Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | ₹36.8 L | L1 | Accepted-AOC Agreement executed on 03.03.2026 |
| Sl No | Description | Qty | Unit | ARDEN INFRATECH PRIVATE LIMITED L1 |
|---|---|---|---|---|
| 1.00Appendix A | ||||
| 1.00 | 12.8.1.C:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M20 - Using Concrete Mixer - (Without formwork) | 11 | cum | 9,083 ₹99,913 |
| 1.00 | 12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications | 1.21 | MT | 1,02,597 ₹1.2 L |
| 1.00 | 16.18:Replacement of Damaged Concrete Railing. | 100 | RM | 649 ₹64,900 |
| 1.00 | 16.22:Repair of RCC Railing : Carrying out repair of RCC m30 railing to bring it to the original shape. | 100 | metre | 214 ₹21,400 |
| 1.00 | 14.6:Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. | 150 | RM | 2,756 ₹4.1 L |
| 1.01 | OD59479/2025-2026:Providing and applying 2 coats of water based cement paint to un plastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying
paint @ of 1 litre for 2 sqm. | 1,654 | sqm | 275 ₹4.5 L |
| 1.01 | OD59841/2025-2026:Chipping and spalling / defective concrete and exposing the defective/ corroded reinforcement of the ceiling ,join the additional bar wherever 1/3 diameter of the barr is corroded.Removal of the defective concrete across the bar should be at least 2mm beyond the defective bar so that the reinforcing bar can be cleaned with emery ribbon , wire brush etc.After cleaning the bar wash the bar wash with clean water and collected spalled / fallen concrete .Measurement is calculated for whole exposed area.Including cost of materials,labour charges ,conveyance of materials to site hire charges of tools etc. complete | 95.6 | sqm | 1,152 ₹1.1 L |
| 1.01 | OD59816/2025-2026:Anti Corrosive treatment to Steel: Providing & applying inhibition coats/system to exposed reinforcement bars & also new bars, after cleaning & removing scales and rust completely as specified in 1.4, Two component inhibitor Nitozinc Primer std. of Fosroc or MasterEmaco P130 of BASF or equivalent having specific gravity of 1.75 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40 microns DFT per coat as approved by Engineer-in-charge and/or Consultant shall be used as per manufacturer?s specification in two coats at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, necessary surface preparation and necessary protection after and during work. The concrete surface area contianing the rebars where the treatment is carried out shall be considered for measurement. | 95.6 | sqm | 797 ₹76,193.20 |
| 1.01 | OD59838/2025-2026:Polymer Modified Mortar (Pre-Packed): Providing and Applying single component,high strength, fibre reinforced, thixotropic cementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1 day and 45 MPa at 28 days and capable of applying upto 50mm thick in single layer such as Renderoc SP40 of Fosroc or Master Emaco S 348 of BASF or equivalent, to the prepared concrete area for thickness up to 50mm, after applying epoxy resin based bonding coat as per manufacturer specification, before the bonding agent becomes tack free, initially by hand and finally finishing the same with trowel carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface on the columns, slabs, beam etc. at all heights, where the thickness of application is less than 50 mm in patches as per specification . Item rate is inclusive of all material including the bond coat, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete and as directed by Engineer-in-charge and/or consultant. | 95.6 | sqm | 4,706 ₹4.5 L |
Tender Value
₹33.9 L
EMD Value
₹50,000
Closing Date
5 Feb 2026, 4:00 pmClosed
Ex Engineer Bridges Division kannur
Office of the Ex Engineer PWD Bridge Division Kannur
Bridge safety estimate for various Bridges under Bridge section Payynnur-1
2026_PWD_825845_2
PWD/BR/TR/10769/2025_5_1_1/1
Open Tender
Civil Works - Bridges
180 days
Payyannur
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
Yes
₹50,000
Yes
7 Mar 2026
28 Jan 2026
7 Feb 2026
28 Jan 2026
5 Feb 2026
28 Jan 2026
Appendix A
12.8.1.C:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M20 - Using Concrete Mixer - (Without formwork)
12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications
16.18:Replacement of Damaged Concrete Railing.
16.22:Repair of RCC Railing : Carrying out repair of RCC m30 railing to bring it to the original shape.
14.6:Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
OD59479/2025-2026:Providing and applying 2 coats of water based cement paint to un plastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.
OD59841/2025-2026:Chipping and spalling / defective concrete and exposing the defective/ corroded reinforcement of the ceiling ,join the additional bar wherever 1/3 diameter of the barr is corroded.Removal of the defective concrete across the bar should be at least 2mm beyond the defective bar so that the reinforcing bar can be cleaned with emery ribbon , wire brush etc.After cleaning the bar wash the bar wash with clean water and collected spalled / fallen concrete .Measurement is calculated for whole exposed area.Including cost of materials,labour charges ,conveyance of materials to site hire charges of tools etc. complete
OD59816/2025-2026:Anti Corrosive treatment to Steel: Providing & applying inhibition coats/system to exposed reinforcement bars & also new bars, after cleaning & removing scales and rust completely as specified in 1.4, Two component inhibitor Nitozinc Primer std. of Fosroc or MasterEmaco P130 of BASF or equivalent having specific gravity of 1.75 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40 microns DFT per coat as approved by Engineer-in-charge and/or Consultant shall be used as per manufacturer?s specification in two coats at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, necessary surface preparation and necessary protection after and during work. The concrete surface area contianing the rebars where the treatment is carried out shall be considered for measurement.
OD59838/2025-2026:Polymer Modified Mortar (Pre-Packed): Providing and Applying single component,high strength, fibre reinforced, thixotropic cementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1 day and 45 MPa at 28 days and capable of applying upto 50mm thick in single layer such as Renderoc SP40 of Fosroc or Master Emaco S 348 of BASF or equivalent, to the prepared concrete area for thickness up to 50mm, after applying epoxy resin based bonding coat as per manufacturer specification, before the bonding agent becomes tack free, initially by hand and finally finishing the same with trowel carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface on the columns, slabs, beam etc. at all heights, where the thickness of application is less than 50 mm in patches as per specification . Item rate is inclusive of all material including the bond coat, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete and as directed by Engineer-in-charge and/or consultant.
OD58189/2025-2026:Applying anticorrosive agent two component Zera zinc ZR or equivalent product to the existing and new bars after clearing them etc as per technical specification
OD59845/2025-2026:12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil - Depth upto 3m - Mechanical Means
12.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
12.8.A.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15
55.16:Providing and fixing guard post Providing and fixing guard post of size 200mmx200mm, 1400mm long, 800mm above ground level and 600mm below GL. casted in M20 Grade concrete reinforced with 4 nos of 8mm dia longitudinal bars and 6mm dia stirrups @ 100mm c/c, firmly fixed in position by means of foundation of size 0.5mx0.5mx0.7m in M15 grade concrete below ground level including painting 2 coats on exposed surface with synthetic enamel paint in alternate white & black band 20cm wide
55.14:Providing and fixing retro-reflectorised ceramic tilesProviding and fixing retro-reflectorised ceramic tiles of size 10cmX20cm using High Intensity Micro Prismatic (Type IV) grade sheeting with 7 years warranty fixed over Ist quality ceramic glazed tiles including cost of glue, cutting charges, fixing with suitable adhisive on concrete or other surface etc complete.
55.10.1:Providing and erecting retro-reflectorised Object Hazard Marker 300mm x 900mm Providing and erecting retro-reflectorised Object Hazard Marker sign with 07 years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick / aluminium composit material sheeting 4 mm thick with suitable back support frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly fixed 30cm above ground level by means of properly designed foundation with M 15 grade cement concrete 30cmx30x45cm, 45cm below ground level including painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as per approved drawing and clause 801.300 mm x 900 mm
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1396916.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1396916.xls
BOQ • 0.31 MB
TenderDocument.pdf
Tender Documents • 1.63 MB
TenderNotice.pdf
Other Document • 0.03 MB
Download all tender documents and submit your bid