Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | ₹27.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹28.8 L+₹1.3 L (4.79%)Rejected-Finance | ₹28.8 L+₹1.3 L (4.79%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical L3 |
Tender Value
₹29.1 L
EMD Value
₹50,000
Closing Date
19 Apr 2023, 5:15 pmClosed
Executive Engineer Thrissur corporation
Executive Engineer Thrissur corporation
PW2-24306/23Estimate for HT works at Sky Walk at Sakthan Nagar, Thrissur.
2023_LSGD_571208_6
PW4-13558/23
Open Tender
Electrical Works
Item Rate
180 days
Superintending Engineer Thrissur corporation
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹50,000
7 Jun 2024
12 Apr 2023
22 Apr 2023
12 Apr 2023
19 Apr 2023
12 Apr 2023
12 Apr 2023 - 17 Apr 2023
Amount
Supply, installation, testing and commissioning of one number total unitised substaton at site includingnleading the same to the place of erection UNITISED SUBSTATION 160KVA CAPACITY type 11000/433 V, 3 phase AN cooled Vector DYN-11 Cast Resin copper wound Transformer with OFF Circuit tapping of +-5% to -10% in steps of 2.5, changeable by tap links provided, HV terminals connectedto 11 KV 26.3 KA, 630A Load Break Switch with Earth Switch. The AB SFU should have provision for XLPE Cable connection and should have suitable rating HT HRC Fuses, and Output of the AB SFU connected to 11KV Seal Off Bushing of transformer. Transformer should have temperature sensing device with trip contacts and unitised substaton sa a whole should have all standard accessories including emergency trip push button station for HT SFU as per rules and practices. Including shifting the transformer from the point of unloading to the transformer room. Also including charges for preparation of drawings applications submitting to Electrical Deparment and Electrical Inspectorate and obtaing sanction and energising the installation etc complete. ( Including all civil work for Transformer plinth )
Supply and fitting 11KV TOD meter including necessary testing at TMR along with CT PT unit. ( make L&T)
Supply at site and providing indoor end termination of 3 x 300 sq.mm XLPE cable to the transformer (USS) including all materials required for firm joints as per standards.
Supply and providing efficient plate earthing using 1200mm x 1200mm x 12.5 mm CI plate earth electrode conforming to IS 3043 complete with necessary earth pit chamber. C.I cover, GI pipe, connections including filling the pit with charcoal and salt, including excavation, refilling and all connected civil works (for Transformer)
Supply at site and Labour charges for Laying / fixing , giving end termination of the following copper strips and copper wire for effective earthing of the system as per IS 3043, Copper strips of size 25 x 3 mm
Copper wire SWG 10 (3.14 mm )
Design fabrication, supply, installation, erection testing and commissioning of MCCB panel cubicle type fully compartmentalised dust tight, vermin proof L.T. Switch boards fabricated out of 1.626 mm thickness CRCA sheet for panel boards, powder coated as per standards and having appropriate rating busbars & earth bus and of approved shade. The busbars should be of suitably rated TPN Aluminium having the specified normal and short circuit capacities and should be insulated with heat shrinkable colour coded PVC sleeves and supported by DMC/SMC pillar/finger type busbar supports. Design and fabrication of the switch boards should be as per standards of State electrical inspectorate, K.S.E.B, and Bureau of Indian standards. The board shall be completed with earth bus of adequate capacity and double earth connection to all switches. Internal rigid connection etc. complete with hinged doors, name plates, heavy duty rubber gaskets, removable gland plates. Aluminium anodised Danger Notice Board of size 150 x 100 mm (Cable entry according to site conditions). Incoming side: 400A 4P MCCB (50KA) with all accessories - 1set, 400/5A CT's with MFM, Indicator lamps with 2A MCB controls. Out going: 250A TPN MCCB (35KA) with all accessories - 1 set, 125A TPN MCCB (35KA) with all accessories - 1set
Design fabrication, supply, installation, erection testing and commissioning of MSB cubicle type fully compartmentalised dust tight, vermin proof L.T. Switch boards fabricated out of 1.626 mm thickness CRCA sheet for panel boards, powder coated as per standards and having appropriate rating busbars & earth bus and of approved shade. The busbars should be of suitably rated TPN Aluminium having the specified normal and short circuit capacities and should be insulated with heat shrinkable colour coded PVC sleeves and supported by DMC/SMC pillar/finger type busbar supports. Design and fabrication of the switch boards should be as per standards of State electrical inspectorate, K.S.E.B, and Bureau of Indian standards. The board shall be completed with earth bus of adequate capacity and double earth connection to all switches. Internal rigid connection etc. complete with hinged doors, name plates, heavy duty rubber gaskets, removable gland plates. Aluminium anodised Danger Notice Board of size 150 x 100 mm (Cable entry according to site conditions). Incoming side: RYB indicator - 1set, MFM with 3nos CTs -1 set., 250A TPN SFU with suitable HRC - 1no, 400A TPN SFU with suitable HRC - 1 no, 400A 4P ATS with relay and control wiring ( make Hager / L&T ) , Out going :160 A TPN MCCB (35KA) with all accessories - 2 set., 125 A TPN MCCB (35KA) with all accessories - 3 set.
Design fabrication, supply, installation, erection testing and commissioning of SSB cubicle type fully compartmentalised dust tight, vermin proof L.T. Switch boards fabricated out of 1.626 mm thickness CRCA sheet for panel boards, powder coated as per standards and having appropriate rating busbars & earth bus and of approved shade. The busbars should be of suitably rated TPN Aluminium having the specified normal and short circuit capacities and should be insulated with heat shrinkable colour coded PVC sleeves and supported by DMC/SMC pillar/finger type busbar supports. Design and fabrication of the switch boards should be as per standards of State electrical inspectorate, K.S.E.B, and Bureau of Indian standards. The board shall be completed with earth bus of adequate capacity and double earth connection to all switches. Internal rigid connection etc. complete with hinged doors, name plates, heavy duty rubber gaskets, removable gland plates. Aluminium anodised Danger Notice Board of size 150 x 100 mm (Cable entry according to site conditions). Incoming side: RYB indicator - 1set, 200 A TPN Isolator - 1 No, TPN Busbar as per ISS, Out going :100 A TPN MCCB (35KA) with all accessories - 1 set., 63 A TPN MCCB (35KA) with all accessories - 5 set.
Supply, erection, testing and commissioning of Power Factor Correction panel comprising of Incomer 160A TP MCCB- 1No., APFC relay, indication lamps 3 Nos, Multifunctional D/M meter, CT, control fuses 2KVAR capacitor - 1 No., 3KVAR capacitor - 1 No., 5KVAR capacitor - 2 Nos, 7.5KVAR capacitor - 2 Nos, 10KVAR capacitor - 1 No., 20KVAR capacitor - 1 No. with,10A 2 way toggle switches ON-OFF push button, AC3 capacitor duty contractors with MCB's for each capacitors and control wiring complete with suitable busbar etc. as per standards in a free-standing, floor mounting cubicle type.
Supply and installation of 63A 30mA 4P RCCB and 63A 4P MCB with necessary weather proof sintex box for AC unit.
Supply & Erection of vertical / horizontal type M.S cable trays and cable supports fabricated out of M.S. angles(ISA) and M.S flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with 2 coats of Zinc chromate primer 2 coats of enamel paint. The design of the cable trays and details shall be got approved by the electrical consultant/ client
Supply and Labour charges for laying, testing and commissioning of the following Aluminium H.T/ L.T. UG. Cables (AYWY / AYFY / A2XFY) through cable trays, wall, including supply and fixing of clamps, nuts & bolts, identification tags route markers etc. required for clamping intervals as necessary. 3x 300 sq.mm XLPE, 11KV, HT UG cable
3.5x185 Sq mm
3.5x150 Sq mm
3.5x 95 sq mm
3.5x70 Sq mm
4x 25 sq mm
4 core 2.5 sq. mm copper armoured cable
2 core 2.5 sq. mm copper armoured cable
Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11kV/ 1.1kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 3x 300 sq.mm XLPE, 11KV, HT UG cable
4x 25 sq mm
Supply of all materials and terminations of the following ( AYWY or AYFY or A2XFY) Aluminium L.T. U.G.cables using simple compression type cadmium plated brass cable glands, suitable crimped Type cable lugs, cable identifications tags and including gland earthing using copper conductor of adequate size,- Cu strip for termination of cables etc.3.5x185 Sq mm
3.5x150 Sq mm
3.5x 95 sq mm
3.5x70 Sq mm
4x 25 sq mm
4 core 2.5 sq. mm copper armoured cable
2 core 2.5 sq. mm copper armoured cable
Suppy and installation of LT/ HT sign boards
Supply and Installation of cable route Marker HT/ LT
Biju E.M
Essjay Electrolinks (P) Ltd
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_843971.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .