Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance CHAKKALAKKAL H KOTTAT P O | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance THRISSUR KERALA KL | PALAKKAD | KERALA | 678001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.2 L
EMD Value
₹10,574
Closing Date
20 Aug 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Headmistress
Head Mistress GLPS ammadam
Supply and installation of air conditioners to GLPS ammadam
2025_DP_784150_1
HM/GLPS/PRM/25-26/ET1
Open Tender
Electrical Works
Item Rate
90 days
Paralam GP
Please refer Tender documents.
6 documents required · 6 mandatory
₹935
Yes
₹10,574
Yes
22 Aug 2025
12 Aug 2025
22 Aug 2025
12 Aug 2025
20 Aug 2025
12 Aug 2025
Amount
electrical
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
OD68080/2025-2026:Supply, installation and commissioning of single phase, 3 star rating, wall mounting, 1.5 TR, inverter type split air conditioner unit with hermetically sealed compressor, using non CFC refrigerant, conforming to IS1391 part III, suitable for operating on 230 V, 50Hz AC supply, performing cooling, dehumidifying, air circulating, filtering, high energy efficiency, copper condensing coil, silver/white/off white including insulated copper pipe connection and control cable from indoor to outdoor unit and drain pipe up to 3.5 mtrs, cordless remote control etc. with 3 nos free service. Mitsubishi / Daikin / Blue Star or equivalent departmental approved and reputed make having similar properties)
OD68077/2025-2026:Supply and providing Voltage stabilizer (4 KVA) suitable for 1.5 TR split AC unit with input 170 to 270 volts, output 210 to 230 volts, over load cut off, time delay, indicators etc as required (v-guard or reputed equivalent make)
OD68079/2025-2026:Supply and providing heavy duty powder coated wall bracket for mounting out door unit
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
OD68078/2025-2026:Supply and providing 25 mm corrugated PVC flexible conduit as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD68074/2025-2026:Supply and providing 25X6 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required.
OD68081/2025-2026:Supply and providing 12X3 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required.
OD68075/2025-2026:Charges for preparation of application and test report for KSEB connection
BIJU JOSE (BID ID -2297452)
Paulson M I (BID ID -2297485)
Bidder Name
BIJU JOSE
ANAND T THAZHATHA
Paulson M I
stage.html
html • 0.02 MB
finance_1287872.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .