Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC AT CHITARPUR SONAR MOHALLA POST CHITARPUR PS RAJRAPPA DIST RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825101 | ₹10.0 L | L1 | Accepted-AOC AWARDED |
| 2 | Rejected-Technical POST CHITARPUR DISTT RAMGARH JHARKHAND 825 101 | CHITARPUR | RAMGARH | JHARKHAND | 825101 | - | - | Rejected-Technical Technically not ok |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not ok |
| Sl No | Description | Qty | Unit | M/S SATENDRA AND COMPANY L1 |
|---|---|---|---|---|
| 1.00 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(2x1.5 Sqmm) | 100 | mtrs | 64 ₹6,400 Lowest |
| 2.00 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required ( 200 mm X 150 mm X 60 mm deep) | 40 | each | 311 ₹12,440 Lowest |
| 3.00 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator (8 way , Double door) | 1 | each | 2,326 ₹2,326 Lowest |
| 4.00 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required (Double Pole) | 2 | each | 610 ₹1,220 Lowest |
| 5.00 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MOB DB complete with connections, testing and commissioning as required (40A) | 1 | each | 400 ₹400 Lowest |
| 6.00 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering (upto 35 Sqmm) | 460 | mtrs | 146 ₹67,160 Lowest |
| 7.00 | Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.(0.3mx0.3mx0.3mx25 Nos +0.3mx0.3mx0.45x32 Nos.) | 1.97 | cum | 297 ₹585.39 Lowest |
| 8.00 | Providing and laying in position cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) in foundation of pump,DG set etc including form work etc as required.(0.3mx0.3mx0.45mx25 | 2.74 | cum | 7,121 ₹19,518.66 Lowest |
| 9.00 | Supplying of GI pipe 50mm dia ( medium class ) | 90 | mtrs | 581 ₹52,290 Lowest |
| 10.00 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 2 core ISI marked with alu. stranded /solid conductor ,armoured 6 sq.mm | 226 | mtrs | 108 ₹24,408 Lowest |
Tender Value
₹9.4 L
EMD Value
₹11,800
Closing Date
17 Mar 2025, 6:00 pmClosed
SO ENM
SO ENM OFFICE RAJRAPPA
Providing/ fixing of different garden light for proper utilization of Community Park in the premises of New D Type and CTS colony under Township of Rajrappa Area
2025_CCL_330701_1
GM(R)/ SO(ENM)/Rjp/24-25/Et/154 dt 06.03.25
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
9 Sept 2026
7 Mar 2025
18 Mar 2025
8 Mar 2025
17 Mar 2025
8 Mar 2025
8 Mar 2025 - 11 Mar 2025
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(2x1.5 Sqmm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required ( 200 mm X 150 mm X 60 mm deep)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator (8 way , Double door)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required (Double Pole)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MOB DB complete with connections, testing and commissioning as required (40A)
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering (upto 35 Sqmm)
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.(0.3mx0.3mx0.3mx25 Nos +0.3mx0.3mx0.45x32 Nos.)
Providing and laying in position cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) in foundation of pump,DG set etc including form work etc as required.(0.3mx0.3mx0.45mx25
Supplying of GI pipe 50mm dia ( medium class )
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 2 core ISI marked with alu. stranded /solid conductor ,armoured 6 sq.mm
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 2 core ISI marked with alu. stranded /solid conductor ,armoured 10 sq.mm
Supplying of 25sq mm 4 core armoured PVC aluminum Cable 650/1100V Grade as per IS7098 (part1) 1988
Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload,short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. (8W 1 m Height )
Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor>0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application.Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS.UL approved MCPCB LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.(LED Post Top Lantern with 35/40 W )
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .