| 1 | L1₹8.8 CrAccepted-AOC F 31 INDUSTRIAL AREA PHASE VIII SAS NAGAR MOHALI 160071 | S A S NAGAR | PUNJAB | 160071 | ₹8.8 Cr | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹9.0 Cr+₹13.3 L (1.51%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹9.0 Cr+₹13.3 L (1.51%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹10.4 Cr+₹1.6 Cr (17.8%)Rejected-Finance | ₹10.4 Cr+₹1.6 Cr (17.8%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹10.9 Cr+₹2.1 Cr (23.8%)Rejected-Finance | ₹10.9 Cr+₹2.1 Cr (23.8%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹15.0 Cr+₹6.2 Cr (69.8%)Rejected-Finance NOT SPECIFIED | ₹15.0 Cr+₹6.2 Cr (69.8%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹7.3 Cr
EMD Value
₹6.9 L
Closing Date
20 Jul 2022, 6:00 pmClosed
HQ CEJZ Jodhpur
HQ CEJZ Jodhpur
PROVN OF SEWAGE TREATMENT PLANT OF APPROX CAPACITY 2 MLD AND ALLIED INFRA AT JAMNAGAR MIL STN (JOB NO.009/AMWP/12C/2019-20)
2022_MES_520652_1
800509/JAM/E8 of 2022-23
Open Tender
Civil Works
Lump-sum
750 days
Jamnagar
As per tender documents
9 documents required · 9 mandatory
₹3,000
GE (A) Jamnagar
₹6.9 L
Yes
31 Mar 2023
28 Apr 2022
22 Jul 2022
28 Apr 2022
20 Jul 2022
17 Jun 2022
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 27(R)
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTHWORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 30
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 31
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATIONS" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 34
Lump sum price worked out by the contractor for "ROAD & PATH" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 36(R)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 38(R)
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 39(R)
Lump sum price worked out by the contractor for "COMPOUND WALL & GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 41
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 46
Lump sum price worked out by the contractor for "DEMOLITION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 47
Sch 'A' PART-XI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
INTERNAL ELECTRIFICATION S&F surface / wall mounted LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S&F surface / wall mounted LED batten capable of delivering 1150 lumen, having PC diffuser, luminous efficacy of > 110 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S&F 25 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, wall mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible copper conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed.
ROAD & PATH M & L 150 mm thick (compacted thickness) WMM in two layers each of 75 mm thick (each layer to be rolled and consolidated separately) confirming to the grading given in table 400-13 & physical requirement given in table 400-12 spread by mechnically means & rolled by using 8-10 ton vibrator power rolled over compacted surface of soling as specified in clause 406.3.5 of MORT&H specification complete all as specified and directed.
SEWAGE DISPOSAL M&L for DWCPE pipe 200 mm nominal dia of class SN4 complete laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring and tested complete all as specified in IS 16098:2013 complete all as specified and as directed.
M&L for DWCPE pipe 300 mm nominal dia of class SN4 complete laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring and tested complete all as specified in IS 16098:2013 complete all as specified and as directed.
M&L for DWCPE pipe 400 mm nominal dia of class SN4 complete laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring and tested complete all as specified in IS 16098:2013 complete all as specified and as directed.
NOTE FOR ITEM NO 16.00 TO 18.00:- (i) Inner & outer dia shall be as per IS code. (ii) Stiffness class of the pipe shall be of SN4.
Supply and laying SFRC Manhole cover complete all as specified.
Supply, laying, connecting, jointing and testing ductile iron pressure pipe of size 200 mm dia, ISI marked to IS-8329-2000 Reaffirmed Edition 4.1 suitable for "push on joints" in standard working lengths supplied with rubber gasket duly ISI marked for water supply, Class K-7 with socket and with cement mortar lining inside the metalic zinc coating with finishing layer of bituminious paint on outside the pipe without polythelene sleeves but including "push on joints" supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (Reaffirmed-2003) with dual hardness of type 2 (bulb) and type-5 (Heel) quality laid in tenches complete all as specified & directed.
SEWAGE TREATMENT PLANT (PRIMARY TREATMENT) Supply, Installing, testing and commissioning (SITC) of sewage treatment plant based on principle of aerobic attached growth non clogging randomly moving bed bio reactor (MBBR) with primary, secondary and tertiary process domestic sewage treatment plant having capacity 100 m3/day, along with interconnecting equipment, lot of piping, valves, instrumentations, pumping and blower equipment and setting up of in-plant laboratory for physical, chemical and bacteriological analysis inclusive of all instrument / equipment glassware, testing chemicals and culture, testing tables and furniture, manuals, register, logbooks etc., including all civil work for sewage treatment plant such as foundation platform, plinth etc. comprising following accessories / equipment as per the OEM specification and attached drawing to achieve the indicated parameters mentioned elsewhere in the tender documents complete all as specified and directed.
S&F of overflow type oil skimmer with flow of 0-0.15 LPH with belt size 150 mm and motor rating 0.5 HP complete all as specified and directed.
(SECONDARY TREATMENT) Submersible, non-clogging, Equalized waste Water Transfer Pump having having 5 m3/hr at 12 MWC head, continuous duty rating, cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with induction motor 415 V, 3- Phase, 50 Hz of suitable capacity with 2900 RPM, IP 58 protection, class F insulation including installation, foundation as per OEM specification, electrical connection, with suitable rating of copper cables, starter panel with complete protection device such as over load current protection, phase reversal, single phasing, no voltage / over voltage protection, complete accessories such as voltmeter, Ammeter, LED indicators etc. all complete as specified in technical / particulars specification (1 W + 1 S)
Package MSEP 100 KLD STP- tank of size 9.23 m X 2.2 m X 2.2 m having twin lobe rotary Air Blowers (1 W + 1 S) capable of delivering 55 m3/hr of atmospheric air at 5.5 kg/cm2 pressure, driven through "V" belt or directly coupled through flexible coupling to a TEFC motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply.
Air piping (100 mm NB) comprising of pipes droppers / laterals with MS (epoxy coated) header complete with all fittings viz. tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc. -
Sodium Hypochlorite dosing system consisting of one HDPE tank of 100 litres capacity, positive displacement diphragm dosing pump having variable flowrate of 0-6 LPH along with motor suitable for operation at 230 V, 1- Ph, 50 Hz. supply and complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall have speed & stroke control.
(TERTIARY TREATMENT) Centrifugal Filter Feed Water Pump (FFP) capable of 5 m3/hr discharge at 20 MWC head having solid handling capacity of minimum 5 mm size particles CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. (1 W+ 1 S)
MSEP vessel for pressure sand filter of ø 1000 mm & 1500 mm HOS (shell & dishend thickness 4.0 mm minimum) suitable for test pressure of 5.0 kg/cm² and working pressure of 3.5 kg/cm², including media (pebbles, sand, silex, fine sand, fine silex), standard fittings viz. pressure gauge, sampling cock, backwash including frontal piping & valves, etc.
MSEP vessel for Activated Carbon Filter (ACF) of ø 1000 mm & 1500 mm HOS (shell & dishend thickness 4.0 mm minimum) suitable for test pressure of 5.0 kg/cm² and working pressure of 3.5 kg/cm², including media (activated carbon with supporting media), standard fittings viz. pressure gauge, sampling cock, backwash including frontal piping & valves, etc. - 01 NOS.
SLUDGE DEWATERING SYSTEM S&F Non clogging type centrifugal Sludge Transfer Pumps (P3) capable of 3.13 m3/hr discharge at 10 MWC head having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. (1 W + 1 S)
S&F Filter press feed pumps capable of 3.13 m3/hr discharge at 10 MWC head with all accessories. (1 W + 1 S)
S&F Filter press as of size 36" x 36" x 35" for 2 MLD as per following specification
(i) Type - plate and frame (ii) Plate - poly propelene (iii) Frame - mild steel (iv) Filter cloth - suitable size (v) Fluid handled - sludge (vi) Nature of solids - Biological (vii) Sludge quantity - 41 Kg/Batch (viii) Sludge concentration - 1%
Supply, installation, commissioning and testing of factory made, CPRI Approved type tested, indoor, cubical compartmental type " CONTROL PANEL" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed including the followings:-
The MCC shall comprise of the following: [a] Busbar Chamber: [i] Copper busbar of rated capacity 100 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) [b] Incoming: [i] 63 A, 415 V, Ics = Icu =16 kA, 50 Hz, FP MCCB with adjustable overload settings, adjustable short-circuit settings, adjustabble neutral protection, adjustable earth- fault settings, instanteneous protection and microprocessor based trip unit- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. [c] Outgoing: [i] 20 A, 10 kA, 415 V, 50 Hz FP MCB (C- curve) 20 Nos.
Equalized Waste Water Transfer Pump (1 HP)
Air Blower (2 HP)
Sludge Recirculation Pump (1 HP)
Filter Feed Pump (1.5 HP)
Dosing Pump (1 HP )
Anoxic Agitator( 1 HP)
M & L for STP piping of SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed.
100 mm NB - MSEP pipe
80 mm NB- MSEP pipe
65 mm NB- PVC
M & L for ISI marked 1.1 kV grade aluminium conductor of size 2 core, 1.5 sqmm, XLPE insulated armoured cables, conforming to IS: 7098 (Part 1)- 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST- 2 outer sheath conforming to IS: 5831- 1984, including clamping and termination complete as specified and directed.
EXTERNAL ELECTRIFICATION Supply, installation, testing and commissioning of CPRI approved load-break/fault-make switch with TAG type HT HRC fuse, fuse trip mechanism, earth switch with interlock with the main drive mechanism, shunt trip coil (220 V, 50 Hz, AC) and electrical standard indications, conforming to IS 9920/ IEC 62271-2002 and having the following specifications for outdoor floor mounted installation as specified and directed having following features:-
[i] Type of Break: Air Break [ii] Rated Voltage: 12 kV [iii] Rated Frequency: 50 Hz [iv] Rated Current: 630 A [v] Rated Peak Current: 85 kA [vi] Rated Short time Current: 31.5 kA (for 1 sec.) [vii] Rated Making Current: 80 kA [viii] Rated breaking Current: 630 A [ix] Impulse Voltage wave shape 1.2/50 µs: To Earth: 75 kV; Between Poles: 75 kV; Between Open Contacts: 85 kV
[x] Power Frequency Test Voltage: To Earth: 35 kV; Between Poles: 35 kV; Between Open Contacts: 45 kV [xi] Breaking of Capacitive Load: 50 A [xii] Closed Loop Breaking Current cos φ = 0.31 MD [xiii] Rated Transformer Off Load Breaking Capacity = 120 A [xiv] Rated Line Charging Breaking Capacity: 90 A [xv] No. of Poles: 3 [xvi] No. of Breaks per Pole: Single [xvii] Degree of Protection: IP 65
S&F 45 W LED street-light having pressure die-cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection, including necessary electrical connections to the fitting with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer all as specified and directed.
S&F weather- proof PVC junction box of size 250 mm x 200 mm x 100 mm, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos. of polymide gland with check nut (M-32- 3 Nos.) fixed on poles with flat aluminium clamps of size 20 mm x 3 mm, nuts, bolts, washers, etc. complete all as specified and as directed.
Supply, installation, testing and commissioning of intelligent street light control (ATSC) suitable for 6 kW maximum load, wall/pole mounted, having built-in networking support, built-in astronomical timer, 32 A TP contactor, 40 A TPN MCB housed in 3.15 mm thick powder CRCA sheet housing all complete as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to and including earth lead of galvanized strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50 mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20 mm bore GI pipe medium grade watering pipe, lugs, 40 mm bore GI pipe medium grade protection pipe up to 7.5 m. NOTE:- Item includes the cost of earth lead and GI protection pipe up to 7.5 m. GI strip and protection pipe beyond 7.5 m shall be measured and paid for separately.
M&L for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
DG SET Supply, installation, testing and commissioning of silent DG Set, 100 kVA conforming to IS: 10002- 1981, complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS: 13364- 1992, mounted on a common base frame & coupled through a flexible coupling or close coupled and AMF Panel complete with platform, control panel having meters, sound-proof canopy, etc. of capacity 100 KVA complete all as specified and directed having following features:-
[a] Engine: 4/6 cylinder, in-line, 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator, air to air aftercooling, optimised turbocharger for increased altitude,Inline fuel pump with A1 class mechanical governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, battery charging alternator with 1 x 12 V DC battery. [b] Alternator: Brushless type, screen protected, revolving field, self-excited alternator, conforming to IS/IEC 60034-1 3-phase reconnectable winding with 12 terminals brought out for connection, dedicated winding specially designed for single operation, impregnation on all wound components for better mechanical strength [c] Control Panel: Manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts: [i] Controller: Aluminum bus bars with suitable capacity with incoming/outgoing terminals [ii] Indicating lamps for ‘Load ON’ and ‘Set Running’ [iii] Instrument fuses duly wired and ferruled [iv] MCCB of suitable rating with overload and short circuit protections
TREATED WATER SUPPLY Supplying and laying UPVC pipes of pressure rating 10 kgf/cm2 with all fittings complete all as specified and directed for following dia of pipes:-
150 mm dia
100 mm dia
80 mm dia
Supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with Bronze wedge ring on both side, gland packing, class - PN 1.6 with flanged ends drilled suitable for bore of pipe 80 mm ISI marked (IS:14846:2000) having S.S. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed.
Supply, installation, testing and commissioning (SITC) of Treated water pump 10 BHP capable of 54 m3 / hr discharge at 20 MWC head having capacity of minimum 5 mm size particles CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. complete all as specified and directed by engineer-in-charge. (1 W+ 1 S)
Supply, installation, testing and commissioning (SITC) of Treated water pump 3 BHP capable of 40 m3 / hr discharge at 5 MWC head having capacity of minimum 5 mm size particles CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. complete all as specified and directed.(1W+1S)
M&L for Construction of brick Masonary valve chamber of size 600 X600 X 600 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , one brick thick walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in CM (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 50 mm X 50 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M & L for Construction of Stand post for water filling in tanks consisting of RCC M-25 footing and column with appropriate steel and plaster on external surface complete all as specified and shown in drawing and as directed.
OTHER MECHANICAL ITEMS FOR STP WORK PRIMARY TREATMENT SYSTEM S&F of overflow type oil skimmer with flow of 0-50 LPH with belt size 150 mm and motor rating 0.5 HP complete all as specified and directed.
SECONDARY TREATMENT SYSTEM Supply, installation, testing and commissioning (SITC) of submersible, non-clogging, Eaqulized waste Water transfer pump having having 120 m3 / hr at 8 MWC head, continuous duty rating, cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with induction motor 415 V, 3- Phase, 50 Hz of suitable capacity with 2900 RPM, IP 58 protection, class F insulation including installation, foundation as per OEM specification, electrical connection, with suitable rating of copper cables. (1 W + 1 S),
Supply, installation, testing and commissioning (SITC) of twin lobe rotary air blower capable of delivering 1900 m3 / hr of atmospheric air at 0.6 kg/cm2 pressure, driven through "V" belt or directly coupled through flexible coupling to a TEFC motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply complete all as specified and directed and having the following arrangements. (1 W + 1 S)
a. Common Motor &Blower Base Frame with Motor Base Plate and Belt Tightening Arrangement. b. Suction Silencer with Suitable Flanges. c. Suction Air Filter. d. Pressure Gauge. e. Pressure Relief Value (Spring Loaded Type). f. Blower& Motor Pulley with Belt Guard. g. Interconnecting Line with Flanges. h. Filter Hood. j. First Oil Fill. k. V-Belt. l. Butterfly valve (200 mm NB) m. Non Return Valve (200 mm NB) n. Operation & Maintenance Manual.
Supply, installation, testing and commissioning (SITC) of Sodium Hypochlorite dosing system consisting of one HDPE tank of 200 litres capacity, positive displacement diphragm dosing pump having variable flowrate of 0-6 LPH along with motor suitable for operation at 230 V, 1- Ph, 50 Hz. supply and complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall have speed & stroke control complete all as specified and directed.
Supply, installation, testing and commissioning (SITC) of Non clogging type Centrifugal Sludge Recirculation Pumps capable of 150 m3 / hr discharge at 3 MWC head and having solid handling capacity of minimum 32 mm size particles having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. complete all as specified and directed. (1 W + 1S),
Supply and spread a Floating meadia for MBBR reactor in PP construction wagon wheel design having density less than water and the Vergin Media 50 Kgs/M3 & surface area of media, minimum 250 m2 / m3 complete all as specified and directed.
TERTIARY TREATMENT SYSTEM Supply, installation, testing and commissioning (SITC) of Centrifugal filter feed water pump capable of 100 m3 / hr discharge at 18 MWC head having solid handling capacity of minimum 5 mm size particles CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. complete all as specified and directed. (1 W+ 1 S),
Supply, installation, testing and commissioning (SITC) of MSEP vessel for pressure sand filter of ø 1600 mm & 1800 mm HOS (shell & dishend thickness 4.0 mm minimum) suitable for test pressure of 5.0 kg / cm² and working pressure of 3.5 kg / cm², including media (pebbles, sand, silex, fine sand, fine silex), standard fittings viz. pressure gauge, sampling cock, backwash including frontal piping & valves, etc. complete all as specified and directed. (1 W + 1 S)
Supply, installation, testing and commissioning (SITC) of MSEP vessel for activated carbon filter of ø 1800 mm & 2000 mm HOS (shell & dishend thickness 4.0 mm minimum) suitable for test pressure of 5.0 kg/cm² and working pressure of 3.5 kg / cm², including media (activated carbon with supporting media), standard fittings viz. pressure gauge, sampling cock, backwash including frontal piping & valves, etc. complete all as specified and directed. (1 W + 1 S),
SLUDGE DEWATERING SYSTEM Supply, installation, testing and commissioning (SITC) of Non clogging type centrifugal filter press screw pumps capable of 12.90 m3 / hr discharge at 10 MWC head having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. complete all as specified and directed. (1 W + 1 S)
Supply, installation, testing and commissioning (SITC) of filter press machine suitable to handle sludge generated from 2000 KLD STP and as per following specification complete all as specified and directed. (i) Type - Recessed Plate (ii) Material of comstruction - MSEP (iii) Maximum operation pressure - 6.5 Kg / cm2 (iv) Fluid handled - sludge (v) Nature of solids - Biological
S&F of stainless steel 304 pipes conforming to SCH 40 complete all as specified and directed by engineer-in-charge.
NOTE:- [i] Air piping comprising of pipes droppers / laterals with MS (epoxy coated) header complete with all fittings viz. tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc. [ii] Air dispersion system for equilization tank & anoxic / MBBR tank & sludge holding tank with fine & coarse bubblers
Supply, installation, testing and commissioning of wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed.
SEWAGE WATER PIPING M & L for sewage water piping of 150 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 150 mm NB wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 150 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete all as specified and directed.
S&F of Agitators wiith Flange type gear box ,voltage rating 415 V with speed of 100 RPM with munting flange type with motor rating 3 HP & thickness of base plate 5-6 mm and size of base 400 X 200 mm Completed all as specified and directed.
Supply and install disc type 5" coarse diffuser with 12 Nos of perforations per each diffuser having size of 6 mm dia of membrane perforations, air flow rate 20 m3 / hr Completed all as specified and directed.
ANOXIC SLUDGE PIPING M & L for Anoxic sludge piping of SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 200 mm NB wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 200 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete all as specified and directed.
S&F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed.
HYPO DOSING PIPING M & L for Hypo dosing piping of 25 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 25 mm NB Ball Valve of PN 1.6 rated having Forged Brass boy & connector with forged brass ball & spindle complete all as specified and directed
Supply, installation, testing and commissioning of 25 mm NB swing type check valve of PN 1.6 rated having brass body with SS Hing pin complete all as specified and directed.
FILTER PRESS PIPING M & L for filter press piping of 65 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 65 mm NB wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed.
Supply, installation, testing and commissioning of 65 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete all as specified and directed.
Supply, installation, commissioning and testing of ELECTRICAL Panel of suitable size, factory made, CPRI approved type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2.0 mm thick mild steel WIth IP 54 Protection CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. complete all as specified including the following:-
Air Blower 125 A, 10 KA
Treated Water Pump, 40 A, 10 KA
Sludge Re-circulation Pump, 32 A, 10 KA
Filter Feed Pump, 32 A, 10 KA
Equilization Waste Water Pump 32 A, 10 KA
Supply & Install, fix biotic water model type TSM -99 with manual grade on secondary treatment stage and complete civili work with installation in Black color Height of media of 750 mm Moc of media pvc with thickness 1.0 MM with fitting cross sectinal area 75 mm X 60 mm
M&L for cable route indicators made out from CI of suitable shape duly marked MES HT cable fitted with 45 cm long angle iron of size 25x25x4 mm fixed with nuts and bolts, grouted in ground level with PCC of size 15 cm X 15 cm X 30 cm complete all as specified and directed.
Phase - II (M&O FOR STP) Round the clock manning and operation of both sewage treatment plant including all components and items as mentioned in BOQ (2 MLD & 100 KLD STP) here in before in the premises of both STP Viz DG Sets, Panels, Valves and other measuring and control devices and Operator cum blower room & pump house etc including additives, consumables as required for running of sewage treatment plant but excluding diesel and electricity but including maintenance together with repair and replacement of spares of pump sets, starters, MCCBs, MCBs, relays, varnishing of Motor, wiring of panel, Valves, pipes etc complete all as specified and directed. Note:- The defect liability period of STP work is two years. Therefore the rates of repair and replacement of spares etc are not included under this item.
NOTE FOR SERIAL ITEM NO. 84.00 (a) The following minimum staff shall be deployed by the contractor at site:- (i) 1 operator in each shift of 8 hrs (3 shift per day)(Total 3 operation per day). The operator shall be ITI qualified in relevant trade with 2-3 yrs experience. (ii) 1 helper cum sweeper in each shift of 8 hrs ( 2 shift per day) (Total 2 helper per day). (b) Fortnightly testing of treated sewage shall be carried out for the parameters as specified in CA which shall be submitted along with each RAR, cost towards this shall be demed to be included in the units rate quoted. (c) All consumables media and additives including hypo solution shall be provided by the contractor except power, diesel and water which same shall be provided by the department by the free of cost. (d) Plant surroundings shall be kept neat & clean by the contractor. (e) Contractor shall operate and maintain the plant as per the instructions given in the operation manual and shall carry out routine, Annual and breakdown maintenance of the equipment of the system including daily, weekly, monthly, quartely, half yearly and yearly preventive maintenance. (f) Contractor shall maintain the record of attendance for his workmen and staff. (g) Contractor shall dispose off all sludge to the area specified by the engineer -in -charge with in range of 2 KM of STP site. (h) Contractor shall maintain all electrical installations provided under this contract as per IE rules / standered engineering practice. (j) The cost of all consumables (except electricity and diesel) like media and additives, cost of monthly chemical consumption for STP laboratory etc shall be deemed to be included in the unit rate quoted.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .