ltr per 50kg cement.
Waterproofing Coating-Providing and application of a two component, cementitious acrylic polymer based
high performance water proofing coating. It offers seamless coating applied@ 2 Kg /SQM for 2 coats @
mm DFT .Technical Data: Inter coat application time, Hrs 2-3, Tensile strength (ASTM D 412) >2 N/mm²
Elongation at break (ASTM D 412)
>175%, Adhesion strength (ASTM D 4541) >1.2 N/mm², Crack bridging (ASTM C 836) pass up to 2 mm.
Toilet Sunk Filling : (not applicable for toilets with underslung plumbing) :
Providing and filling sunken area with Light Weight Block bat (40-60 mm) with cement mortar mixed in ratio 1:3:6
(1 cement : 3 sand : 6 brick bats) including mixing of water proofing compound 4 % by weight of cement to sunk
portions of toilets to the entire satisfaction of the PM. Toilet / Sunk portion shall be tested by ponding water for
WATER RETAINING STRUCTURES (UGT & OHT) : Surface Preparation: Providing and laying water proofing
treatment to horizontal and vertical surfaces of concrete, including cleaning the surface with wire brush, treating
all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving
preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing.
Injection Grouting (If required): Providing Chemical injection treatment in the form of pressure grouting to the
cold joint by injecting cement slurry mixed with grout admixture @ 250 gms.per bag of cement, in the required
consistency through the pre fixed PVC nozzles in the 10mm dia holes, fixing of PVC nozzles with quick setting
compound and final cutting the projected nozzles and sealing off the PVC nozzles after the injection operation is
over with quick setting compound , no shrink rapid setting mortar compound, finishing, curing etc. as per
manufacturers specification and as directed.If any lekages found in pre ponding then this need to be done.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed
with SBR polymer at dosage of 5Ltr per 50kg cement.
Item no. Item Description Unit Rate Total Qty. Amount
Protective Plaster: providing and laying avg. 15 mm thick, CM 1:4 plaster admixed with Integral Waterproofing
Compound @ 150 ml / bag of cement at Vertical Walls. Food Grade epoxy coating- Application of food grade
epoxy coating in Inner side of tank: providing and applying CFTRI Certified epoxy coating applied @
kg/m2 in two coats. It will give 400 microns thickness. Pot life: 30 Minutes at 25°C ,20 Minutes at 30°C,Mixing
Ratio, by Weight: 100(Base):38(Hardener), Touch dry: 4 Hours at 30ºC, Re coatable: 12 -18 Hours at 30ºC, Open
to foot traffic: 24 Hours at 30ºC, Final cure: 7 Days at 30ºC, Adhesive bond strength to concrete, (ASTM D 4541):
>1.5 MPa (concrete failure)
WATERPROOFING FOR PODIUM WITH HARDSCAPE : Surface Treatment: Providing and laying water
proofing treatment of terrace including cleaning the surface with wire brush, treating all surface cracks,
construction joints and honeycombs by grouting with specialised non shrink grout and preparation of surface in all
aspects to receive the waterproofing.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed
with SBR polymer ReArm Bond SBR 45 of MYK Arment or equivalent at dosage of 5Ltr per 50kg cement.
Application of primer: Providing and applying Epoxy based primer FloArm Primer PUDC of MYK Arment or
equivalent over well prepared surface at 200-400 gm per Sq.Mtr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single
component polyurethane based waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has
60 to be applied @1.95 kg/sqmtr to achieve a thickness of 1.2 mm in two coats.The membrane will have the SQM 2,440.00 2,489.00
following technical parameters: Tensile Strength : 2 N/mm2 ,. Elongation at break : 400% , Adhesion To concrete:
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed:Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average
thickness of 100 mm mixed with Integral Waterproofing admixture AquaArm Prufe IWP 10 of MYK Arment or
equivalent at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm as
per site requirement(Civil Contractor Scope) including control joints of 4M X 4M size and filling the panels with
polyurethane sealant.
WATERPROOFING FOR PODIUM WITH SOFTSCAPE : Surface Treatment: Providing and laying water proofing
treatment of podium including cleaning the surface with wire brush, treating all surface cracks, construction joints
and honeycombs by grouting with specialised non shrink grout and preparation of surface in all aspects to receive
the waterproofing.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed
with SBR polymer ReArm Bond SBR 45 of MYK Arment or equivalent at dosage of 5Ltr per 50kg cement.
Application of primer: Providing and applying Epoxy based primer FloArm Primer PUDC of MYK Arment or
equivalent over well prepared surface at 200-400 gm per Sq.Mtr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single
component polyurethane based waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has
to be applied @1.95 kg/sqmtr to achieve a thickness of 1.2 mm in two coats.The membrane will have the
following technical parameters: Tensile Strength : 2 N/mm2 ,. Elongation at break : 400% , Adhesion To concrete:
Item no. Item Description Unit Rate Total Qty. Amount
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed:Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average
thickness of 100 mm mixed with Integral Waterproofing admixture AquaArm Prufe IWP 10 of MYK Arment or
equivalent at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm as
per site requirement including control joints of 4M X 4M size and filling the panels with polyurethane sealant.
Dimple Board for Protection of membrane before Backfilling:
Providing and applying Extruded Polystyrene Protection Board of approved make and around 8 mm thick and
shall be laid down to the membrane and then soil filling can be done as per manufacturer's recommendation.
TOTAL OF WATERPROOFING WORK
H DOOR AND WINDOW WORK
FLUSH DOOR (SINGLE / DOUBLE LEAF) WITHOUT HARDWARE WITHOUT LOUVERS : Providing and fixing
35 mm thick pre-laminated (1mm) hinged door made out of 150mm x 70mm cp-sag indian teak wood outer frame
with holdfast and shutters made of 35 mm thick facory fabricated flush door including concealed lipping
(35mmx6mm-matt malamine polished to exposed surface) to receive hinges. colour and shade for laminates shall
62 be as architect. All necessaty carpentery and civil work to fix in true line & level, plumb at all level shall be part of SQM 5,233.00 1,270.00
contractor and commissioned as directed by EIC. Hardware shall be paid extra under relavent item. It is inclusive
of matt melamine polish (1 coat sealer + minimum 2 coat matt mellamine polish) with sanding, rubbing, etc.
For single / double leaf shutter without hardwares without louvers
FLUSH DOOR (SINGLE LEAF) WITHOUT HARDWARE WITH LOUVERS : Providing and fixing 35 mm thick pre-
laminated (1mm) hinged door made out of 150mm x 70mm cp-sag inidan teak wood outer frame with holdfast
and shutters made of 35 mm thick facory fabricated flush door including concealed lipping (35mmx6mm-matt
malamine polished to exposed surface) to receive hinges. colour and shade for laminates shall be as architect. All
63 necessaty carpentery and civil work to fix in true line & level, plumb at all level shall be part of contractor and SQM 5,644.00 11.00
commissioned as directed by EIC. Hardware shall be paid extra under relavent item. It is inclusive of matt
melamine polish (1 coat sealer + minimum 2 coat matt mellamine polish) with sanding, rubbing, etc. complete
Do as above for single leaf with louvers without hardwares
HARDWARE FOR DOORS :
HINGE FOR ALL FLUSH DOORS : dormakaba 3043F, 5 Knuckle, 2 Ball bearing butt hinges size 4" x 3" x 3mm,
Material: SS 304, Finish: Satin Stainless Steel (SSS). Suitable for Wooden door weight up to 120kgs, Grade
64 Template Drilled. Approved to EN 1935, Fire-rated, Square Corners, Durability - 200,000 Cycles, Corrosion Nos. 273.00 1,992.00
Resistance - Very High
MORTICE SASH LOCK FOR REGULAR DOORS : dormakaba Mortice sash lock 271a with 55mm backset,
20mm square forend with 72 mm centers and prepared for euro profile cylinder including strike plate in satin
65 stainless steel as per EN 12209, Durability - 200,000 Cycles, Load on Latch Bolt - 50N , Door mass - 200 kg, Nos. 1,599.00 196.00
Corrosive resistance - Very High ( - 20 C to +80 C)
MORTICE SASH LOCK FOR TOI. DOORS : dormakaba Mortice WC lock 275a with 55mm backset, 20mm
square forend with 78 mm centers and prepared for 8mm bathroom follower including strike plate in satin
66 stainless steel as per EN 12209, Durability - 200,000 Cycles, Load on Latch Bolt - 50N , Door mass - 200 kg, Nos. 1,598.00 261.00
Corrosive resistance - Very High ( - 20 C to +80 C)
Item no. Item Description Unit Rate Total Qty. Amount
MORTICE DEAD LOCK : dormakaba Mortice dead lock 278a with 55mm backset, 20mm square forend,
prepared for euro profile cylinder including strike plate in satin stainless steel as per EN 12209, Durability -
67 200,000 Cycles, Load on Latch Bolt - 50N , Door mass - 200 kg, Corrosive resistance - Very High ( - 20 C to +80 Nos. 1,581.00 15.00
LOCK PROFILE FOR DEAD LOCK : dormakaba Mortice dead lock 278a with 55mm backset, 20mm square
forend, prepared for euro profile cylinder including strike plate in satin stainless steel as per EN 12209, Durability
68 - 200,000 Cycles, Load on Latch Bolt - 50N , Door mass - 200 kg, Corrosive resistance - Very High ( - 20 C to +80 Nos. 459.00 15.00
EURO PROFILE CYLINDER - BSK (Both Side Key) : dormakaba DEC 6 Plus 60, 6 pin Euro profile cylinder with
69 inline brass keys. Master keyed system included as per client requirement. Nos. 1,997.00 183.00
External & Internal key operation. Length: 60mm
EURO PROFILE CYLINDER - KT (Key + Thumbturn) : dormakaba DEC 6 Plus 60T, 6 pin Euro profile cylinder
70 with inline brass keys. Master keyed system included as per client requirement. Nos. 2,168.00 112.00
External key & Internal thumb turn operation. Length: 60mm
EURO PROFILE CYLINDER - CT (Coin + Thumbturn) for Toilets : dormakaba 3016, 6 pin Euro profile knob
71 cylinder with internal thumb turn and external coin operation standard length 60mm in satin nickle plated finish. Nos. 1,476.00 177.00
NMK.Durability: 100,000 Cycles
LEVER HANDLE (PAIR): dormakaba Pure Lever handle 8906 lever with round roses, escutcheons prepared for
Euro profile cylinder and spindle 114 in satin stainless steel. Complete set including the fixing accessories for
72 50mm thick door. Material:SS 304. Approved to EN 1906 , Durability - 200,000 Cycles, Corrosion Resistance - Nos. 2,639.00 452.00
LEVER HANDLE WITH INDICATOR (PAIR): dormakaba Pure 8906 Lever Handle with 6501 Roses,7122 WC
Indicator, 8mm Spindle with Fixing Screws for door thickness 35-55mm, SS 304, Finish : Satin
74 TOWER BOLT : dormakaba 3200-2 Surface Mounted Tower bolt of Length 6" in Satin chrome finish Nos. 474.00 87.00
75 PEEP HOLE : 180° brass/SS, dormakaba equivalent Nos. 748.00 84.00
DOOR CLOSER : dormakaba rack and pinion door closer TS 68 with selectable closing force, size EN 2, 3 and
76 , std. arm adjustable closing speed in two independent ranges. Non-handed. Approved to EN 1154. Durability - Nos. 3,308.00 8.00
500,000 Cycles ,Corrosive resistance - Moderate, Finish:Silver
PULL HANDLE (PAIR) : dormakaba pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood
77 and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on Nos. 1,922.00 15.00
the outer surface.CTC - 300mm, 22mm dia, Material - SS304
DEAD BOLT FOR SHAFT FLUSH DOORS : dormakaba Mortice shaft dead bolt with key with BS 57mm and
25mm Sq forend with escutheions in SSS.
OVAL PULL HANDLE FOR SHAFT FLUSH DOORS : dormakaba Recessed Oval Flush Pull Handle 1207, SSS
HARDWARE FOR ADA TOILET DOOR :
ADA TOILET DOOR - HINGES : dormakaba 3043F NRP, 5 Knuckle, 2 Ball bearing butt hinges size 4" x 3" x
3mm with Non-Removable Pin, Material: SS 304, Finish: Satin Stainless Steel (SSS). Suitable for Wooden door
80 weight up to 120kgs, Grade 13, Template Drilled. Approved to EN 1935, Fire-rated, Square Corners, Durability - Nos. 401.00 4.00
200,000 Cycles, Corrosion Resistance - Very High
Item no. Item Description Unit Rate Total Qty. Amount
ADA TOILET DOOR - DOOR CLOSER : dormakaba TS 92 B barrier free access designed cam action door
closer complying to BS 8300 & ADM opening force of below 30N between 0º and 30º degrees and below 22.5N
between 30º and 60º degrees. Complies to CEN 15894 Guidelines of 40% reduced opening force & minimum
65% door closer efficiency. Door closer with G-N slide channel arm for pull side fixing, adjustable closing speed in
two independent ranges. closing force infinitely variable between size EN 1 and EN 4. Non-handed.
Approved to EN 1154 and CERTIFIRE, CE Marked. Durability - 500,000 Cycles, Corrosive Resistance - High.
ADA TOILET DOOR - LOCK : dormakaba Mortice WC lock 375a with 55mm backset, 20mm square forend with
78 mm centers and prepared for 8mm bathroom follower including strike plate in satin stainless steel as per EN
12209, Durability - 200,000 Cycles, Load on Latch Bolt - 120N , Door mass - 200 kg, Corrosive resistance - Very
High ( - 20 C to +80 C)
ADA TOILET - LEVER WITH INDICATOR : dormakaba Pure Lever handle 8100 lever with round roses,
WC Indicator and spindle 114 in satin stainless steel. Complete set with fixing accessories for 50mm thick door.
Approved to EN 1906, Durability - 200,000 Cycles, Corrosion Resistance - Very High
ADA TOILET DOOR - GRAB BAR : dormakaba GBDI D-600 Grab Bar of Length 610mm, 25mm Diameter in
Satin stainless Steel Finish.
METAL DOORS - FIRE RATED (120 Mins)
METAL FIRE DOORS (120 Minutes) with 30 min insulation As per IS3614:
Supply and fixing of Hollow metal fire rated doors as per IS 3614:2021 for stability and integrity with 30minutes
insulation. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door
shall have doors tested at CBRI /NABL Approved Labs for maximum rating of 2hrs tested . Individual Test
certificates should also be available for glass used in vision lites confirming the required fire ratings /panels being
a part of the fire door assembly. Doors should be finished in Thermosetting Powder Coating desired RAL Shades.
Manufacturer test certificate shall cover doors both single & double leaf doors and Hardware's should pass
European certificate "CE" of conformity / UL with required fire ratings. Any deviation in specification and sheet
thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of
door and the hourly rating is mandatory. Approved manufacturer Navair International or equivalent subject to
architect’s approval. And should be ISO Certified company.
Item no. Item Description Unit Rate Total Qty. Amount
Door frame shall be Single rebate profile of section 100 x 57 mm made out of 1.60mm thick galvanised steel
sheet with a factory pre-punched groove so as to accomodate Fire & smoke seal size 10x4mm . Frames should
be butt jointed and field assembled with bolting system for proper strength .Frames should be provided with back
plate for anchor fasteners (payable extra ) for installation on a finished plastered wall opening.
Door leaf shall be minimum 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be
manufactured from 1.2mm minimum thick galvanised steel sheet. The internal construction of the door should be
rigid reinforcement pads for receiving appropriate hardware. The infill material shall be Rockwool treated with
Viper FRS 881 LH. All doors shall be factory prepared for receiving appropriate hardware and provided with
necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending
radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive
leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beading
and screws from inside.
All doors and frames shall be finished with Powder coating in desired Shades. Once frame installed should be
filled with PUF as recomended by the manufacturer or engineer.
HARDWARE FOR METAL DOORS
SS Ball Bearing Hinges of size 100 x 75x 3mm complete with SS Screws of Becker fs make ( 4 Nos per panel )
87 Door closer overhead STD arm Becker fs make Nos. 2,553.00 45.00
88 Fire glass 6MM Thick 200x300mm Vision Glass from Saint Gobain Nos. 2,128.00 46.00
89 Mortise dead lock with both side key cylinder Becker fs make Nos. 2,502.00 89.00
90 SS Pull handle 300 mm long back to back D type Becker fs make Nos. 1,909.00 89.00
91 Fire seal 10x4mm & smoke seal RMT 299.00 381.00
92 Hilti fasteners 10X 80mm Nos. 64.00 603.00
93 Concealed flush bolt 600mm long for double door Becker fs make Nos. 1,403.00 67.00
Frameless "U" Channel glazing (INTERNAL FIXED GLAZING)
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover of Frameless glazing system with
Aluminium "U" Channel custom designed to with stand the design wind pressure confirming to IS -875 part III.
(The system must pass the proof test at 2 times design wind pressure without any failure).
The system shall be support the glass at bottom and wind resistance at top by means of continuous U-channel at
the finished floor level and vertically butt glazed with non staining sealant joint between glass to glass. The
weather sealant of approved make, baker rod, SS 304 grade fasteners & hard setting blocks of EPDM, all in
complete required to perform as per specification and drawing in conjunction with BOQ. Complete system shall
94 be warranted for minimum 10 yrs against design & workmanship defects. SQM 4,370.00 121.00
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from
approved extruder. All the visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder
coating of 60 - 80 micron.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design, engineering & Approval from architect & consultant.
Quote rate for complete system as mentioned above under (B) U-Channel Design in line with Tender drawings for
Ground Floor and First Floor Retail Area, Providing & Fixing Façade 12mm Clear FT Glass.
Item no. Item Description Unit Rate Total Qty. Amount
Frameless Swing Doors_ (Patch Fitting Doors)
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover Single & Double leaf double swing
patch fitting door made out 12mm thick fully tempered (FT) glass with Dorma make stainless steel patch fittings
for external facade application (PT Series ). Complete with 38mm dia SS handle 1000mm long , PT series patch
fittings, US 10 Door lock at bottom of each shutter and BTS 80, 90 deg with EN 1-4 spring capacity floor spring.
Floor spring covers shall be SS satin finish. as per Architect's approved shop drawings.
Door glass of 12 mm thk clear float fully tempered with holes and notches as per patch fitting requirement. Edges
Machine ground mirror polished. The door glass shall have silicon gasket at bottom to act as weather seal.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete system for Frame Less Patch Fitted Door as mentioned above under (C)
1 - Double Leaf Swing Door:- (Size:- 1500mm x 2100mm) with 12mm Thk. Clear FT Glass. Location:- First floor
Internal Portion.
2 - Single Leaf Swing Door:- (Size:- 1000mm x 2100mm) with 12mm Thk. Clear FT Glass. Location:- First floor
Internal Portion.
Aluminium Louvers ( "Y" Type Louvers) System_
Vantilation Lover system - BUILDING FAÇADE AT SHAFTS LOCATION
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover of Aluminium " Y " shape Louvers
System custom designed to with stand the design wind pressure confirming to IS -875 part III.
Aluminium Louvers shall be made out of 60mm x 36mm x 1.5mm thk. of " Y " shape louvers system spaced at
equivalent distance support to Aluminium frame. Louvers profile shall be fixed on the 3mm thick Al flat to form a
frame. The louver frame is supported on the aluminium box frame with necessary fasteners in SS 316 in line with
97 The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from SQM 8,349.00 359.00
approved extruder. The structural profiles shall have minimum 2 mm wall thickness. All the internal & External
visible surfaces shall have Super Durable Powder coating finish of 60-80 micron thickness as per Approved
shade by Architect. The non visible aluminium surfaces shall have mill Finish.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete Aluminium "Y" Type Louvers system as mentioned above under (F)
Aluminium "Y" Type Louvers system_Vantilation Louver System, Location:- Staff Qtrs exterior face shafts
Sliding Window - 4 track : Providing and fixing extruded aluminum window having extruded aluminum Colour
Powder Coated section frame main outer size 127mm x 38.10mm x 1.35mm ,@ Wt.1.384 Kg/mt,horizontal Four
track member size 122.20mm x 31.75mm x 1.10mm @ Wt. 1.205 Kg/mt,vertical member of size 122.20mm x
31.75mm x 1.50mm ,@ Wt. 1.398 Kg/mt with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm
98 @ wt.of 0.456Kg/mt,vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,@ with 5 mm thick SQM 2,119.14 11.00
transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent
silicon sealant glass fixing to frame as per details etc complete for window.
Item no. Item Description Unit Rate Total Qty. Amount
Sliding Window - 3 track : Providing and fixing window having extruded aluminum Colour Powder Coated
section frame main outer size 95mm x 24mm x 1.17mm @ wt.of 0.738 Kg/mt, horizontal Three track member size
92mm x 31.75mm x 1.30mm @ Wt.1.07 Kg/mt, vertical member of size 92mm x 31.75mm x 1.50mm ,@ Wt.
99 Kg/mt with sliding shutters of horizontal member size 40 mmx18mm x1.29mm @ wt.of 0.456 Kg/mt, vertical SQM 1,576.11 815.00
member of size 40mm x 18mm x 1.29 mm @ wt.of 0.456Kg/mt with 5 mm thick transparent bronze colour tinted
float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame
as per details etc
Sliding Window - 2 track : Providing and fixing window having extruded aluminum Colour Powder Coated
section frame main outer size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track member size
1.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical member of size 61.85 mm x 31.75mm x 1.30 mm @
100 wt.of 0.0.659 Kg/mt with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, SQM 1,688.78 206.00
vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt with 5 mm thick transparent bronze colour
tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to
frame as per details etc complete for window
VENTILATION : Design, Fabrication, Installation, Protection, Cleaning and Handover of Alum. Glass Louver
windows with exhaust Fan fixing Provision in Toilet areas with hardware's and accessories.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from
approved extruder. All the internal visible surfaces shall have high Durability (AkzoNobel) / Super durable (Jotun)
Powder coating of 60 - 80 micron confirming to AAMA 26043. The non visible aluminium surfaces shall have
minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete Glass Louvers system as mentioned above under :
Ventilation Windows (V1) Bottom Glass Louvers With Top Fix :- SQM 3,422.00 30.00
Top Fix:- 6mm Thk. Frit Glass SQM 3,422.00 30.00
Glass Louvers:- 5mm Thk. Frit Glass @30mm C/C SQM 3,422.00 30.00
ALUMINIUM FIXED WINDOW / Top/side HUNG OPENABLE (OUT) :
Design, Fabrication,Supply,All Material & Site Testing, Protection, Handover of Alum. Fix / Top/Side Hung
102 openable windows system custom designed to with stand the design wind pressure confirming to IS -875 part III.
The system shall have two barrier gasket system for weather sealing. Provision for drainage of uncontrolled water
entering to 1st barrier gasket.
Top/Side hung openable window system shall be including malti-point locking (Min.two) with Handle, projected
type hinges with restrictor arm of approved make, Microwave cured EPDM gaskets. window shutter profile to
accommodate the 6mm SGU HS glass, weather sealants, SS 316 grade screws and fasteners of approved
make, all in complete required to perform as per specification and drawing in conjunction with BOQ.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from
approved extruder. All the internal visible surfaces shall have high Durability (AkzoNobel) / Super durable (Jotun)
Powder coating of 60 - 80 micron confirming to AAMA 26043. The non visible aluminium surfaces shall have
minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
Item no. Item Description Unit Rate Total Qty. Amount
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete Aluminium Windows system as mentioned above under (F) With 6mm Thk. HS
Glass in line with tender drawing.
Providing and fixing a Top/Side Hung Openable vent With 6mm Thk. HS Glass . SQM 6,182.00 83.00
Providing and fixing a Fix Windows With 6mm Thk. HS Glass. SQM 5,089.00 37.00
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together
through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft
103 with bracket plates, guide channels and arragements for inside and outside locking with push-pull operation SQM 3,468.72 30.00
including the cost of hood cover and spring etc. complete. (B) Shutters having width 3.5 M. and above
104 Providing and fixing 27.5 cm. long wire spring grade No.2 of approved make for rolling shutters. EACH 630.91 4.00
Providing and fixing Hood cover for rolling shutters (B) Shutters having width 3.5 meters and above
TOTAL OF DOORS AND WINDOWS
J MISCELLENEOUS
Pre construction Anti termite Treatment : Providing and injecting pre-constructional anti-termite treatment as
per IS:6313 (Part-II) to the RCC members in immediate contact with soil upto a min depth of 500 mm measured
from made up ground level by treating all four sides at the rate of 7 Lit/Sqm of an emulsion in water of 0.5 %
Chloripyrofos 20 EC or equivalent, treating the top surface of plinth filling and the external peripheri of the building
by drilling the holes up to 75 mm deep at 150 mm c/c distance bothways using 12 mm dia ms rod on the surface
to facilitate saturation of the soil with the chemical emulsion at the rate of 5 Lit/Sqm of surface area of an emulsion
in water of 0.5 % Chloripyrofos 20 EC or equivalent. The contractor shall furnish 10 years guarantee for termite
free structure. (Plan area at ground floor level shall be measured for payment.)Notes:1) Allow for Min. of 10 years
gaurantee as described under detailed specifications. 2) Only single time Plinth area shall be measured for
payment, deducting open to sky shafts,verandah etc. for all kinds of buildings i.e. building having basements or no
Toilet Cubicals : Providing and fixing toilet cubical systems of approved make and manufactured in standard
dimensions of 600mm ± 10mm width door size with 12mm thick solid Compact Laminate panels made of KRAFT
paper impregnated with Phenolic resins under high pressure and temperature, including doors, pilasters &
intermediate panels, which should be resistant to heat, bacteria, water, chemical, scratch and impact. Finished
product should be as per approved texture, shade & drawing, detailing and developed according to IS-2046 and 19.00
BS-476/97 standards. The toilet cubicle setup shall include necessary hardware fittings, made out of stainless
steel (Grade-304), as per manufacturer’s specifications and approved by Engineer-in-charge.
Hardware fittings should consist of (1) Stainless steel Adjustable foot/ pedestal of SS 316 grade to give 150mm
clearance from bottom and of weight not less than 600grams (2) Stainless steel U-channels of 20 gauge and 12 x
20mm size (3) Stainless steel Top rail pipe (OD:24mm of 18 gauge) with corner connectors (4) Stainless Steel
Head Rail Tubular Holder (5) Stainless steel Gravity hinges (3 nos.) not less than 75mm length and weight not
less than 210 grams of weight not less than 200 grams. (6) Stainless steel Coat hook with nylon door stopper (7)
Stainless steel Door knob (8) Stainless steel Baby latch (9) Wall bracket SS 304 (10) Corner Connector (11)
Rubber noise deafening tape (12) Stainless steel 304 Screws and PVC wall plugs
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing 6mm thick frameless mirror of approve make in any shape and sizes as per drawing. Mirror
shall be fixed on 12mm thick marine plywood backing. Marine plywood shall be fixed to wall with approved SS
108 fastener. All edges of glass shall be sharp grinded, cut corner and polished. Glass shall be fixed with approved SQM 5,897.00 119.00
adhesive/ 3M tape etc. complete at all floors/ all levels/ all heights as directed by Engineer In Charge. Installed
area of mirror shall be considered for payment without wastage.
Structural steel work ( Confirming to IS 4923-1997) riveted, bolted or welded in builtup for all type sections, in
framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all
complete as per the structural designs and directions of Engineer in charge.
Providing, fabricating, assembling, hoisting/ erecting and fixing for structural steel work in position at all heights/
all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections,
Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bright Bars, Angles, MS
Sheet, Girder, Beam, cattle trap. deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per
drawing. all confirming to latest relevant IS codes for the work of steel structures like gratings over drain channel,
I beams, staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap,
windows, pipe rack, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame
work etc. including straightening, cutting, bending, bolting and welding the members all as per structural drawings
and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc.
complete in the situations described hereinafter and comprising of : i) Profile Cutting of components to required
length/ width and shape/ profile;
ii) Smooth grinding/ machining of edges/ faces/ all welding joints; iii) Necessary welding (electric arc welding) for
required weld lengths and sizes. (non structural elements) iv) Machine drilling of holes for joining/ anchoring
(Standard measurements will be paid for as actual cut length used at site).
Note: The contractor shall be submit fabrication drawings based on construction drawings (that may be issued
during construction period with at least one mock up approved by architecture ) for approval by the Architect/
Engineer. The fabrication work shall start only after approval of the fabrication drawings submited by contractor.
Any change required in the fabrication drawings shall be carried out at No extra cost. Fabrication shall be in a
perfect architectural workmanship manner and as provided in section V & VI of IS 800 & IS 7215. Welding shall
be carried out by qualified welders/ fabricators.It should also include the cost of necessary scaffolding/ staging,
zinc coated nut-bolt as required for safety, structural stability of all works at site.
Extra on STRUCTURAL STEEL item - for all kinds of sleeves in hydraulic structure Hot dip Galvanised with
110 minimum 65microne thick (only difference shall be paid instead of 2 coat zinc chromate yellow oxide and 2 coat of KG 92.00 505.00
Providing and fixing G.I. chain link fencing of required width in mesh size 50x50 mm including strengthening with
2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
111 Made of G.I. wire of dia 4 mm SQM 3,393.00 25.00
Item no. Item Description Unit Rate Total Qty. Amount
Providing and wet drilling accurate and clean holes of 25‑400 mm range without vibration through Hilti diamond
drilling machine DD200 having 1:1 & 1:3 gearing ratio for wide range of reinforcements in concrete, control panel
112 indicator to display proper pressure application, capable of drilling at angle from 0o‑ 45o and do overhead
application. Before coring rebar loaction to be identifed with Hilti PS 250 (ferroscanner) tool or equvivalent.
TOTAL OF MISCELLENEOUS
K FURNITURE WORK
Providing And Supply High Back Rev. Chair Upholstered with Leatherette Seat Made Up Of 12mm +/- 1mm Thick
Hot Pressed Mr. Grad Plywood and Back in Two Pieces - 12mm Rear Back And 6mm Inner Back. Moulden
Polyurethane Foam Used in Making Seat with Molded Density 45+/- 2 Kg/M ³. Back Is Made Out Of 32 Density
Block Foam Covered With 14mm Thick 32 Density Foam Sheet (Block Foam). Spine Bracket Made Of M.S Plate
8mm Thickness Connecting Back with Mechanism. Armrest Top Is Soft Touch Polyurethane Molded Of 250 To
300 Density Insert Stainless Steel Pipe Having Unique " Y "Shape. The Mechanism of the Chair Have Following
Features: 360⁰ Revolving Type 3.5Mm Thk Crca Seat Plate With 4Mm Thk Crca Channel Plate Synchro
Mechanism, Tilt Tension Adjustable, Single Position Locking, Plastic Component Inside the Mechanism of Grade -
Mi 3530 And Epoxy Powder Coated 70 Microns with Tested 1.2 Lacs Cycles as Per Bifma Standard. The Chair
113 Provided with Pneumatic Height Adjustment Which Have Have Stroke Of 100mm +/- 5mm.The Five Leg Base Is Nos 16,168.00 3.00
Made Up Of 38Mm Dia X 1.2Mm Thick Tubular With 3.15mm Thick Centre Hub Crc Fabricated Chrome Finish. It
Have Be Fitted With 50mm Dia Twin Wheel Castor . The Size of The Base Have Be - 660 +/- 1mm Pitch-Centre-
Diameter. Load Test As Per Bifma Compliance. The Twin Wheel Castors Made Of Nylon Injection Molded In
Black Color. Overall Dimensions Of Chair Have Be, Width Of Chair - 640mm, Depth Of Chair 640mm As
Measured From Base Below. Height Of Back From Ground - Min 1175 To Max 1275mm. Seat Height -Min
480mm To Max 580mm. Dimensions Tolerance / Variations Have Be Within +/- 10mm.
Item no. Item Description Unit Rate Total Qty. Amount
Providing And Supply Med. Back Rev. Chair Upholstered With Leatherette Seat Made Up Of 12mm +/- 1mm
Thick Hot Pressed Mr Grad Plywood And Back In Two Pieces - 12mm Rear Back And 6mm Inner Back. Moulded
Polyurethane Foam Used In Making Seat With Moulded Density 45+/- 2 Kg/M ³. Back Is Made Out Of 32 Density
Block Foam Covered With 14mm Thick 32 Density Foam Sheet (Block Foam).Spine Bracket Made Of M.S Plate
8mm Thickness Connecting Back With Mechanism. Armrest Top Is Soft Touch Polyurethane Moulded Of 250 To
300 Density Insert In Stainless Steel Pipe Having Unique " Y "Shape. The Mechanism Of The Chair Have
Following Features: 360⁰ Revolving Type 3.5Mm Thk Crca Seat Plate With 4Mm Thk Crca Channel Plate
Synchro Mechanism, Tilt Tension Adjustable, Single Position Locking , Plastic Component Inside The Mechanism
Of Grade - Mi 3530 And Epoxy Powder Coated 70 Microns With Tested 1.2 Lacs Cycles As Per Bifma Standard
114 The Chair Provided With Pneumatic Height Adjustment Which Have Have Stroke Of 100mm +/- 5mm.The Five Nos 19,716.00 26.00
Leg Base Is Made Up Of 38Mm Dia X 1.2Mm Thick Tubular With 3.15mm Thick Centre Hub Crc Fabricated
Chrome Finish. It Have Be Fitted With 50mm Dia Twin Wheel Castor . The Size Of The Base Have Be - 660 +/-
1mm Pitch-Centre-Diameter. Load Test As Per Bifma Compliance.The Twin Wheel Castors Have Be Made Of
Nylon Injection Moulded In Black Colour.Overall Dimensions Of Chair Have Be, Width Of Chair - 630mm, Depth
Of Chair 630mm As Measured From Base Below. Height Of Back From Ground - Min 950 To Max 1050mm.
Seat Height -Min 470mm To Max 570mm. Dimensions Tolerance / Variations Have Be Within +/- 10mm.
Providing and supply Seat and back in single piece with integrated arms like bucket shape, nylon moulded of
to 500 density fix inner and outer snap fit arrangement in back with mesh fabric inside on equal interval of
rectangular slots design. The mechanism of the chair have have following features : 360⁰ revolving type, 2.5mm
thk CRCA powder coated center tilt Mechanism, Tilt tension adjustment, locking in single position, Plastic
115 component inside the mechanism of Grade - MI 3530 and Epoxy Powder coated 70 Microns with tested 1.2 lacs Nos 11,184.00 20.00
cycles as per BIFMA Standard The chair have be provided with pneumatic height adjustment which have have
stroke of 100 +/- 5 mm. The Base have be made of injection moulded nylon. It have be fitted with 5 nos. twin
wheel castor - 50 mm diameter. The size of the base be 660 +/- 1 mm pitch-centre-diameter. The twin wheel
castors have be made of Nylon injection moulded in black colour.
Providing And Supply Med. Back Rev. Chair Upholstered With Leatherette Seat Made Up Of 12mm +/- 1mm
Thick Hot Pressed Mr Grad Plywood And Back In Two Pieces - 12mm Rear Back And 6mm Inner Back. Moulded
Polyurethane Foam Used In Making Seat With Moulded Density 45+/- 2 Kg/M ³. Back Is Made Out Of 32 Density
Block Foam Covered With 14mm Thick 32 Density Foam Sheet (Block Foam). Armrest Top Is Soft Touch
116 Polyurethane Moulded Of 250 To 300 Density Insert In Chrome Finish Pipe Having Unique "Bird Beak"Shape.. Nos 14,829.00 50.00
Pipe structure of MS CRCA finish 16 gauge round pipe having a diameter of 25 mm with epoxy powder coated.
Overall Dimensions Of Chair Have Be, Width Of Chair - 630mm, Depth Of Chair 630mm As Measured From
Base Below. Height Of Back From Ground - Min 950 To Max 1050mm. Seat Height -Min 470mm To Max 570mm.
Dimensions Tolerance / Variations Have Be Within +/- 10mm.
Item no. Item Description Unit Rate Total Qty. Amount
Type: 2 Seater Sofa
Size (approx. Over all dimension): 1500mm(W) x 800mm(D) x 780mm (H) Top: Upholstery with Latherite Finish
all visible surfaces
Specifications:Providing and supply Sofa sturcture made from 18mm MR Grade Mr grad plywood supported with
Maranti Solid wood, back side and curved part Covered with 3mm flexi ply, sofa arm made from 12mm thick MR
Grade Mr grad plywood supported with maranti solid wood. Elastic Belt, 75mm board & 2.25 mm thick elastic
webbing stapling in seat frame at 100 mm centre to centre distance, belt fastern in X and Y axies of seat, elastic
117 belt elongation 45% tensile strength 350 kg. Foam 100 mm X 40 density Premium Quality foam covered with Nos 70,414.00 6.00
25mm X 32 density super soft Premium Quality Foam for soft touch filling in seat. 50 mm X 40 density Premium
Quality foam covered with 25mm X 32 density super soft Premium Quality foam for soft touch filling in back.
Stiching Stiching work done with well known german brand (Aman / Gutermann) Thread. Nylone & Polyster thread
used as per application. Leg made from Stainless steel 316 Grade. all material selection will be as per architect's
selection, etc all complete with respect to necessary hardware and finishes
CENTER TABLE SIZE:-1100 x 600 & 450mm height
Providing fixing and arranging Center Table Providing and supply Top 20 mm thick made of PLY with 1 mm thick
laminate finish with 2 mm thick PVC edge bidding matching with same laminate finish.
118 STRUCTURAL SUPPORT SYSTEM:- shall be constructed using 40 x 40 mm matt finish S.S. Metal frame legs as Nos 22,367.00 3.00
per image. Entire table to be finished with all necessary hardware and selection of material as per architect.
SIDE TABLE SIZE:-500 x 500 & 450mm height
Providing fixing and arranging Center Table Providing and supply Top 20 mm thick made of PLY with 1 mm thick
laminate finish with 2 mm thick PVC edge bidding matching with same laminate finish.
119 STRUCTURAL SUPPORT SYSTEM:- shall be constructed using 40 x 40 mm matt finish S.S. Metal frame legs as Nos 11,598.00 3.00
per image. Entire table to be finished with all necessary hardware and selection of material as per architect.
"C" shaped table overall dimension 2250x1800x2700mm & 750mm height with 36 MM thick nail curvica post
forming edges made of 17mm OSR MDF with curvica laminate finish both long edges with ends having matching
2mm pvc edge band / beading, bottom surface to be finished with balancer white. Provision to be given for snake
/ vertebrae from floor to wire manager for pop up box with switches and sockets as per detail design and
drawings. Fixed Drawer Unit Outer body 17mm thick MDF with curvica Laminate Finish. three drawers with
bullnose front with lock and necessary hardware. Side Table : Size as per drawings, Top and leg 36 MM thick nail
curvica post forming edges made of 17mm OSR MDF with curvica laminate finish both long edges with ends
having matching 2mm pvc edge band / beading. shutter 17mm thick OSR MDF with curvica Laminate Finish
120 bullnose curvica laminate finish with lock and necessary hardware. Back Unit size as per drawing Top and leg 36 Nos 1,36,685.00 3.00
MM thick nail curvica post forming edges made of 17mm OSR MDF with curvica laminate finish both long edges
with ends having matching 2mm pvc edge band / beading. shutter 17mm thick OSR MDF with curvica Laminate
Finish bullnose curvica laminate finish with lock and necessary hardware. Entire table to be finished with all
necessary hardware. There will be provision of footrest of size 750 x 400 x 150mm & storage top side and back
unit top having a ledge of 150mm x 100mm boxing as shown in image included in it. All hardware should be
concealed & not visible. All handles should be concealed with SS finish.
Item no. Item Description Unit Rate Total Qty. Amount
Product : Collaborate Loop Leg Design
Dimensions : 1200mmL x 600mmD x 750mmHT Table top + 350mmHT Screen
Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges
Support: End Legs: MS powder coated Collaborate Loop legs
Intermediate Legs: MS podwer coated 60X40mm legs and supporting MS cross beams (40X20mm)
Main Screen : 900mmL x 350mmHT - 18mm Thick Al. Framed Fabric Magnetic Screen with in-built Accessories
Rail mounted on table top with Powder coated Studs
Return Screen : 8mm Sandwich Glass Screen of 350mmHt x 525mmL mounted on table top with metal powder
121 coated studs Nos 10,638.00 12.00
Modesty : 12/18mm thick PLT modesty leg to leg for privacy of 450mmHt with 225mm Floor Clearance Gap
Wire Management
250mm Ht Racway with 65mm Dia Wire Manager Grommet
Vertical Raceway with built in separator for power and data of size 250H X 70mm thick with provision to mount
swicthes and sockets on laminate facia with Vertical Wire Entry cover for wire uptake from floor to raceway with
65mm Dia Wire Manager Grommet.
TABLE SIZE Linear shaped :-1200 x 600 & 750mm height
Providing and supply Top 36 mm thick made of PLY with 1 mm thick laminate finish with 2 mm thick PVC edge
bidding matching with same laminate finish. Apron 18mm thick PLY board with 1mm thick laminate finish with
122 mm thick PVC edge matching with laminate bidding, under structure made of 50x50mmx1.6mm thick MS square Nos 24,852.00 7.00
pipe with powder coated (50-60 micron) finish. WIRE MANAGEMENT MS-Powder coated wire tray with pop up
box switch plate and vertical cable raisers / PVC wire guard are considered for wire management.
TABLE SIZE Linear shaped :-1350 x 600 & 750mm height
Providing and supply Top 36 mm thick made of PLY with 1 mm thick laminate finish with 2 mm thick PVC edge
bidding matching with same laminate finish. Apron 18mm thick PLY board with 1mm thick laminate finish with
123 mm thick PVC edge matching with laminate bidding, under structure made of 50x50mmx1.6mm thick MS square Nos 24,852.00 1.00
pipe with powder coated (50-60 micron) finish. WIRE MANAGEMENT MS-Powder coated wire tray with pop up
box switch plate and vertical cable raisers / PVC wire guard are considered for wire management.
Item no. Item Description Unit Rate Total Qty. Amount
Providing and Fixing coustmised conferece table of 3000x1200x750 STRUCTURE:- Set of table top, modesty and
gable end designed in handshake pattern to build the closed module, open module of Video conferencing pattern
V-shaped configuration of the conference table with infinite seating arrangement depending upon space available
to set the conference table. TABLE TOP:- 30mm thick table top made up of 18mm thick ply wood with 1 mm thick
laminate board with 12mm thick thin PVC foil wrapped decorative profile made up of ply fixed along all the edges
from the bottom side which provide decorative waterfall edge profile to top with twin colour look the decorative
trim to be connected at the angle of 45 degrees with each other. Single seater small top of size 675mm width and
600mm depth. Two-seater big top of size 1350mm width and 600mm depth can shape open type and O shape
close type configuration. Two-seater end top of perfect semicircle shape of the radius of 600mm usable for the
close module with the lowest space of 1200mm in front to front seating. LEG:- 25mm thick Leg or Gable End
made up of 25mm thick pre-laminated particle board with MS leveller bracket to give floating look. MODESTY:- 2.00
Modesty Panel made up of 18mm thick ply wood with 1 mm thick laminate providing stability to structure and allow
sufficient leg privacy to the user. "D" headed decorative aluminium profile fixed on it. WIRE MANAGEMENT:-
Provision for wire passing throughout the structure without mixing data and power connections. The wires can be
124 pulled inside the table from floor and placed in the boxes build below openable shutter. The access point for data Nos.
and power can be mount on the main top as well as the openable top. Access flap is box structure made up of
aluminium extrusion with necessay switches and sockets and connectivity to different equipments. etc all
complete with necessary hardware and complete as directed by engineer incharge. all visible and non visible
surfaces to be claded with 1 mm thick laminate as per detail design drawings.
WIRE MANAGEMENT:- Provision for wire passing throughout the structure without mixing data and power
connections. The wires can be pulled inside the table from floor and placed in the boxes build below openable
shutter. The access point for data and power can be mount on the main top as well as the openable top. Access
flap is box structure made up of aluminium extrusion with necessay switches and sockets and connectivity to
different equipments. etc all complete with necessary hardware and complete as directed by engineer incharge.
all visible and non visible surfaces to be claded with 1 mm thick laminate as per detail design drawings.
Providing and fixing lockable cupboard of size 1200x450x2100 mm with 4 shelves two parts. Material – 0.7mm
thick (+/-0.07mm) CRCA for shelf; 0.8mm thick (+/-0.08mm) high yield strength CRCA for doors & back; 0.9mm
thick (+/-0.08mm) CRCA for all other components. It should have 2 way locking mechanism with shooting bolt &
125 rase s per req.handle or without handle.. It should have height wise adjustable shelf With uniformly distributed Nos. 32,308.00 1.00
load capacity per each full shelf 40kg maximum. Finish – Epoxy Powder Coated to the thickness of 50 microns (+/-
10).etc complete with all necessary hardware. all handles to be consealed. no hinges to be visibal. shade of
powercoating will be as per architect's choice.
Providing and fixing File Storage.1500x450x750mm Top made of 25 mm thick PLY bothside covered 1 mm thick
laminate finish ,sides 18 mm thick PLY bothside covered 1 mm thick laminate finish.9mm thk PLY bothside coberd
with laminate finish.Skirting and Front Shutters/drawer fascia made of 18 mm thick ply bothside covered 1 mm
126 thick laminate finish with necessary hinges and lock. Shutter hanging on Hinges, Lock and handle are consealted Nos. 39,349.00 3.00
or profile or groove handle less etc.All edge 2mm thick Pvc beading matching with laminate will be provided.etc all
necessary hardware included and complete as per image and detail design and drawings. all laminate shaed are
to be as per architects's selection.
Item no. Item Description Unit Rate Total Qty. Amount
Supply, fabrication, and installation of modular kitchen cabinets using economical materials, with carcass made of
commercial plywood or pre-laminated particle board finished with 0.8 mm laminate or pre-laminated surfaces on
both sides and basic edge banding to exposed edges, shutters made of commercial plywood or MDF finished with
0.8 mm laminate on the outer face and white or balancing laminate on the inner face, and provision of drawers
127 using basic telescopic channels (non-soft close) along with stainless steel (SS) wire trolleys in place of tandem RMT 20,710.00 516.00
systems, including basic cutlery tray and essential storage accessories; all visible surfaces to be finished in
matching laminate shades selected and approved by the Architect/Engineer-in-Charge, and the work to include
complete installation of the kitchen unit with all necessary basic hardware such as hinges, handles, channels,
fittings, and accessories as per drawings and site requirements
Providing and fixing in position PVC Frosting Glass film of approved make (of any pattern, shade and type) on
glass partitions and doors for internal use. Film shall be pasted on glass without any appearing any air bubble.
128 The rates shall be for all shapes and all heights with necessary scaffolding complete as per the Architectural SQM 1,243.00 20.00
drawings and manufacturer's specification & instructions as directed by the Architect and Engineer-in-charge. Film
shall be with 10 years warranty.
Providing and fixing roller blinds with composition 100% Polyester . Fabric woven and semi opaque / coated
translucent fabric & Complete Blackout. The fabric shall be enclosed in the suitably created pocket along with
tube i.e Palmate. Fabric Warranty 3Year. Weight 190 GSM, Width 280 cm, Thickness 0.48mm, Light fastness is
to 5 grade. Mechanism made in UK with ball chain mechanism & with 5 years mechanism warranty. The Roller
tube extruded by non-rusting Aluminium alloy with 1.25 mm thickness. Available in 32, 38, &45 mm diameters for
small and big blinds respectively. Mechanism is designed with support beam to keep it straight and have a pocket
for holding the fabrics in position. The mounting brackets shall be universal and capable of mounting inside/
outside/ ceiling / wall with the clutch on either the right or left end of the tube. Mechanism to be operated with
control unit made of high strength ABS plastic. Mechanism shall be operating with the use of a ball chain, made
up of unbreakable polyethylene plastic, 1.50mm polyester cord with 4.50 mm balls. The blind shall be able to stop
at any desired position with the help of stop lock. The bottom channel of Roller Blind shall be matching shade with
fabric and made of non-rusting aluminium powder coated with 1.50 mm thickness. The fabric shall be enclosed in
the suitably created pocket along with tube.
TOTAL OF FURNITURE
Parking Suspended Sign : Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per
European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet)
with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty
under normal working conditions.Sign is double sided 50 mm depth profile with media accomodation depth of
130 mm media of ACP acrylic upto 5 mm thickness can be pasted directly on frames or attched on frame with help of Nos. 33,350.00 9.00
dual lock tape.Sign can be edge lite with help of edge lite led modules ,led of LUCOLED make EL31 , fitted and
installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-
Item no. Item Description Unit Rate Total Qty. Amount
Door Nameplate Sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per
European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet)
with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty
under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded
131 endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted Nos. 1,988.00 101.00
,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb
and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Floor directory sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per
European standards EN755-2-2008 tensile strength 190 MPa made from virgin aluminium homogeneous billet)
with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty
under normal working conditions.Sign is single sided with aluminium side tracks and common click clips for panel
132 fitting. a.Sign is including all plastic injection moulded clips black in shade which are slided in side tracks ,media SQM 2,070.00 5.00
can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and
level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Toilet Door Sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with
Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty
under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded
133 endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted Nos. 746.00 8.00
,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb
and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Closet Door sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with
Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty
under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded
134 endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted Nos. 746.00 44.00
,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb
and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Lift Number sign - Providing sign of Cosign make Modular Aluminium extrusions (Alloy 6060 as per European
standards EN755-2-2008 tensile strength 190 MPa Made from virgin homogeneous aluminium billet) with
premium grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty under
135 normal working conditions. Profile to form frame with overall depth of 10 mm with media of thickness upto 3mm. 2 Nos. 1,380.00 30.00
mm thick acrylic/ACP . I-sign Fix profile of Cosign make with M.S zinc coated corners with grub screws. Installed
at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Item no. Item Description Unit Rate Total Qty. Amount
Emergency Exit sign - Providing ready sign & fixing at location a Cosign make emergency exit sign- illuminated,
surface mount (wall or ceiling) Dual sided made up of plastic material , battery backup of 3 hours (180 mins)
.Battery life of 300 cycles of charge & discharge Li- ion battery 3.7 Volt, 100 mA, Charge time of 24 hours. Input
voltage 220-240 Volt A.C, 50/60 Hz. Viewing distance 30 meter, degree of protection IP20 (rating for protection
against solid object upto 12 mm) white light colour full back (white colour) LED illumination with green white
coloured graphic inserted on both sides on 0.4 mm PC (sizes, texts, symbols or graphics as per standard safety
norms & regulations) graphic options of -left ,right, up staircase down staircase. Test facilty button self test plus
auto self test, opreration in maintained and non maintained mode (power saver mode).Sign with 12 months
warranty for electric circuit & 6 months warranty for battery. Sign provided with dual mounting arrangement of
mounting on wall & celing both ( with flat rigid support/base).Sign is including all connection wires (upto 1 mtr) &
high tensile strength zinc coated self tapering screws (4 nos with screw wall plastic packing), installed at site in
plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
BUILDING SIGNAGE - Aluminium Channel Letters -
Specifications:
Supply and installation of 1mm thick and 4" depth Aluminium Channel letters with proper backside fabrication with
3mm acp female and 3mm acrylic having led of GOQ 3 Genius 2835 having 5 years warranty and power supply
of Union/E-power with 5 years warranty. Wiring to be done by using 1.5mm wire of Finolex brand.
137 5 Years warranty Power dissipation ‑ Nos. 11,500.00 21.00
View angle ‑ 175 Luminous flux ‑ 90lm
Colour cct ‑ Pure White, 10000k Cool
white Dimensions (mm) 66*15*10.5._
TOTAL OF SIGNAGES
Design, supply, delivery and installation of FRP Surface Heavy Duty Recessed Manhole Cover with Frame
(450mm x 450mm clear opening) for sewer manholes and storm water catchpits, including proper seating in
138 RCC top slab, alignment, grouting, finishing and all complete as per drawings and specifications, including all Nos. 8,867.00 10.00
materials, labour, tools, transportation, and fixing at site.
Design, supply, delivery and installation of FRP Surface Heavy Duty Recessed Manhole Cover with Frame
(600mm x 600mm clear opening) for sewer manholes and storm water catchpits, including proper seating in
139 RCC top slab, alignment, grouting, finishing and all complete as per drawings and specifications, including all Nos. 17,118.00 22.00
materials, labour, tools, transportation, and fixing at site.
Design, supply, delivery and installation of FRP Water Gully cover with Frame Heavy Duty (600mm x 600mm
clear opening) for valve chambers, including proper seating in RCC top slab, alignment, grouting, finishing and
140 all complete as per drawings and specifications, including all materials, labour, tools, transportation, and fixing at Nos. 13,082.00 2.00
Providing, supplying and fixing FRP moulded grating of 38mm thickness, panel size 310mm x 1220mm,
141 including cutting to required sizes, proper placement over supporting frame, fixing with suitable clamps/fasteners, Nos. 1,271.00 41.00
alignment, and all necessary accessories, complete as per drawings and specifications.
TOTAL OF MEPF WORK
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward,
East Zone, Ahmedabad city under Building Project Department.
SUBESTIMATE - 03 : HVAC WORK
S. NO. ITEM DESCRIPTION AMOUNT
A SUB TOTAL - DX SYSTEM
B SUB TOTAL - AIR DISTRIBUTION NETWORK
C SUB TOTAL - CIVIL SUPPORT STRUCTURE
D SUB TOTAL -DUCT INSULATION
E SUB TOTAL - VENTILATION FANS
Total of HVAC Works
F MAINTENANCE & OPERATION FOR HVAC
TOTAL OF MAINTENANCE & OPERATION FOR HVAC
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under Building Project Department.
BOQ FOR SUBESTIMATE - 03 : HVAC WORK
Item Description
Item no. Unit Rate Total Qty. Amount
MECHANICAL WORKS
Providing and erecting Inverter based approved make split air-conditioning unit consisting of
condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with
accessories etc. duly connected separately erected evaporating unit and blower motor with its
1.0 accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for (
cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with
necessary core cutting.
(2)For ISEER Range (KWH/KWH)(4.0 to 4.49)
a) for 0.8 to 1.0 ton capacity- Premium cat.
b) 1.5 ton capacity- Premium cat.
Providing and erecting Inverter based approved make Cassette type split air-conditioning unit
consisting of condensing unit with fan motor, hermetically sealed scroll/rotary compressor with
2.0 accessories etc. duly connected separately erected evaporating unit and blower motor with its
accessories by Eco friendly Green gas charging & Internal copper wiring & Remote control ( 3 star and
above of current year) with necessary core cutting.
(A) for 1.5 ton capacity
(B) for 2 ton capacity
(C) for 3 ton capacity
(D) for 4 ton capacity
Supplying & installing MS standard type stand mounting for outdoor unit of Split A.C. upto 4 TR
capacity erected with necessary hardware materials as directed.
Supplying and erecting insulated pair of soft copper tubing open or concealed including power and
control cable,necessary PVC drain pipes for Split AC machine up to 4 TR capacity
Supplying and installing MS angle , powder coated / Painted standard type of wall/floor stand mount for
outdoor unit of split AC of following capacity, erected with necessary hardware materials as directed.
5.0 (A) 25mm*25mm*3mm thick M.S angle suitable for upto 2 TR. Capacity of ac machine Each 1,305.00 -
Item Description
Item no. Unit Rate Total Qty. Amount
6.0 DRAIN PIPING :
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.
A SUB TOTAL - DX SYSTEM
B AIR DISTRIBUTION NETWORK
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers,
6.0 vanes, hangers, supports etc. as per approved drawings and specifications of following sheet
complete as required.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,
7.0 hangers, supports etc. as per approved drawings and specifications of following sheet thickness
complete as required.
Item Description
Item no. Unit Rate Total Qty. Amount
Supply and installation of MS Welded rectangular ducts, complete with required flanges , necessary
supports of pregalvanised steel of 275gsm and 4.8 strength class threaded rods (as directed) and ETA
8.0 Approved anchor bolts, supply air collars, vanes, splitters dampers and as per specification for Air
Conditioned Areas - For Kitchen Exhaust
( Support Shall be provided as free supply to the contractors )
8.1 18 G MS Ducting Sqm. 2,450.00 2.00
Supply, installation, testing & commissioning of thermal insulated flexible duct
of following sizes duly supported at regular interval as per site requirement etc.
9.0 complete as required as per Mtr 696.00 10.00
specifications.(A) 200 mm dia.
SUPPLY INSTALLATION TESTING AND COMMSSIONING OF DIFFUSERS/ GRILLES AS PER
FOLLOWING SCHEDULE
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume
10.1 control dampers complete as per specifications and size & shape as per site requirement and approved SQM. 10,328.00 0.50
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without
10.2 volume control dampers complete as per specifications and size & shape as per site requirement and SQM. 7,003.00 1.00
approved design.
Supplying, fixing testing commissioning of supply air diffuser of powder coated aluminium with
10.3 aluminium volume control dampers with anti smudge ring & removable core and size & shape as per SQM. 13,553.00 0.50
site requirement and approved design.
Supplying, fixing testing commissioning of Return air diffuser of powder coated aluminium without
10.4 volume control dampers with anti smudge ring & removable core and size & shape as per site SQM. 9,301.00 0.50
requirement and approved design..
Supply fixing and testing , commisioning of Aluminium Powder Coated Slot Diffuser complete with
plenum box and volume control damper. Color , size & shape as per site requirement and approved
11.0 design.. Neccessory ancilery item for fixing cost should be included.
Contractor need to revalidate the diffuser selection before preparing shop drawing.
12.0 Rain Protection Fresh Air Grill for Façade installation. Sqm 7,500.00 20.00
13.0 SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF DUCT DAMPERS
Supply, installation, testing and commissioning of GI volume control duct damper complete with
neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Item Description
Item no. Unit Rate Total Qty. Amount
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and
return air path as and where required of required sizes i/c control wiring,the damper shall be motorized
and spring return so as to close the damper in the event of power failure automatically and open the
13.2 same in case of power being restored. The spring return action shall be inbuilt mechanism and SQM 11,905.00 0.50
not externally mounted. The damper shall also be closed in the event of fire signal complete
as required and as per specifications.
(A) Fire damper
13.3 (B) Actuator Each. 11,153.00 0.50
14.0 Double Layer Weather Proof Machine Canvass Connection ( FAN ) Set 3,500.00 2.00
B SUB TOTAL - AIR DISTRIBUTION NETWORK
C CIVIL SUPPORT STRUCTURE
15.0 Vibration Absorbant spring supports for Fans ( 4 to 8 Support for each FAN ) Set 1,500.00 2.00
16.0 Engineered Rubber Support Pad for Split AC Out Foor Unit Set 1,800.00 7.00
MS Welded Structure (Supply and erection of M.S. angle stand with synthetic epoxy paint for all
18.0 Core Cut up to 150mm Dia Lot 1,350.00 4.00
C SUB TOTAL - CIVIL SUPPORT STRUCTURE
D DUCT INSULATION
19.0 DUCT THERMAL INSULATION
Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastomeric
nitrile rubber of class 'O' applied by suitable adhesive, as per specifications and as required
complete in all respect.
19.2 13 mm thick SQM 610.00 - -
20.0 DUCT ACCOUTIC INSULATION
Providing and fixing acoustic Insulation of open cell nitrile rubber sheet having density of 180-220
kg/m3 and recommanded thickness of 15 mm. Absorption coefficient value of Insulation material shall
be 0.90 for the 2000 Hz frequency band in accordance to IS:8225/ISO:354/ASTM 423C. Material shall
have fire class 1 as per BS 476 , part 7. Material Shall be EPA approved and Anti-Fungal & Anti-
Bacterial in accordance with ASTM G21 & ASTM E 2180 respectively. It shall be fixed inside of the duct
with the help of adhesive as per the specifications given.FSK tape shall be applied at joints.
21.0 UNDER DECK INSULATION :
Item Description
Item no. Unit Rate Total Qty. Amount
Supply & Fixing Under deck Insulation with 50 mm thick Fire Retardant Extruded Polystyrene having
density of 32 Kg / M3 and thermal resistance of 1.78 M2 K / W
D SUB TOTAL -DUCT INSULATION
E VENTILATION FAN
22.0 CABINET TYPE INLINE CENTRIFUGAL EXHAUST AIR FAN
Supply, Installation, testing & Commissioning of Cabinet type Centrifugal Fans / Inline Fan for Exhaust
Air System complete with SISW Forward Curved blower, fan assembly shall be AMCA certified (AMCA
certification requird for Air Performance & Sound) & totally enclosed, fan-cooled, provided with class F
insulation, and of approved make.,
Fan shall be provided with TEFC Sq.cage, direct driven F' Class induction motor with minimum IP-55
Motor shall be suitable for 220 ± 5% volts, Single phase, 50 cycles electric supply- I OR 415+/-10% V,
50 hz, 3 phase AC. The motor (Eff1 Class-Motor must be VFD Compatible )
Max. noise level shall be 56 dBA at 1.5 meter in hemispherical reverberant room condition.
The complete fan assembly shall be CE Certified in accordance with EN-12101-3:2015 (Vendor shall
submit the certifications for below listed fans)
The Fan units shall be designed as per the criteria mentioned in the specifications and selected so as
to operate in the best efficiency zone; the units shall be statically and dynamically balanced.
Necessary starter shall be in scope of HVAC Contract. Power cable will be available up to starter panel.
The controller will be BMS compatible with all required open protocol and requried licence softares.
23.0 FAN FILTER UNIT
Item Description
Item no. Unit Rate Total Qty. Amount
SITC of Cabinet (Square) Type Inline Centrifugal Fresh Air Fan AMCA Certified (For Air and Sound
Performance) suitable for installing in any position in vertical or horizontal ducts. The casing shall be
single skin, internally acoustically lined and constructed of galvanised steel. The inline fan shall be with
Farword curve up to 1500 CFM & above shall be backward curve centrifugal impeller fitted with
maintenance free external rotor motor, flexible connections at the discharge & inlet. The motor shall be
suitable for 220 / 415±10% volt single/three phase 50 Hz AC supply. 3 phase fans quoted price shall
be inclusive of DOL starter panel with cabling between starter panel and fan. The fan shall have low
sound level exceeding not more than 65 DBA at 3 meter distance.
The fan shall have easily washable 20 micron fresh air filter. The Fan units shall be designed as per the
criteria mentioned in the specifications and selected so as to operate in the best efficiency zone; the
units shall be statically and dynamically balanced. Necessary starter / Panel / Power Cable shall be in
the scope of HVAC Contractor. Power cable will be provided up to starter panel.
24.0 WALL MOUNTED PROPELLER EXHAUST FAN WITH GRAVITY LOUVERS
Supply, Installation, testing & Commissioning of Propeller fan for wall or panel mounting suitable for
supply or exhaust use having casing, protection guard and impeller. Impeller shall be made with
galvanized steel. Entire assembly shall be black enamel painted to avoid the rust. The fan should have
sickle blade impellers with external rotor motor, fan assembly shall be AMCA certified (AMCA
certification requird for Air Performance & Sound) & totally enclosed, fan-cooled, provided with class F
insulation, and of approved make.,
Fan shall be provided with TEFC Sq.cage, direct driven B' Class induction motor with minimum IP-54
Motor shall be suitable for 230 ± 5% volts, Single phase, 50 cycles electric supply- I. The motor (Eff1
Class-Motor must be VFD Compatible )
Max. noise level shall be 60 dBA at 3 meter in hemispherical reverberant room condition.
The complete fan assembly shall be CE Certified in accordance with EN-12101-3 (Vendor shall submit
the certifications for below listed fans)
The Fan units shall be designed as per the criteria mentioned in the specifications and selected so as
to operate in the best efficiency zone; the units shall be statically and dynamically balanced.
Necessary starter shall be in scope of HVAC Contract. Power cable will be available up to starter panel.
Item Description
Item no. Unit Rate Total Qty. Amount
Cassettte type exhaust fan
26.0 Lift pressurization System
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance)
ceiling hung / floor mounted AXIAL flow fans of following capacity with GSS casing/ standard M.S.
construction and aluminium alloy impellers with high efficiency aero-foil sections, blades. The impeller
shall be directly driven by TEFC induction motor with high efficiency class IE2 . Motors shall be suitable
for 3 Phase, 50 Hz, 415V ± 10 %. Motors to be of class 'H' insulation for Supply/Fresh Air Fans and
class 'H' insulation/ 300° C for 2 hrs for smoke or normal Exhaust Fans. The Exhaust air fans-motor
assembly should be CE Listed as per EN-12101-3: 2015.. Motor make shall be same as mentioned on
the fire certificate. Fan total efficiency should not be less than 70%. Entire fan model & AMCA Seal
shall appear in technical submittal of fan. The Axial fans shall have sound level not more than 75 dB(A)
at three meter distance at both ends when measured in closed room conditions. Static pressure
calculation of Fans shall be checked by Vendor/Contractor prior to supply of Fans as per site condition.
If there is any discrepancy against the BOQ, the Vendor/Contractor has to take approval from Client &
Consultant, and nothing extra shall be paid.
Necessary starter shall be in scope of HVAC Contract. Power cable will be available up to starter panel.
The starter should be capable to run automatically in case of fire.
26.1 9000 CFM 18 mm WC ESP ( Liftwell Pres. System ) Set 85,000.00 4.00
E SUB TOTAL - VENTILATION FANS
TOTAL HVAC WORKS
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under Building Project Department.
BOQ FOR SUBESTIMATE - 03 : HVAC WORK
HVAC WORK - AMC CHARGES
Item no. Item Description Unit Rate Total Qty. Amount
ANNUAL MAINTENANCE CONTRACT
(Note : From Each RA Bill, 5% retaination money to be deduct during O&M Period)
Annual Operation Contract of HVAC System for DLP + Four Years
Annual Operation Contract charges for Five years for entire HVAC system installed at the site including shiftwise
1.0 operation with one skilled operator throughout the working hours per shift for two shift. In all respect with periodical
regualr filter cleaning of all Indoor and Outdoor units
1.1 Annual Operation Charges only During Guarentee/Defect Liability period. Months 4,20,000.00 12.00
1.2 Annual Operation Charges only After Guarentee/Defect Liability period for First Year. Months 4,50,000.00 12.00
1.3 Annual Operation Charges only After Guarentee/Defect Liability period for Second Year. Months 4,80,000.00 12.00
1.4 Annual Operation Charges only After Guarentee/Defect Liability period for Third Year. Months 5,15,000.00 12.00
1.5 Annual Operation Charges only After Guarentee/Defect Liability period for Fourth Year. Months 5,52,552.08 12.00
Sub Total - OPERATION AND ROUTINE MAINTANACE
Comprehensive AMC for SITC of High Side units and Ventilation System
It includes all preventive maintanance , break down maintanance with all spares - repair or replacement of the
defactive part or parts , this includes all cosumable if any applicable.
2.1 1st year ( From the date of Completion of DLP ) Months 84,824.38 12.00
2.2 2nd year ( From the date of Completion of DLP ) Months 84,824.38 12.00
2.3 3rd year ( From the date of Completion of DLP ) Months 84,824.38 12.00
2.4 4th year ( From the date of Completion of DLP ) Months 84,824.38 12.00
Sub Total - Comprehensive Maintenance
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone,
Ahmedabad city under Building Project Department.
SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
ITEM DESCRIPTION AMOUNT
A Electrical Works
2a SERVO STABILIZER
3 JUNCTION BOXES
4 DISTRIBUTION BOARD
5 LT CABLES & CABLE TERMINATION
7 INTERNAL WIRING
8 INDOOR LIGHT FIXURE
11 SAFETY ITEMS
12 EXTERNAL LIGHT FIXTURE AND POLE
13 DWC PIPE AND CHAMBER
15 SERVICE WORK
16 RACEWAY/TRUNKING & JUNCTION BOX
Total of Electrical Works
17 FIRE DETECTION & ALARM SYSTEM
18 PUBLIC ADDRESS SYSTEM
19 VOICE COMMUNICATION SYSTEM
Total of ELV Works
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone,
Ahmedabad city under Building Project Department.
SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
ITEM DESCRIPTION AMOUNT
C Maintenance & Operation for Electrical & ELV Works
20 MAINTENANCE & OPERATION FOR ELECTRICAL & ELV WORK
E Comprehensive Maintenance for Lift Works
22 COMPREHENSIVE MAINTENANCE FOR LIFT WORK
F CCTV & Networking System Works
24 NETWORKING SYSTEM
Total of CCTV & Networking System Works
Tender Assumption List.
Quntity in this estimate are based on conceptual layouts and information received from various stackholders. It may
very as per detial design stage.
For Fire station and residential block LT services considered , Substation , meters space marked on drawing basis
of preliminary load. Liason person has to approve same from supply comapany.
All cabling & related assesories upto LT meters are in the scope of supply company, Clients scope start from LT
meters onwards.
4 Any specific equipent or requirement for Fire control center excluded from estimate.
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at T.P 76 F.P. 115-1 in Ramol Ward, East Zone, Ahmedabad city under Building Project Department.
BOQ FOR SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
Item no. Description Unit Rate Total Qty. Amount
1.1 Supplying and erecting, commissioning and testing of Diesel Generating set confirming to IS: Each 19,50,296.00 1.00
4722:1968 & BS:5514 having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply
comprising of a totally enclosed air/water cooled diesel engine with multi-cylinders developing
suitable BHP not less than following capacity at 1500 RPM with 10% overload for one hour in
hours with standard accessories like fly wheel, lubricating oil cooler, "A" class governor, heavy duty
fuel wheel and lubricating oil filter, oil bath air filler, lubricating oil pressure gauge, end exhaust
manifold, standard set of tools with adjustable spanners, screw drivers, cylinder head to cover, joint
cylinder head to exhaust, element lube oil filter, 12 / 24 volts electric starting equipment complete
with standard heavy duty battery, dynamo, cut-outs, ammeter, necessary wiring, pressure gauge,
starter etc and heavy duty Residential type exhaust silencer and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of required length, standard wall/floor
mounted fuel with level indicator and piping and drip proof alternator, self excited, self regulated,
screen protected, with excitation system, capable of delivering the rated system output at 415 volts,
3 phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with voltage
regulation +/- 5% of rated voltage from no load to full load. Both the engine and alternator fitted
on a common fabricated steel base plate with antivibration mounting engine and alternator both
connected to each other by flexible flange coupling and with floor/wall mounted control panel box
comprising of voltmeter ammeter, selector switches, ACB / MCCB / MCB of adequate capacity,
indicator lamps duly wired with HRC fuses. The alternator & control panel shall be connected with
provided suitable capacity armoured cable and complete with Acoustic enclosure (canopy) made
out of 16 SWG CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick
conforming to IS:8183 / PU Foam of 40 Density - at least 40 mm. The resin bonded rockwool
covered from inside the canopy by perforated sheet with 3/4 mm holes, sound level not more than
75 dB at a distance of 1 mtr, as per PVCT norms. Erection, commissioning and satisfactory testing
as per requirement with first filling of fuel, oil, etc. with guarantee / Warrantee of complete system
for Two years. & with obtaining all necessary certificate from Electrical Inspector. The Capacity and
Ratings of DG sets are as below.
(R) Continuous rating of 250 KVA ,BHP not less than 309 BHP
1.2 AMF panel Each 2,20,509.00 1.00
Item no. Description Unit Rate Total Qty. Amount
Providing & erecting approved make AMF control panel suitable for following size of 3 phase,
V., 50 cycles, A.C. diesel generating set complete of scope as detailed below:
1) Power module: A pair of electromechanically interlocked contactors (for mains & generator)
Overload relay for generator contactor Neutral contactor for mains and generator Power socket for
2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items
attempt start facility. Air circuit breakers/MCB/MCCB of suitable rating for auto/manual operation.
Auto/manual switch. Emergency stop push buttons. Manual start push button. frequency meter.
Engine hour meter. Two earthing studs.
3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High
cylinder head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start . Emergency stop battery charger.
The AMF Panel of following capacity
(D) AMF Control Panel for200 KVA/250 KVA 3 phase DG Set
Sub Total 1.....
Item no. Description Unit Rate Total Qty. Amount
Supply, installation, testing and commissioning of 3 phase 415V 4 wire Free Standing Floor
mounted MV panel made out of minimum 14 SWG CRCA sheet after seventank process and
painting with Epoxy powder coating including all switchgear as detailed below. The panel having
PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S.
base channel, hinged door with locking arrangement for equipment/switchgear. The panel shall
consist of suitable rating FP/TPN Aluminium- busbar-as per SLD (at the rating of 0.8ASq.mm)
supported with DMC/ SMC barriers and colour coded with Heat shrinkable sleeves. The Metering
shall be provided as specified.
The panel shall have Short circuit with standing capacity as given in SLD and consist of the
switchgear as mentioned below. The panel shall be mounted on plinth, stand, etc. including all
materials. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. All
the Panels shall have minimum 25% outgoing as per SLD. The earth bus shall be continuoulsy run
without any jointing/welding and its Size should be per SLD. The size of all Panel Mounting Meters
shall be 96X96mm.The Panels shall be mounted on U channels including supply and fixing of the
same. MCBs shall be provided for Control purposes. (All Panels shall be extendable type only).
Price shall be inclusive following:
Shifting of panels from site store to the suitable location. Installation of panel as located in electrical
drawings or as per site conditions, including removing packing etc. Earthing all components, frame
etc. to a common internal earth bar. Connection, testing & commissioning. Electrical contractor
shall carry out the insulation test at site & all the readings shall be submitted in copy to the
consultant or engineer-in-charge. Supply, installation, testing and commissioning all accessories,
supporting structure, hard ware etc to complete the job. Supply, installation, testing and
commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc. The rates
for the distribution boards apart from the Breakers and instruments shall also include the following :
This schedule of Quantities shall be read in conjuction with the technical specification, General &
Special conditions as well as all tender drawings. Supporting rigid steel framework. Cubicle type,
gauge CRCA sheet steel enclosed.
Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location they
serve, providing on each panel its circuit diagram.
Providing cable clamps / supports within distribution boards cable alley.
All MCB’s shall be of minimum 10 KA breaking capacity.
The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal
magnetic releases upto 250 amps and miroprocesR&B R&B SOR based for 250 amps and above
capacity, unless specified otherwise.
All motor feeders MCCBs shall be of motor duty.
Item no. Description Unit Rate Total Qty. Amount
Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.
Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-
IP 4x for all Indoor panel.
IP 65 and double door for all outdoor panel.
All MCCB’s shall be provided with operating mechanism for door interlock.
All measuring instruments (Meters) shall be of digital electronic with LED of approved make.
All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
All panels shall have provision of the following:
Pad locking of Switch board doors.All MCB’s used for protection of resistive and lightly inductive
load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic
and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air
circuit breakers shall be placed on middle portion of the vertical in single tier formation. SPD as
2.1 SITC OF MAIN PANEL FOR FIRE STATION_HATHIJAN Each 3,25,275.96 1.00
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
2.2 SITC OF COMMON AREA FOR SITE_HATHIJAN Each 2,67,965.86 1.00
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
2.3 SITC OF PHE PANEL_HATHIJAN Each 84,797.20 1.00
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
2.4 SITC OF 1BHK & 2BHK COMMON AREA Each 1,22,320.62 1.00
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
2.5 SITC OF DG PANEL_HATHIJAN Each 3,08,467.15 1.00
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
2.6 SITC OF EXTERNAL LIGHTING PANEL_HATHIJAN Each 91,779.32 1.00
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
2.7 Providing & erecting capacitor duty contactor 3 phase, 415 V with proper connection for following Each 3,217.00 1.00
Item no. Description Unit Rate Total Qty. Amount
2.8 SITC OF APFC PANEL - 75 KVAR Each 2,16,103.00 1.00
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel
Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty
Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at
400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated
Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-
phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and
Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault
relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller
having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for
main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as
per site situation,Cooling fans for panel
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
[FOR HATHIJAN FIRE STATION]
2.9 SITC OF APFC PANEL - 100 KVAR Each 2,86,018.00 1.00
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel
Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty
Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at
400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated
Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-
phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and
Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault
relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller
having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for
main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as
per site situation,Cooling fans for panel
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
[FOR COMMON AREA SITE FOR HATHIJAN]
Sub Total 2.....
2a SERVO STABILIZER
Supply, Installation, testing and commissioning of Indoor Type Three phase servo-controlled
voltage stabilizer suitable for input voltage range 340 to 480VAC up to 200 KVA and above
KVA 360-480VAC And output voltage range 415V + 1%. A.C Three Phase. Natural Air Cooled with
Input MCB / MCCB & Bypass switch (L&T, ABB, schneider) , Air cooled up to 60 KVA & above oil
2a.1 Rating : 40 KVA (Air cooled) Each 88,596.00 1.00
2a.2 Rating : 150 KVA (Oil cooled) Each 2,76,862.50 1.00
Sub Total 2a.....
3 JUNCTION BOXES
Item no. Description Unit Rate Total Qty. Amount
3.1 Supply, Transportation, Installation, testing and commissioning of IP-67 Rated weather proof Each 904.42 2.00
Outdoor type junction boxes having dimensdios Height x Width x Depth:- 104 x 104 x 70 mm with
terminal having black colour RAL 7035. with 5 pole terminal set upto 4 sqmm cables
3.2 Supply, Transportation, Installation, testing and commissioning of IP 66/69 weather proof Outdoor Each 4,072.96 5.00
type junction boxeshaving dimensdios Height x Width x Depth:- 155 x 210 x 92 mm with terminal
having black colour RAL 9011. with 5 pole terminal set upto 16 sqmm cables
Sub Total 3.....
4 DISTRIBUTION BOARD
SPN Distribution Board :
4.1 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 1,141.00 10.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for
(A) Single phase incoming and horizontal single phase outgoing
(b) Sheet Steel double door (IP-43)
4.2 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 1,478.00 68.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for
(A) Single phase incoming and horizontal single phase outgoing
(b) Sheet Steel double door (IP-43)
4.3 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 1,664.00 1.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for
(A) Single phase incoming and horizontal single phase outgoing
(b) Sheet Steel double door (IP-43)
TPN Distribution Board :
Item no. Description Unit Rate Total Qty. Amount
4.4 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 2,885.00 2.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for suitable for (PPI DB)
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation
(b) Sheet Steel double door
4.5 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 3,379.00 30.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for suitable for (PPI DB)
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation
(b) Sheet Steel double door
4.6 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 3,836.00 4.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for suitable for (PPI DB)
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation
(b) Sheet Steel double door
4.7 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted Each 4,620.00 1.00
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for suitable for (PPI DB)
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation
(b) Sheet Steel double door
VTPN Distribution Board :
Item no. Description Unit Rate Total Qty. Amount
4.8 Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / Each 5,760.00 1.00
surface mounted double door (IP54) fitted with copper insulated busbar, isolated neutral bar, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for 63/100 AMP TPN
MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used
of same company of MCB to be used)
(A)4 way outgoing
4.9 Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / Each 6,433.00 2.00
surface mounted double door (IP54) fitted with copper insulated busbar, isolated neutral bar, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for 63/100 AMP TPN
MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used
of same company of MCB to be used)
(B)6 way outgoing
4.10 Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / Each 8,319.00 4.00
surface mounted double door (IP54) fitted with copper insulated busbar, isolated neutral bar, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for 63/100 AMP TPN
MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used
of same company of MCB to be used)
(C)8 way outgoing
4.11 Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / Each 10,857.00 RO
surface mounted double door (IP54) fitted with copper insulated busbar, isolated neutral bar, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for 63/100 AMP TPN
MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used
of same company of MCB to be used)
(D)12 way outgoing
MCB 's and its Accessories
4.12 Providing & erecting insulated socket 3P+N+E with Plug16A rating which is comprised of Four pole Each 1,690.00 1.00
MCB slot and insulated socket IP40 Cat-III.
4.13 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V Each 111.00 1,320.00
A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III.
4.14 Providing & erecting 240 V MCB double pole switch for motor & inductive load having 10 KA Each 297.00 1.00
breaking capacity & confirms to IS : 8828 in existing box having following capacity
(A) 6 to 32 Amp.
4.15 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load having 10KA breaking Each 590.00 31.00
capacity & confirms to IS :8828 in existing box having following capacity
(a) 6 to 32 Amp. ( Cat.III)
Item no. Description Unit Rate Total Qty. Amount
4.16 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load having 10KA breaking Each 662.00 5.00
capacity & confirms to IS :8828 in existing box having following capacity
(b) 40 Amp. ( Cat.III)
4.17 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load having 10KA breaking Each 730.00 6.00
capacity & confirms to IS :8828 in existing box having following capacity
(c) 63 Amp. (cat III)
4.18 Providing & erecting 415 V MCB three Pole for Motor & Inductive Load having 10KA breaking Each 582.00 12.00
capacity & confirms to IS :8828 in existing box having following capacity
(a) 6 to 32 Amp. (Cat.III)
4.19 Providing & erecting 415 V MCB three Pole for Motor & Inductive Load having 10KA breaking Each 641.00 1.00
capacity & confirms to IS :8828 in existing box having following capacity
(b)40 Amp.(Cat.III)
4.20 Providing & erecting 415 V MCB three Pole for Motor & Inductive Load having 10KA breaking Each 709.00 1.00
capacity & confirms to IS :8828 in existing box having following capacity
(C)63 Amp. (Cat.III)
4.21 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of Each 1,950.00 88.00
30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected as directed
(i) 25 Amps.DP ( Cat. III)
4.22 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of Each 2,213.00 15.00
30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected as directed
(ii) 40Amps. DP ( Cat. III)
4.23 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of Each 2,628.00 6.00
30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected as directed
(iii) 63Amps. DP ( Cat. III)
4.24 Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on Each 1,798.00 72.00
residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity &
mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for
rated leakage at nominal ten volt, complete erected including all materials lugs screws etc.
[a] 6A / 10A / 16A / 20A / 25A 2 pole single phase
Item no. Description Unit Rate Total Qty. Amount
4.25 Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on Each 1,925.00 1.00
residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity &
mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for
rated leakage at nominal ten volt, complete erected including all materials lugs screws etc.
[b] 32A / 40A, 2 pole Single Phase
4.26 Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on Each 2,145.00 4.00
residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity &
mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for
rated leakage at nominal ten volt, complete erected including all materials lugs screws etc.
[e] 32A to 40 A, 4 Pole Three Phase
4.27 Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on Each 2,806.00 1.00
residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity &
mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for
rated leakage at nominal ten volt, complete erected including all materials lugs screws etc.
[f] 63A, 4 pole Three Phase
4.28 SITC of Sheet steel metal enclouser for DP MCB Each 175.00 1.00
4.29 SITC of Sheet steel metal enclouser for FP MCB Each 623.00 1.00
4.30 SITC of 80-100 A FP MCCB with thermal magnetic release. Each 6,723.20 1.00
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12 (The
Enclosures should be used of same company of MCCBs to be used) *Add 35% additional for
microprocessor type of mccb in place of conventional for item no.3-4-1 to 3-4-12
4.31 SITC of 125A FP MCCB with thermal magnetic release with sheet steel metal enclosure. Each 8,773.60 1.00
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12 (The
Enclosures should be used of same company of MCCBs to be used) *Add 35% additional for
microprocessor type of mccb in place of conventional for item no.3-4-1 to 3-4-12
4.32 SITC of 200A FP MCCB with thermal magnetic release with sheet steel metal enclosure. Each 17,667.10 2.00
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12 (The
Enclosures should be used of same company of MCCBs to be used) *Add 35% additional for
microprocessor type of mccb in place of conventional for item no.3-4-1 to 3-4-12
Item no. Description Unit Rate Total Qty. Amount
4.33 SITC of 250A FP MCCB with thermal magnetic release with sheet steel metal enclosure. Each 22,812.90 1.00
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12 (The
Enclosures should be used of same company of MCCBs to be used) *Add 35% additional for
microprocessor type of mccb in place of conventional for item no.3-4-1 to 3-4-12
4.34 SITC of 315-400A FP MCCB with thermal magnetic release with sheet steel metal enclosure. Each 27,476.90 2.00
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12 (The
Enclosures should be used of same company of MCCBs to be used) *Add 35% additional for
microprocessor type of mccb in place of conventional for item no.3-4-1 to 3-4-12
4.35 SITC of IP 65 - outdoor type - 4Way SPN DB Each 1,833.45 1.00
4.36 SITC of IP 65 - outdoor type - 8Way SPN DB Each 2,891.68 1.00
4.37 SITC of Blank Plates Each 9.00 84.00
4.38 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal Each 2,024.17 10.00
encloused plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in
recess, with chained metal cover for the socket out let and complete with connections, testing and
commissioning etc. as required.
Sub Total 4.....
5 LT CABLES & CABLE TERMINATION
5.1 UNARMOURED COPPER CABLES.
5.1.1 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 136.00 50.00
erected as directed of following size.
(E) 3 core 2.5 Sq. mm
5.1.2 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 187.00 10.00
erected as directed of following size.
(F) 3 core 4 Sq. mm
5.1.3 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 290.00 500.00
erected as directed of following size.
(G) 3 core 6 Sq. mm
5.1.4 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 167.00 10.00
erected as directed of following size.
(J) 4 core 2.5 Sq. mm
5.1.5 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 238.00 10.00
erected as directed of following size.
(K) 4 core 4 Sq. mm
Item no. Description Unit Rate Total Qty. Amount
5.1.6 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 361.00 10.00
erected as directed of following size.
(L) 4 core 6 Sq. mm
5.1.7 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be Mtr. 568.00 10.00
erected as directed of following size.
(M) 4 core 10 Sq. mm
5.2 ARMOURED ALUMINIUM CABLES
5.2.1 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 152.00 10.00
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of
following size of cables
(A) 4 core 16 Sq. mm
5.2.2 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium Mtr. 139.00 10.00
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of
following size of cables
(C) 4 core 10 Sq. mm
5.2.3 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 182.00 10.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(I) 3 1/2 core 25 Sq. mm( 16 Sq. mm 1/2 core)
5.2.4 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 218.00 260.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(I) 3 1/2 core 35 Sq. mm( 25 Sq. mm 1/2 core)
5.2.5 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 282.00 10.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Item no. Description Unit Rate Total Qty. Amount
5.2.6 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 375.00 10.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
5.2.7 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 486.00 15.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
5.2.8 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 535.00 75.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
5.2.9 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 724.00 260.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core)
5.2.10 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 896.00 610.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
5.2.11 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 1,157.00 100.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
Item no. Description Unit Rate Total Qty. Amount
5.2.12 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium Mtr. 1,394.00 10.00
conductor with water swellable coating which should protect against saline water & for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(I) 3 1/2 core 300 Sq. mm( 150 Sq. mm 1/2 core)
5.3 ARMOURED COPPER CABLES
5.3.1 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 213.00 50.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(A) 3 core 2.5Sq. Mm
5.3.2 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 285.00 365.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(B) 3 core 4 Sq. mm
5.3.3 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 392.00 10.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(C) 3 core 6 Sq. mm
5.3.4 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 495.00 10.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(C) 3 core 10 Sq. mm
5.3.5 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 269.00 10.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(A) 4 core 2.5 Sq. mm
Item no. Description Unit Rate Total Qty. Amount
5.3.6 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 361.00 315.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(B) 4 core 4 Sq. mm
5.3.7 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 505.00 705.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(C) 4 core 6 Sq. mm
5.3.8 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 670.00 160.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(A) 4 core 10 Sq. mm
5.3.9 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor Mtr. 978.00 105.00
with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
(B) 4 core 16 Sq. mm
5.4 CABLE GLANDS.
5.4.1 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated Ea. 33.00 40.00
armoured cable complete with out going tails, insulating tape etc for following size of cables.
(A) 2 to 4 core 2.5/4 Sq. mm
5.4.2 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated Ea. 38.00 24.00
armoured cable complete with out going tails, insulating tape etc for following size of cables.
(B) 2 to 4 core 6 Sq. mm
5.4.3 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated Ea. 38.00 8.00
armoured cable complete with out going tails, insulating tape etc for following size of cables.
(C) 2 to 4 core 10 Sq. mm
Item no. Description Unit Rate Total Qty. Amount
5.4.4 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated Ea. 47.00 6.00
armoured cable complete with out going tails, insulating tape etc for following size of cables.
(D) 2 to 4 core 16 Sq. mm
5.4.5 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 66.00 2.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(B) 3 & 1/2 core 25Sq. mm
5.4.6 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 75.00 8.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(B) 3 & 1/2 core 35/50 Sq. mm
5.4.7 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 102.00 2.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(C) 3 & 1/2 core 70 Sq. mm
5.4.8 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 130.00 2.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(D) 3 & 1/2 core 95 Sq. mm
5.4.9 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 139.00 4.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(E) 3 & 1/2 core 120 Sq. mm
5.4.10 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 189.00 6.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(F) 3 & 1/2 core 150 Sq. mm
5.4.11 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 236.00 10.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(G) 3 & 1/2 core 185 Sq. mm
Item no. Description Unit Rate Total Qty. Amount
5.4.12 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 245.00 4.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(H) 3 & 1/2 core 240 Sq. mm
5.4.13 Providing and, fixing heavy duty flange type brass double compression type cable gland with Ea. 278.00 2.00
rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(I) 3 & 1/2 core 300 Sq. mm
5.5 Aluminium lugs
5.5.1 Supply, installation, testing and commissioning of Solder less crimping type Aluminium lugs Ea. 13.00 4.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.2 Supply, installation, testing and commissioning of Solder less crimping type Aluminium lugs Ea. 15.00 4.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.3 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 20.00 32.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.4 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 25.00 8.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.5 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 40.00 8.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
Item no. Description Unit Rate Total Qty. Amount
5.5.6 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 45.00 16.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.7 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 61.00 24.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.8 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 80.00 40.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.9 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 85.00 16.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.5.10 Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs Ea. 98.00 8.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.6 Copper lugs
5.6.1 Supply, installation, testing and commissioning of Solder less crimping type Copper lugs Ea. 8.00 256.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
Item no. Description Unit Rate Total Qty. Amount
5.6.2 Supply, installation, testing and commissioning of Solder less crimping type Copper lugs Ea. 10.00 32.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
5.6.3 Supply, installation, testing and commissioning of Solder less crimping type Copper lugs Ea. 12.00 24.00
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
Sub Total 5.....
Perforated type cable tray
6.1 Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The Rmt 357.00 20.00
cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support(
included) as per Specification and as per instruction of engineer in charge..
(2) 100 X 50 X 1.6 mm Thick
6.2 Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The Rmt 420.00 90.00
cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support(
included) as per Specification and as per instruction of engineer in charge..
(3) 150 X 50 X 1.6 mm Thick
6.3 Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The Rmt 616.00 10.00
cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support(
included) as per Specification and as per instruction of engineer in charge.
(5) 300 X 50 X 2.0 mm Thick
Item no. Description Unit Rate Total Qty. Amount
6.4 Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made from Ea. 158.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erected on existing support as per Specification and as
per instruction of engineer in charge of following size
(2) 100 X 50 X 1.6 mm Thick
6.5 Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made from Ea. 183.00 5.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erected on existing support as per Specification and as
per instruction of engineer in charge of following size
(3) 150 X 50 X 1.6 mm Thick ' T' Junction
6.6 Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made from Ea. 289.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erected on existing support as per Specification and as
per instruction of engineer in charge of following size
(5) 300 X 50 X 2.0 mm Thick ' T' Junction
6.7 Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from Ea. 115.00 3.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(2)100 X 50 X 1.6 mm Thick 90° Elbow
6.8 Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from Ea. 162.00 14.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(3)150 X 50 X 1.6 mm Thick 90° Elbow
6.9 Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from Ea. 243.00 3.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(5) 300 X 50 X 2.0 mm Thick 90° Elbow
Item no. Description Unit Rate Total Qty. Amount
6.10 Providing and fixing approved make 'Cross over Junction' for Perforated C type cable tray. Ea. 213.00 1.00
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish
plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
(2) 100 X 50 X 1.6 mm Thick Cross Junction
6.11 Providing and fixing approved make 'Cross over Junction' for Perforated C type cable tray. Ea. 242.00 2.00
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish
plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
(3) 150 X 50 X 1.6 mm Thick Cross Junction
6.12 Providing and fixing approved make 'Cross over Junction' for Perforated C type cable tray. Ea. 370.00 1.00
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish
plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
(5) 300 X 50 X 2.0mm Thick Cross Junction
Ladder type cable tray
6.13 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray Mtr. 518.00 110.00
should be bended as per IS 2062/1079 shall be fabricated of double bended channel section
longitudinal members with single bended Channel section. Rungs of members welded to the base
of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(8) 150 X 100 X 1.6 mm Thick
6.14 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray Mtr. 530.00 35.00
should be bended as per IS 2062/1079 shall be fabricated of double bended channel section
longitudinal members with single bended Channel section. Rungs of members welded to the base
of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(9) 200 X 100 X 1.6 mm Thick
Item no. Description Unit Rate Total Qty. Amount
6.15 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray Mtr. 551.00 20.00
should be bended as per IS 2062/1079 shall be fabricated of double bended channel section
longitudinal members with single bended Channel section. Rungs of members welded to the base
of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(10) 300 X 100 X 2.0 mm Thick
6.16 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray Mtr. 658.00 170.00
should be bended as per IS 2062/1079 shall be fabricated of double bended channel section
longitudinal members with single bended Channel section. Rungs of members welded to the base
of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(12) 500 X 100 X 2.0 mm Thick
6.17 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray Mtr. 688.00 50.00
should be bended as per IS 2062/1079 shall be fabricated of double bended channel section
longitudinal members with single bended Channel section. Rungs of members welded to the base
of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(13) 600 X 100 X 2.0 mm Thick
6.18 Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from M.S Ea. 619.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(8) 150 X 100 X 1.5 mm Thick 'T' Junction
6.19 Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from M.S Ea. 653.00 3.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(9) 200 X 100 X 1.5 mm Thick 'T' Junction
Item no. Description Unit Rate Total Qty. Amount
6.20 Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from M.S Ea. 700.00 4.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(10) 300 X 100 X 2.0 mm Thick 'T' Junction
6.21 Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from M.S Ea. 967.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(12) 500 X 100 X 2.0 mm Thick 'T' Junction
6.22 Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from M.S Ea. 1,077.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(13) 600 X 100 X 2.0 mm Thick 'T' Junction
6.23 Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from M.S Ea. 437.00 4.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(8) 150 X 100 X 1.6 mm Thick
6.24 Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from M.S Ea. 467.00 5.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(9) 200 X 100 X 2.0 mm Thick
6.25 Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from M.S Ea. 531.00 6.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(10) 300 X 100 X 2.0 mm Thick
Item no. Description Unit Rate Total Qty. Amount
6.26 Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from M.S Ea. 721.00 3.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(12) 500 X 100 X 2.0 mm Thick
6.27 Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from M.S Ea. 806.00 3.00
sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge..
(13) 600 X 100 X 2.0 mm Thick
6.28 Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from Ea. 729.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(8) 150 X 100 X 1.6 mm Thick
6.29 Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from Ea. 759.00 2.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(9) 200 X 100 X 2.0 mm Thick
6.30 Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from Ea. 823.00 1.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(10) 300 X 100 X 2.0 mm Thick
6.31 Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from Ea. 1,069.00 1.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(12) 500 X 100 X 2.0 mm Thick
Item no. Description Unit Rate Total Qty. Amount
6.32 Providing and fixing approved make 'Cross over Junction' for ladder type cable tray. Made from Ea. 1,174.00 1.00
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in
(13) 600 X 100 X 2.0 mm Thick
6.33 Supplying , fabricating and installation of various sizes clamps for cable tray supports using Kg 77.00 890.00
available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant
including applying zinc chromate yellow oxide and two to three coats of required enamel paints with
anchor fasteners etc.
Sub Total 6.....
7 INTERNAL WIRING
7.1 Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth wire of Pt. 174.30 1,210.00
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand
copper wires, in below type of pipe to be erected complete with earth continuity and necessary
connection with primary light with accessories erected on Metal / PVC / wooden box covered with
3 mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with necessary Lamp
holder / ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
7.2 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of Pt. 505.05 900.00
ISI marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr
length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and
earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per
pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete(cat lll)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Item no. Description Unit Rate Total Qty. Amount
7.3 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI Pt. 701.40 380.00
marked 1.1 KV Grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic
fan regulator mounted and accessories with earth continuity of following type erected on PVC /
Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete(cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
7.4 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked Pt. 530.25 1,100.00
1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as
per pipe erected with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete (cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
7.5 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked Pt. 774.90 315.00
1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as
per pipe erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete (cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Item no. Description Unit Rate Total Qty. Amount
7.6 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked Pt. 906.15 345.00
1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as
per pipe erected with following type of accessories.
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green)
earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete (cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
7.7 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC Pt. 267.75 585.00
/ Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front
plate modules erected on / in wall / ceiling with following type accessories
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
7.8 Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm Pt. 627.90 120.00
(green) both are of .ISI marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper
wires erected in below type of pipe with 6A Modular type switches and following type of accessories
erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary
batten/angle holder or ceiling rose or H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete(cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in Item of
Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
7.9 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 62.00 1,050.00
conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with
sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm
7.10 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 82.00 50.00
conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with
sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of
(A) With medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm
Item no. Description Unit Rate Total Qty. Amount
7.11 providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 111.00 50.00
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm
7.12 providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 146.00 1,240.00
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(b) 2 wire 6 sq. mm
7.13 providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 234.00 1,280.00
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(c) 2 wire 10 sq. mm
(use earth wire of 4 sq.mm )
7.14 providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 258.00 810.00
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(h) 4 wire 6 sq. mm
7.15 providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper Rmt. 421.00 140.00
conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm )
7.16 Providing & erecting Switch board for Computer or electric apparatus consisting of following Pt. 1,122.00 35.00
modular type accessories mounted with PVC / Metallic concealed/open box with single mounting
base frame covered with textured/metallic /white front plate,modules erected with necessary
connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type accessories Cat. III
Item no. Description Unit Rate Total Qty. Amount
7.17 SITC of following type of Modular Type accessories mounted with PVC / metallic/Wooden box, Ea. 395.00 380.00
single mounting base frame covered with textured / metallic/white front plate , modules erected
with necessary connections as per site situation directed by Engineer In charge.
(5) Electronic hum Free four or more steps EME Fan regulator (cat III)
7.18 providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed Mtr. 298.00 100.00
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel, relays, power switchgears, motor
starters & control wiring) with required size of copper lugs, nuts and bolts if required.
(i) One wire 35.00 sq. mm
7.19 Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, Ea. 159.00 200.00
single mounting base frame covered with textured / metallic/white front plate , modules erected
with necessary connections as per site situation directed by Engineer In charge.
(4) TV Co-axial Socket outlet
7.20 SITC of following type of Modular Type accessories mounted with PVC / metallic/Wooden box, Ea. 25.00 25.00
single mounting base frame covered with textured / metallic/white front plate , modules erected
with necessary connections as per site situation directed by Engineer In charge.
(7) Blank Plate Single (cat III)
7.21 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be Ea. 33.00 100.00
erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & Clamps with following dia of pipes, in approved manner as directed
7.22 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be Ea. 54.00 100.00
erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & Clamps with following dia of pipes, in approved manner as directed
7.23 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be Ea. 67.00 50.00
erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with
adhesive solution & Clamps with following dia of pipes, in approved manner as directed
7.24 Batten Holder/Angle Holder with modular frame with metal ring. Ea. 64.00 740.00
Sub Total 7.....
8 INDOOR LIGHT FIXURE
8.1 Supply, Installation Testing and Commissioning of 20W CEILING/WALL MOUNTED TUBE Each 293.00 12.00
(A) Tube Light with integral driver
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet
Item no. Description Unit Rate Total Qty. Amount
8.2 Supply, Installation Testing and Commissioning of 36W CEILING/WALL MOUNTED TUBE Each 530.00 80.00
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet
8.3 Supply, Installation Testing and Commissioning of 10W WALL MOUNTED MIRROR LIGHT Each 309.00 12.00
(H) Mirror Light 9 Watts, wall mounted minimum 1 feet long
8.4 Supply, Installation Testing and Commissioning of 24W CEILING SURFACE MOUNTED Each 751.00 940.00
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV
8.5 Supply, Installation Testing and Commissioning of 24W CEILING RECESSED MOUNTED Each 751.00 115.00
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV
8.6 Supply, Installation Testing and Commissioning of 18W CEILING SURFACE MOUNTED Each 584.00 120.00
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV
8.7 Supply, Installation Testing and Commissioning of 18W CEILING RECESSED MOUNTED Each 584.00 25.00
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV
8.8 Supply, Installation Testing and Commissioning of 10W CEILING SURFACE MOUNTED Each 423.00 25.00
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV
8.9 Supply, Installation Testing and Commissioning of 10W CEILING RECESSED MOUNTED Each 423.00 30.00
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV
8.10 Supply, Installation Testing and Commissioning of Flood Light: Each 9,552.00 16.00
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply
with over-voltage protection.
(vi) above 160 to 200 watts
Item no. Description Unit Rate Total Qty. Amount
8.11 Ceiling Fan: Each 1,929.00 380.00
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing
ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with
aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved
by Engineer in charge))
8.12 SITC of approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with Each 1,687.00 290.00
square frame.ABS body with inbuilt lowers & square frame.
8.13 SITC of suitable M.S. louver shutter of the Exhaust fan. Each 365.00 290.00
8.14 Wall bracket fan: Each 2,509.00 2.00
Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450
mm sweep wall mounted with height adjustment and rotary tilting device complete with guard,
flexible Core plug top complete erected with lead wires as directed.
Sub Total 8.....
9.1 SITC of required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Kg. 77.00 1,115.00
Transformer LT panel board, Motors etc. using proper clamp.
9.2 SITC of required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Kg. 787.00 180.00
Motors etc. using copper clamp.
9.3 SITC of Annealed bare Copper wire 8 to 16 SWG. Kg. 787.00 100.00
9.4 SITC of HOT deep Galvanised iron strip wire 8 to 16 SWG. Kg. 77.00 15.00
9.5 Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode Each 8,551.00 55.00
consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover. (A)(approved make OEM has to submit
test certificate including value of earth resistance of installation duly stamped and signed by agency
and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long
time Necessary test report must be submitted by Agency.
(c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant
& Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Sub Total 9......
Item no. Description Unit Rate Total Qty. Amount
10.1 Supplying and erecting approved make online Un-interruptible Power Supply system comprising Each 47,425.00 1.00
flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF
batteries. The charger having operating capacity for input 160-270V AC & inverter having output
230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load &
short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with
following power backup.with MS painted batteries stand, 10% Overload capacity for momentary
(B) 2KVA with 1Hr Backup
10.2 Supplying and erecting approved make online Un-interruptible Power Supply system comprising Each 1,28,815.00 1.00
flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF
batteries. The charger having operating capacity for input 160-270V AC & inverter having output
230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load &
short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with
following power backup.with MS painted batteries stand, 10% Overload capacity for momentary
(D) 5KVA with 1Hr Backup
10.3 Supplying and erecting approved make online Un-interruptible Power Supply system comprising Each 5,75,425.00 1.00
flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF
batteries. The charger having operating capacity for input 160-270V AC & inverter having output
230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load &
short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with
following power backup.with MS painted batteries stand, 10% Overload capacity for momentary
(K) 30 KVA 3 - phase with 1Hr Backup
Sub Total 10......
11 SAFETY ITEMS
11.1 SITC of metallic vitrified danger notice board as per language suggested by engineer incharge for Ea. 69.00 10.00
MEDIUM VOLTAGE installation to be erected as per IS-2551.
11.2 SITC of metallic vitrified danger notice board as per language suggested by engineer incharge for Ea. 81.00 1.00
HIGH VOLTAGE installation to be erected as per IS.2551.
11.3 SITC of printed instruction chart both in English and Gujarati and duly framed with front glasses, for Ea. 129.00 1.00
treatment of person suffering from Electric shock with minimum 50" diagonally size.
11.4 SITC of pair of rubber hand gloves suitable for working on 11 KV supply. Ea. 212.00 1.00
11.5 SITC of rubber matting of 3 mm thickness as per IS 15652 and IEC 61111. Sq.mtr 763.00 20.00
11.6 SITC of stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe Ea. 297.00 5.00
bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal
user, ScisR&BR&BSORs, anti-septic solution (Savlon or similar) etc. (All above contents shall be of
standard makes)
Item no. Description Unit Rate Total Qty. Amount
11.7 SITC of FIREbucket round bottom of9 litres capacity made out of 24 gauge G.I. sheet with extra Ea. 212.00 1.00
handle at bottom duly painted white inside andRed out side with FIRE mark,filled with dry-sand and
kept on existing stand provided or hung on wall hook.
11.8 SITC of floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, Ea. 933.00 1.00
900 mmheight frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs,
welded with 4 hooks and duly painted with one coat of red lead and two coats of approved
enamelled silver paint.
11.9 Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod Ea. 60.00 1.00
grouted in wall to a depth of minimum 15 cms.
11.10 Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun Ea. 1,696.00 5.00
metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and
complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts
grouted in wall complete.
[A] For 5 Kg Capacity
11.11 Supply and installtion of expanding firestop foam equivalent to Hilti CP 620 on both sides of wall, Ea. 10,643.83 5.00
with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for
horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after passing service
lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume
to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after
dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall
provide water tightness when tested for W rating as per UL standards and shall carry test certificate
for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product shall carry
test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a
VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with
IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history
method and VERTEQII for seismic zone 4. The system shall be UL listed & classified. The system
shall be UL & FM approved.
11.12 Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum 2 hours Sq. mtr 13,043.30 10.00
fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings
in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar
shall be a light weight cementitious product and shall carry test certificate in accordance with IEC
60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history
method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT
standards. The product shall carry test certificate for mold resistance rating of 0 as determined by
ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system
shall be UL listed. The gaps around inaccessible or complicated openings shall be sealed with
exapnding firestop foam.
Sub Total 11.....
12 EXTERNAL LIGHT FIXTURE AND POLE
Item no. Description Unit Rate Total Qty. Amount
12.1 PLANT UPLIGHTER Each 3,445.40 10.00
SITC of Plant Uplighter:
System Wattage : 12W LED,Driver Integral : Constant Current,Operating Voltage : 100-
300Vac,Operating Temperature : -15°C~+50°C,Body : Die-cast Aluminium Alloy,Diffuser : Clear
Toughened Glass,Mounting : Spike / Die-castAluminium BracketFinish : Powder coated.Light
Source : CITIZEN.CRI (Ra) : ≥80.LED Colour Temperature : 3000K.Driver Power Supply :
Integral.Input Voltage : 230-240Vac.Frequency : 50-60 Hz.Power Factor : >0.95.
THD : <10%.Surge Protection : 4KV.Efficiency : >80%.Beam Angle : 25°.IP66
12.2 Supply of approved make frp/grp pole having followiing specifications : Each 8,637.00 20.00
FRP/GRP pole made by centrifugal moulding process using thermoset resin polyester/epoxy resin
system having minimum glass content 45.0%.The pole should be in one pieceand tapered round in
shape,having smooth outside surface finish and should be totally fre from corrosion as well as non
conductive and shock proof. Pole should be provided with FRP/GRP base bracket dully fabricated
from metal(M.S) and dully claded with FRP/GRP material to avoid any metal exposer and painted
with PU paint.Pole should mechanical properties i.e 1. Specfic gravity (ASTM D 792) 1.3‑1.8
Kg/m3, 2. Glass Content % by weight (ASTM D 2584) 45.0 ‑55.0%, 3. Water absorption (ASTM D
<0.5%, 4. Tensile Strength(ASTM D 638) 200+/‑50Mpa, 5. Flexural strength (ASTM D 790)
250+/‑50Mpa, 6. Compressive Strength (ASTM D 695) 200+/‑50MPa, 7. Yeild Strength(ASTM
D638) 250 +/‑50MPa.Pole should be flame retardant as per IS 6746.Resin used shall be UV
resistance and pigmented. Pole should be painted with first coat of epoxy primer and then two coat
of highly weather resistance polyurethen paint to ensure proper addhesion of the paint.Minimum
thickness shall be 80 to 100 micron.Defelection of the pole shall not exceed more than 10.0 % of
the length of the pole for the given load.Pole should be generally made as per the dimensional
data,performance criteria and some interchagebility features of poles as per the standard ANSI
C123.20 latest version of ASTM D 923/01 including cable termination box with necessory
accessories.The size of pole and type of installation with foundation , Anchor Base & Internal
junction box as per the manufacturer details and site requirement .
(1) 'A' class frp/grp pole suitable for base plate mounting
[B] Overall Length of 4.0 meter, Average thickness : 4mm, Top/Bottom Outside Dia. 76/143mm +/ ‑
2.Weight of Pole 10.0 Kg approx. (Without base) Metal Anchor Base dully frp claded (Size : 290 Ø
* 12mmthk , Mounting hole PCD 240mm * 4 nos. of 16 Ø hole)
(Color of pole shall be as per architeture intent)
Item no. Description Unit Rate Total Qty. Amount
12.3 Supply of approved make frp/grp pole having followiing specifications : Each 13,468.00 5.00
FRP/GRP pole made by centrifugal moulding process using thermoset resin polyester/epoxy resin
system having minimum glass content 45.0%.The pole should be in one pieceand tapered round in
shape,having smooth outside surface finish and should be totally fre from corrosion as well as non
conductive and shock proof. Pole should be provided with FRP/GRP base bracket dully fabricated
from metal(M.S) and dully claded with FRP/GRP material to avoid any metal exposer and painted
with PU paint.Pole should mechanical properties i.e 1. Specfic gravity (ASTM D 792) 1.3‑1.8
Kg/m3, 2. Glass Content % by weight (ASTM D 2584) 45.0 ‑55.0%, 3. Water absorption (ASTM D
<0.5%, 4. Tensile Strength(ASTM D 638) 200+/‑50Mpa, 5. Flexural strength (ASTM D 790)
250+/‑50Mpa, 6. Compressive Strength (ASTM D 695) 200+/‑50MPa, 7. Yeild Strength(ASTM
D638) 250 +/‑50MPa.Pole should be flame retardant as per IS 6746.Resin used shall be UV
resistance and pigmented. Pole should be painted with first coat of epoxy primer and then two coat
of highly weather resistance polyurethen paint to ensure proper addhesion of the paint.Minimum
thickness shall be 80 to 100 micron.Defelection of the pole shall not exceed more than 10.0 % of
the length of the pole for the given load.Pole should be generally made as per the dimensional
data,performance criteria and some interchagebility features of poles as per the standard ANSI
C123.20 latest version of ASTM D 923/01 including cable termination box with necessory
accessories.The size of pole and type of installation with foundation , Anchor Base & Internal
junction box as per the manufacturer details and site requirement .
(1) 'A' class frp/grp pole suitable for base plate mounting
[D]Overall Length of 6.0 meter, Average thickness : 5mm, Top/Bottom Outside Dia. 76/176mm +/ ‑
2.Weight of Pole 19.0 Kg approx. (Without base) Metal Anchor Base dully frp claded (Size : 340 Ø
* 12mmthk , Mounting hole PCD 285mm * 6 nos. of 20 Ø hole)
(Color of pole shall be as per architeture intent)
12.4 Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the Each 801.00 25.00
pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm
dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner.
( for 4 & 6 mtr pole)
Item no. Description Unit Rate Total Qty. Amount
12.5 Supply, Installation Testing and Commissioning of Street Light: Each 3,312.00 20.00
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage.
(i) above 36 to 48 watts
Note: All lighting fixture colour to be matched with architecture finishes.
12.6 Supply, Installation Testing and Commissioning of Street Light: Each 4,948.00 5.00
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of
3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage.
(ii) above 48 to 60 Watts
Note: All lighting fixture colour to be matched with architecture finishes.
12.7 Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with suitable brass 145.00 25.00
studs with nuts, washers and clamps of size 25mm x 3mm suitable for pole painted with one coat of Nos.
red lead paint.
12.8 Supplying and erecting Water tight M.S.Box of size 20 x 15 x 15 cm. to erect suitable kitkat fuse / 232.00 1.00
MCB to be . erected on polished wooden board inside the box with hinged/sliding door with rubber
rings and erected on pole with suitable pole clamp, all duly painted with one coat of red oxide and Nos.
two coats of paints. (Cost of Fuse / MCB shall be taken extra)
12.9 Providing & erecting approved make street light / wall mounting junction box compression 610.00 25.00
moulded from SMC (thermoset plastic) vertical sliding cover having locking with square head
stud loop in / loop out in built terminal suitable for four core cable, waterproof of I.P. 54 protected Each
with clamp or bolt nut & earth bolt of following size
Item no. Description Unit Rate Total Qty. Amount
12.10 Providing FRP/GRP arm bracket of having 15˚ arm with 50 mm OD pipe *5 mm thk,1000mm long Each 1,882.00 25.00
from pole centre
(A) Single arm bracket
12.11 Providing FRP/GRP arm bracket of having 15˚ arm with 50 mm OD pipe *5 mm thk,1000mm long Each 2,390.00 1.00
from pole centre
(B) Double arm bracket
12.12 Supplying and erecting B class Galvanized iron pipe having smooth finished bore of the pipe on 247.00 50.00
both ends erected nuts and bolts along the pole / wall shaping the pipe as per site requirement.
Pipe dia as following. Rmt
12.13 Painting of street light pole having post top lantern complete with primer with two coats of 213.00 RO
Aluminium paint.
12.14 Painting of street light pole with bracket complete with two coats of Aluminium paint for following 213.00 25.00
size of pole. Nos.
(A) up to 4 mtr
12.15 Painting of street light pole with bracket complete with two coats of Aluminium paint for following 263.00 5.00
size of pole. Nos.
(B) up to 6 mtr.
12.16 STEP LIGHT Nos. 1,611.96 20.00
SITC of Step Light:
System Wattage : 12W LED,Driver Integral : Constant Current,Operating Voltage : 100-
277Vac,Operating Temperature : -15°C~+50°C,Body : Die-Cast Aluminium,Diffuser : Clear
Acrylic,Gasket : Silicone,Mounting Sleeve : ABS Plastic,Mounting : Wall - Recess,Finish : Powder
coated,Light Source : NICHIA,CRI (Ra) : ≥80,LED Colour Temperature : 3000K,Driver Power
Supply : Integral,Input Voltage : 230-240Vac,Frequency : 50-60 Hz,Power Factor : ≥0.90,THD :
<10%,Surge Protection : 2KV / 2.5KV,Efficiency : >85%,IP65
Sub Total 12.....
13 DWC PIPE AND CHAMBER
13.1 SITC of R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on Mtr. 340.00 10.00
floor with necessary material in an approved manner and making the ground as per original.
13.2 SITC of R.C.C. Hume pipe for cable to be laid 90 cms. below ground across the road crossing or on Mtr. 261.00 50.00
floor with necessary material in an approved manner and making the ground as per original.
Item no. Description Unit Rate Total Qty. Amount
13.3 SITC of approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS Mtr. 62.00 100.00
14930 II )with necessary connecting accessories of same material at required depth in existing
trench for laying of cable. below ground / road surface for enclosing cable.
(A)50 mm outer dia
13.4 SITC of approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS Mtr. 73.00 350.00
14930 II )with necessary connecting accessories of same material at required depth in existing
trench for laying of cable. below ground / road surface for enclosing cable.
(B)63mm outer dia
13.5 SITC of approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS Mtr. 136.00 225.00
14930 II )with necessary connecting accessories of same material at required depth in existing
trench for laying of cable. below ground / road surface for enclosing cable.
(D)120 mm outer dia
13.6 Excavating hard Murrum or Metal road by chiselling for preparing pit for poles or earth plates or for Cu.Mtr 238.00 200.00
laying pipes & clearing the site by removing debris & making site good.
Sub Total 13.....
14.1 SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Nos. 9,323.00 4.00
Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test:
100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-
1 2017 protocol with MAST 34mm dia 3000 mm long- Cold Galvanized
14.2 SITC of 16mm Dia Aluminium Air termination 3000mm Long with 2 nos SS Clamp Suitable for side Nos. 5,484.83 2.00
mounting on wall;Universal cross and T Connector -SS -for 8mm and 16mm dia conductor
14.3 SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- Meter 297.00 200.00
2 conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/IEC
62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance,
Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece with connectors at
every 20 mtr distance, Aluminium straight Splicer to connect conductors. All Accessories should be
tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse
current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a
sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements
Item no. Description Unit Rate Total Qty. Amount
14.4 SITC of 10 mm MS Round Solid Conductor having smooth surface Should be tested and use Meter 721.00 210.00
exclusively for lightning protection (Vertical Riser/Down Conductor which shall be concealed in
Column) to meet the requirement of IS IEC 62305 With Accessories - Earthing stud of dimension
SS-75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to
meet the requirements of IS/IEC 62305. (For Interconnecting the Column and the Terrace AL
Conductor / Strip/Flat), SS Cross Connector to connect Earth fixing point to vertical raiser/Down
conductor, SS Straight Splicer at every 4 Mtr to connect MS conductor in column, Bonding /Rebar
Clamp at every 3 mtr suitable for interconnecting round conductor with reinforcement inside the
concrete for structural earthing system, SS connector -To connect external conductor 8- 10 mm
with earth fixing point. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for
conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs
waveform(Ageing & Electrical test )
conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet
the requirements of IS/IEC
14.5 SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in ground as Meter 153.00 55.00
required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested and used exclusively for
lightning protection earthing system and ring equipotential bonding.
14.6 SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron set 5,933.00 5.00
copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested as per IEC 62561-
7 in NABL accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust
proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm
dia (top), 330 mm dia (bottom) & 260 mm (height).
Sub Total 14.....
15 SERVICE WORK
Liasoning work for power supply procurement (New Service/Load Ext./reduction/Shifting) with Site
Visit, Test Report Submission, Meter Connection in T.P.L/U.G.V.C.L. and Also all necessary work
as per site as and when require.
15.1 Single site more than 10 No. of Service Connection. Per Service 1,500.00 87.00
15.2 Liasoning Work of HIgh Rise NOC Job 25,000.00 1.00
Sub Total 15.....
16 RACEWAY/TRUNKING & JUNCTION BOX
16.1 Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 Mtr. 295.00 10.00
mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed
water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge
and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having
following size of dimensions and No of compartments (W x D x T) Cat-III
[1] 50mm x 25mm x 1.6 mm with One Compartment
Item no. Description Unit Rate Total Qty. Amount
16.2 Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 Mtr. 454.00 18.00
mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed
water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge
and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having
following size of dimensions and No of compartments (W x D x T) Cat-III
[3] 100mm x 25mm x 1.6 mm with one compartment
16.3 Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 Mtr. 965.00 10.00
mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed
water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge
and laying/erecting as per OEM guidelines and as per instruction of engineer incharge having
following size of dimensions and No of compartments (W x D x T) Cat-III
[4] 225mm x 25mm x 1.6 mm with Three Compartment
16.4 Supply, installation, testing and commissioning of following sizes of Floor junction boxes having Ea. 1,923.27 4.00
Back Box made from hot-dip pre-galvanized 275 GSM zinc coated steel sheet having specification
as per IS277:2003 with base box thickness not less than 1mm. Back Box formation should be done
by assembling sheared and bent modular parts. Lid of the junction box should be made from 2.5mm
thick, epoxy coated steel sheet. Lid formation should be done by shearing, bending, and welding
steel sheet to form 8mm recess to accommodate floor tile, stone, or carpet. Trap cover screws
should be made from stainless steel for extra protection. Height adjustable support pillars should be
made from high pressure die cast aluminum and provided with adjustable height from 55mm to
70mm. Modular side wall of the box should be provided with knockout suitable to accommodate
raceway of 25mm and 38 mm height. The junction box should be having IP rating of 20 with
temperature handling capacity of -5˚ c to 60˚ c. The junction box should be able to bear load up-to
2.5 Ton/m2 as per IEC 61084-1:2017 & 61084-2-2:2017 standards. Earth wire connector should be
provided in all the boxes. Throwaway lid should be provided free of cost to protect from water
seepage during cementing/screeding process at site. Size - 150x150x55-70mm
Item no. Description Unit Rate Total Qty. Amount
16.5 Supply, installation, testing and commissioning of following sizes of Cross over junction boxes Ea. 2,825.23 4.00
having Back Box made from hot-dip pre-galvanized 275 GSM zinc coated steel sheet having
specification as per IS277:2003 with base box thickness not less than 1mm. Back Box formation
should be done by assembling sheared and bent modular parts. Lid of the junction box should be
made from 2.5mm thick, epoxy coated steel sheet. Lid formation should be done by shearing,
bending, and welding steel sheet to form 8mm recess to accommodate floor tile, stone, or carpet.
Trap cover screws should be made from stainless steel for extra protection. Height adjustable
support pillars should be made from high pressure die cast aluminum and provided with adjustable
height from 55mm to 70mm. Modular side wall of the box should be provided with knockout suitable
to accommodate raceway of 25mm and 38 mm height. The junction box should be having IP rating
of 20 with temperature handling capacity of -5˚ c to 60˚ c. The junction box should be able to bear
load up-to 2.5 Ton/m2 as per IEC 61084-1:2017 & 61084-2-2:2017 standards. Crossover junction
box with epoxy powder coated flyover should be available to make crossover of all sizes required in
BOQ and facilitate segregation and 90° crossing between data and power wherever desired. Earth
wire connector should be provided in all the boxes. Throwaway lid should be provided free of cost
to protect from water seepage during cementing/ screeding process at site. Size - 250x250x55-
16.6 Supplying , fabricating and installation of various sizes junction boxes made out to 14 gauge sheet Kg 179.00 2.00
with all necessary accessories & hardware etc All the necessary fabrication required will be
included in the scope of contractor. Scope also includes two coat of primer and two coat of paining
of each items on all the sides complete in all respect.
16.7 Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid Mtr. 1,309.00 50.00
material with ignition free and flame proof confirming BS with necessary end caps Internal and
external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following
(4)100 mm x 50 mm trunking with TWIN compartment With clip in divider
16.8 Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid Mtr. 187.00 10.00
material with ignition free and flame proof confirming BS with necessary end caps Internal and
external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following
(3) 50 mm x 50 mm trunking
16.9 Providing & Erecting eight module pop up floor box/flushed with table surface Conform to IEC Ea. 1,529.00 1.00
60670-1, IEC 60670-23 & IEC 60884-1 with required items as demanded by engineer in charge
with complete finishing .cat-III
16.10 Supply & installation of modular type accessories for U PVC snap-on adaptable trunking/Pop up Ea. 204.00 1.00
Box with required items erected with necessary connection. As desired by Engineer In charge
i) 6 A SP 1 Way Switch cat-III
Item no. Description Unit Rate Total Qty. Amount
16.11 ii) 16A SP 1 Way Switch cat-III Ea. 351.00 2.00
16.12 iii) Bell Push 6 A SP 1 Way cat-III Ea. 288.00 2.00
16.13 iv) 6A universal socket shuttered cat-III Ea. 347.00 2.00
16.14 iv) 6/16 A universal socket shuttered cat-III Ea. 458.00 1.00
16.15 v) RJ-11 Telephone socket cat-III Ea. 244.00 2.00
16.16 vi) Cat-6 LAN Socket cat-III Ea. 561.00 2.00
16.17 Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black surface/concealed of Mtr. 107.00 10.00
following size complete to be erected on/in wall or ceiling with erected with necessary saddles,
screws, bends, junction boxes etc. with following (Nominal Bore) dia of pipes, in approved manner
16.18 Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black surface/concealed of Mtr. 138.00 10.00
following size complete to be erected on/in wall or ceiling with erected with necessary saddles,
screws, bends, junction boxes etc. with following (Nominal Bore) dia of pipes, in approved manner
16.19 Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black surface/concealed of Mtr. 226.00 10.00
following size complete to be erected on/in wall or ceiling with erected with necessary saddles,
screws, bends, junction boxes etc. with following (Nominal Bore) dia of pipes, in approved manner
Sub Total 16.....
Total Of Electrical Items Amount in Rs.
17 FIRE DETECTION & ALARM SYSTEM
Item no. Description Unit Rate Total Qty. Amount
17.1 Supply, Installation, Testing and Commissioning of Intelligent Addressable Fire Alarm Control Each 6,38,517.52 1.00
Panel. The Fire Alarm Control panel shall have Built in 6 Loops and expandable upto 16 loops with
each supporting 127 devices of any combination, and 127 analog sounder bases. It shall have UL
listed, 4 programmable class B (style Y) NAC circuits rated 2.5 Amps each, Class B or 2 Class A
with internal synchronization. The user shall have a choice of using the panel with 5.25 A (charges
up to 60 Ah) or 10.25 A (charges up to 100 Ah) power supply. The Panel shall have 3 voltage-free
programmable inputs and 5 programmable relay outputs 30 V DC 1 Amp, 7 inch full-color resistive
touch screen with intuitive user interface, Up to 24 programmable soft “function keys”, Up to
user login accounts, Hard-wired fire and trouble routing inputs and outputs, Modular and
expandable electronics, 400 sub address points per loop (800 per loop module), Option to “invert”
inputs and outputs. The panel shall support up to 5000 programmable Cause and Effects entries;
over 40,000 inputs and outputs, minimum 10,000 events log @ 1 second resolultion, 2000 software
zones, 5000 software groups, 2 AUX 24V output each rated at 900 mA, Can be networked with
programmable functionality, Programming via USB port to PC or memory stick. The Panel shall
have dedicated RS232 serial port for optional printer, UL approved.
17.2 Supply, Installation, Testing & Commissioning of Network Vision Annunciator. The Annunciator Each 1,32,524.85 2.00
shall have Full color 7” (800 x 480 pixel) interface, Replicates information displayed at the FACP,
Automatic display brightness adjustment, Internal buzzer, Connects via control panel network
terminals, Low current, 24V DC powered, Configurable functionality, Enable key-switch, Sheet steel
enclosure, UL approved
17.3 Supply, Installation, Testing and Commissioning of Analog Multi-Criteria Sensor Features, Low Each 5,490.49 130.00
profile - only 2" high including base, variable sensitivity from 0.7 to 4% obs/Ft Simple and reliable
device addressing, Automatic compensation for sensor contamination , Built in Fire test feature,
Two built-in power/alarm LEDs, programmable non-polling LEDs, Non-directional Smoke chamber,
Vandal resistant security locking feature, Approved by UL and FM
17.4 Supply, Installation, Testing and Commissioning of Fixed Temperature/Rate of Rise sensor, Low Each 4,741.12 3.00
profile-only 2.00" high, including base, simple and reliable device addressing method, Rate of rise
temperature threshold = 15° F/Min, Adjustable threshold temperature = 135° - 190°, Approved by
17.5 Supply, Installation, Testing and Commissioning of Multi-Criteria Sensor Each 14,624.49 85.00
(Smoke+Heat+CO) Features, Low profile - only 2" high, Simple and reliable device addressing,
Supports 16 operational modes, Automatic compensation for sensor contamination , Built in Fire
test feature, Two built-in power/alram LEDs, programmable non-polling LEDs, Non-directional
Smoke chamber, Vandal resistant security locking feature, 10 years CO sensor life span, Approved
17.6 Supply, Installation, Testing and commissioning of sensor common mounting base, includes Each 422.06 137.00
stainless steel contacts, slim profile - only 8mm, quick connection via square cable clamps,
facility for remote indicator, Approved by UL
17.7 Supply, Installation, Testing and commissioning of sensor common mounting base, Features Each 2,816.61 19.00
integral Short-Circuit isolator, slim profile, Approved by UL
Item no. Description Unit Rate Total Qty. Amount
17.8 Supply, Installation, Testing and Commissioning of Addressable Single Action Manual Pull Each 8,420.31 30.00
Station features including Addressable intergrated design, All metal construction, Extremely easy
to operate, Bi-colored status LED indicates standby and Alarm conditions, Address is
programmable in EEPROM, Enclosed switch with glass rod, Terminals accept up to 14AWG wire,
ADA compliant. Approved by UL and FM
17.9 Supply, Installation, Testing and Commissioning of low profile Horn/Strobe. The device shall have Each 11,794.34 40.00
Nominal voltage 24VDC. The device shall produce 100 dBA @ 10ft and has a minimum flash rate
of 1Hz regardless of input voltage. The device approved by UL and CSFM
17.10 Supply, Installation, Testing and Commissioning of Fast Response Contact Monitoring Module. Each 4,795.26 30.00
The Module shall have UL 864 9th Edition Listed, Single Input contact monitor, can be programmed
to monitor Normally Open (NO) or Normally Closed (NC) contacts, operates on Class A or Class B
SLC loop, Accepts up to 12 AWG wire. Approved by UL and FM
17.11 Supply, Installation, Testing and Commissioning of Class A Supervised Output Module. The Each 8,463.38 30.00
Module shall have Flexible application, Quick response to emergency conditions, Contacts are
rated 2.0 Amps@ 24VDC, Programming is highly flexible providing 16 prioriy states plus zoning
capability, Approved by UL and FM
17.12 Supply, Laying and Fixing of Red back box for mounting of detector, MCP and module Each 189.50 268.00
17.13 Supply, Laying and Fixing of 2 Core X 1.5 Sq.mm FRLS Multistrand PVC insulated Copper Mtr 189.50 3,000.00
armoured RED cable with all required accessories.
Sub Total 17.....
18 PUBLIC ADDRESS SYSTEM
18.1 SITC of Controller Public address and emergency sound system control unit Nos. 2,20,124.00 1.00
Control and routing of 4 simultaneous audio channels
One controller supports 12 zones, expandable up-to 492 zones with 24-zone routers
Four controllers can be networked using OMNEO interface module
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
18.2 SITC of Router Expansion of PAVIRO system by 24 zones Nos. 1,88,860.00 1.00
Total 4000 W speaker load, max 500W per zone
20 GPI, 24 GPO and 2 control relays
Up to 20 routers per controller
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
18.3 SITC of Power amplifier, 2x500W 2 ✕ 500 W class-D power amplifier (70/100 V output) Nos. 2,17,686.00 1.00
Low power consumption in standby mode
Excellent sound quality, high signal-to-noise ratio
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Item no. Description Unit Rate Total Qty. Amount
18.4 SITC of Call station Call station with soft touch button for PAVIRO system Nos. 78,156.00 1.00
15 freely programmable buttons
Customization via built-in display and keys
Provision for installing emergency button and key switch
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer
18.5 SITC of Call station extension Call station extension keypad with 20 freely programmable buttons Nos. 46,891.00 1.00
Soft-touch selection buttons
Up to 5 extension keypads can be connected to one call station
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
18.6 SITC of Ceiling loudspeaker 6W, ABS with clamps Nos. 732.00 110.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
18.7 SITC of ABS back box Nos. 592.00 110.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
18.8 SITC of Cabinet loudspeaker, 15W, black High-fidelity music and speech reproduction Nos. 9,288.00 10.00
Selectable 8 ohm, 70 V and 100 V inputs
Compact yet robust ABS enclosure
Supplied with adjustable mounting bracket
Complies with international installation and safety regulations
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
18.9 Supply, Laying and Fixing of 2 Core X 1.5 Sq.mm FRLS Multistrand PVC insulated Copper Mtr. 190.73 1,350.00
armoured BLUE/BLACK cable with all required accessories.
18.10 Supply, Installation, Testing & Commissioning of 17U (600W X 600D)MM floor rack with PDU, Nos. 31,849.03 1.00
Horizontal Cable manager, self, mounting hardware and cooling fan with standard accessories. UL
Certified. Racks should be manufactured by ISO9001:2015, ISO14001:2004 & OHSAS 18001 :
2007, DIN41494 and Equivalent EIA/ISO/EN /CEA Certified company and should have proper EHS
Sub Total 18.....
19 VOICE COMMUNICATION SYSTEM
19.1 Supply, Installation, Testing & Commissioning of IP-PBX System having the following minimum Nos 39,894.04 1.00
specifications: Built-in Facilities: 4 Analog trunk (CO) port and 2 TDM Ports, 50 SIP Extensions,50
SIP IP Subscribers, 8 SIP Trunks, minimum 4 Voice mai Channel, Optional Interfaces: GSM
Module, Power Supply: External power Adaptor - 24V DC, 2.5A.
19.2 Supply, Installation, Testing and Commissioning of SIP-based IP Telephone with PoE support, Nos 8,329.25 31.00
supporting standard SIP protocol, dual Ethernet ports, display (minimum 124 × 64 pixels), minimum
3 programmable feature keys, minimum 4 context-sensitive keys, dedicated volume control keys,
and power support via PoE and 5V DC, 0.6A external power adapter.
Sub Total 19.....
Total Of ELV Items Amount in Rs.
20 MAINTENANCE & OPERATION FOR ELECTRICAL & ELV WORK
Item no. Description Unit Rate Total Qty. Amount
20.1 Provide annual maintenance service (including supply of material) and operation for 3 years after
handing over of work for electrical and ELV works as per schedule including necessary materials to Year
be given under warantee free of cost, etc.
20.2 1st Year ( From the date of Completion of DLP ) Year 5,68,513.41 1.00
20.3 2nd Year ( From the date of Completion of DLP ) Year 5,68,513.41 1.00
20.4 3rd Year ( From the date of Completion of DLP ) Year 5,68,513.41 1.00
20.5 4th Year ( From the date of Completion of DLP ) Year 5,68,513.41 1.00
Sub Total 20.....
(a) General Features & Special Features of the all lift items shall be taken as below.
(b) for Handicap Lifts, Minimum 10 Passengers Lift Capacity shall be considered.same is to be
informed to architect /civil authority to keep necessary size of lift well.
(c) The lifts of 15/ 16 and above passenger capacity shall be taken for Hospital Lifts; Where in
Description “ Stretcher Lifts” shall be mentioned.
(d) The Rates of the following items are for the lift of Machine room less. For Machine room Lifts,
rate for Rs. 1,50,000/- shall be deducted in Total Cost for the Lifts from 4 to 13 Passenger Lift. Rs.
2,00,000/- shall be deducted in Total Cost for the Lifts 15 and above passenger capacity as extra
(e) Add Rs. 80,000/- for the DUPLEX control for the lifts up to 10 floors and add Rs. 10,000/- for
additional each floor above 10 floors.
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting torque Lift 3 phase 440 V A. C.
Permanent Magnet Synchronous motor of proper rating with high efficiency shall be used.[2] Micro
processor based / PLC, ACVVVF, vector control drive with encoder feedback closed loop system
shall be used for lift car and door operation which shall be full collective selective operation hall call
demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase
reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin +
passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade
duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring
shall be of s/s 304 chaker plate design sugeested of engineer in charge. of engineer in charge. Car
doors shall be of stainless steel grade 304, hairline finish with centre opening / telescopic automatic
doors. Car panel will also be S.S. 304 finished with emergency stop device, mechanical door safety
device, facility of auto/ attended mode. All car panel buttons and all floor switches must be with brail
language as per lift act.
Item no. Description Unit Rate Total Qty. Amount
[4] All landing doors must be fire rated for 2 hour shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of 304 with key holes and infrared curtains with
Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car along with alarm switch shall be
provided. Also, Emergency Light & Fan should start immediately without any Time Delay as soon
as power fails.
[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity with
Manual Rescue Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept
open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be provided in control
[14] Mechanical over speed governor with governor calibration as per actual site parameters and
submission of calibration certificate submission, door key holes in the floor doors, fireman switch
shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should
be provided by the lift agency, along with the other steel structure works, foundations for the
[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as /
if directed by engineer in charge.
[17] Permanent wiring with necessary safety devices like RCCB in all circuit, Over Voltage Under
Voltage protection and THD eliminator in circuit for lift machine room and lift well with proper
numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency.
Only 3 phase Power Supply shall be made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without any extra cost. (granite/marble fixing around all
landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents and liaison services for obtaining
all necessary permission from lift inspector and other authorities.
[20] acrylic transparent licence/display A4 size holder in lift car
Item no. Description Unit Rate Total Qty. Amount
[20A] As per statutory requirement of Govt. Of Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift erection and provide report by third party
authorized by concern licensing authority 5.agency has to provide third party insurance upto
completion of free maintenance period and submit the document for the same.
[21] Car Panel Operating Buttons with floor position indicator/buttons must be of Auto Glow type
clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of hairline finish steel grade of
should be provided at appropriate height on the Rear & Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage controlled Stabilizer suitable for your controller, drive and
all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for lift is in scope of work which rating is
sugested by CEICED Department (electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM category
1. Advanced control system dual 64 bit embedded microprocessor with CANBUS Serial
Communication mode including Regenerative power efficient operation,on site programming facility,
Anti nuisance, Pte-opening, BMS/RMS with necessary online real time monitoring system having
necessary connectivity for remote monitoring & other suitable supporting hardware & software
devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration & brail mark with arrival gong and hall lantern &
TFT Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS Moonrock finish / Hair Line / Honeycomb for car
and all Doors, All landing doors must have fire rating up to 2 hours and car door must have multi-
level crisscross beam door protection.
4. To & fro communication system & wiring (i.e. car , control room & guard room ) and Each
elevator are equipped with remote monitoring system.agency has to provide mobile app and user
id and password for monitoring
21.1 DESCRIPTION OF LIFT :
Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift having following main
21.1.1 4/5/6 Passengers, Ground plus 10 upper floors with Rated Speed of 1.5 / 1.75 m/sec., Each 18,96,982.00 RO
(B) With General PLUS ADDITIONAL SPECIAL FEATURES attached herewith. Prem. Cat.
21.1.2 8 / 10 Passengers, Ground plus 2 upper floor with Rated Speed of 1.0 m/sec., Each 14,60,178.00 2.00
(C) With General PLUS ADDITIONAL SPECIAL FEATURES attached herewith. Prem. Cat.
21.1.3 8 / 10 Passengers, Ground plus 10 upper floors with Rated Speed of 2.0 / 2.5 m/sec., Each 23,89,946.00 4.00
(B) With General PLUS ADDITIONAL SPECIAL FEATURES attached herewith. Prem. Cat.
21.2 Additional facilities for lift -
Item no. Description Unit Rate Total Qty. Amount
21.2.1 Supplying & erecting approved make Lift Announcing solid state system in the Passenger/ Each 16,950.00 6.00
Stretcher lifts having AC2/ACVV/ACVF drives & automatic doors only. The system comprising
following features & facilities.
(i) Announcing floor message, message to close period.(ii) Announcing ‘Emergency Message’
when lift is stuck between floors due to power failure or any other reason.
(iii) Instrumental Music between floor announcing.(iv) Announcement in English / Hindi & Gujarati
(v) Flexible to accommodate special per-programmed message such as name of the building
/office.(vi)Volume adjustment control
21.2.2 Providing & erecting approved make overload non-start feature & overload warning Indicator Each 32,205.00 6.00
system in the lift with making use of sound isolated floating platform & micro switches on SI frame
to get sensation of live load inside lift cage at any given moment, with provides new fixtures of
overload warning inside lift cage with new relay in the existing control panel to activate ‘Overload
Non-Start Function with carrying out additional wiring including laying of new travelling cable,
include minor civil work & without changing the existing capacity speed stops, travel & operation of
the desired lift
Sub Total 21.....
22 COMPREHENSIVE MAINTENANCE FOR LIFT WORK
22.1 Provide Comprehensive Maintenance (After Defect Liability Period) Of All LIFTS including all
Electromechnical Items / Spare parts, Material and Labour with all respect During DLP-Free of
22.2 1st Year ( From the date of Completion of DLP ) Year 4,47,127.45 1.00
22.3 2nd Year ( From the date of Completion of DLP ) Year 4,47,127.45 1.00
22.4 3rd Year ( From the date of Completion of DLP ) Year 5,11,002.80 1.00
22.5 4th Year ( From the date of Completion of DLP ) Year 5,74,878.15 1.00
Sub Total 22.....
23.1 Supply, Installation, Testing and Commissioning of 2MP IR Bullet Camera 3.6mm fix Lens with Nos. 6,842.81 16.00
Aperture of F1.6, 1/2.8” image sensor, 0Lux with IR LED ON, Horizontal Field of View: 87 degrees
and IR Range of up to 30 meters, H.265/H.264/MJPEGVideo Compression, Certification: BIS, CE,
FCC, IP67, Support ONVIF S & G, PoE Support, NAS Storage, Triple or higher Stream Support,
True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, Cyber Security
Features: STQC Certified, NDAA Compliant, with require back box.
23.2 Supply, Installation, Testing and Commissioning of 2MP IR Dome Camera 2.8mm fix Lens with Nos. 6,842.81 69.00
Aperture of F1.6, 1/2.8” image sensor, 0Lux with IR LED ON, Horizontal Field of View: 107 degrees
and IR Range of up to 30 meters, H.265/H.264/MJPEGVideo Compression, Certification: BIS, CE,
FCC, RoHS, IK10, IP67, Support ONVIF S & G, PoE Support, NAS Storage, triple or higher Stream
Support, True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, Cyber
Security Features: STQC Certified, NDAA Compliant, with require back box.
Item no. Description Unit Rate Total Qty. Amount
23.3 Supply, Installation, Testing and Commissioning of 64 Channel NVR with 4K Support and 8 HDD Nos. 1,03,872.66 2.00
Slots (support up to 18TB capacity per slot), having 4K HDMI, 1/1 Audio I/O and 2/1 Alarm I/O,
12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 and CIF Recording Resolution, 4x 4K/ 10x 3MP/16x
1080p Local Decoding, Save Storage Space with Adaptive Recording and Camera-wise Recording
Retention, SMS & Email Notification, Video Pop-up, Alarms and Calling from Mobile Application,
Throughput - 512Mbps Uplink, 512Mbps Downlink, ONVIF and Major Camera Brands Support,
Cascading: Create Mutiple NVR Clusters to Monitor and Control Multiple NVRs Centrally, NDAA
23.4 Supply, Installation, Testing and Commissioning of 10 TB Surveillance Hard Disk for 30 days Nos. 66,258.73 12.00
recording at 25 fps on 2 MP resolution
23.5 Supply, Installation, Testing and Commissioning of CCTV management work station Processor: Nos. 2,58,406.23 1.00
i7-12700-12th Gen OS: Windows 11 Pro DEFAULT STORAGE: 512 GB SSD, RAM: 32 GB DDR5,
(16 GB DDR5 - 2 nos), NVIDIA T400 4 GB Quadro graphic card, Additional Storage: 512GB HDD,
KEYBOARD - 1 nos, MOUSE - 1 nos
23.6 Supply, Installation, Testing & Commissioning of 65-inch Professional Grade Display suitable for Nos. 1,22,766.99 2.00
24/7 usage, with minimum 400 nits brightness, 50,000 hours panel life, HD resolution (1920x1080),
20W built-in speakers, Connectivity: 2 x HDMI 2.0 port, 2 x USB port, 1 x 1G Ethernet ports, 10 mtr
Sub Total 23.....
24 NETWORKING SYSTEM
24.1 Supply, Installation, Testing & Commissioning of 15U (550W X 600D)MM Wall mount closed rack Nos. 18,336.91 5.00
with PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with standard
accessories. UL Certified. Racks should be manufactured by ISO9001:2015, ISO14001:2004 &
OHSAS 18001 : 2007, DIN41494 and Equivalent EIA/ISO/EN /CEA Certified company and should
have proper EHS Policy.
24.2 Supply, Installation, Testing & Commissioning of 42U (800W X 1000D)MM floor rack with PDU, Nos. 99,066.32 1.00
Horizontal Cable manager, self, mounting hardware and cooling fan with standard accessories. UL
Certified. Racks should be manufactured by ISO9001:2015, ISO14001:2004 & OHSAS 18001 :
2007, DIN41494 and Equivalent EIA/ISO/EN /CEA Certified company and should have proper EHS
24.3 SITC of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE Sheath [Approved by Competent Mtr. 50.00 445.00
Authority i.e. not Below the rank of Executive Engineer ]
24.4 SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM Nos. 6,833.00 7.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.5 SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m Nos. 1,883.00 14.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.6 SITC of CAT6 UTP 23AWG Solid: Per Meter Mtr. 43.00 6,700.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.7 SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded Nos. 4,357.00 12.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Item no. Description Unit Rate Total Qty. Amount
24.8 SITC of Jack Cat 6 Keystone UTP Nos. 160.00 64.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.9 SITC of Face Plate - Single (Keystone Jack,square) Nos. 90.00 4.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.10 SITC of Face Plate - Dual (Keystone Jack,square) Nos. 100.00 30.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.11 SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less Nos. 155.00 155.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.12 SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' Snag less Nos. 199.00 70.00
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.13 SITC of RJ45 Connector Nos. 39.38 90.00
24.14 SITC of 24 x 10/100/1000BASE-T PoE ports Nos. 31,680.00 10.00
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
L2+ Static Routing
Optional “standard mode” or “surveillance mode” management user interface
193 W PoE budget
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.15 SITC of 24 x 10/100/1000BASE-T ports Mtr. 15,247.00 2.00
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
L2+ Static Routing
Optional “standard mode” or “surveillance mode” management user interface
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.16 Supply, Installation, Testing and Commissioning of 4X4 Dual Band PoE Multi-Gig Wi-Fi 6 Access Nos. 48,842.24 6.00
Point, Management: stand alone or cloud controller, security :WPA3, wall\ceiling mount (Kit
included ), Total users supported: 250, Concurrent Users:75, Including 3 year Cloud controller
24.17 SITC of Maximum distance of up to 10 km Nos. 4,754.00 14.00
Single-mode fiber
1000BASE-LX (IEEE 802.3z standard)
Duplex LC connector
MSA, RoHS-compliant [Approved by Competent Authority i.e. not Below the rank of Executive
24.18 Supply, Laying and Fixing of 25 mm diameter MMS PVC conduit with all required acccessories. Mtr. 86.14 4,400.00
24.19 Supply, laying and fixing of HDPE pipe 25mm Mtr. 114.44 230.00
24.20 Supply, Laying and Fixing of Flexible Pipe White 32 MM Mtr. 78.75 190.00
24.21 Supply, Laying and Fixing of Flexible Pipe White 50 MM Mtr. 142.74 65.00
24.22 Supply, Installation, testing and commissioning of 100 x 50 mm trunking Mtr. 616.48 13.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
AMCFS_Vol_I_Technical_Bid_General_Terms_and_Conditions_Hathijan.pdf
AMCFS_Vol_III_Financial_Bid_Hathijan.pdf
AMCFS-Vol-II-DTS and Drawings_Hathijan-1-1-645.pdf
AMCFS-VOL-II-PART-B-Drawings_Hathijan.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].