| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical DUE TO SHORTFALL OF REQUISTE DOCUMENTS |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
7 Jan 2025, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF RO PLANT OF 500 LITRES HR PERMEATE CAPACITY ALONG WITH CLEANING IN PLACE SYSTEM CIP AND 50 LPH LAB Q POLISHING UNIT ULTRA PURE WATER UNIT ALONG WITH ALLIED WORKS FOR DTL AT GOVERNME
2024_PWDJK_267461_1
MHDJ/e-NIT 168 of 2024-25
Open Tender
Repair and Maintenance Services
Turn-key
45 days
Ayurvedic College Hospital Akhnoor Jammu.
as per e nit
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹39,000
15 Feb 2025
9 Dec 2024
8 Jan 2025
9 Dec 2024
7 Jan 2025
13 Dec 2024
9 Dec 2024 - 19 Dec 2024
Amount
Providing & Fitting of RO System with FRP constructed MGF, ACF with complete pipeline UPVC and from high pressure pump, reject SS304 RO 500 LPH permeate capacity along with all allied accessories as well as shed work to accommodate the instruments and Equipments of the whole plant as per scope of work in TECHNICAL SPECIFICATION/ SCOPE OF WORK at serial no. 1
Providing & Fitting of LAB-Q POLISHING UNIT (ULTRANPURE WATER UNIT) i.e Lab-Q Ultra a multipurpose water maker which produces Type 1 ultrapure water and Type 2 pure water simultaneously and the produced water has very low Total Organic Carbon (TOC) content, meeting the requirements of liquid chromatography and all spectroscopy methods, besides microbiological and molecular biology applications. It also meets ISO 3696, Type 1 standards. Dispensing of ultrapure water is configured on the front panel whereas pure water is dispensed from the storage tank. For feed water with higher level of TDS i.e. > 20 ppm a customized pretreatment module can be designed prior to Lab-Q Ultra. Features• Online resistivity meter - displays product water quality for continuous monitoring • Automatic Flush Device (AFD) - ensures periodic cleaning of the system • Integrated recirculation system - ensures consistent water quality & reduces TOC to low levels (2-5 ppb) • Dry run protection - ensures protection of the pump when the inlet water is unavailable • Instant water dispensing with single touch user interface • Produces Type 2 and Type 1 water from a single integrated unit to meet varied laboratory applications • Option of 30- & 60-liter reservoir to meet daily usage • Easy dispensing with one touch user interface • High purity storage tank - a built-in UV, protective air filter and high-grade tank material ensures sustained purity while in storage Product Water Specifications: Flow rate 10 LPH -50LPH Conductivity <0.1 μS/cm Resistivity 10 MΩ.cm Total Organic Carbon (TOC) <5 ppb * Endotoxin Level NA <0.25 Eu/ml Particle > 0.22 μm NA < 1 per ml Bacteria NA <1cfu/ml
Providing & Fitting of Auto Electrical panel for RO PLANT and LAB Q Polishing Unit along with other allied accessories/instruments as given under: Pressure Gauges 7Nos. (MOC-SS 316),Make– H-Guru, Baumer or any other equivalent make Rota meters 3Nos.(MOC of wetted parts SS 316) Make-Aster, Flow Star or any other equivalent make Conductivity Meter 1No. Make-Danfoss or any other equivalent make Pressure Switch LPS&HPS 2No. Make-Aster or any other equivalent make pH Meter 1No. Make-Aster or any other equivalent make MOC of Panel MS PANEL Relay Based or any other equivalent Switch Gear L&T or any other equivalent make Cables Enter Bottom Panel accessories Complete Cabling, Auto flushing, HPP Cut-Off LPS, HPS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .