| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹39.5 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹40.7 L+₹1.2 L (3.06%)Rejected-Finance VILL DEPOPARA BINNAGURI PO BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹42.6 L+₹3.1 L (7.94%)Rejected-Finance DEPOPARA PO BINNAGURI PS BANARHAT DIST JALPAIGURI WEST BENGAL PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹43.0 L+₹3.5 L (8.99%)Rejected-Finance MINISTRY OF DEFENCE MES JALPAIGURI WEST BENGAL | BANKURA | WEST BENGAL | 713142 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹43.7 L+₹4.2 L (10.7%)Rejected-Finance | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
PERIODICAL SERVICES (INTERNAL AND EXTERNAL) INCLUDING REPAIR TO PLASTERING FACIA/CHAJJA REPAIR ETC IN MARRIED ACCOMMODATION AT NON MAP QTRS IN NORTH ZONE UNDER GE (NORTH) BINNAGURI
2024_MES_661132_2
8701 / 12 / 2024-25 /07 / E8
Open Tender
Civil Works
Item Rate
270 days
BINNAGURI CANTONMENT
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹80,000
Yes
22 Oct 2024
3 Sept 2024
20 Sept 2024
3 Sept 2024
18 Sept 2024
11 Sept 2024
Amount
M&L for preparation of old surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and distempering walls by applying one coat of acrylic based distemper emulsion of any tint/shade with roller including wall putty / white cement wherever required to fill the wall cracks/holes complete all as specified and as directed.
M&L for complete removal of existing treatment of old decorated treatment on wall / ceiling / chajjas and applying waterproof cement based putty of average thickness 1 mm and sand papering surfaces to achieve smooth surfaces over surface on wall / ceiling / chajjas after preparation of surface and applying two coats of distemper acrylic emulsion of approved tint over a coat of alkaline resistant primer with roller including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for preparation of old surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and distempering walls by applying two coats of acrylic based distemper emulsion of any tint/shade with roller including wall putty / white cement wherever required to fill the wall cracks/holes complete all as specified and as directed.
M&L for preparation of old treated surface of ceiling by brooming down or steel wire brushing; scrapping down smoke root, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash / colour wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for preparation of old treated surface of walls by brooming down or steel wire brushing; scrapping down smoke root, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash / colour wash on old decorated surfaces of wall including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for preparation of old treated steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamelled paint including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for preparation of old treated wood or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for obliterating old writing of any description, not exc 0.1 sqm with paint to match existing works complete all as specified and as directed.
M&L for rewriting/repainting to existing writing letters or figures not exc 30 cm height in block Roman, Italian or Indian letters including stops, comma, arrows, brackets, dashes etc on sign board (Black or yellow base) including two coats of oil paint over a coat white base synthetic enamel paint complete all as specified and as directed.
Taking down cement plaster on brick work of any description including racking out joints and cleaning dust etc including removing rubbish material complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface finished even and fair without using extra cement complete all as specified and as directed.
M&L for applying average 15mm thick plaster in two coats (10+5mm) with ready-mix pre-packed proportioned dry mix mortar, blended with PP fibres, mixed with liquid water proofing compound @200ml per bag of cement or as per manufacturer's instruction on top layer on fair faces of brick wall or concrete surfaces additives on external surfaces including transporting of material, mixing, curing, scaffolding etc including finished even and fair without using extra cement complete all as specified and as directed. Note : Liquid water proofing compound will be measured and paid separately as supply only.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick walls or concrete surfaces in two coats (10mm + 5mm) in mixed with water proofing compound @200ml per bag of cement on top layer or as per manufacturer instructions on top layer finished even & fair without using extra cement complete all as specified and as directed. Note : Liquid water proofing compound will be measured and paid separately as supply only.
Supply only liquid water proofing compound etc complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even and fair without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash/ colour wash including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for waterproof cement based putty of average thickness 1 mm and sand papering surfaces to achieve smooth surfaces over new plastered surface on wall / ceiling / chajjas after preparation of surface and applying two coats of distemper acrylic emulsion of approved tint over a coat of alkaline resistant primer with roller including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
M&L for preparation of new plastered surfaces on wall / ceiling / chajjas and obtain smooth surface and applying Two or more coats of premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Ltre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new/old surfaces as per the manufacturer instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coats of colour/white wash to match the colour of existing adjecent surface complete all as specified and as directed.
M&L for complete removal of existing treatment of old decorated treatment on wall / ceiling / chajjas by scrapping with true care wall sander to make the surface free from dust, loose paints etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and obtain smooth surface and applying two or more coats of premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Ltre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over surfaces as per the manufacturer instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.
M&L for dismantling/demolition of edge of RCC fins, parapets of any size and making good with CM 1:3 and provided drip course 25mm x 10mm deep with CM 1:3 at edges of RCC slab/Chajjas etc complete all as specified and as directed.
M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets, bed block, copings, filling concrete, gaps in between glazed & fly proof steel window, cills, railing up to 60 cm in height in roof kerbs or mud stops, rounded or chamfered on edges, padding to roof etc including necessary form work as required complete all as specified and as directed. Notes:- Notes for All Painting and Weather Proofing Painting Items:- The following precautionary measures shall be ensured by the contractor before and during execution of the work :- (i) All the painting works and weather proofing works shall be got executed through original material manufacturing company or their authorised applicator as approved by GE and contractor should submit MOU with the manufacturing company or their authorised applicator before execution of work and entire work shall be executed with the approved firm. (ii) Contractor shall deposit entire qty of materials (Proprietary material) in sealed containers required for painting works covered under subject contract in the custody of Engr-in-charge/ office-in-charge of unit. (iii) The material as required shall be issued to contractor by JE / Engr-in-charge on daily basis and the empty container / bags shall be deposited in the store of Engr-in-charge by the contractor, for verification as per standard consumption/ coverage prescribed by the manufactures, (iv) After completion of the painting works contractor shall remove and clean all the droplets / stain of paint left on the glass floor, glass and joinery.
M/S D S CONSTRUCTION CO (BID ID -3098693)
M/S MOHAN KUMAR BANSAL (BID ID -3097519)
AYAN DAS (BID ID -3096444)
SHIVAAY CONSTRUCTIONS (BID ID -3097511)
SHRI ARABINDA GHOSH (BID ID -3096504)
MESSRS SEN BROTHERS (BID ID -3097572)
SHRI MANOIRANJAN BISWAS (BID ID -3097535)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .