Loading…
Loading…
Tender ID
Tender Value
₹1.2 Cr
EMD Value
₹1.3 L
Closing Date
5 Mar 2026, 12:05 pmClosed
Executive Engineer (R & B) Division, Rajpipla (State)
To Establish IPH Smandated Ayushman Arogya Mandir with Solar Roof Top System at Sc-Khudadi,Ta.Dediapada, Dist Narmada.
280813
43 of 2025-26 (Reinvite)
Open
Civil Works - Buildings
Works
Vadodara
8 documents required · 7 mandatory · 1 optional
₹3,600
Yes
Executive Engineer, Rajpipla (R&B) Division, Rajpipla
₹1.3 L
Yes
25 Feb 2026
25 Feb 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
Name of Work : To establish IPHS mandated Ayushman Arogya Mandir with Solar Roof Top System at Sc-
Khudadi, Ta. Dediapada, Dist Narmada.
BILL OF QUANTITIES
Item Description of Item (with brief specification and reference to book of
Quantity Unit Rate Amount
No. specifications)
1 Excavation for foundation up to 1.50 MT depth including sorting out and stacking of
useful materials and disposing the excavated stuff up to 50 mt lead (A) Loose or soft
2 Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out
and stacking of useful materials and disposing off the excavated stuff upto 50 246.00 Cu.M 139.54
Meter lead. (A) Loose or soft soil
3 Filling in plinth with sand under floors including watering ramming, consolidating and
dressing etc. complete. 11.00 Cu.M 489.28
4 Filling available excavated Earth (Excluding Rock ) in trench plinth side of foundation
etc. in layer not excluding 20 cm in depth consolidation each deposited layer by 379.00 Cu.M 137.47
ramming and watering etc. complete
5 Filling in foundation and plinth with murrum or selected soil in layers of 20cm.
thickness including watering, ramming and consolidating etc. complete. 201.00 Cu.M 304.60
6 Providing and laying cement concrete 1:4:8 (1cement : 4 coarse sand : 8 B.T. stone
aggregates 40 mm. nominal size) and curing complete excluding cost of from work in 40.00 Cu.M 2825.98
:(a) Foundation and plinth
7 Providing and laying controlled cement concrete M150 for curing complete including
cost of formwork but excluding the cost of reinforcement for reinforced concrete
work in (A) Foundations, footings,Base of columns,Plinth Slab and Mass concrete. 57.00 Cu.M 3792.55
8 Providing and laying controlled cement concrete M250 for curing complete including
cost of formwork but excluding the cost of reinforcement for reinforced concrete 53.00 Cu.M 4460.16
work in (A) Foundations, footings,Base of columns and Mass concrete.
9 Providing and laying controlled cement concrete M250 and curing complete including
the cost of form work but excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Column Up to Plinth Level 13.00 Cu.M 7841.64
10 Providing and laying controlled cement concrete M-200 and curing complete
including the cost of form work but excluding the cost of reinforcement for
reinforced concrete work in Columns, pillars, posts and struts up to floor two level 28.00 Cu.M 7802.54
for Columns For All Floors.
11 Providing and laying controlled cement concrete M200 and curing complete including
the cost of form work but excluding the cost of reinforcement for reinforced concrete 36.00 Cu.M 5822.65
work For Plinth Beams
12 Providing and laying controlled cement concrete M200 and curing complete including
the cost of form work but excluding the cost of reinforcement for reinforced concrete 52.00 Cu.M 5791.65
work in BEAMS For All Floor.
13 Providing and laying controlled cement concrete M200 and curing complete including
the cost of form work but excluding the cost of reinforcement for reinforced concrete 61.00 Cum 6492.03
work for Slab All floors
14 Providing and laying controlled cement concrete M-200 and curing complete
including the cost of form work but excluding the cost of reinforcement for 10.00 Cu.M 7451.48
reinforced concrete work For Lintels in All Floors
15 Providing and laying controlled cement concrete M-200 and curing complete
including the cost of form work but excluding the cost of reinforcement for 5.00 Cu.M 6315.53
reinforced concrete work For Chajja in All Floors
16 Providing and laying controlled cement concrete M-200 and curing complete
including the cost of form work but excluding the cost of reinforcement for reinforced 7.00 Cum 8380.98
concrete work in STAIR CASES for All floor
17 Providing TMT bar reinforcement of Fe-500D for R.C.C. work including bending
binding and placing in position complete for All Floor 40090.00 Kg. 77.97
18 Proving & Fixing Chicken mesh for joint between brick work & RCC work fixing with
nail & GI washer as per director in Charge 41.00 Sq.M 74.74
19 Brick Work using Common Burnt Clay Building Bricks having crushing strength not
less than 35 Kg/sm. in super structure Above plinth level up to floor two level in
cement mortar (1:6) ( 1 cement : 6 fine sand) (Conventional) For All Floors
20 Half brick masonry in common brunt clay building bricks having crushing strength
not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in
super structure above plinth up to floor two level Conventional Bricks for All Floors. 300.00 Sq.M 696.90
21 Providing throating or plaster drip and moulding to R.C.C. chhajja by making 5mm to
15 mm wide groove as per design etc. complete 45.00 Rmt 44.07
22 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or
half brick walls for interior plastering upto floor two level and finished even and 1044.00 Sq.M 186.55
smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) All Floors
23 Providing 10mm thick cement plaster (mala troweled finish) in Single coat on
Celling,& Soffits of Stair, concrete wall for interior plastering finished even and
smooth in (ii) cement mortar 1:4 (1 Cement : 4 Sand) For ALL Floors
24 20 mm thick Sand faced Gutka cement plaster with 1x1 cm grooves as suggested by
this office consisting of 12 mm thick backing coat of C.M. 1:3 ( 1 cement : 3 coarse
sand ) and 8 mm thick finishing coat of C.M. 1:1 ( 1 cement : 1 coarse sand) for all 551.00 Sq.M 362.70
heights as directed etc. complete.
25 Providing Water proofing Treatment on Sunk Slab including cement concrete flooring
1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid
in one layer and finished with a floating coat of neat cement average 50mm thick to 105.00 Sq.M 373.70
Prepare slope including water proofing chemical etc. Complete for Sunk Slab All
26 Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm. Length for Sunk
Slab or as directed by Engineer in Charge etc complete. 6.00 No 101.91
27 Applying two coats of Birla or Asian (or equivalent) acrylic lapy ( putty) & two coats
of primer of approved brand and manufacture on new wall surface to give an even
shade including thoroughly brushing the surface free from mortar dropping and other 1685.00 Sq.M 40.59
foreign matter and sand papered smooth.
28 Wall painting (three coats) of plastic paint with one wall highlight in special effect
(royal play) colour, shade and colour of approved brand and manufacture on
undecorated wall surface to give an even shade including throughly brushing the 1044.00 Sq.M 128.38
surface free from mortar droppings and other foreign matter and sand papered
29 Wall painting (two coats) with plastic emulsion paint of approved brand and
manufacture on undecorated wall surface to give an even shade including throughly
brushing the surface free from mortar droppings and other foreign matter and sand 575.00 Sq.M 90.48
papered smooth.+ Extra painting with plastic emulsion paint of pproved brand on
ceilings and sloping roofs.
30 Finishing wall with weather proof exterior emulsion paint on wall surface (two coats)
to give an required shape even shade after thoroughly brushing the surface to
remove all dirt, and remains of loose powdered materials.etc complete 490.00 Sq.M 122.14
31 Providing and fixing 60 x 45 CM Machine cut, free edges, mirror polished Blue Kotah
stone slab flooring 25 mm thick laid on 20 mm thick cement mortar 1:6 ( 1 cement:6
coarse sand) jointed with matching pigment & cement slurry including rubbing and 93.00 Sq.M 1189.78
polishing finishing etc. complete.
32 Providing and fixing 60 x 45 CM Machine cut, free edges Blue Kotah stone slab
flooring 25 mm thick laid on 10 mm thick cement mortar 1:3 ( 1 cement:3 coarse
sand) for Skirting & Riser including jointed with matching pigment & cement slurry 7.00 Sq.M 1205.60
including rubbing and polishing finishing etc. complete.
33 Providing and laying 60 x 60 Cm Soluble salt vitrified Tiles 10 mm thick Tiles in flooring
over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new
surface or fixing on existing flooring by adhesive material including dismentaling of 194.00 Sq.M 1663.47
existing flooring and jointed with color cement slurry including finised with flush
pointing & cleaning the surface etc. complete for light shade
34 Providing and laying Soluble salt vitrified 10 mm thick tile Tiles in skirting, risers of
steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and
pointing in white cement with white cement slurry
35 Providing and laying coloured matt finished Anti skid ceramic tiles of the size 300 mm
x 300 mm in skirting, risers of steps and landing laid on a bed of 12 mm thick cement
mortar 1:3(1-cement:3-coarse sand)finishing with flush pointing in white cement etc. 24.00 Sq.M 1017.30
complete. Colour and Shade approved by Engineer-In-Charge
36 P & L Colour Premium printed Ceramic tiles size 60 x 30 cm 6 mm thick in skirting
risers of steps and dedo on 10 mm thick cement plaster 1:3 (1-cement:3coarse sand) 183.00 Sq.M 1070.50
and jointed with colour cement slurry
37 Providing and fixing machine cut, free edges, pre mirror polished Granite Marble slab
18 mm thick (single piece not less than 150 cm ) for vertical wall/Doors/Windows
Sill,Jams for cladding as per design including full moulded round inside edge and laid
on 10 mm thick cement mortar 1:3 ( 1 cement: 3 coarse sand) jointed with grey 90.00 Sq.M 2425.01
cement slurry including rubbing and polishing finishing etc. complete.
38 Providing and laying water proofing treatment with china mosaic tiles flooring over
avg 50 mm C.C. 1:2:4 bedding for maintaining slope for plain and curve surface &
mm to 20 mm of broken piece not more than 2.5CM of ceramic / glazed tiles ( one
for more colour as directed ) to be laid over cement mortar bedding of C M 1:3 (1
cement : 3 sand ) contain water proofing materials per bag of cement useas specified
by manufactured and slops to be tempered to bring mortar up to surface with using
white cement and colour pigment including rounding of junctions and extending
them up to 15 cm along the wall and curing with bends any patens or design as per
drawing and cleaning by using oxalic acid etc. complete.
39 Providing and fixing Double shutter 35 mm thick solid core wooden Flush Duble
shutter conferming to IS:2202 & ISI approved manufacture finished with 1 mm mm
thick Laminates on both side of shutter, machine Glued PVC beading on Pheriphary,
S.S. Handle and S.S. fixtures & Locaking arrangement of standard make of kitch or 4.00 Sq.M 5907.49
Equivalent, on Each shuuer, Fixed with minimum 4 Nos. 150 mm high S.S. hinges,
sample & shade to be approved by the architect.
40 Providing and fixing Single shutter 35 mm thick solid core wooden Flush Duble shutter
conferming to IS:2202 & ISI approved manufacture finished with 1 mm mm thick
Laminates on both side of shutter, machine Glued PVC beading on Pheriphary, S.S.
Handle and S.S. fixtures & Locaking arrangement of standard make of kitch or 33.00 Sq.M 3594.59
Equivalent, on Each shuuer, Fixed with minimum 4 Nos. 150 mm high S.S. hinges,
sample & shade to be approved by the architect.
41 Providing and fixing FRP Door frame size 100 x 50mm and 35 mm thick FRP Depress
panels Single shutter having extra reinforcement on sides and edges in gel coat finish
the core of shutter and frame is to be filled up with injected fire retardant grade
polyurethane foam done in situ along with embedded wooden pieces for stiffening
and also taking hinges and fixtures the whole FRP Frame and shutter is to be water 12.00 Sq.M 2377.76
proof, whether proof, termite proof and resistance to mild acid / alkali Rates are to
be inclusive of SS hinges with necessary screw and aluminium fixtures and fastening
and fastener sleeve and directed by engineer in change with detailed drawing.
42 Providing and fixing jindal Series E (30 mm) series Two track shutter + one shutter
mosquito net alluminimum window standard extureded colour anodized section with
frame having frame bottom member jindal section no:20737 @ wt. of 0.607 kg/Rmt,
frame side and top member jindal section no.:20738 @ wt. of 0.547 Kg/Rmt ith
sliding shutters of single glass shutter top & bottom member Jindal section no.20993
@ wt.of 0.839 Kg/Rmt, & side member jindal section no. 20549 @ wt. of 0.809 64.00 Sq.M 3143.12
Kg/Rmt & inter lock member jindal section no. 20550 @ wt. of 0.994 Kg/Rmt. with
mm thick transperent plain float glass in shutter including fitting, fixtures, rubber
gasket and transperent silicon seleant as per drawing and instruction of engineer in
43 Providing and fixing standared extruded of alluminium ventilation with 3 mm thick
Bajri figure adjustable tinted louvers Glass fixed to aluminimum strip blade incuding
fixtures, fastenning, labour and equipments as per Detailed Drawing as Directed. 3.00 Sq.M 1124.21
44 Providing and fixing 90 cm high Stainless Steel railing made from anticorrosive
grade S.S. pipe of 50 mm dia (16 gauge) as hand rail with S.S. 304 grade baluster of
mm dia (16 gauge) as a vertical support fixed in RCC slab / steps of stair at 1.2 Mt. c/c
including three horizontal S.S. pipes of 16 mm dia (16 Gauge) at equal distance fixed 20.00 Rmt 2377.54
by 16 mm dia (16 Gauge) S.S. pipe with baluster including accessories as per detailed
drawing as directed etc. complete.
45 Providing erecting and fixing double coated Syntex PVC. (ISI) water tank of required
capacity each with all necessary fittings and connection etc. complete on terrace.
46 Providing, laying and jointing in true line and level 110 diameter U.P.V.C SWR (Type
B) Pipe conforming to IS 13592-1992 with one end plain and other end socketed with
rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size 110 mm diameter x 149 mm 42.00 Rmt 897.79
length x 145 mm height at every 2000 mm centre to centre or shall be concealed in
walls as directed including necessary fittings such as bends, "Y" "T" shoes etc.
including testing of pipes and joints and jointed with adhesive solvent cement
including cost of all materials.
47 Providing, laying and jointing in true line and level U.P.V.C. SWR Type B Pipe
conforming to IS 13592-1992 with one end plain and other end socketed with rubber
ring, & fitting conforming to IS 14735-1999 of approved make for drainage system
pipeline, pipe shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using PVC Clamp of the size 160mm dia x 210 mm length x 196 mm high 42.00 Rmt 834.38
at every 2000 mm centre to centre or shall be concealed in walls as directed including
necessary fittings such as bends, shoes, tees, etc. including testing of pipes and joints
and jointed with adhesive solvent cement including cost of all materials (i) 160 mm
48 Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40)
for cold water including fittings make equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall
be concealed as directed including necessary fittings etc. including testing of pipe and 28.00 Rmt 195.67
joints and fixing the same with adhesive solvent, including cost of all materials.
49 Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40)
for cold water including fittings make equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall
be concealed as directed including necessary fittings etc. including testing of pipe and 14.00 Rmt. 148.12
joints and fixing the same with adhesive solvent, including cost of all materials. 40mm
50 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40)
for cold water including fittings make equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall
be concealed as directed including necessary fittings etc. including testing of pipe and 14.00 Rmt. 91.84
joints and fixing the same with adhesive solvent, including cost of all materials. 25mm
51 Providing and fixing concealed centre point to wall ceiling & floor CPVC (SDR 13.5)
Pipe having National Sanitation Foundation (NSF) seal for potable water of following
dia. Nominal bore tube fitting and clamps including making good the wall, ceiling, and 42.00 Rmt. 253.82
floor, etc. complete 25 mm dia
52 Providing and fixing concealed centre point to wall ceiling & floor CPVC (SDR 13.5)
Pipe having National Sanitation Foundation (NSF) seal for potable water of following
dia. Nominal bore tube fitting and clamps including making good the wall, ceiling, and 64.00 Rmt. 170.36
floor, etc. complete 15 mm dia
53 Providing and fixing Gun metal check or non-return full way wheel valve.(D) 50mm
54 Providing and fixing Gun metal check or non-return full way wheel valve.(E) 40mm
55 Providing and fixing Gun metal check or non-return full way wheel valve.(C) 25mm
56 Providing and fixing ball cock of approved. quality as directed.(A) Copper Metal (ii)
57 Providing and fixing wash down water closet (European W.C. Pan) with integral P or S
trap and PVC dual flush tank with complete fittings including cutting holes in walls
and making good the same connecting the flush bend with cistern and closet etc.
complete including plastic seat cover, water jet and including jointing trap with Waste 6.00 No 3227.96
pipe overall size as per the selection of the Model by E.I.C. or as approved}
58 Providing & fixing of first quality (ii) Flat Back washbasin 550 mm x 400mm size. (i) In
white colour. including with approved sanitary grade material with C.P waste
coupling, waste pipe, 15mm dia Pillar & Stop Cock of approved brand with connection 6.00 No 2147.26
15mm dia flexiable pvc pipe etc. complete
59 Providing and fixing screw down bib taps of following size.(B) Brass chromium plated
screws down Bib Tap. (i) 15mm dia. 10.00 No 186.83
60 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with
jali of the following nominal diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making good the walls. 10.00 No 600.23
61 Providing and fixing S.W. Gully trap with C I grating brick masonry chamber and water
tight C I cover with frame of 300 x 300 mm size (inside) with standard weight 6.00 No 1246.92
(i)square mouth traps (C) 150 mm x 100 mm size P or R type
62 Providing and fixing Jet spray to connect wall mount w.c with 1.5 mtr long plc. heavy
duty supply pipe with two side male female checknut etc. complete. 6.00 No 308.99
63 Providing and fixing 600mm x 450mm Bevelled edge glass mirror of superior glass
mounted on 6mm the A.C. sheet or plywood sheet & fixed to wooden plugs with C.P. 6.00 No 859.41
brass screws and washers.
64 Providing and fixing in position PVC cowel went to pipes.(C) 160mm dia 6.00 No 90.90
65 Providing and fixing in position PVC cowel went to pipes.(B) 110mm dia. 6.00 No 50.50
66 Constructing brick masonry chamber for under ground C.I. Inspection chamber and
bends with bricks having crushing strength not less than 35 Kg/cm2 in cm. 1:5 C.I.
Cover with frame (light duty) 455 mm. X 610 mm. Internal dimensions, Total weight
of cover with frame to be not less than 38 Kgs. weight of cover 23 Kg. and wt. of
frame 15 Kg) R.C.C. top slab with 1:2:4 mix(1 cement : 2 coarse sand : 4 graded stone 30.00 No 3660.76
aggregate 20 mm. size ) foundation concrete 1:5:10 inside plaster 15 mm. thick with
cement mortar 1:3 finished smooth with a floating coat of neat cement on walls &
abed concrete etc. complete.(ii) Inside dimensions, 500 mm. x 700 mm. and 450 mm.
Deep for pipe line with one or two inlets.
67 Applying general insecticide pest control treatment to floors, cupboards etc. including
labour material etc. complete. Using Imidacloprid 30.5 SC As Per IS 6313 part-III
(0.075% Concentration by mass) is recommended 10.5 ml chemical dilute with 5 196.00 Sq.M 43.97
litters of water application 0.5 Litre chemical / Sq.M of surface is recommended as
68 Providing and laying (Two level or slopes) and jointing with stiff mixture or cement
mortar in proportion 1:1, salt glazed stone ware pipes including testing of pipes and
joints etc. complete and Providing and laying Cement concrete 1:5:10 (1-Cement : 5- 16.00 Rmt 531.19
Fine sand :10-Graded stone aggregate 40mm nominal size) bedding for stoneware
pipes (166mm Ave. bed thickness) of following internal diameters with necessary
formwork and curing complete.(B) 150mm dia.
69 Providing and laying (Two level or slopes) and jointing with stiff mixture or cement
mortar in proportion 1:1, salt glazed stone ware pipes including testing of pipes and
joints etc. complete and Providing and laying Cement concrete 1:5:10 (1-Cement : 5- 80.00 Rmt 352.74
Fine sand :10-Graded stone aggregate 40mm nominal size) bedding for stoneware
pipes (166mm Ave. bed thickness) of following internal diameters with necessary
formwork and curing complete.(B) 110mm dia.
70 Providing and laying (to level or slope) and jointing reinforced concrete not pressure
pipes IS class NP 2 of the following internal diameter with collars and nut ends
prepared for collar joints including testing of joints complete 300 mm dia 140.00 Rmt 678.03
71 Providing and laying in trenches jointing in true line and level 50mm dia. U.P.V.C. Pipe
( SCH- 40) for cold water including fittings make equivalent as approved by Engineer
In Charge, including necessary fittings etc. including testing of pipe and joints and 60.00 Rmt 195.67
fixing the same with adhesive solvent, including cost of excavation & refilling the
same with all materials.
72 Providing and fixing Safety Grills of required pattern for windows/door using 16mm x
16 mm square M.S. polished bars, Required at required spacing as per design and
hold fast with coach bolts including one coat of primer and two coats of matt finished 1681.00 Kg. 116.91
oil painting etc. complete.
73 Providing plinth protection to building including excavation in ordinary soil and laying
cement concrete 1:4:8 using stone aggregates of 40mm nominal size in foundation
layer 0.10 mt. thick below pre-cast Rubber Dye inter locking concrete block 60mm
thick with grade of concrete M200 pneumatic compressed by mechanically pressed
and as per approved design including 75mm Sand layer for levelling and filling the
joint with sand in proper line and level etc. complete, Including Providing and fixing 34.00 Sq.M 1313.00
pre-cast concrete kerb stone of grey cement based concrete block 30cm length,30cm
height and 15cm thick of M250 grade concrete as per approved design and including
excavation for fixing in proper line and level, filling the joint with C:M 1:3
(1cement:3fine sand) etc. complete.
74 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block
60mm thick with grade of concrete M300 pnumatic compressed / vibrated
mechanically and as per approved design Confirming to IS 15658 : 2006 including 35 34.00 Sq.mt. 705.95
mm Sand layer for levelling and filling the joint with sand in proper line and level as
per guidlines of IRC : SP 63-2018 etc. Complete.
75 Providing and fixing in position 300 mm high, 150 mm wide English/Gujarati letters
made from 1.0 mm thick stainless steel sheet as directed by Engineer-in-charge with 10.00 Nos. 707.00
all necessary tools & plants etc. complete.
76 Providing and fixing in position 150 mm high, English/ Gujarati letters made from
mm thick stainless steel sheet as directed by Engineer-in-charge with all necessary 10.00 Nos. 404.00
tools & plants etc. complete.
77 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure
poluthene pipes of the following outside Dia. Low densidy, complete with special
falnge compression type fittings, wall clipsetc. including making good the wall ceiling 100.00 Rmt. 339.05
and floor.(G)110 mm
78 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure
poluthene pipes of the following outside Dia. Low densidy, complete with special
falnge compression type fittings, wall clipsetc. including making good the wall ceiling 20.00 Rmt. 515.27
and floor.(G)160 mm
79 Providing junction for rain water juncton chamber of size 0.60x0.60x0.75m with
excavation of size 1.96x1.96 m & 0.15m thick c.c.1:2:4 bed concrete including brick
masonary wall in CM 1:6 of 0.75m height & 0.23m thick with 15mm thick cement
plaster inside & outside & 1.06x1.06 RCC (1:2:4) slab of thickness 0.15m with CRS 10.00 Nos. 7087.17
steel and 0.60mx0.45m cast iron manhole cover with frame weight not less than
kg as per directed by Engineer-in-charge
80 Providing Filter chamber of Brick work in C:M 1:6 of size 2.06mx1.20m x1.20m &
excavation dimension of 2.82mx 1.96x1.35m including C.C 1:2:4 bed concrete of
0.15m thick including brick work in c.m 1:6 for 23cm thick wall including 15mm thick
cement plaster inside & outside with cement slurry & 10cm thick RCC 1:2:4 top cover 10.00 Nos. 14799.53
with frame of minimum weight of 35 kg & filling filter material kapchi in layers (25-
40mm & 10-20mm) & BT metal 40mm & sand as per directed by Engineer-in-charge.
81 Providing Recharging pit of size 2.0m Dia.& 2.0m depth of water logging with
excavation filling the pit with gravel & sand in layers including making 300mm dia
bore depth of 4.5mt & above concrete with kapchi in layers (25-40mm & 10-20mm) & 10.00 Nos. 9456.63
BT metal 40mm & filling brick as directed by Engineer-in-charge.
82 Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out
and stacking of useful materials and disposing off the excavated stuff upto 50 15.00 Cum 153.21
Meter lead. (A) Loose or soft soil
83 Brick work using common burnt clay building bricks having crushing strength not less
than 35 Kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 - 15.00 Cmt 4279.98
fine sand) (B) Conventional.
84 Providing and laying controlled cement concrete M-200 and curing etc. complete
including the cost of form work and excluding the cost of reinforcement etc. 14.00 Cmt 8846.59
complete in RCC wall up to floor two level for Below plinth
85 Providing cement vata (10cm x 10cm size) quarter round in cement mortar 1:1
including neat cement finishing watering etc. Complete 21.00 Cmt 24.28
86 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less
than 35Kg. 1.00 Nos. 958.17
87 Providing & erecting open well horizontal mono block pump set with cast iron body,
complete for three phase submersible motor having [H]For 15 H.P,3 phase open well
horizontal mono block pump set suitable for 1600 LPM to 1025 LPM @ 33 to 42 MTR 2.00 Nos 36107.50
head suitable for 65/80 mm dia delivery pipe
88 20 mm thick Sand faced Gutka cement plaster with 1x1 cm grooves as suggested by
this office consisting of 12 mm thick backing coat of C.M. 1:3 ( 1 cement : 3 coarse
sand ) and 8 mm thick finishing coat of C.M. 1:1 ( 1 cement : 1 coarse sand) for all 58.00 Sqmt 360.57
heights as directed etc. complete.
89 P & L 60x60 cm Machin cut Mirror polished Blue Kota Stone slab 25 mm thick flooring
over 20 mm (average)thick base of cement mortar 1:6 (1-cement 6-coarse sand) or
L.M 1:1.5 (1 Lime putty : 1.5 coarse sand laid over and jointed with grey cement slurry 21.00 Sqmt 1019.39
mixed with pigment to match the shade of slab including rubbing and polishing
90 Distempeing (Two coats) with oil bound distemper of approved brand and
manufacture and Washable of required shade on wall surfaces to give an even shade,
over and including a priming coat with distemper primer of approved brand and
manufacture after thoroughly brushing the surface free from mortar dropping and 111.00 Sqmt 77.30
other foreign matter and also including preparing the surface even and sand papered
91 Distempeing (Two coats) with oil bound distemper of approved brand and
manufacture and Washable of required shade on Celling and sloping roof to give an
even shade, over and including a priming coat with distemper primer of approved
brand and manufacture after thoroughly brushing the surface free from mortar 42.00 Sqmt 85.85
dropping and other foreign matter and also including preparing the surface even and
sand papered smooth.
92 Providing and fixing rolling shutters of approved make made of 80 mm wide M.S laths
inter-locked together through heir entire length and jointed together at the ends by
end locks mounted on specially designed pipe shaft with bracket plates,guide
channels and arrangement for inside and outside locking with push-pull operation 17.00 Sqmt 3784.54
including the cost of hood cover and sprig etc.complete(A) Shutters having width
93 Providing and fixing window having extruded aluminum Colour anodized section
frame main outer size 95mm x 24mm x 1.17mm (of Jindal Section no:2459 @ wt.of
0.738 Kg/mt) horizontal two track member size size 92mm x 31.75mm x 1.50mm (of
Jindal Section no:8933,@ Wt. 1.06 Kg/mt), vertical member of size size 92mm x
31.75mm x 1.50mm (of Jindal Section no:8933,@ Wt. 1.06 Kg/mt)with sliding
shutters of horizontal member size 40mm x 18mm x 1.29mm (of Jindal Section 4.00 Sqmt 2362.39
no:8949 @ wt.of 0.456Kg/mt), vertical member of size 40mm x 18mm x 1.29mm (of
Jindal Section no:8947 @ wt.of 0.456Kg/mt/ Section 8948, @ Wt. 0.457 Kg/mt) with
mm thick transparent bronze colour tinted float glass with powder coated aluminum
fittings and fixtures and transparent silicon sealant glass fixing to frame as per details
etc complete for W2&W3
94 Providing and fixing Mirrar polished 18 mm thick Green Marble stone with full round
edge and polished of approved quality in clading on sill and around the doors/
windows/ ventilation with 20 mm thick cement motor CM (1:3) and fixing with 12.00 Sqmt 1730.13
cement slurry & adhesive including moulding of exposed edges as directed by
engineering in charge etc. complete.
95 Drilling of 200 / 215 mm dia. bore well in over burden rocky or loose collapsible /
boulder strata & lowering of 175 / 200 mm dia. UPVC / PVC / ERW casing pipe above 150.00 Rmt 414.10
12 meters and up to 40 meters depth by DTH rig etc.complete
96 Supplying slotted PVC pipes of approved quality at site of work confirming to IS.
97 Supplying PVC plain pipes of approved quality at site of work confirming to IS.
98 Providing and jointing flat flexible coppered calble PVC insulated enamelled aproved
make three core 2.50mm. 50.00 Rmt. 117.16
99 Supplying submersible pump set suitable for bore of 150 mm dia or more having
phase motor capacity not less than 10 HP with [A] 10 stage 575 to 480 LPM discharge
at 60 to 70 mtr head for 65 mm dia delivery pipe Supplying and erecting push button
operated fully automatic Star-Delta starter with 3 Nos.of 32A. rating contactors and.
1 No. of directly operated thermal overload relay having 20-32A range in sheet steel 2.00 Nos. 54277.40
enclosure for 3 phase 415V. 50 c/s. A.C. motors up to 35 H.P. (A)P.W.Blockwith
necessary connection complete erected onas directed. Cat-II
100 Providing and fixing to concealed wall ceiling and floor galvanized mild floor tubes
(medium grade) of the 50mm nominal bore, tube, fittings and clamps incldg. Making 50.00 Rmt 608.35
good the wall ceiling and floor (F) 40mm dia..
101 Providing and fixing to concealed wall ceiling and floor galvanized mild floor tubes
(medium grade) of the 25mm nominal bore, tube, fittings and clamps incldg. Making 50.00 Rmt 401.95
good the wall ceiling and floor.(C) 25mm dia.
102 Earthwork in cutting including preparing the slope and camber andstacking or utilising
the cutting stuff in bank as directed upto 200 Meters from the end of cutting with all
lead and lift.(i) Hard murrum.+ Add extra over item 9 for conveying and utilising the 27.00 Cum 396.05
stuff in bank from end of cutting with all required lead and lift.(C) Above 400 Meters
upto 500 Meters
103 Supplying, installation, testing and commissioning of electric driven Main Fire Pump
suitable for automatic operation and consisting of following, complete in all respects,
as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron
body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS
1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed
RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 1.00 Nos 357335.01
protection for enclosure, horizontal foot mounted type with Class-'F' insulation,
conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling
guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation
duly plastered with anti vibration pads.
1.1 2280 lpm at 88 m Hea
104 Providing laying,testing & commissioning of 'C' class heavy duty MS Pipe conforming
to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nut
bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support 5.00 Rmt 3059.10
frame and painting with two or more coats of synthetic enamel paint of required
shade complete as required:150mm
105 Providing laying,testing & commissioning of 'C' class heavy duty MS Pipe conforming
to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nut
bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support 15.00 Rmt 1134.42
frame and painting with two or more coats of synthetic enamel paint of required
shade complete as required:50 mm dia
106 Providing laying,testing & commissioning of 'C' class heavy duty MS Pipe conforming
to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nut
bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support 15.00 Rmt 915.29
frame and painting with two or more coats of synthetic enamel paint of required
shade complete as required:40 mm dia.
107 Providing laying,testing & commissioning of 'C' class heavy duty MS Pipe conforming
to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nut
bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support 15.00 Rmt 658.43
frame and painting with two or more coats of synthetic enamel paint of required
shade complete as required:25 mm dia.
108 Supplying,fixing,testing & commissioning of double flanged sluice valve of rating PN
1.6 with non rising spindle,bronze/gun metal seat,ISI marked complete with
nuts,bolts,washers,gaskets and conforming to IS 780 of following sizes as 1.00 Nos 20157.12
109 Supplying,fixing,testing & commissioning of butterfly valve of PN 1.6 rating with
bonze/gunmetal seat duly ISI marked complete with nuts,bolts,washers,gasket 1.00 nos 5904.43
conforming to IS 13095 of following sizes as required:100 mm dia.
110 Supplying,fixing,testing & commissioning of butterfly valve of PN 1.6 rating with
bonze/gunmetal seat duly ISI marked complete with nuts,bolts,washers,gasket 1.00 nos 4412.14
conforming to IS 13095 of following sizes as required:80 mm dia.
111 Supplying,fixing,testing & commissioning of butterfly valve of PN 1.6 rating with
bonze/gunmetal seat duly ISI marked complete with nuts,bolts,washers,gasket 1.00 nos 3350.59
conforming to IS 13095 of following sizes as required:50 mm dia.
112 Providing,installation,testing and commissioning of non return valve of following sizes
conforming to IS:5312 complete with rubber gasket,Gi bolts,nuts,washers etc.as 1.00 nos 15750.74
required:150 mm dia.
113 Providing,installation,testing and commissioning of non return valve of following sizes
conforming to IS:5312 complete with rubber gasket,Gi bolts,nuts,washers etc.as 1.00 nos 9785.64
required:100 mm dia.
114 Providing,installation,testing and commissioning of non return valve of following sizes
conforming to IS:5312 complete with rubber gasket,Gi bolts,nuts,washers etc.as 2.00 nos 5127.87
required:50 mm dia.
115 Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve
with necessary fittings. Size: 25 mm 2.00 Nos 2373.50
116 Supply, Installation, Testing and Commissioning of 100 mm dia Pressure Gauge (for
all pipes) of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of
stainless steel 310 in cast aluminium, stove enameled, black, weather proof
case with outer, screwed aluminium bezel and complete with necessary U-type 1.00 Nos 2777.50
stainless steel siphon tube and cock including providing suitably painted angle iron
support to the tube etc.as per required.
117 Providing & fixing of pressure switch in M.S pipe line including connection etc. As
required. 1.00 nos 3383.50
118 Supply, and fixing First Aid Hose Reel with MS construction spray painted with P.O
red,conforming to IS 884 complete with the following as required.
20mm nominal internal dia water hose thermoplastic(textile reinforced) type-2 as per
IS 12585 20mm nominal internal dia gun 2.00 Nos 7682.67
metal globe valve and nozzle. drum and brackets for fixing the equipment on the
wall.Connection from riser with 25mm dia stop gun metal valve & MS pipe and
119 Providing, fixing, testing & commissioning of installation control valve of cast iron
body, brass/bronze working parts comprising of water motor alarm, bronze seat
clapper, clapper arm and hydraulically driven mechanical gong bell to sound
continuous alarm when the wet riser/sprinkler system activates, pressure gauges, 1.00 Nos 42686.67
emergency releases, strainer, pressure switch, cock valve complete with drain valve
and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice
plate, gasket etc of follwing sizes as required : 150 mm Dia
120 Providing,fixing,testing & commissioning of 15mm dia quartzoid bulb type sprinklers
of rating 68 degree centigrade with required accessories:Pendent sprinkler 8.00 Nos 462.22
121 Providing,fixing,testing & commissioning of 15mm dia quartzoid bulb type sprinklers
of rating 68 degree centigrade with required accessories:Horizontal side wall sprinkler 8.00 Nos 546.68
122 Providing,fixing,testing & commissioning of 15mm dia quartzoid bulb type sprinklers
of rating 68 degree centigrade with required accessories:Concealed sprinkler 8.00 Nos 1270.50
123 Providing, fixing photo luminescent Signage's as per IS standard in Block / Small
Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes:For Fire 100.00 Sq.inch 9.09
Extinguisher,exit,do not to do,etc.
124 Supply, installation, testing and commissioning of ABC type 6 kg confirm to
IS:15683, with ISI marked / TAC approved fitted with required accessories 2.00 Nos 2626.00
including wall suspension brackets.
125 FIRE EXTINGUISHER
Supply, installation, testing and commissioning of Carbon Dioxide (CO2) type Fire
Extinguisher of 4.5 kg confirm to IS:15683, with ISI marked / TAC approved fitted 2.00 Nos 7575.00
with required accessories including wall suspension brackets.
126 Supply, installation, testing and commissioning of Modular ABC type 5 kg confirm
to IS:15683, with ISI marked / TAC approved fitted with required accessories 2.00 Nos 2525.00
including wall suspension brackets.
127 Submitting the application to obtain Fire Plan Approval and After Completion of Work
Obtain Final Fire NOC for 3 Year 1.00 Nos 186850.00
128 Pay Legal Fees to Concern Authority for Obtaining Plan Approval and Final NOC 350.00 SQ.mtr 15.15
129 Demolition including stacking of serviceable materilas and disposal of unserviceable
materials with all lead and lift. (i) R.C.C. work 58.00 Cumt 1108.12
130 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up
to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell
push & accessories and earth continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered with 54.00 Pt. 485.81
textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f) with
medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete.Cat-III
131 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of
.ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch and hum free
EME step type electronic fan regulator mounted and accessories with earth
continuity of following type erected on PVC / Metallic/Wooden box, single mounting 21.00 Pt. 674.68
base frame covered with textured/metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as
directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete.Cat-III
132 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected with following type of 18.00 Pt. 510.05
accessories.[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board.(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete.Cat-III
133 [II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db
board.(f) with medium class Rigid PVC pipe and accessories erected concealed in 15.00 Pt. 745.38
wall/ceiling complete.Cat-III
134 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic/Wooden box, single mounting base frame covered with
textured / metallic/white front plate modules erected on / in wall / ceiling with 27.00 Pt. 257.55
following type accessories. Cat-III
135 (a) Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary connections as per site 2.00 No. 160.59
situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone Socket [A] For
One Gang.Cat-III
(b) (4) TV Co-axial Socket outlet cat-III 2.00 No. 160.59
( c) (7) Blank Plate Single cat-III 10.00 No. 25.25
(d) (8) Computer RJ-45 socket Cat-III 4.00 No. 160.59
( e) (10) 6/16Amp. Universal socket Cat-III 9.00 No. 199.98
(f) (14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole Modular MCB Switch Cat-III 9.00 No 410.06
136 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in 180.00 Mtr 33.33
approved manner as directed (b) 25 mm
137 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated 544.00 Mtr. 82.82
stranded wire of green colour for earth continuity of following size.(A) with medium
class Rigid PVC pipe and accessories.(b) 2 wire 2.5 sq. mm
138 (a) providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green 180.00 Mtr. 112.11
colour for earth continuity of following size.(A) with medium class Rigid PVC pipe and
accessories.(a) 2 wire 4 sq. mm
(b) h) 4 wire 6 sq. mm 230.00 Mtr. 260.58
139 providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required size of copper lugs, 15.00 Mtr. 142.41
nuts and bolts if required.(g) One wire 16.00 sq. mm
140 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI
marked copper wires of following size to be erected as directed.(h) 2.50 Sq.mm 3 50.00 Mtr 77.77
core round PVC sheathed.
141 Providing & Erecting approved make following size of TV Co-axial flexible cable
comprising inner conductor of solid bare copper insulated with Foam PE & Secondary
conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage 60.00 Mtr 62.62
overall sheathed with black PVC insulation.(e) RG-11
142 (a) Supplying & erecting approved make Telephone Cable electrolytic copper conductor
PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT
erected in existing pipe. of following size of conductors & nos.of pairs. With necessary
connections.[A] Conductor Size 0.5 mm (a) Unarmoured (2) Two Pairs
(b) (6) Twenty Pairs 20.00 Mtr 127.26
143 Supplying & erecting approved make LAN cable of following size in existing pipe as
per direction.[C] CAT-
144 Providing & erecting main Distribution (MDF) indoor type, back mounted frame as
per DoT standard approved with krone strips(b) Suitable for 20 pair 1.00 No 1368.55
145 Providing & erecting Switch board for Computer or electric apparatus consisting of
following modular type accessories mounted with PVC / Metallic concealed/open
box with single mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories.Cat-III
146 Decorative call bell Ting-tong box type 250 volts complete erected 4.00 Nos. 71.71
147 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy>
85 lumens/watt ,LED LED driver efficiency > 85 %( fitting required LM-79 & LM-80 54.00 Nos. 535.30
Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges
shown.) (A) Tube Light with integral driver (v) 40 Watts, Surge-2 KV, IP-20,
conventional 4 feet Cat-III
148 Supplying and erecting led lamps with following wattage capacity of 220 to
voltage, minimum 15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp 12.00 No. 112.11
holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable LAMP holder
(ii) 5 to 8 watts Cat-III
149 Supplying and erecting LED street light / Flood light fittings with High power White
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED 9.00 No 4997.48
driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply
with over-voltage protection. (ii) above 48 to 60 Watts Cat-III
150 Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. 1.00 Nos. 6173.12
with all internal connections, spreader tinned copper & complete erected in existing
16 G.M.S. housing. ICS=100% of ICU only Cat III
151 Supplying & erecting approved make Four Pole 415V change over switch interior for
panel mounting with operating mechanism A.C.23 duty confirming to IS for ©100A / 1.00 Nos. 7790.13
152 Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper
Busbars with four equal Nos. of electrolyte bus having current density not more than
1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current carrying capacity, erected Rn
with necessary bus bar supports /insulators, main cable socket to each bar, erected in Mtr.
existing cubical panel with necessary connections.(A) Suitable for 100 Amp. Capacity
153 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in 48.00 Nos. 112.11
existing box. confirming to IS 8828/1996 with ISI Mark Cat-III
154 providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and
having breaking capacity 10 KA to be erected in existing box. confirming to IS 9.00 Nos. 270.68
8828/1996 with ISI Mark Cat-III
155 Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having
10KA breaking capacity & confirms to IS :8828 in existing box having following 5.00 Nos. 638.32
capacity.(b)40 Amp. Cat-III
156 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve)
having 10KA breaking capacity & confirms to IS :8828 in existing box having following 1.00 Nos. 737.30
capacity.(C)63 Amp.Cat-III
157 Providing and erecting Sheet Steel powder coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to
IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable for(B) three phase 4.00 Nos. 2339.16
incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b)
sheet steel double door.(i)4 way
158 providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping 12.00 Nos. 2235.13
with all advance feature & do not incorporate any electronic component. for
following Max. rating erected as directed.(ii) 40Amps. DP.Cat-III
159 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 30.00 Kg. 794.87
160 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia.
galvanised iron pipe with coupling and buch buried in specially prepared earth pit 8.00 Nos. 368.65
complete with necessary 8 SWG earth wire.
161 For using salt and charcoal / coke as required for pipe type earthing. 8.00 Nos. 171.70
162 Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make
Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made
of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising,
connection terminal dia of 14 mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover (A)(approved make OEM has to
submit test certificate including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the value of earthing
resistane mentioned in test Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.[A] For electrical installation up
to 440 VLength of Pipe - 1 Mtr Back filling compound - 1 Nos. of Bag of 15 Kgs.
163 Providing & erecting weather proof, dust & vermin proof, floor mounted front
operated indoor type cubical panel board necessary IP-42 and above protection as
per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for
outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with
necessary accesories , supporting angles/ flats channel including cutting, bending,
drilling, welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS,
suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & 0.50 Sq. mtr. 10468.65
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessary ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder coating. (The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters,
Fuses etc. The dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size..(A) locally
fabricated panel board (i) with 350 mm depth
164 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in 220.00 Mtr. 126.25
existing trench / pipe of following size of cables (b) 4 core 6 Sq. mm
165 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / 90.00 Mtr. 153.52
pipe of following size of cables (a) 4 core 16 Sq. mm
166 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / 120.00 Mtr. 190.89
pipe of following size of cables.(A) 4 core 25 Sq. mm
167 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating
the fault all over the run and back filling the same and making the surface as normal 230.00 Mtr. 55.55
168 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across
the road crossing or on floor with necessary material in an approved manner and 15.00 Mtr 397.94
making the ground as per original.(B) 400 mm dia.
169 Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of
same material at required depth in existing trench for laying of cable. below ground 240.00 Mtr. 62.62
/ road surface for enclosing cable .(A)50 mm outer dia.
170 (a) Providing and, fixing heavy duty flange type brass cable gland with rubber ring for
PVC insulated armoured cable complete with out going tails, insulating tape etc for 16.00 Nos. 38.38
following size of cables.(b) 2 to 4 core 6 Sq. mm
(b) 2 to 4 core 16 Sq. mm 2.00 Nos. 47.47
(c ) (D) 2 to 4 core 25 Sq. mm 2.00 Nos. 51.51
171 (a) Solder less crimping type Aluminium lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner.(A) 1.5/
172 Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark
with condenser A.C.230V 50c/s. 1400 mm. sweep complete, canopy erected on
existing hook or clamp with earthing [ Make shall be approved by Engineer in Charge]
173 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod
erected duly painted for fan complete with proper insulation without leakage and 21.00 Mtr. 108.07
174 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC
bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy
Duty PVC box complete erected concealed in Ceiling with necessary finishing. 21.00 Nos. 108.07
175 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
176 Supplying & erecting single phase approved make industrial exhaust fan suitable for
medium duty ring mounted low noise operation suitable for medium duty having
following dia size and maximum speed in RPM [A] 305 mm dia 900 RPM Cat.II
177 Providing suitable M.S. louver shutter of the Exhaust fan. 6.00 Nos. 368.65
178 Providing recess in wall or window frame suitable for erection of Exhaust fan
complete with plastering and colour washing to match the colour of the wall or
window complete with expanded metal in order to render the fitting in accessible and
the room water-proof.
179 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The
pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box consist
of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail
for MCB Mounting, stud type terminal and arrangement for cable termination to be
erected With Suitable foundation (Included) as per details given by manufacturer
considering site requirement.(C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia,
mm thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and 600mm
long J-Bolt.Approx Pole weight 46 kg
180 Providing and erecting street light pole bracket comprising main B Class GI pipe of
cm/require outside dia. complete with suitable B Class G.I sleeve tubing of approx.
45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with
suitable rise as per site condition & suitable welded stiffener reducer and nipple with
check nut complete painted with one coat of Red oxide / PU base primer and two
coats of Aluminium / PU paint. paint with following nos of arms. [A] Single Arm
181 Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity
40 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should
drop by 15˚ C within a hour, The water cooler should be comprising of hermetically
sealed compressor, fan motor, condensing unit, water tank surrounded by 1.00 Nos. 49559.69
evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet
connection. The body of water cooler will be made from Stainless Steel.
182 Supplying & erecting 5 stage single reverse osmosis water purification system with
M.S. powder coated frame, prefilter housing with 'O' ring presediment filter GAC
filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline
type post carbon filter auto low & high pressure switches with following size of 1.00 Nos. 29187.99
storage tank & LPH capacity & erected as directed [C] 50 Ltr / Hr with 150 psi 2 nos
183 Supplying and erecting approved make Single phase power conditioners suitable for
input voltage 180V / 280V, output voltage 220V (+ / - 10%) AC 50 ‘Hz with electronic
relays & component of housed in sheet metal cabinet ‘with epoxy powder coated, 1.00 Nos. 3232.00
with high - low cut-off, time delay, voltmeter, selector switch, 5/15 A universal socket
with range off (iv) 4 KVA
184 Supplying and erecting approved make panel mounting type Digital Voltmeter having
3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all 1.00 Nos. 1275.63
connection, wiring etc .with manufacturers calibration certificate.
185 Supplying and erecting approved make panel mounting type Digital Ammeter having
3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to
operate on 500 Volt AC , erected on existing panel board with all connection, wiring 1.00 Nos. 1558.43
etc .with manufacturers calibration certificate.
186 Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply
500 V on existing panel board with necessary connections. 2.00 Nos. 317.14
187 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio
15 VA burden erected in existing CRCA box duly secured with insulating materials 1.00 Nos. 274.72
connected to the meter
188 Supplying and erecting approved make suitable panel indicator LED type lamp, lens
cover, complete erected with necessary connections. 3.00 Nos. 43.43
189 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar
Power Plant with Solar Panels (ALMM approved): Frame Material : Anodized
Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-
Iron Tempered Glass (AR Coated), High efficency and positive power tolerance Pmax:
0/+5, Module Efficiency should be approx. 19.5%-22%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 & MC4 Compatible and
Enclosed with Bypass diodes, 100% Electroluminescence test to ensure error free
Modules, Thep. temp. co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to be used. Unit
Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product
warranty and 25 year Linear Power Warranty includes all mechanical and electrical
parameters of the Solar panel. Modules must be complied to the DCR(Domestic 8.00 KW 44081.45
content requirements). The Ration of AC to DC is 5:6 for the Installation capacity
which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% - 98.9%,
O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P
THDi: <3%, Operating Tempreture Range: -25~60°C, Integrated protection of Inverter
are Anti-islanding Protection, Input Reverse Polarity Protection, Insulation Resistor
Detection, Ground fault protection, Residual Current Monitoring Unit, Output Over
Current Protection, Output Short Circuit Protection, Output Over Voltage Protection,
PV array string fault Protection. Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection
Integrated, Residual Current Monitoring Unit Integrated, Output Over Current
Protection Integrated, Output Short Circuit Protection Integrated, Output Over
Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD &
APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: The
mounting (Rectangular pipe / square pipe / circular pipe) with requisite cross bars,
nuts and bolts, etc. shall be Hot deep galvanized with minimum 80micron coating.
The Rectangular / square /circular hollow pipe section used for the structure should
have a minimum thickness of 2.0 mm. other than above, the material thickness
should be minimum 2.5 mm. A certificate of a structural engineer certifying the 0.00 0.00
strength and stability of the mounting structure to withstand the weight and wind
speed of 150 km/hour throughout the life span of 25 years of the system, shall be
submitted by the vendors. Hot Dipped Galvanized steel coils. suitable arrangement
for base plate for foundation , solar panel mounting, the structure should be suitable
for carry the load of solar panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for
installtion of stucture should be (SS 304) quality.The ground clearance of the bottom
most edge of solar panel shall not be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balane of
System with necessary Swichgears (Suitabel size and protection of ACDB & DCDB),
inter connecting wiring, earthing system as per the CEIG drawing approval, lightining
arrester system as per the CEIG drawing approval, all liasoning work with various gov.
dipartment like state nodal agency,DISCOM & CEIG is included in agency scope
(Excluding All charges namely GEDA Application fees, Solar connectivity Charges,
Meter connectivity Charges, Meter testing Charges and system stability/strenthning
(B) Grid Tied Solar Power System: 7 - 10 kW (3 - phase) 0.00 0.00
In Word : One Crore Twenty Four Lakh Fifty-Four Thousand Two Hundred Eighty Rupees and Nighty-Eight Paise.
I/We am/are willing to carry out the work at… % above/below percent(Should be written in figures and words) of the estimated rate mentioned
* Estimated Amount * Estimated Amount
put to tender put to tender
Deduct :…………% Below Add :………%Above
In Words …………………………………… In Words………………………………
* (Please strike out whichever is not applicable).
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra
payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C
Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost of difference of cement
consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
5 The amount of dismentalled credit materials at Rs. 86862.00 shall be deducted from first R.A. Bill.
6 The Contractor will have to submit the mix design for different grades his own cost befor execution as directed and to be approved From the
Engineer In Charge.
Dy. Executive Engineer Executive Engineer
Const.(R&B) sub Division Rajpipla (R&B) Division
Rajpipla Rajpipla
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 Vol 1 SBD Book.pdf
3 VOL 03 SBD Book.pdf
2 VOL 2 Specification index.pdf
6 BOQ.pdf
4 Building Booklet.pdf
5 GRs SBD with Index.pdf
7 All Plan IPHS Building.pdf
Condition for Nominated Contractor E2.pdf
Contractor Registration Paripatra.pdf
ELECTRICAL GR.PDF
Electrical Item Make List.pdf
Liability period GR.pdf
Memorandum of Understanding.pdf
SOLAR CONDITION.pdf
STANDARD BIDDING DOCUMENT PROCUREMENT OF ELECTRICAL WORK.pdf
aYUSHMAN MANDIR E Tender Notice.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .